• Title/Summary/Keyword: 환경항목인자

Search Result 186, Processing Time 0.026 seconds

Evaluation and Application of QUAL2E and QUAL2K Models in Anyang Stream (안양천에서 QUAL2E와 QUAL2K 모델의 적용 및 평가)

  • Jung, Sung-Soo;Kim, Kyung-Sub
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.544-551
    • /
    • 2008
  • QUAL2K enhanced QUAL2E and applied in real fields efficiently incorporates denitrification process, sediment-water interaction process, bottom algae and detritus. Also, the CBOD of QUAL2K is divided into two real parts, one is slow CBOD(sCBOD) and another is fast CBOD(fCBOD). The simulation results of QUAL2E and QUAL2K models in Anyang Stream were compared and analyzed in water quality constituents of DO, BOD, Org-N, NH$_3$-N, NO$_3$-N, Org-P, Dis-P and Chl-a respectively. The similar results were shown in Org-N, NH$_3$-N, Org-P and Chl-a both QUAL2K and QUAL2E models. But the different results were revealed in DO, BOD, Dis-P and NO$_3$-N by the influence of new incorporating processes. DO was shown relatively low values in the effect of bottom algae. BOD which is influenced by particulate organic matter was revealed high values. NO$_3$-N was closed to the real values by the two processes of denitrification and sediment-water interaction. To evaluate the running results of QUAL2K and QUAL2E models, a simple statistical analysis was conducted. According to the statistical analysis, QUAL2K represented less relative error and coefficient of variation than QUAL2E in almost all of constituents. It was found that QUAL2K, which simulates the water quality more realistically, can be applied to control and manage the water problems of river or river-run reservoir effectively.

Risk Analysis Method for Deriving Priorities for Detailed Inspection of Small and Medium-sized Fill Dam (중소형 필댐의 정밀점검 우선순위 도출을 위한 간이 위험도 분석 방법)

  • Kim, Jinyoung;Kang, Jaemo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.10
    • /
    • pp.11-16
    • /
    • 2020
  • Korea's agricultural reservoir is one of the country's major infrastructures and plays an important role in people's lives. However, aging reservoirs are a risk for life and property. Currently, large and small dams and reservoirs have been constructed nationwide for more than 40 years of aging. Dams and reservoirs built nationwide are managed by various institutions. Therefore, it is difficult to manage all dams and reservoirs due to cost and time. Managers in the field with less management personnel and lack of expertise should be able to quickly identify risk factors for multiple reservoirs. In this study, risk factors such as seepage, leakage, settlement slide, crack and erosion were selected. To assess the risk of the items, we used the analytical hierarchical process (AHP), one of the Multi-Criteria Decision Making (MCDM) methods. The analysis showed that seepage has the greatest impact on reservoir collapse. It is judged that the priority of detailed diagnosis can be determined by evaluating the risk of dam reservoir collapse in a convenient way in advance using the calculated weight.

Evaluation of Temporal and Spatial Variations of Water Quality at the Streams Flowing into the Suncheon Bay (순천만 유입수계의 시.공간적 수질환경 평가)

  • Park, Sang-Jin;Cheong, Cheong-Jo
    • Journal of Wetlands Research
    • /
    • v.15 no.3
    • /
    • pp.329-337
    • /
    • 2013
  • This study was performed to evaluate the temporal and spatial variations of the water quality at stream flowing into the Suncheon bay in Suncheon city from October 2008 to August 2009 and to estimate the pollutant sources from the streams using multivariate analysis. Water qualities from Seo stream, Dong stream, Ok stream were evaluated as I grade(very good) that compared to the Water Quality Standard. But Haeryong stream and inlet site of Suncheon Bay in BOD were evaluated as a little bad and fair. Water quality at the stream flowing into the Suncheon Bay was could be explained up to 92.8% by three factors which were included in loading of nutrients, organic matter and total coliform group by the allochthonous matters(53.7%), Topographic Factors(25.0%), seasonal variation(14.2%). The concentrations of total nitrogen and phosphorus at sewage treatment plant and organic matters at Haeryong stream were higher than that of others, respectively. From principal component analysis and factor analysis, it could be suggested that it is very important to make an effort to reduce the nutrients and organic matters from sewage treatment plant and Haeryong stream to be in good conservation of the Suncheon bay.

