• 제목/요약/키워드: 환기 시설

검색결과 329건 처리시간 0.032초

무창 분만 ${\cdot}$ 자돈사 환기 형태가 돈사내 환경에 미치는 영향 (Effects of Ventilation Types on Interior Environment of the Enclosed Farrowing-Nursery Pig House)

  • 유용희;송준익;강희설;전병수;김태일;김형호
    • 한국축산시설환경학회지
    • /
    • 제8권2호
    • /
    • pp.79-86
    • /
    • 2002
  • This study was conducted to collect basic data about the effects of ventilation types on the interior environment of the enclosed farrowing-nursery pig house in Anseong, Icheon and Jeungpyong. Surveyed ventilation types in the enclosed farrowing-nursery pig house are classified in to 4 types. In V1 type, air enters through a planar slot inlet placed on the juncture of the entering wall and exit through the chimney fan outlet; in V2 type, air enters through a perforated ceiling inlet and exits chimney fan outlet(V2); in V3 type, air enters through a circular duct inlet and exit chimney fan outlet(V3); in V4 type, enters through a circular duct inlet and exits side wall exhaust fan outlet(V4). Temperature, relative humidity, air velocity and ammonia concentration($NH_3$) were measured in the interior of swine building in the summer. Interior temperature was not remarkably different in all ventilation types in this study. However, temperature of the V4 was somewhat lower than that of the other types. Air velocity of the V4 was higher and $NH_3$ concentration of the V4 was lower than those of other ventilation types. It is suggested that the V4 ventilation type be applicable in the enclosed farrowing-nursery pig house in Korea.

  • PDF

2000m 단일 시추공에서 밀폐 동축 방식 지중 열교환기의 취득온도 성능평가 (Performance Evaluation of Closed Co-axial Ground Heat Exchanger in the case of 2000m-Depth Single Well)

  • 류연수;김재혁;정상화
    • 한국기계가공학회지
    • /
    • 제15권4호
    • /
    • pp.83-92
    • /
    • 2016
  • The Korean government has been making efforts to use renewable energy to reduce the consumption of fossil fuels for the heating system in greenhouses. The number of greenhouses that installed a geothermal heat pump system is 201 EA with the volume of 132.8 ha and 108,467kW from 2010-2014. The geothermal system, called a shallow geothermal system, with the temperature of $10-20^{\circ}C$ has accessories composed of a BHE and heat pump. Moreover, it is necessary to have a wide area to install the BHE and to drill to the depth of 200 m. On the other hand, even though the deep geothermal system needs a high drilling cost to obtain the temperature of $40-150^{\circ}C$, the system has the advantages of the small area required for the BHE and operation without a heat pump. In this study, the temperature of the return water and heat capacity were measured to obtain the geothermal energy efficiently on the condition of the water flow being changed in the BHE. The temperature according to the return water changes through the heat conduction based on the increase of ground temperature up to the underground depth has been calculated to conduct a simulation and is compared with the field experiment test results.

환기를 동반한 철도터널 화재 연기유속 및 온도장 해석 (The Analysis of Fire-Driven Flow and Temperature in The Railway Tunnel with Ventilation)

