• Title/Summary/Keyword: 환경시험장비

Search Result 424, Processing Time 0.03 seconds

Development of Tacho Generator for Application of Anti-aircraft Weapon System (대공무기체계 적용을 위한 타코제너레이터 개발)

  • Byun, Kisik;Park, Jun Young;Cho, Sung-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.174-180
    • /
    • 2020
  • This paper presents the development of a tacho generator that is applicable to a DC motor for anti-aircraft weapon systems. In general, devices such as tacho generators and resolvers are used as feedback devices for controlling DC motors. A tacho generator with a wide operating temperature range was developed, which has robust characteristics against shock loads and vibrations according to the operational characteristics of anti-aircraft weapon systems. The target specifications were set based on the requirements of the tacho generator currently in operation. A rotor coupled to the shaft of the motor and a stator coupled to the housing of the motor were then designed and manufactured. The inductance was 31.0 mH, the terminal resistance was 147.7 ohms, and the rotational measurement factor was satisfactory under both normal operation and operating conditions after the maximum speed for the standard of 9.500 ± 0.475 V/krpm. In addition, the environmental suitability of the applied equipment was confirmed through the rate of change in unit temperature, and it was found that the temperature characteristics were all within 0.03 %/℃.

Cleaning Effects of Environmental-Friendly Washing Detergent on Milking Installation in Dairy Farms (젖소농가의 착유시설에 따른 친환경세제의 세척에 미치는 영향)

  • Kim, Chang-Hyun;Park, Joong-Kook
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.346-353
    • /
    • 2010
  • This study was conducted to determine cleaning effects of environmental-friendly washing detergent on milking installation in dairy farms. Milking machine, cooling machine and milking liner were washed by alkaline detergent and acid detergent for first three weeks and alkaline detergent and environmental~friendly detergent for next three weeks and the results get through microorganism and physico-chemistry analysis at the five district dairy farms different from environment. E-coli, coliform, fecal coliform, staphylococcus aureus, fecal streptococcus, prsudomonas aeruginosa and yersinia were not found in all of the dairy farms, and total colony counts were no difference compared with chemical detergent. The water for washing exceeded the determining acceptable level of nitrate nitrogen in the Anseong, Onyang and Cheonan and the remaining substance of washed water was also high levels. The cause of the result was that the level of nitrate nitrogen of water is basically high. Therefore, this study indicated that washing effect is no differences between environmental-friendly detergent and chemical detergent by washing for milking machine and cooling machine. Above all, producing high quality milk is to manage the water quality as well as using detergent.

Detection of Buried Objects and Imaging of Subsurface Resistivity Structure using Loop-Loop EM Methods (소형루프 전자탐사법을 이용한 매설물 탐지 및 지하 전기비저항 영상화)

  • Seol Soon Jee;Song Yoonho;Cho Seong-Jun;Son Jeong-Sul;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.309-315
    • /
    • 2002
  • Conventional electromagnetic (EM) method using small loops as a source and receiver has been used in detection of conductive buried objects like a metal detector or in qualitative estimation of the subsurface conductivity variation. Recently, however, since detection of buried objects and imaging of the subsurface conductivity distribution in a relatively conductive area are in a high demand for environmental and engineering purposes, the quantitative interpretation technique of EM data is actively studied. In this regard, we introduce a brief principle of EM survey and show an example of the detection of buried conductive material and imaging of the subsurface conductivity distribution based on data measured at a test survey area. Through this study, we show that multi-frequency EM surveys using small loops may be a good solution to give quick and detail information of subsurface in a conductive survey area.

