• Title/Summary/Keyword: 혼합열

Search Result 1,491, Processing Time 0.03 seconds

Estimation for the Exponential ARMA Model (지수혼합 시계열 모형의 추정)

  • Won Kyung Kim;In Kyu Kim
    • The Korean Journal of Applied Statistics
    • /
    • v.7 no.2
    • /
    • pp.239-248
    • /
    • 1994
  • The Yule-Walker estimator and the approximate conditional least squares estimator of the parameter of the EARMA(1, 1) model are obtained. These two estimators are compared by simulation study. It is shown that the approximate conditional least squares estimator is better in the sense of the mean square error than the Yul-Walker estimator.

  • PDF

PCR 방법에 의한 세균성 식중독균의 다중${\cdot}$동시 검출

  • Park, Ju-Yeon;Mun, Seon-Yeong;Lee, Gyeong-Ha;Nam, Jeong-Ok;Nam, Bo-Ra;Kim, Jin-Man
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.346-349
    • /
    • 2005
  • 병원성미생물을 분리${\cdot}$동정하는 방법으로 선택배지를 이용하는 검사방법은 4${\sim}$7일의 시간이 소요되는 단점이 있으며, 기존의 PCR방법은 대부분 단일 병원성 미생물만을 검출할 수 있는 반면 본 연구에서 사용된 시스템은 6종류의 세균성 식중독균을 한 번의 분석으로 확인할 수 있었기 때문에 비용과 분석시간을 대폭 절감하는 효과가 있었다. Fig. 1은 6종류의 세균성 식중독균이 혼합된 시료에 각각의 단일 프라이머를 이용하여 특이성을 확인한 결과이며, Fig. 2는 멀티플렉스 프라이머를 이용하여 각각의 세균성 식중독균 열 추출 시료에 대한 특이성을 확인한 결과이다. PCR 산물들이 사다리(ladder) 형태로 증폭됨으로써 동시에 6종류의 세균성 식중독균을 용이하게 확인할 수 있었다(Lane 1${\sim}$Lane 6). 또한 3종류의 세균성 식중독균이 혼합된 열 추출시료에서도 특이적인 PCR 증폭 산물들을 탐지할 수 있었다(Lane 10 & Lane 11).

  • PDF

Heat transfer of Mixed convection in rectangular space with constant heat flux (일정 열유속의 열원을 갖는 사각공간의 혼합대류 열전달)

  • 조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.552-558
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room numerical simulation with a standard k-$\varepsilon$model was carried out. In the present study the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with a downward angle depresses recirculation flow causing a strong stream in the wider space of the room Ventilation and removal of the released heat are promoted with this pattern, There is a possibility of local extreme heating at the upper surface of the engine when supply and exhaust ports of air are in bilateral symmetry.

  • PDF

Forced Ignition Characteristics with a Plasma Jet Torch in Supersonic Flow (초음속 유동장 내 플라즈마 토치를 사용한 강제 점화 특성)

  • Kim, Chae-Hyoung;Jeung, In-Secuk;Choi, Byoung-Il;Kouchi, Toshinori;Masuya, Goro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.363-366
    • /
    • 2011
  • Mixing and combustion experiments with a vent slot mixer were performed in Mach 2 supersonic wind tunnel. Helium and hydrogen gases each were used for the mixing and the combustion experiment with a plasma jet (PJ) torch. The vent slot mixer holds plenty of fuel in the downstream mixing region, even though the fuel is transversely injected. In case of the combustion, the injected fuel is ignited by the PJ torch, and then unburned mixture is burned by shock-induced combustion downstream. Thermal choking in the combustor leads to shock trains in the isolator, causing the unstable combustion.

  • PDF

Improved Thermoacoustic Model Considering Heat Release Distribution (열분포를 고려한 열음향 모델의 개선)

  • Kim, Daesik;Kim, Kyu Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.443-449
    • /
    • 2014
  • Thermoacoustic (TA) models have been widely used to predict combustion instability characteristics in a gas turbine lean premixed combustor. However, these techniques have shown some limitations in improving the model accuracy related to an over-simplification of the combustion system and flame geometry. Efforts were made in the current study to improve the limitations of the TA models. One strategy was to modify the actual flame location in the model, and another was to consider the heat release distribution through the flames. The modified TA model results show better accuracy in predicting the growth rate of instabilities compared with the previous results.

Applicability Evaluation of Methodology for Evaluating High Cycle Thermal Fatigue of a Mixing Tee in Nuclear Power Plants (원전 혼합배관 고주기 열피로 평가방법론의 적용성 평가)

  • Kim, Sun-Hye;Sung, Hee-Dong;Choi, Jae-Boong;Huh, Nam-Su;Park, Jeong-Soon;Choi, Young-Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.44-50
    • /
    • 2011
  • Turbulent mixing of hot and cold coolants is one of the possible causes of high cycle thermal fatigue in piping systems of nuclear power plants. A typical situation for such mixing appears in turbulent flow through a T-junction. Since the high cycle thermal fatigue caused by thermal striping was not considered in the piping fatigue design in several nuclear power plants, it is very important to evaluate the effect of thermal striping on the integrity of mixing tees. In the present work, before conducting detailed evaluation, three thermal striping evaluation methodology suggested by EPRI, JSME and NESC are analyzed. Then, a by-pass pipe connected to the shutdown cooling system heat exchanger is investigated by using these evaluation methodology. Consequently, the resulting thermal stresses and the fatigue life of the mixing tee are reviewed and compared to each other. Futhermore, the limitation of each methodology are also presented in this paper.