  • 장용준;이창현;김학범;이우동
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1794-1801
    • /
    • 2008
  • 2006년에 고시가 된 "철도시설 안전세부기준"(건설교통부고시 제2006-395호)에 의하면 1km 이상의 철도터널을 건설할 경우 철도터널에 대한 화재 시뮬레이션을 수행하여 철도터널 내부의 화재에 대한 안전성 분석을 실시하도록 되어있다. 철도터널에서 화재에 대한 안전성 분석을 하기 위해서는 실험적 방법과 수치해석을 이용한 방법이 있는데, 본 연구에서는 수치해석적 방법을 이용하여 터널에서의 화재유동 및 온도장 분포를 해석하였으며, 실험 결과와 비교하여 수치해석의 신뢰성 정도를 분석하였다. Fletcher 등이 수행한 모형 터널 실험을 대상으로 수치해석을 수행하였다. 터널 모형은 길이 182m, 높이 2.4m, 폭 5.4m으로 이루어져 있으며, 수치해석에서도 실험과 동일한 상황을 가정하여 해석을 하였다. 화재가 발생한 부분은 터널의 입구로부터 112m 지점이며, pool fire를 사용하였다. 화재 강도는 약 2.76MW이며, 화원으로써는 Octane을 사용하였다. 수치해석을 위하여 LES 기법을 이용한 FDS (Fire Dynamics Simulator)를 사용하였으며, 본 연구에서는 계산 속도를 증속시키고, 단일 CPU에서는 처리가 곤란한 격자수를 처리하기 위하여 여러 개의 CPU를 사용하는 병렬 처리 기법을 활용하였다. 본 연구에서 사용된 총 격자의 개수는 2.4백만개 이며, 사용된 CPU수는 7개 이다. 수치해석 결과와 실험 결과를 비교 분석하여 수치해석의 신뢰성과 FDS의 철도터널 안전성 분석에의 활용 가능성에 대하여 논하였다.

  • PDF

임대오피스 지하주차장 여유공간을 활용한 임대창고의 경제성 분석 (Economic Analysis for Warehouse Rental Using Underground Parking Lots Extra Storage Room of Rental Office)

  • 이환철;송병두;홍태훈;현창택;문현석
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.877-882
    • /
    • 2008
  • 오피스 지하주차장의 기둥간격은 기준층의 업무환경과 효율적인 주차구획을 고려하여 계획된다. 그러나 비정형의 지하주차장에 정형의 기둥간격에 의한 주차계획을 하다보면 주차장내 많은 부분에 유휴공간이 형성된다. 대부분 주차장의 양 모서리 부분은 주차장 환기시설로서 팬룸이 배치되고, 모서리 일부분은 주차램프가 위치하게 되며 잔여 공간 및 유휴공간에는 창고를 배치할 수 있다. 이때 지하주차장 창고는 필요로 하는 오피스 임차인들에게 외부의 전문창고 임대업체보다 낮은 가격으로 임대하게 된다. 이러한 경우 창고를 만들기 위한 초기 공사비와 유지비용 등이 소요된다. 본 연구에서는 이러한 총 LCC와 초기 투자로 벌어들일 수 있는 임대수익 간의 경제성 분석을 통해 사업 초기 지하주차장 유휴공간에 창고를 설치하는 것에 대한 경제성을 분석하였다. 분석결과, 현재 사용되고 있는 창고임대료를 기준으로 매년 임대수익을 산정하였을 경우, 2년째부터 수익이 보장되어 경제성이 있는 것으로 판단되었다.

  • PDF

자원회수시설용 폐기물 벙커의 환기설비설계 개선에 관한 연구 (Improvement of the Ventilation Equipment in a Waste Bunker For a Municipal Waste Incinerator)

  • 이태구;문정환;허진혁;이재헌
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.51-59
    • /
    • 2007
  • The waste bunker usually consists of waste entrance zone and waste pit. In this paper, the distributions of air flow, $NH_3$ concentration and $H_2S$ concentration in a waste bunker were investigated to prevent an odor generated in a waste pit from dispersing to the waste entrance zone by numerical method. Four cases were considered such that 1) the waste incinerators is operated, 2) the waste incinerators is stopped, 3) the waste incinerator is operated and the direction of a supply diffuser is $45^{\circ}$ upward, 4) the waste incinerator is stopped and the direction of a supply diffuser is $45^{\circ}$ upward. In case of 1), the fresh air from the waste entrance zone is exhausted smoothly to the main exhaust grill of the waste pit. It means that an odor dispersion to the waste entrance zone will not occur. However in case of 2), the induction of fresh air is so small and the supply air with an odor in waste pit can flow to the waste entrance zone. Therefore, an odor will be dispersed to the waste entrance zone. This paper shows the solution that the supply diffuser with the direction of $45^{\circ}$ upward is chosen. As a result in case of 3) and 4), an odor dispersion to the waste entrance zone does not occurred and on odor is exhausted smoothly to the auxiliary exhaust grill.

