• Title/Summary/Keyword: 화학적 일체화

Search Result 14, Processing Time 0.026 seconds

A Study on the Chemical Integration between Coating Sheets of Complex Waterproofing Method Using Modified Amine-Treated Nonwoven Fabric (변성아민 처리된 부직포를 이용한 복합방수공법의 도막·시트 간 화학적 일체화에 관한 연구)

  • Kim, Sun-Do;Kim, Jin-Sung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.118-119
    • /
    • 2017
  • The combined waterproofing method is an excellent method to overcome the disadvantages of the single waterproofing method by composing two or more materials to complement each other, but it is a method that can cause defects such as separation and peeling between materials due to the heterogeneity of the applied two materials. In order to improve this, in this study, we aimed to develop a technology for inducing chemical unification between materials through a urea reaction with a coating material applied on the lower side by laminating a nonwoven fabric treated with a modified amine on the back surface of the sheet material, The adhesion performance test was carried out with the presence or absence of denatured amine treated nonwovens as variables. As a result of the test, it was confirmed that the adhesion performance of the specimen to which the modified amin - treated nonwoven fabric was applied was improved by about 60% or more as compared with the specimens not having the denatured amine treated specimen.

  • PDF

Electrochemical Characteristics of Assembled-Graphite/DSA Electrode for Redox Flow Battery (Redox Flow Battery용 일체화된 흑연/DSA 전극의 전기화학적 특성)

  • Kim, Hyung-Sun
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.2
    • /
    • pp.123-127
    • /
    • 2010
  • An assembled-graphite/DSA(Dimensionally Stable Anode) was prepared using graphite powder to increase durability and energy efficiency of redox flow battery and investigated its electrochemical properties in vanadium-based electrolyte. The cyclic voltammetry (CV) was carried out in the voltage range of -0.7V and 1.6V vs. SCE at 5 mV/sec scan rate to analyze vanadium redox reaction. From the CV results, the assembled-graphite/DSA electrode showed a fast couple reaction and good reversibility in 2M $VOSO_4$ + 2.5 M $H_2SO_4$ electrolyte. Therefore, it has been expected that this electrode increases power density as well as energy density of redox flow battery.

Understanding of Polymer Electrolyte Membrane for a Unitized Regenerative Fuel Cell (URFC) (일체형 재생 연료전지(URFC)용 고분자 전해질 막의 이해)

  • Jung, Ho-Young
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.125-132
    • /
    • 2011
  • A unitized regenerative fuel cell (URFC) as a next-generation fuel cell technology was considered in the study. URFC is a mandatory technology for the completion of the hybrid system with the fuel cell and the renewable energy sources, and it can be expected as a new technology for the realization of hydrogen economy society in the $21^{st}$ century. Specifically, the recent research data and results concerning the polymer electrolyte membrane for the URFC technology were summarized in the study. The prime requirements of polymer electrolyte membrane for the URFC applications are high proton conductivity, dimensional stability, mechanical strength, and interfacial stability with the electrode binder. Based on the performance of the polymer electrolyte membrane, the URFC technology combining the systems for the production, storage, utilization of hydrogen can be a new research area in the development of an advanced technology concerning with renewable energy such as fuel cell, solar cell, and wind power.

Characteristics of Strong Alkaline Electrolyzed Water Produced in All-in-one Electrolytic Cell (일체형 전해조에서 생산된 강알카리성 전해수의 특성)

