• 제목/요약/키워드: 환경제거

검색결과 6,060건 처리시간 0.035초

The Air-stripping Process Conjugated with the Ultrasonic Treatment to Remove TOC in Groundwater around the LPG Underground Storage Cavern (탈기법과 초음파 처리법을 연계한 LPG 지하공동저장소 주변 오염지하수 내 TOC 제거)

  • Han, Yikyeong;Jun, Seongchun;Kim, Danu;Jeon, Soyoung;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • 제55권5호
    • /
    • pp.511-519
    • /
    • 2022
  • In order to develop an air-stripping based remediation process to remove the TOC (Total Organic Carbon) in groundwater around the underground LPG storage cavern, the laboratory scale experiments at various conditions (change of air injection volume and temperature, the application of ultrasonic treatment, etc.) for two types of groundwater (initial TOC concentration of 608 mg/L and 153 mg/L, respectively). From results of experiment, as the air injection rate for stripping into groundwater increased from 2 L/min to 11 L/min and as the air-stripping time increased from 1 hour to 24 hour, the TOC removal efficiency of air-stripping increased. However, the TOC concentration of treated groundwater was higher than the discharge tolerance limit (100 mg/L) even after 24 hour stripping at the maximum air injection rate of 11 L/min. The main compounds of the TOC in groundwater were identified as methanol and propane and the long stripping time (more than 24 hour) was needed to separate the methanol from groundwater because of the affinity between water and methanol. At 20℃ and 4 L/min of air injection, the TOC removal efficiency increased to 59.1% after 24 hour air-stripping. When the temperature of groundwater increased to 30℃ and 40℃, the TOC removal efficiency increased up to 80.0% and 82.8%, suggesting that more than 24 hour air-stripping at 40℃ is needed to lower the TOC concentration to below 100 mg/L and the additional TOC removal process as well as the air-stripping is necessary. When the temperature increased to 60℃ and the ultrasonic treatment was conjugated with the air-stripping, the TOC removal efficiency increased to 87.8% within 5 hour stripping and the final TOC concentration (72.4 mg/L) was satisfied with the TOC discharge tolerance limit. The TOC removal efficiency for groundwater having low TOC concentration (153 mg/L) also showed similar removal efficiency of 89.7% (the final TOC concentration: 18.9 mg/L). Results in this study supported that the air-stripping conjugated with the ultrasonic treatment could remove successfully the TOC in groundwater around the underground LPG strorage cavern.

PEG에 고정화된 Pseudomonas aeruginosa를 이용한 NH$_4$-N, NO$_3$-N 동시제거에 관한 연구

  • Park, Gyeong-Hun;Jeong, Gyeong-Hun;Choe, Hyeong-Il;Song, Won-Jong;Gang, Yeong-Ju
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 한국환경과학회 2008년도 추계학술발표회 발표논문집
    • /
    • pp.503-506
    • /
    • 2008
  • 질소제거 능력이 있는 Pseudomonas aeruginosa을 고분자물질인 PEG 에 포괄고정화하였으며 제조된 고정화 미생물을 이용하여 질소제거에 미치는 C/N비, 농도, 충진율, 탄소별 제거율을 검토한 결과 다음과 같은 결론을 얻었다. 1) C/N비 10이상이면 NH$_4$-N 와 NO$_3$-N의 동시 제거가 가능하였으며 2) 탄소 원으로는 glucose를 사용하였을 때 NH$_4$-N 와 NO$_3$-N의 동시 제거가 가능하였으나 methanol은 탄소원으로 사용할 수 없었다. 3) 저농도의 NO$_3$-N(50 mg/L)는 완전히 제거 가능하였으나 NH$_5$-N인 경우에는 초기 NH$_4$-N 100 mg/L에서 60%정도만 제거되었다. 4) 연속처리 결과 NH$_4$-N는 HRT 변동에도 불구하고 유출수 농도 변화가 거의 없었으나, 오히려 C/N비를 증가시키면 NH$_4$-N 제거 효율이 높았고, NO$_3$-N인 경우도 마찬가지로 C/N비를 증가시키면 NO$_3$-N 제거 효율이 높았다.

  • PDF

Performance Comparison of Noise Reduction Algorithms for Enhancing Voice Quality based on Telematics (텔레메틱스 기반의 통화음질향상을 위한 잡음제거 알고리즘의 성능비교)

  • Kim, Hyoung-Gook;Choi, Hong-Jae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • 제11권1호
    • /
    • pp.86-91
    • /
    • 2012
  • To provide high voice quality of real-time voice communication based on telematics exposed to various noise environments, the noise reduction algorithm with low computing load is required to effectively remove the noise. In this paper, we propose a noise reduction algorithm based on Mel-Filter and illustrate the proposed algorithm comparing with conventional noise reduction algorithms. As a experimental result that evaluates the performance of the noise reduction algorithms under the car and babble noise environments, the proposed noise reduction algorithm has the lower computing load with the similar PESQ score compared to the conventional noise reduction algorithms. It proves that the proposed noise reduction algorithm can efficiently remove the noise in mobile telematics.