육계에 있어서 계분의 배설량과 이화학적 특성에 관한 연구 (Research on Quantity and Characteristics of Excreta Produced by Broiler)

  • 이덕수;최희철;곽정훈;강희설;최동윤;한정대;김형호
    • 한국축산시설환경학회지
    • /
    • 제7권1호
    • /
    • pp.33-38
    • /
    • 2001
  • 육계의 분 배설량과 그 특성을 알아보고자 축산기술연구소 시험계사에서 육계 120수를 이용하여 시험을 실시하였으며 그 결과는 다음과 같다. 1. 육계는 6주령시 수당 일일 160.1~165.2g의 사료를 섭취했으며 암텃, 213.0$m\ell$,수컷 252.9$m\ell$의 물을 섭취하였다. 2. 육계 1수당 1일 암수 평균 배설량은 6주령시 생분기눙으로 90.5g이며 육계 1수가 42일령까지 배설하는 누적배설량은 암수 평균 3,800g이었고 이때 계분중의 수분 함량은 79.4%였다. 3. 육계분의 평균 N 함량ㅇㄴ 건물기준으로 N 1.19%, $P_2O_5 1.28%, K_2O$ 2.02%였다. 4. 무창육계사의 여름철 깔짚 중의 수분 함량은 18.3%로 자연환기식 개방계사 계분의 수분함량 29.7%, 간이계사 30.1%보다 낮았다.

  • PDF

제주지역 원도우 베이커리 종사자의 직무환경이 경영성과에 미치는 영향 (The effects of job environments for window bakery employee in Jeju on the management performance)

  • 김철곤
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.35-48
    • /
    • 2019
  • 본 연구는 제주지역 원도우 베이커리 종사자의 직무환경이 경영성과에 미치는 영향을 조사하였다. 그 결과 제주지역 윈도우 베이커리 종사자의 직무환경요인은 인적환경, 작업환경, 시설환경, 복지환경, 편리환경으로 나타났으며, 경영성과 요인으로는 경제적 성과, 고객적 성과, 종사원 성과 요인으로 나타났다. 직무환경요인이 경영성과 중 경제적 성과에는 작업환경(.176), 편리 환경(.227)이 영향력이 있는 것으로 나타났으며, 고객적 성과에는 인적환경(.147), 작업환경(.095)이 영향력이 있는 것으로 나타났으며, 종사원 성과에는 인적환경(.195), 작업환경(.135), 복지환경(.129)이 영향력이 있는 것으로 나타났다. 따라서 제주지역 원도우 베이커리의 직무환경은 경영성과에 유의한 정(+)에 영향을 미칠 것이다라는 가설은 부분채택 되었으며, 경영성과 요인에 모두 영향을 미치는 직무환경 요인으로는 작업환경으로 적당한 습도, 환기 및 작업 동선을 고려한 공간의 배치가 제일 중요한 것으로 나타나, 윈도우 베이커리의 직무환경 중 작업환경개선이 필요한 것으로 나타났다.

강제환기식 육계 사육시설의 계절별, 지점별, 주령별 PM, NH3 농도 조사 및 분석 (Investigation and Analysis of Particulate-matters and Ammonia Concentrations in Mechanically Ventilated Broiler House According to Seasonal Change, Measurement Locations and Age of Broilers)

  • 장동화;권경석;김종복;김중곤;양가영;최성민;장유나
    • 한국농공학회논문집
    • /
    • 제63권1호
    • /
    • pp.75-87
    • /
    • 2021
  • Air quality related to particulate matters and ammonia is being come to the fore as the national concern in Korea. CAPSS (Clean Air Policy Support System) provides emission coefficients of these kinds of particulate and gaseous matters in the fields of livestock; however reliability issues are consistently mentioned. Evaluation of emission rates of PM2.5 and NH3 of the country is very important, but only few studies are available as the background related to observation of the concentration of the particulate matter and ammonia, especially within livestock house in Korea. In this paper, long-term measurement of PM10, PM2.5, and ammonia within the mechanically ventilated broiler house were carried out to introduce backgrounds of generation and emission of the particulate matters and ammonia. Measurement results were analyzed according to seasonal changes, age of broilers(weeks) and measurement locations. Concentration of inhalable and respirable dust were also evaluated in terms of occupational respiratory health according to increase in broiler's activity. From the results of this study, identification of the generation mechanisms of the particulate and gaseous matters, and evaluation of the emission rate of these in the broiler house will be carried out.