  • Lee, Ho Il;Rhee, Young Woo;Kang, Kyung Seok
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.446-450
    • /
    • 2012
  • Strong alkaline electrolyzed water which is produced in cathode by electrolyzing the solution where electrolytes (NaCl, $K_2CO_3$ etc.) are added in diaphragm electrolytic cell, is eco-friendly and has cleaning effects. So, it is viewed as a substitution of chemical cleaner. In addition, strong alkaline electrolyzed water is being used by some Japanese automobile and precision parts manufacturing industries. When strong alkaline electrolyzed water is produced by using diaphragm electrolytic cell, it is necessarily produced at the anode side. Since strong acidic electrolyzed water produced is discarded when its utilization cannot be found, production efficiency of electrolyzed water is consequently decreased. Also, there is a weakness electrolytic efficiency is decreasing due to the pollution of diaphragm. In order to overcome this, non-diaphragm all-in-one electrolytic cell integrated with electrode reaction chamber and dilution chamber was applied. Strong alkaline electrolyzed water was produced for different composition of electrolytes, and their properties and characteristics were identified. In comparing the properties between strong alkaline electrolyzed water produced in diaphragm electrolytic cell and that produced in all-in-one electrolytic cell, the differences in ORP and chlorine concentration were found. In emulsification test to confirm surface-active capability, similar results were obtained and strong alkaline electrolyzed water produced in non-diaphragm all-in-one electrolytic cell was identified to be useable as a cleaner like strong alkaline electrolyzed water produced in diaphragm electrolytic cell. Strong alkaline electrolyzed water produced in non-diaphragm all-in-one electrolytic cell is thought to have sterilizing power because it has active chlorine which is different from strong alkaline electrolyzed water produced in diaphragm electrolytic cell.

A Study on Repair Method of Concrete Structures using the Solution of Removing Chloride (염분제거용 약액을 이용한 콘크리트 구조물의 보수공법에 관한 연구)

  • Kim, Woonhak;Hwang, Sungwoon;Kang, Seokwon
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.562-569
    • /
    • 2017
  • Reinforced concrete is used for bridges and large structures that are constructed with social overhead capital because they are economically and semi-permanently integrated with reinforcing bar and concrete. However, when the chloride ion in the concrete destroys the passive film of the reinforcing bar by the marine exposure environment and the snow remover used in the winter season, and the reinforcing bar is corroded by various chemical and physical actions, the durability is deteriorated in a short period, and the life span is shortened. In this study, a repair method to recover the durability of the initial structure by effectively removing chloride ion from the damage caused by salting of the above mentioned reinforced concrete was conducted.

Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate (매입형(슬림플로어) 합성보의 휨성능 평가 -춤이 깊은 데크플레이트와 비대칭 H형강 철골보-)

  • Heo, Byung Wook;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.235-245
    • /
    • 2004
  • The advantages of composite construction are now well understood in terms of structural economy, good performance in service, and ease of construction. However, these conventional composite construction systems have some problems in application to steel framed buildings due to their large depth. So, in this study we executed an experimental test with the "Slim Floor"system which could reduce the overall depth of composite beam. Slim Floor system is a method of steel frame multi-story building construction in which the structural depth of each floor is minimized by incorporating the steel floor beams within the depth of the concrete floor slab. Presented herein is an experimental study that focuses on the flexural behaviour of the partially connected slim floor system with asymmetric steel beams encased in composite concrete slabs. Eight full-scale specimens were constructed and tested in this study with different steel beam height, slab width, with or without shear connection and concrete topping thickness. Observations from experiments indicated that the degree of shear connection without additional shear connection was $0.53{\sim}0.95$ times that of the full shear connection due to inherent mechnical and chemical bond stress.

Flexural Capacity of Encased Composite Beam with Hollow Core PC Slabs (매입형 합성보의 휨 성능 평가 -속 빈 프리캐스트 콘크리트 슬래브와 비대칭 H형강 철골보-)

  • Heo, Byung Wook;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.587-598
    • /
    • 2004
  • In this study, an experiment was conducted on the Slim Floor system, using a hollow core PC slab, which could reduce the over-all depth of a composite beam. The Slim Floor system is a method used in steel frame multi-story building construction, in which the structural depth of each floor is minimized after incorporating the steel floor beams within the depth of the concrete floor slab. This experimental study focused on the flexural behavior of the partially connected Slim Floor system with asymmetric steel beams encased in hollow core PC slabs. Ten full-scale specimens were constructed and tested in this study, with different steel beam heights, hollow core PC slabs, slab widths, and PC slab bearings. Observations made in line with the experiments indicated that the degree of shear connection without additional shear connection was 0.48-0.98 times more than that of the full shear connection, due to inherent mechanical and chemical bond stress.