Prioritizing for Failure Modes of Dynamic Positioning System Using Fuzzy-FMEA (Fuzzy-FMEA를 이용한 동적위치제어 시스템의 고장유형 우선순위 도출)

  • Baek, Gyeongdong;Kim, Sungshin;Cheon, Seongpyo;Suh, Heungwon;Lee, Daehyung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.174-179
    • /
    • 2015
  • Failure Mode and Effects Analysis (FMEA) has been used by Dynamic Positioning (DP) system for risk and reliability analysis. However, there are limitations associated with its implementation in offshore project. 1) since the failure data measured from the SCADA system is missing or unreliable, assessments of Severity, Occurrence, Detection are based on expert's knowledge; 2) it is not easy for experts to precisely evaluate the three risk factors. The risk factors are often expressed in a linguistic way. 3) the relative importance among three risk factors are rarely even considered. To solve these problems and improve the effectiveness of the traditional FMEA, we suggest a Fuzzy-FMEA method for risk and failure mode analysis in Dynamic Positioning System of offshore. The information gathered from DP FMEA report and DP FMEA Proving Trials is expressed using fuzzy linguistic terms. The proposed method is applied to an offshore Dynamic Positioning system, and the results are compared with traditional FMEA.

Design and Implementation of Adaptive Beam-forming System for Wi-Fi Systems (무선랜 시스템을 위한 적응형 빔포밍 시스템의 설계 및 구현)

  • Oh, Joohyeon;Gwag, Gyounghun;Oh, Youngseok;Cho, Sungmin;Oh, Hyukjun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2109-2116
    • /
    • 2014
  • This paper presents the implementation and design of the advanced WI-FI systems with beam-forming antenna that radiate their power to the direction of user equipment to improve the overall throughput, contrast to the general WI-FI systems equipped with omni-antenna. The system consists of patch array antenna, DSP, FPGA, and Qualcomm's commercial chip. The beam-forming system on the FPGA utilizes the packet information from Qualcomm's commercial chip to control the phase shifters and attenuators of the patch array antenna. The PCI express interface has been used to maximize the communication speed between DSP and FPGA. The directions of arrival of users are managed using the database, and each user is distinguished by the MAC address given from the packet information. When the system wants to transmit a packet to one user, it forms beams to the direction of arrival of the corresponding user stored in the database to maximize the throughput. Directions of arrival of users are estimated using the received preamble in the packet to make its SINR as high as possible. The proposed beam-forming system was implemented using an FPGA and Qualcommm's commercial chip together. The implemented system showed considerable throughput improvement over the existing general AP system with omni-directional antenna in the multi-user communication environment.

A study to improve the existing rumble-strip (기존 노면요철 포장 개선 연구)

  • Ryu, Sung-Woo;Lim, Kwan;Park, Kwon-Je;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.177-186
    • /
    • 2009
  • Rumble strip was introduced in highway pavement for driver's safety in Korea on 2000. With proving its effectiveness, total length of highway with rumble strip has increased. This research team suggested a modified form of the existing rumble strip, which was placed on new concrete pavement during construction. The modified construction equipment was applied on test section at PyungTeak-Eumsung highway with some performance experiments. Through the equation of stopping sight distance proposed AASHTO, the modified form is safer than the existing one due to 0.65m of extra width. The indoor noise test showed that the modified form $3.5{\sim}9dB(A)$ noisier than the main pavement, which wasn't applied by rumble method. Therefore, it was one of alternatives to prevent sleeping. The modified form made the frequency effected on man's eye. There were no differences of the noise and vibration between modified form and existing one. However, that driver who participated on operating test on that section felt that the former was safer than the latter. It can be concluded that modified form can be applied to the new concrete pavement, that will decrease traffic accident.

  • PDF

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Design and Implementation of User-Level FileSystem in the Combat Management System

  • Kang, Seok-Hyun;Kim, Keun-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.12
    • /
    • pp.9-16
    • /
    • 2022
  • In this paper, we propose a plan to design and utilize the RDBS(Record Block Data file management System) so that data can be recovered when data files in the Combat Management System are mismatched. The CMS(Combat Management System) manages the same files in multiple IPN(Infomation Processing Node) repositories to support multiplexing. However, mismatches in data files can occur due to equipment maintenance or user immaturity. The existing CMS does not manage the history of changes in data files, and when a mismatch occurs, data file were synchronized based on the latest date. But, It is difficult to say that files with the latest date have the highest reliability, and once the file synchronization has progressed, it cannot be recovered with pre-synchronization data. To solve this problem, data was stored and synchronized in units of record blocks using RDBS proposed in this paper, and the Rsync algorithm was used to reduce the overhead of file synchronization due to units of record blocks. SW applied with RDBS was tested for performance in a simulated environment, and it was confirmed that it could be applied to CMS through normal operation confirmation.