Multiple Frequency Offsets Cancellation Scheme Based on Alamouti Coded OFDM for Distributed Antenna Systems in Selective Fading Channel (선택적 감쇄환경에서 분산안테나 간 주파수 오차 환경에 강인한 알라무티부호화 직교주파수분할다중방식 기반 간섭 제거기법)

  • Kim, Bong-Seok;Choi, Kwonhue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제38A권12호
    • /
    • pp.1039-1044
    • /
    • 2013
  • We propose a cancellation algorithm based on Alamouti coded OFDM to mitigate ICI due to Frequency Offset (FO) between distributed antennas in the frequency selective fading channel. In the cancellation algorithm, the interference signal is estimated by using the initial detection symbol and then the estimated interference signal is subtracted from the received signal. As the accuracy of initial symbol increases, ICI cancellation becomes more significant. Therefore, the accuracy of the initial detection symbols is very important in the cancellation algorithm. The proposed scheme improves the accuracy of the initial detection symbol by employing an ICI self-cancellation scheme. The proposed cancellation scheme with only one iteration achieves better performance compared to the conventional cancellation schemes with many times iterations based on the conventional Alamouti coded OFDM.

분말과 고정화 $TiO_2$를 이용한 Rhodamin B의 색도 제거 비교

  • 박영식
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 한국환경과학회 2003년도 봄 학술발표회 발표논문집
    • /
    • pp.267-270
    • /
    • 2003
  • 수용성 양이온 안료인 RhB를 대상으로 분말 $TiO_2$와 고정화 $TiO_2$를 이용하여 색도제거실험을 수행한 결과 다음과 같은 결론을 얻었다. 1) 분말 $TiO_2$의 최적 투입량은 0.2 g/L였으며, 대부분 광촉매 반응에 의하여 제거되었다. 고정화 $TiO_2$의 최적 투입량은 210.7 g/L이었고, 광촉매와 흡착에 의해 제거되었다. Langmuir - Hinshelwood 식으로 표현되지 못하였다. 2) 고정화 $TiO_2$를 이용하여 Rhodamine B를 제거할 경우 광촉매 분리 문제는 해결할 수 있으며, 광 투과율을 증가시킬 수 있으나 같은 제거율을 얻기 위해 투입량이 분말에 비해 매우 높은 것이 문제점으로 나타났다.

  • PDF

화산석을 충전한 Biofilter에서 Ethyl acetate와 2-Butanol 제거특성에 관한 연구

  • 임진관;주창식;감상규;이동환;이민규
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 한국환경과학회 2003년도 봄 학술발표회 발표논문집
    • /
    • pp.34-37
    • /
    • 2003
  • 화산석 담체를 충전한 biofilter에서의 ethyl acetate와 2-butanal의 혼합가스의 제거특성에 관한 실험결과는 다음과 같았다. 유입농도 변화 실험에서 EBCT를 30 sec로 유지한 채 혼합가스의 유입농도를 50 ~ 550 ppm 까지 단계적으로 농도를 증가시키면서 살펴본 결과 ethyl acetate는 300 ppm까지 99.9%의 제거효율을 보였으며, 2-butanol은 250 ppm까지 99.9%의 제거효율을 보였다. 유입유량 변화 실험에서 혼합가스의 유입농도를 150 ppm로 일정하게 하고서 EBCT를 60, 30, 15, 10 및 7.5 sec로 단계적으로 감소시킨 결과, EBCT가 15 sec로 유지하여 운전하더라고 99.9%의 높은 제거효율을 보였다. 또한 ethyl acetate 및 2-butanol의 최대제거용량은 각각 180 b/㎥/hr로 산정되었다. 이러한 결과들은 화산석이 biofilter의 충전 담체로 우수함을 보여주었다.

  • PDF

매립장 침출수에 의한 오염지하수 정화 방법 연구

  • 송나인;도원홍;이민희
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.413-416
    • /
    • 2004
  • 매립장 침출수로 인해 오염된 매립장 주변 지하수 정화를 위한 실내실험을 실시하였다. 오염물로는 대표적 염화용제인 TCE와 PCE, 그리고 중금속인 As, Cd, Cr, Pb에 대하여 Air-sparging, 오존 산화법, 화학적 처리방법에 의한 정화효율 실험을 실시하였다. Air-sparging은 TCE, PCE에서 높은 제거효율을 가졌으며, 오존 산화법은 Cr, Pb에서 제거 효율이 좋았다. 반응제를 첨가한 공침방법의 경우, 모든 중금속에 대하여 소석회 첨가시 매우 높은 제거효율을 보였으며, As는 황산제일철에서, Cd, Cr, Pb는 탄산칼슘과 제올라이트 첨가시 높은 제거효율을 나타내었다. 실험결과로부터, 유기오염물과 중금속이 혼합되어 나타나는 매립장 주변 오염 지하수의 경우 휘발성 유기오염물의 제거를 위해서는 폭기방법이, 중금속의 경우에는 공침방법에 의해 수산화물, 탄산염으로 만들어 고형물로 처리하는 방법이 제거효과가 좋은 것으로 나타났다.