Development of Stream Assessment Technique for Restoration and Management of Urban Stream (도시하천의 복원과 관리를 위한 하천평가기법 개발)

  • Song, Ju Il;Lee, Joon Ho;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3B
    • /
    • pp.283-296
    • /
    • 2008
  • The Urban Stream Assessment Technique (USAT) was suggested to give information about present urban stream condition. Domestic and foreign stream evaluation methods were analyzed and some streams were previously investigated to decide evaluation factors that could evaluate stream condition and have concern with characteristics and flood control of urban stream. The USAT consisted of three steps. High step has three characteristics concerned with functions of stream such as flood risk, stream, and ecology. In middle step, three characteristics were subdivided by ten features to describe changes and degradations of urban stream. Low step consisted of fifty three factors that explain the present condition of ten features. A survey of river experts was conducted to reflect weight among characteristics and features. The weights were calculated by analytic hierarchy process(AHP). The USAT was carried out to check over application of that in Suwon, Anyang, and Joongrang stream. The results of stream evaluation were expressed by factor index, feature index, characteristic index, total index, and evaluation grade. The results of the USAT were useful to realize changed and degraded areas. It is expected that the USAT can be used as base investigation for restoring and managing urban streams.

A Study on the Quantified Evaluation and Application of Stream Environment (하천환경의 정량적 평가 및 활용에 관한 연구)

  • Kim, Jong Oh;Kim, Ok Sun;Kim, Sun Hye
    • Journal of Wetlands Research
    • /
    • v.6 no.3
    • /
    • pp.83-93
    • /
    • 2004
  • The purpose of this study was to develop the environmental management strategy of streams based on the quantified evaluation method of the stream environment. The six streams in Jinju city flowing into the Nam-river were selected for the case study. The stream environment evaluation was performed considering the following three independent field surveys. First, the stream naturalnesses considering 20 evaluation elements were investigated for each unit section of the streams having the length of 500m and the width of 100m, and then were evaluated into 5 grades. Second, water qualities of the streams were evaluated into 5 grades based on the results of eight times water quality survey. Third, the landuse patterns in the stream basins were evaluated into 5 grades according to the residential area ratio. Finally, the stream environments were classified into 5 grades by integrating the above three subfactors - stream naturalness, water quality, and residential landuse. According to the evaluation results of stream environments, the three environmental management strategies of streams were suggested. As the results of the case study, Panmun stream and Ghajwa stream were evaluated to the forth grade that need active environmental restoration, and Nabul stream and Yonga stream were evaluated to the second grade that need partial environmental restoration while Youngchun river and Dogsan stream were evaluated to the first grade showing the desirable stream environmental condition. The above environmental evaluation results for each stream will be an important reference for the further stream restoration or management plan.

  • PDF

Reconsideration for Current Water Quality Monitoring System throughout Daily Observation (매일 관측을 통한 현행 수질 모니터링 시스템 주기에 관한 재고)

  • Bae, Hun-Kyun
    • Journal of Environmental Policy
    • /
    • v.12 no.1
    • /
    • pp.59-74
    • /
    • 2013
  • The weakness of current water quality monitoring system was reviewed to manage Nakdong river's water quality. The current monitoring system has sampling periods lasting for a week to 10 days, but these-SAMpling periods may not accurately measure the real level of water quality. Therefore, daily sampling and analysis of water samples for nine factors was performed from May 1st 2011 to Sep. 30st 2011 to check the water quality changes at three-SAMpling points, Munsanri (the upper side of Kangjung-Koryung weir), Kangchang (the outlet of the Kumho River) and Samunjin (the lower side of Kangjung-Koryung weir). As demonstrated by the results, concentrations of all nine factors dramatically changed on a daily basis, so daily sampling and analysis of water quality samples may be needed instead of weekly sampling and analysis of water quality samples to ensure the proper management of the Nakdong River's water quality. However, daily observations for all water sampling points are not possible because costs and labors are limited, so that new methods which could support the current monitoring system should be developed.

  • PDF

Development of an 1-Dimensional Dynamic Numerical Model for BTX Removal Process Analysis by Gaseous-Biofilm Filtration (기체상-생물막 여과 공법의 BTX 제거 공정 해석을 위한 1차원 동적 수치모델 개발)

  • Kim, Yeong-Kwan;Choi, Sung-Chan;Kim, Seog-Ku;Lee, Yong-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.689-695
    • /
    • 2015
  • A biofilm filtration for the removal of gaseous pollutants has been recognized as a process with a complex interaction between the gas flow characteristics and the process operating variables. This study aims to develop an one dimensional dynamic numerical model which can be utilized as a tool for the analysis of biofilm filtration process operated in plug flow mode. Since, in a plug flow system, minor environmental changes in a gaseous unit process cause a drastic change in reaction and the interaction between the pollutants is an influencing factor, plug flow system was generalized in developing the model. For facilitation of the model development, dispersion was simplified based on the principles of material balance. Several reactions such as competition, escalation, and control between the pollutants were included in the model. The applicability of the developed model was evaluated by taking the calibration and verification steps on the experimental data performed for the removal of BTX at both low and high flow concentration. The model demonstrated a correlation coefficient ($R^2$) greater than 0.79 under all the experimental conditions except for the case of toluene at high flow condition, which suggested that this model could be used for the generalized gaseous biofilm plug flow filtration system. In addition, this model could be a useful tool in analyzing the design parameters and evaluating process efficiency of the experiments with substantial amount of complexity and diversity.