Review on the application of single-shell tunnel in Korea (싱글쉘 터널의 국내 적용에 대한 고찰)

  • Sangpil Lee;Heesang Ha;Donghyun Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.3
    • /
    • pp.223-242
    • /
    • 2024
  • Single-shell tunnels, introduced to South Korea in the early 2000s, have not been adopted for the main tunnels of roads or railways over the past two decades despite several attempts starting with the Gwangju City Bypass. This reluctance likely arises from concerns about the long-term performance of supporting materials and the absence of relevant criteria and specifications. However, recent progress, including the incorporation of high-strength shotcrete standards and corrosion-resistant rock bolt specifications, alongside equipment and technique enhancements, necessitates a reassessment of single-shell tunnels. While the single-shell tunnel method offers advantages in environmental impact, construction cost and period compared to the conventional NATM, it is crucial to address the challenges, such as limited design and construction experience, incomplete detailed standards, and insufficient construction specifications, through further research and pilot projects. This paper reviewed the basic principles of single-shell tunnel, current application and research status, technical development trends, criteria and specifications, and remaining challenges. It aims to reignite discussions on the feasibility of applying single-shell tunnels in South Korea.

A Suvey on Satisfaction Measurement of Automatic Milking System in Domestic Dairy Farm (자동착유시스템 설치농가의 설치 후 만족도에 관한 실태조사)

  • Ki, Kwang-Seok;Kim, Jong-Hyeong;Jeong, Young-Hun;Kim, Yun-Ho;Park, Sung-Jai;Kim, Sang-Bum;Lee, Wang-Shik;Lee, Hyun-June;Cho, Won-Mo;Baek, Kwang-Soo;Kim, Hyeon-Shup;Kwon, Eung-Gi;Kim, Wan-Young;Jeo, Joon-Mo
    • Journal of Animal Environmental Science
    • /
    • v.17 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • The present survey was conducted to provide basic information on automatic milking system (AMS) in relation to purchase motive, milk yield and quality, customer satisfaction, difficulties of operation and customer suggestions, etc. Purchase motives of AMS were insufficient labor (44%), planning of dairy experience farm (25%), better performance of high yield cows (19%) and others (6%), respectively. Average cow performance after using AMS was 30.9l/d for milk yield, 3.9% for milk fat, 9,100/ml for bacterial counts. Sixty-eight percentage of respondents were very positive in response to AMS use for their successors but 18% were negative. The AMS operators were owner (44%), successor (44%), wife (6%) and company worker (6%), respectively. The most difficulty (31%) in using AMS was operating the system and complicated program manual. The rate of response to system error and breakdown was 25%. The reasons for culling cow after using AMS were mastitis (28%), reproduction failure (19%), incorrect teat placement (12%), metabolic disease (7%) and others (14%), respectively. Fifty-six percentages of the respondents made AMS maintenance contract and 44% did not. Average annual cost of the maintenance contract was 6,580,000 won. Average score for AMS satisfaction measurement (1 to 5 range) was 3.2 with decrease of labor cost 3.7, company A/S 3.6, increase of milk yield 3.2 and decrease of somatic cell count 2.8, respectively. Suggestions for the higher efficiency in using AMS were selecting cows with correct udder shape and teat placement, proper environment, capital and land, and attitude for continuous observation. Systematic consulting was highly required for AMS companies followed by low cost for AMS setup and systematization of A/S.