  • PDF

수피에 의한 폐수중의 카드뮴 이온의 제거

  • 민용원;이해익;정연호
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 1996년도 경북지부 결성 및 추계학술발표회 논문집
    • /
    • pp.97-101
    • /
    • 1996
  • 산림부산물인 수피에 의한 카드뮴 이온의 선택적 흡착 현상을 이용하여 인공폐수로부터 카드뮴이온의 제거를 시도하였다. 카드뮴 이온 선택성이 우수한 소나무와 상수리 나무의 수피를 이용한 효율적인 연속식 대량 수처리 시스템의 개발을 위한 기초 실험으로 카드뮴 이온흡착 등온선을 조사하였고, batch stirred reactor, airlift reactor, packed bed column 등 여러 접촉시스템에서의 카드뮴 이온의 제거 효율을 검토하였다. 카드뮴 흡착등온선은 두 수피 모두 Langmuir 형식으로 나타났으며 소나무 수피의 최대흡착용량은 약 7 mg/g, 상수리나무 수피의 경우에는 약 8 mg/g 정도로 나타났다. Batch stirred reactor를 이용한 시스템에서 초기농도 13 ppm의 카드뮴용액 100 $m\ell$ 을 수피 10 g 과 접촉시킨 결과 30분 이내에 95% 이상 제거되는 효율성을 보여주었다. Airlift reactor를 이용한 시스템에서는 수피 30 g 을 포기농도 10 ppm 카드뮴 용액 1 liter와 접촉시킨 결과 15분 이내에 93 % 이상 제거되었으며 4 cycle 반복 운전에서도 거의 같은 성능을 유지하였고 그 이상의 cycle에서는 점점 성능이 떨어짐을 보여주었다. Packed bed column을 이용한 시스템에서는 20 g의 수피를 충전시켰을 경우 초기농도 20 ppm에서 effluent 2.5 liter 까지는 95% 정도의 제거효율을 보여주었다.

  • PDF

SIMULTANEOUS REMOVAL OF NITROGEN AND PHOSPHORUS USING THE SEQUENCING BATCH REACTORS PROCESS (SBR 활성슬러지 공정을 이용한 질소 및 인의 동시제거 연구)

  • 양형재;신응배;정윤철
    • Journal of environmental and Sanitary engineering
    • /
    • 제12권3호
    • /
    • pp.1-7
    • /
    • 1997
  • 이 연구에서는 SBR 공법을 이용하여 질소, 인 동시제거기장에 대해 관찰하고 BOD-SS loading변화에 따른 오염물질 제거효율에 대해 검토하였다. BOD, TN 및 TP 제거율은 $20^{\circ}C$에서 95%, 74% and 81%로 나타났으며, Phosphorus luxury uptake는 호기성이 시작된후 1,2시간후에 각각 67% 및 84%를 흡수 하는 것으로 관찰 되었으며, 호기성 말기의 농도는 $0.9mg/{\ell}$ 이하를 유지하였다. 80% 및 85% 이상의 안정된 질소 제거효율을 유지하기 위해서는 BOD-SS loading 값을 0.15 및 0.08 kg-BOD/kg-SS.day 이하로 유지하여야 하는 것으로 나타났다. 또한 1회 방류수량의 변화에 따른 관찰에서, 반응조 유효용량의 30%, 40% 및 50%를 유출할 경우 TN은 각각 78%, 72% 및 58%를 TP는 각각 81%, 77% 및 66%의 제거효율을 보였다.

  • PDF

A new interference cancellation applying widowing technique in PCS environment (PCS 환경에서 윈도우 기법을 적용한 새로운 직렬 간섭 제거 기술)

  • 도상현;김의묵;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제22권11호
    • /
    • pp.2388-2400
    • /
    • 1997
  • In this paper, we analyzed the serial interference cancellation scheme and proposed the new serial interference cancellation scheme suppressing multiple access interference. Compensating for the near-far effect and the multiple access interference is critical for the stable performance of DS/CDMA system, and the serial multiple access interference cancellation has been proposed as one of the compensation methods. But this serial interference cancellation scheme has a linear variation in the number of cancellation operation each users. Becaure of this variation, it is difficult to show a stable performance. Hence, we suggested a new serial interference applying window technique to overcome this fault and made a performance estiamation.

  • PDF