Removal of Nitrogen Using by SOD Process in the Industrial Wastewater Containing Fluoride and Nitrogen from the Zirconium Aolly Tubing Production Factory of the Nuclear Industry (원자력산업 지르코늄합금 튜브 생산공장에서 배출되는 불소.질소 함유 폐수의 황산화탈질을 이용한 질소처리)

  • Cho, Nam-Chan;Moon, Jong-Han;Ku, Sang-Hyun;Noh, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.855-859
    • /
    • 2011
  • The main pollutants from zirconium alloy tubing manufacturing process in nuclear industry are nitrate ($NO_3-N$) and fluoride (F-)Nitric acid, and hydrofluoric acid is used for acid pickling. The process for the removal of nitrate and fluoride is composed of 1st chemical coagulation, SOD (Sulfur Oxidation Denitrification) process using sulfur-oxidizing denitrification, and 2nd chemical coagulation. The characteristic of the wastewater treatment is an application of SOD process. The SOD Process is highly received attention because it is significantly different from existing processes for sulfur denitrification. A JSC (JeonTech-Sulfur- Calcium) Pellet is unification of sulfur and alkalinity material. According to result of SOD process in wastewater treatment plant, the removal efficiency of T-N was over 91% and the average concentration of T-N from influent was 147.55 mg T-N/L and that from effluent was 12.72 mg T-N/L. Therefore, SOD process is a useful to remove nitrogen from inorganic industrial wastewater and a new development of microbial activator was shown to be stable for activation of autotrophic bacteria.

An Electro-Fenton System Using Magnetite Coated One-body Catalyst as an Electrode (일체형 산화철 촉매를 전극으로 하는 전기펜톤산화법)

  • Choe, Yun Jeong;Ju, Jeh Beck;Kim, Sang Hoon
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.117-121
    • /
    • 2018
  • A stainless steel mesh was applied to the cathode of an electro-Fenton system. Methylene blue (MB) solution was chosen as the model waste water with non-biodegradable pollutants. For the model waste water, the degradation efficiency was compared among various SUS mesh cathodes with different surface treatments and magnetite coatings on them. With increasing amount of the magnetite coating on SUS mesh, the degradation efficiency also increased. The improved electro-catalytic characteristic was explained by the increased amount of in situ generated hydrogen peroxide near the cathode surface. Cyclic voltammetry data also showed improved electro-catalytic performance for SUS mesh with more magnetite coatings on them.

Integrated Science Teachers' Implementation and Changes to Apply the Curriculum-Instruction-Assessment (통합과학 교사의 교육과정-수업-평가 실행 및 변화 조사)

  • Park, HyunJu;Kim, NaHyeong
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.429-437
    • /
    • 2020
  • This study investigated a total of 529 integrated science teachers' implementation and changes to apply the curriculum-instruction-assessment. Data was collected through online survey on scientific competencies and skills, teaching-learning and assessment methods, changes of teacher's preparation, topics/materials, teaching-learning, and assessment to apply the curriculum-instruction-assessment as teaching integrated science. The results of the study were as follows: first, in the integrated science class, teachers implemented more on scientific communication and scientific inquiry among scientific core competencies, and analysis and interpretation of data collection and communication among scientific skills. Teachers often taught in lectures and used multiple choice items and short essay for evaluation. Teacher groups with less than 10 years of teaching experience appeared to be less active in teaching scientific core competencies and skills than those with more than 10 years. Second, Teachers have increased more time and efforts to search and to organize various materials in addition to textbooks, and try to integrated concepts in various fields to prepare learning topics and textbooks. Third, even though teachers made little change in implementing the process-oriented assessment, they used instructional strategies to increase student engagement in the integrated science class, restructured the instruction to provide immediate feedback after conducting the assessment. It is necessary to build a system that ensures fairness and credibility of evaluation while respecting the autonomy and professionalism of teachers.