• Title/Summary/Keyword: 호흡센서

Search Result 146, Processing Time 0.024 seconds

Design of Respiratory Sensor System for polysomnography using Thermocouple (Polysomnography를 위한 열전대 호흡센서 시스템의 설계)

  • 우용규;정도언;박광석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.121-123
    • /
    • 2000
  • Changes in breathing pattern and apnea both can be !he result of sleep disorders. The focus of this paper is to develop methodologies to monitor the breathing pattern and to detect apnea. An accurate recording of the respiratory phase can be carried out with different methods. One of these methods is the use of a thermocouple, which reacts to the variation in air temperature, placed in the nose and mouth of the patient. The K-type thermocouple was used because it has high reliability, thermo-stability, and good corrosion resistance. And also, it has a considerable long time constant that gives a low cut-off frequency, well below the respiratory frequency and thereby causing a large phase difference. The result showed that timing of respiration was accurately obtained with the AD595, amplifier for K-type thermocouple.

  • PDF

Implement the system for apnea patient (무호흡증 환자를 위한 시스템구현)

  • Ye, Soo-young;Eom, Sang-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.267-268
    • /
    • 2017
  • Obstructive sleep apnea in patients, between 70 and 80 percent, can be cured with just a posture correcting. It needed to know the current position information for correcting the position. The pressure sensors of the array type were used to obtain position information. These sensors can obtain information from the experimenter about position. In addition, air cylinder corrected the position of the experimenter by lifting the bed. The experimenter can be changed position without breaking during sleep by the system.

  • PDF

Affecting Factor Analysis for Respiration Rate Measurement Using Depth Camera (깊이 카메라를 이용한 호흡률 측정에 미치는 영향 요인 분석)

  • Oh, Kyeong-Taek;Shin, Cheung-Soo;Kim, Jeongmin;Jang, Won-Seuk;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.19 no.3
    • /
    • pp.81-88
    • /
    • 2016
  • The purpose of this research was to analyze several factors that can affect the respiration rate measurement using the Creative Senz3D depth camera. Depth error and noise of the depth camera were considered as affecting factors. Ambient light was also considered. The result of this study showed that the depth error was increased with an increase of the distance between subject and depth camera. The result also showed depth asymmetry in the depth image. The depth values measured in right region of the depth image was higher than real distance and depth values measured in left of the depth image was lower than real distance. The difference error of the depth was influenced by the orientation of the depth camera. The noise created by the depth camera was increased as the distance between subject and depth camera was increased and it decreased as the window size was increased which was used to calculate noise level. Ambient light seems to have no influence on the depth value. In real environment, we measured respiration rate. Participants were asked to breathe 20 times. We could find that the respiration rate which was measured from depth camera shows excellent agreement with that of participants.

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF

Design of FMCW Radar Signal Processor for Human and Objects Classification Based on Respiration Measurement (호흡 기반 사람과 사물 구분 가능한 FMCW 레이다 신호처리 프로세서의 설계)

  • Lee, Yungu;Yun, Hyeongseok;Kim, Suyeon;Heo, Seongwook;Jung, Yunho
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.4
    • /
    • pp.305-312
    • /
    • 2021
  • Even though various types of sensors are being used for security applications, radar sensors are being suggested as an alternative due to the privacy issues. Among those radar sensors, PD radar has high-complexity receiver, but, FMCW radar requires fewer resources. However, FMCW has disadvantage from the use of 2D-FFT which increases the complexity, and it is difficult to distinguish people from objects those are stationary. In this paper, we present the design and the implementation results of the radar signal processor (RSP) that can distinguish between people and object by respiration measurement using phase estimation without 2D-FFT. The proposed RSP is designed with Verilog-HDL and is implemented on FPGA device. It was confirmed that the proposed RSP includes 6,425 LUT, 4,243 register, and 12,288 memory bits with 92.1% accuracy for target's breathing status.

Improved Vapor Recognition in Electronic Nose (E-Nose) System by Using the Time-Profile of Sensor Array Response (센서 응답의 Time-Profile 을 이용한 전자 후각 (E-Nose) 시스템의 Vapor 인식 성능 향상)

  • Yoon Seok, Yang
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • The electronic nose (E-nose) recently finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. The odor recognition performance of E-nose can be improved by manipulating the sensor array responses of vapors in time-profile forms. The different chemical interactions between the sensor materials and the volatile organic compounds (VOC's) leave unique marks in the signal profiles giving more information than collection of the conventional piecemal features, i.e., maximum sensitivity, signal slopes, rising time. In this study, to use them in vapor recognition task conveniently, a novel time-profile method was proposed, which is adopted from digital image pattern matching. The degrees of matching between 8 different vapors were evaluated by using the proposed method. The test vapors are measured by the silicon-based gas sensor array with 16 CB-polymer composites installed in membrane structure. The results by the proposed method showed clear discrimination of vapor species than by the conventional method.

Web-based Healthcare System for effective medical information service management (효율적인 의료 정보 서비스 관리를 위한 웹 기반 헬스케어 시스템)

  • Her, Seung-Phil;Lim, Byong-In;Lee, Seung-Hyun;Shin, Dong-Ryeol
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.1421-1424
    • /
    • 2005
  • 본 논문은 통신 기술과 의료 센서 기술을 접목하여 일상생활에서 병원을 찾아가지 않고도 환자가 심전도, 호흡, 혈압 등을 측정 관리 할 수 있도록 한 헬스케어 시스템을 소개한다. 본 시스템을 통하여 환자 몸의 센서 데이터와 병원안의 시스템 사이에 체계적이 컴퓨팅 환경을 구축 할 수 있고, 더불어 환자가 자신의 상태의 효율적으로 관리할 수 있을 뿐 아니라 원격지의 의료진들이 환자의 상태를 모니터링 하고 응급상황 발생 시 그에 알맞은 최적의 의료 서비스의 제공이 가능해진다. 더불어, 웹을 통하여 진찰 및 치료를 제공 할 수 있도록 하여 인터넷이 가능한 곳이면 언제 어디서나 최적의 의료 서비스를 제공하고, 받을 수 있도록 하였다.

  • PDF

Real Time Driver's Respiration Monitoring (실시간 운전자 호흡 모니터링)

  • Park, Jaehee;Kim, Jaewoo;Lee, Jae-Cheon
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.142-147
    • /
    • 2014
  • Real time driver's respiration monitoring method for detecting driver's drowsiness is investigated. The sensor to obtain driver's respiration signal was a piezoelectric pressure sensor attached at the abdominal region of the seat belt. The resistance of the pressure sensor was changed according to the pressure applied to the seat belt due to the driver's respiration. Monitoring driver's respiration was carried out by driving on the virtual road in a driving simulator from Cheonan to Seoul and monitoring results were compared to the PELCLOS. Experiment results show that the driver's respiration signal can be used for detecting driver's drowsiness.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.