Construction of Event Tree & Fault Tree for Train Fire Risk Assessment (철도화재사고 위험도평가를 위한 Event Tree 및 Fault Tree 구성)

  • Kwak, Sang-Log;Wang, Jong-Bae;Lee, Bong-Seob;Park, Chan-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.6
    • /
    • pp.530-535
    • /
    • 2008
  • After train fire accident in Daegue, many research on train fire safety improvement have been carrying out. Since many alternative fire safety measures can be applied in our railway system, the effect of the each safety measure must be quantified prior to the safety investment. In order to estimate the effects of each safety measure quantitatively, fault trees and event trees are constructed in this study. Results can be applied for cost-benefit analysis or sensitivity analysis for safety measures in risk assessment process.

화재 PSA 방법론에 대한 고찰

  • 이윤환;양준언
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.69-74
    • /
    • 2002
  • 원자력발전소에서 발생하는 화재사건은 원자로 정지를 유발함과 통시에 안전정지 또는 사고완화 기능을 수행하는 다수의 기기를 동시에 손상시킬 수 있어 원자력발전소의 안전성에 적지 않은 영향을 줄 수 있다. 미국에서는 1975년 Browns Ferry 원전 1호기 케이블 포설실(cable spreading room)의 케이블 관봉투 밀봉재에 대한 건전성을 검사하는 과정 중에 화재가 발생하여 원자로 건물로 화재가 확산되는 심각한 사고가 발생하였다.(중략)

  • PDF

A Study on the Improvement Plans of Police Fire Investigation (경찰화재조사의 개선방안에 관한 연구)

  • SeoMoon, Su-Cheol
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.103-121
    • /
    • 2006
  • We are living in more comfortable circumstances with the social developments and the improvement of the standard of living, but, on the other hand, we are exposed to an increase of the occurrences of tires on account of large-sized, higher stories, deeper underground building and the use of various energy resources. The materials of the floor in a residence modern society have been going through various alterations in accordance with the uses of a residence and are now used as final goods in interioring the bottom of apartments, houses and shops. There are so many kinds of materials you usually come in contact with, but in the first place, we need to make an experiment on the spread of the fire with the hypocaust used as the floors of apartments, etc. and the floor covers you usually can get easily. We, scientific investigators, can get in contact with the accidents caused by incendiarism or an accidental fire closely connected with petroleum stuffs on the floor materials that give rise to lots of problems. on this account, I'd like to propose that we conduct an experiment on fire shapes by each petroleum stuff and that discriminate an accidental tire from incendiarism. In an investigation, it seems that finding a live coal could be an essential part of clearing up the cause of a tire but it could not be the cause of a fire itself. And besides, all sorts of tire cases or fire accidents have some kind of legislation and standard to minimize and at an early stage cope with the damage by tires. That is to say, we are supposed to install each kind of electric apparatus, automatic alarm equipment, automatic fire extinguisher in order to protect ourselves from the danger of fires and check them at any time and also escape urgently in case of fire-outbreaking or build a tire-proof construction to prevent flames from proliferating to the neighboring areas. Namely, you should take several factors into consideration to investigate a cause of a case or an accident related to fire. That means it's not in reason for one investigator or one investigative team to make clear of the starting part and the cause of a tire. accordingly, in this thesis, explanations would be given set limits to the judgement and verification on the cause of a fire and the concrete tire-spreading part through investigation on the very spot that a fire broke out. The fire-discernment would also be focused on the early stage fire-spreading part fire-outbreaking resources, and I think the realities of police tire investigations and the problems are still a matter of debate. The cause of a fire must be examined into by logical judgement on the basis of abundant scientific knowledge and experience covering the whole of fire phenomena. The judgement of the cause should be made with fire-spreading situation at the spot as the central figure and in case of verifying, you are supposed to prove by the situational proof from the traces of the tire-spreading to the fire-outbreaking sources. The causal relation on a fire-outbreak should not be proved by arbitrary opinion far from concrete facts, and also there is much chance of making mistakes if you draw deduction from a coincidence. It is absolutely necessary you observe in an objective attitude and grasp the situation of a tire in the investigation of the cause. Having a look at the spot with a prejudice is not allowed. The source of tire-outbreak itself is likely to be considered as the cause of a tire and that makes us doubt about the results according to interests of the independent investigators. So to speak, they set about investigations, the police investigation in the hope of it not being incendiarism, the fire department in the hope of it not being problems in installments or equipments, insurance companies in the hope of it being any incendiarism, electric fields in the hope of it not being electric defects, the gas-related in the hope of it not being gas problems. You could not look forward to more fair investigation and break off their misgivings. It is because the firing source itself is known as the cause of a fire and civil or criminal responsibilities are respected to the firing source itself. On this occasion, investigating the cause of a fire should be conducted with research, investigation, emotion independent, and finally you should clear up the cause with the results put together.

  • PDF

화제사례 - 숭례문 화재사례 및 문화재 안전관리 대책

  • Lee, Yeong-Byeong
    • 방재와보험
    • /
    • s.125
    • /
    • pp.48-54
    • /
    • 2008
  • 어느 누구도 누군가가 숭례문의 담을 넘어가 불을 질러 무너뜨릴 것이라고 생각하지 못했다. 숭례문에 관련된 사람들뿐만 아니라 불을 지른 방화범도 이렇게 피해가 크게 될 것이라고 예상치 못했을 것이다. 2008년 2월 10일 20시 50분 숭례문에서 연기가 나오고 있다는 신고 후 모두의 염원과 노력에도 불구하고 약 5시간 후인 익일 2시 5분경 숭례문은 훨훨 타 지붕이 무너졌고 사람들은 멍하니 바라볼 수밖에 없었다. 모든 국민이 이번 화재사건을 안타까워하겠지만, 그중 가장 마음이 아픈 사람은 현장에서 활동하였던 소방관이 아닐까 라는 생각이 든다.