Thermoacoustic Analysis Model for Combustion Instability Prediction - Part 1 : Linear Instability Analysis (연소 불안정 예측을 위한 열음향 해석 모델 - Part 1 : 선형 안정성 해석)

  • Kim, Daesik;Kim, Kyu Tae
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.6
    • /
    • pp.32-40
    • /
    • 2012
  • For predicting eigenfrequency and initial growth rate of combustion instabilities in lean premixed gas turbine combustor, linear thermoacoustic analysis model was developed in the current paper. A model combustor was selected for the model validation, which has well-defined inlet and outlet conditions and a relatively simple geometry, compared to the combustor in the previous works. Analytical linear equations for thermoacoustic waves were derived for a given combustion system. It was found that the prediction results showed a good agreement with the measurements, even though there was underestimation for instability frequencies. This underestimation was more obvious for a longer flame (i.e. wider temperature distribution) than for a shorter flame.

Effects of Changes in Equivalence Ratio and Modulation Condition on Flame Transfer Function (당량비 및 섭동 조건 변화가 화염 전달 함수에 미치는 영향)

  • Kim, Dae-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.35-40
    • /
    • 2011
  • An experimental study of the flame response in a turbulent premixed combustor has been conducted in order to investigate mechanisms for combustion instabilities in a lean premixed gas turbine combustor. A lab-scale combustor and mixing section system were fabricated to measure the flame transfer function. Measurements are made of the velocity fluctuation in the nozzle using hot wire anemometry and of the heat release fluctuation in the combustor using chemiluminescence emission. The results show that the flame transfer functions are greatly dependent on the modulation frequency as well as operating conditions such as equivalence ratio. Flame dynamics can be generalized as a function of Strouhal number which is a ratio of flame length to modulation wave length.

Evaluation of Thermal Conductivity for Grout/Soil Formation Using Thermal Response Test and Parameter Estimation Models (열응답 시험과 변수 평가 모델을 이용한 그라우트/토양 혼합층의 열전도도 산정)

  • Sohn Byong Hu;Shin Hyun Jun;An Hyung Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.173-182
    • /
    • 2005
  • The Performance of U-tube ground heat exchanger for geothermal heat Pump systems depends on the thermal properties of the soil, as well as grout or backfill materials in the borehole. In-situ tests provide a means of estimating some of these properties. In this study, in-situ thermal response tests were completed on two vertical boreholes, 130 m deep with 62 mm diameter high density polyethylene U-tubes. The tests were conducted by adding a monitored amount of heat to water over a $17\~18$ hour period for each vertical boreholes. By monitoring the water temperatures entering and exiting the loop and heat load, overall thermal conductivity values of grout/soil formation were determined. Two parameter estimation models for evaluation of thermal response test data were compared when applied on the same temperature response data. One model is based on line-source theory and the other is a numerical one-dimensional finite difference model. The average thermal conductivity deviation between measured data and these models is of the magnitude $1\%$ to $5\%$.

Development of hybrid stochastic model for rainfall generation considering rainfall inter-annual variability (연간 강우 변동성을 고려한 혼합 추계 강우 생성 모형의 개발)

  • Park, Jeong Ha;Kim, Dong Kyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.11-11
    • /
    • 2018
  • 본 연구에서는 1시간부터 1년 단위의 강우 특성들을 잘 모의하는 혼합 추계 강우 생성 모형을 개발하였다. 본 모형의 가상 강우 생성 과정은 4단계로 이루어진다. 첫 단계에서 Seasonal ARIMA 모형을 통하여 시계열 특성을 반영한 월 강우를 생성한다. 두 번째 단계는 생성된 월 강우에 해당하는 일 단위 이하의 강우 통계치 세트를 생성하는 것이며, 통계치간 상관관계를 통해 평균, 표준편차, 자기상관 계수, 무강우 확률을 생성한다. 생성된 통계치 세트는 세 번째 단계에서 Modified Bartlett-Lewis Rectangular Pulse (MBLRP) 모형의 6개의 매개변수를 보정하는데 사용되며, 마지막으로 MBLRP 매개변수 세트를 통해 가상 강우 시계열을 생성한다. 위 모형을 통해 미국 동부 지역 29개 강우 관측소에 대하여 200년 길이의 가상 강우를 생성하였으며, 그 결과 시 단위부터 연 단위까지 강우의 1차, 2차 통계치 및 무강우 확률을 성공적으로 재현하였다. 또한 기존 MBLRP 모형에 비하여 극한 강우 사상을 재현하는 능력이 향상되었다. 빈도분석 결과를 통하여 MBLRP 모형이 재현기간에 따라 10%에서부터 40%까지 극한 사상을 과소 추정한 반면, 본 모형에서는 20% 이내의 값을 나타내었다.

  • PDF