A Study on the Distribution Characteristics of Nitrite Oxidizing Bacteria in Wastewater Nitrification Systems (폐수 질산화 시스템에서 아질산 산화 미생물의 분포 특성 연구)

  • Kim, Sun-Hee;Kim, Dong-Jin;Yoo, Ik-Keun;Cha, Gi-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1024-1030
    • /
    • 2006
  • Genus Nitrospira and Nitrobacter species are the key nitrite-oxidizing bacteria(NOB) in nitrifying wastewater treatment plants. It has been hypothesized that genus Nitrospira are K-strategists(low $K_6$ value) that can exploit low amounts of nitrite more efficiently than Nitrobacter. In contrast, Nitrobacter species are r-strategists(high $V_{max}$) that can grow faster than Nitrospira. It has also been known that the availability of organic compounds and dissolved oxygen as well as nitrite affects the distribution of NOB. In this study, we determined the distribution and competition of NOB in wastewater nitrification systems where nitrite, organic compounds, and dissolved oxygen concentrations were compositively varied. For the purpose, several compounds of the laboratory-scale nitrificaiion bioreactor and full-scale $A_2O$ wastewater treatment plant and their distribution of NOB were analyzed and compared. The analysis showed that Nitrobacter was the dominant NOB in nitrification bioreactor where average nitrite was maintained at 5 mg-N/L with very low organic concentration in aerobic condition, whereas Nitrospira was the dominant NOB in full-scale $A_2O$ plant where nitrite was maintained very low and organic compounds were maintained relatively high in alternating aerobic-anoxic condition. The result indicates that nitrite concentration is more critical factor than organics and dissolved oxygen which determines the dominant NOB in nitrification system and it is confirmed that Nitrospira and Nitrobacter showed the characteristics of r-strategist and K-strategist, respectively.

Study on the Selecting of Suitable Sites for Integrated Riparian Eco-belts Connecting Dam Floodplains and Riparian Zone - Case Study of Daecheong Reservoir in Geum-river Basin - (댐 홍수터와 수변구역을 연계한 통합형 수변생태벨트 적지 선정방안 연구 - 금강 수계 대청호 사례 연구 -)

  • Bahn, Gwonsoo;Cho, Myeonghyeon;Kang, Jeonkyeong;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.23 no.4
    • /
    • pp.327-341
    • /
    • 2021
  • The riparian eco-belt is an efficient technique that can reduce non-point pollution sources in the basin and improve ecological connectivity and health. In Korea, a legal system for the construction and management of riparian eco-belts is in operation. However, it is currently excluded that rivers and floodplains in dam reservoir that are advantageous for buffer functions such as control of non-point pollutants and ecological habitats. Accordingly, this study presented and analyzed a plan to select a site for an integrated riparian ecol-belt that comprehensively evaluates the water quality and ecosystem characteristics of each dam floodplain and riparian zone for the Daecheong Dam basin in Geum River watershed. First, the Daecheong Dam basin was divided into 138 sub-basin with GIS, and the riparian zone adjacent to the dam floodplain was analyzed. Sixteen evaluation factors related to the ecosystem and water quality impact that affect the selection of integrated riparian eco-belt were decided, and weights for the importance of each factor were set through AHP analysis. The priority of site suitability was derived by conducting an integrated evaluation by applying weights to sub-basin by floodplains and riparian zone factors. In order to determine whether the sites derived through GIS site analysis are sutiable for actual implementation, five sites were inspected according to three factors: land use, pollution sources, and ecological connectivity. As a result, it was confirmed that all sites were appropriate to apply integrated riparian ecol-belt. It is judged that the riparian eco-belt site analysis technique proposed through this study can be applied as a useful tool when establishing an integrated riparian zone management policy in the future. However, it might be necessary to experiment various evaluation factors and weights for each item according to the characteristics and issues of each dam. Additional research need to be conducted on elaborated conservation and restoration strategies considering the Green-Blue Network aspect, evaluation of ecosystem services, and interconnection between related laws and policy and its improvements.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.