강제환기식 산란계 사육시설의 PM, NH3 발생·배출 특성 조사 (Investigation on Generation and Emission of Particulate Matters and Ammonia from Mechanically-ventilated Layer House)

  • 장동화;양가영;권경석;김종복;하태환;장유나
    • 한국농공학회논문집
    • /
    • 제64권1호
    • /
    • pp.99-110
    • /
    • 2022
  • In this study, the generation and emission characteristics of particulate matter and gaseous matter in a mechanically ventilated layer house were evaluated. Each concentration of PM10, PM2.5, inhalable dust, respirable dust, and NH3 was measured and compared with occupational limit considering seasons and respiratory disorder. CAPPS (Clean Air Policy Support System) of the Ministry of Environment proposes the emission factors of PM10, PM2.5, and NH3 for a layer houses however, emission factors are still calculated from foreign factors such as CONINAIR values. As a result, it is urgent to develop national emission factors for domestic layer house. Emission coefficients of the studied mechanically-ventilated layer house in a summer season were calculated as 0.052 kg/head/year for PM10, about 12% lower than that of CAPSS, and 0.0068±0.0038 kg/head/year for PM2.5, showing no significant difference. Emission factor of NH3 was calculated as 0.159±0.031 kg/head/year, about 51% lower than that of CAPSS.

한약재중의 아플라톡신 오염도 조사 (A Survey of the Presence of Aflatoxins in Herb Medicines)

  • 박성규;장정임;하광태;김성단;김욱희;최영희;승현정;김시정;이경아;조한빈;최병현;김민영
    • 한국식품위생안전성학회지
    • /
    • 제24권2호
    • /
    • pp.169-173
    • /
    • 2009
  • 서울약령시장과 시중마트에서 유통되고 있는 생약 145건을 immunoaffinity column 정제 방법을 이용하여 HPLC-FLD로 아플라톡신 오염 실태를 조사한 결과 총 145건 중 10건(6.9%)에서 아플라톡신 오염이 확인되었고, 오염수준은 아플라톡신 $B_1$로서 $0.45{\sim}79.15\;{\mu}g/kg$, 총 아플라톡신으로 $0.05{\sim}97.77\;{\mu}g/kg$의 범위로 빈랑자 19건 중 5건(26%), 백자인 13건 중 4건(31%), 산조인 15건 중 1건(7%)으로 검출 되었고, 백자인 2건, 빈랑자 1건에서 국내 기준치인 $10\;{\mu}g/kg$을 초과 검출 되었다. 아플라톡신이 검출된 생약은 전통적인 방법으로 종이나 비닐팩에 보관하는 방법은 아플라톡신에 오염될 수 있는 가능성을 높임으로 진공 포장과 같이 미생물과의 접촉을 가능한 피할 수 있는 포장 등으로 변경되어야 한다. 또한 아플라톡신 생성균주가 잘 생장할 수 있는 환기가 잘 되지 않고, 고온 다습한 환경이 제공될 가능성이 높은 전통적인 저장 창고와 같은 시설을 항온 항습의 조절이 가능한 현대화 시설로 바꾸는 방안 또한 고려하여야 할 것이다. 곰팡이독소에 대하여 그 대상 품목 및 허용 한계가 다양하게 규제되고 있으나 규제를 하는 것은 아플라톡신이 오염된 식품이나 생약을 섭취 할 위험성을 줄이고자 하는 것이지 근본적인 해결책은 아니다. 서울약령시장 등 생약시장은 매우 영세하고 문제점이 있을 수 있으며 의료 목적으로 환자를 대상으로 사용한다는 점을 감안한다면 더욱 신중하고 신속한 저감화 방안의 마련이 필요할 것이다.