  • PDF

The Development of Reenactment System (사건 재연 시스템 개발)

  • 윤여천;변혜원;전성규
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.45-49
    • /
    • 2001
  • 본 논문에서는 실제 카메라 영상으로 획득하기 어려운 화재, 살인 등의 뉴스 사건을 시청자들에게 효과적으로 전달하기 위해서 다수의 가상캐릭터가 등장하는 애니메이션을 신속, 편리하게 제작할 수 있는 사건 재연 시스템의 개발 기법을 소개한다. 본 시스템은 미리 구축된 동작 및 모델 라이브러리를 이용하여 다수의 가상캐릭터 움직임을 제어함으로써 고가의 동작 포착 장비와 연기자가 없어도 신속한 가상캐릭터 애니메이션 제작이 가능하다. 사건 재연 시스템의 가상 캐릭터 동작 제어는 동작 지정, 동작 생성, 동작 편집의 세 단계로 구성된다. 동작 지정 단계에서는 사건 시나리오에 따라 모델 라이브러리부터 가상캐릭터와배경 모델을 선택하고, 동작 라이브러리부터 가상캐릭터의 동작을 선택한다. 동작 생성 단계에서는 지정된 특정 사건을 기술하는 동작에 이동 동작을 연결함으로써 가상캐릭터의 부드러운 동작을 생성한다. 동작편집 단계에서는 가상캐릭터 사이의 상호 작용 또는 가상캐릭터와 가상환경의 상호작용을 보다 정확하게 제어하기 위해서 특정한 시간에서의 가상캐릭터 위치와 자세 등을 조정한다. 본 시스템은 편리한 사용을 위해 대화형과 스크립트 기반의 인터페이스를 적용하였으며, 3차원 그래픽 소프트웨어인 Maya의 플러그인(Plug-in) 소프트웨어 형태로 개발하여 Maya의 고성능 그래픽 기능을 활용하였다.

  • PDF

5G service and universal service (5G시대 통신서비스의 공익성 제고 방안에 대한 모색)

  • Kim, Sung-Wook
    • Journal of Digital Convergence
    • /
    • v.18 no.2
    • /
    • pp.103-110
    • /
    • 2020
  • The fire incident of KT's Ahyun branch occurred last year indicates that hyper-connected society led by 5G technology would be a dystopia instead of a utopia unless seamless connection of 5G service is well secured. Looking backward on 1999, we could peacefully and happily greet the new millennium by making a great effort to prevent the millennium bugs(Y2K) from causing the catastrophe such as a shut-down of banking system. Likewise, we should make a great effort to keep 5G networks and 5G service continuously working without the disruption of even just a second, which would enable us to avoid facing any catastrophes caused by the disruption of 5G service. As a way to do so, it can be considered that 5G service is designated as universal service because it has the key features of public goods like telephone and high-speed internet services.

Edge Ontology for Fire Monitoring in Internet of Things (사물인터넷에서 화재 감시를 위한 엣지형 온톨로지)

  • Lim, Hyeryeong;Kim, Yujin;Jung, Inbum
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.343-345
    • /
    • 2020
  • 사물인터넷 시대에 스마트 홈들의 출현으로 엣지 지역에서의 정확한 화재 감지 및 대응 기술에 대한 필요성이 요구되고 있다. 그러나, 화재 감지 동작에서 오작동으로 인한 잘못된 정보를 제공하거나, 감지 기기로부터의 불충분한 정보 제공은 화재 감지/예방을 효과적으로 수행하기 어렵게 한다. 본 논문에서는 사물인터넷 엣지 지역에서 기존의 다양한 센서들을 통해 데이터를 수집하여 온톨로지에서 추론과정을 진행하는 엣지형 온톨로지 시스템을 구현한다. 본 논문에서는 추론된 정보를 바탕으로 사물인터넷 엣지에서 발생되는 화재 사건에 대한 정확한 판단할 수 있게 한다. 제안된 화재 추론 온톨로지를 이용해 기존의 화재감지기가 제공하는 정보 뿐 만 아니라 화재 정보에 대한 확장된 정보를 사용자에게 제공하므로 사용자 유용성을 개선될 수 있음을 보인다.

A Case of Sprinkler Non-Working by Programming Error (프로그래밍 오류에 의한 스프링클러 미작동 사례)

  • Seo, Young-Il;Cho, Young-Jin;Moon, Byung-Seon;Park, Jong-Jin;Park, Jong-Chan;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.116-120
    • /
    • 2008
  • According to the Fire Services Act revised in 2005, it has been required to set up sprinkler systems to all floors to the newly builded apartments having above 11 floors. But, according to the Fire Services Act before 2005, it had been required to set up sprinkler systems from 16 floors to the top floors to the apartments having above 16 floors. This case is the accident that a victim was dead by the fire which is inferred as an accidental fire by a cigarette butt in a 17th floor apartment unit in an apartment having 17th floors and that the bereaved family called in question why the sprinklers non worked at the fire. Through the field investigation, we checked that the sprinklers worked well when the fire detectors at the 16th floor of the apartment were operated and that the sprinklers non worked when the fire detectors at the 17th floor of the apartment were operated. We made clear that the cause of the sprinkler non-working at the 17th floor is the programming error of the sprinkler controller.