• Title/Summary/Keyword: 형광 곡선

Search Result 96, Processing Time 0.021 seconds

Picosecond Fluorescence Lifetimes of Hematoporphyrin Derivatives in Solutions and in vitro (용액 및 시험관 실험에서의 헤마토포르피린 유도체 분자의 피코초 형광수명시간 분석)

  • Kim, Hyun-Soo;Chu, Sung-Sil;Kim, Gwi-Eon;Lee, Won-Young;Kim, Ung
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.61-70
    • /
    • 1995
  • The picosecond time resolved fluorescence spectra of Hematoporphyrin Derivative (HPD) in both solutions and cancer cell are measured by a time correlated single photon counting system with a synchronously mode locked dye laser. Two exoponential decay components in the fluorescence spectra were observed. The slow decay(6.3 ㎱)and the fast one(350 ㎰)are attributed to be originated from monomers and dimers, respectively. The absorption and fluorescence measurements in steady state also showed the presence of a monomeric and dimeric forms of HPD molecules. The monomer lifetime in the cancer cell was measured to be longer than that in solution, which was expected from the blue shift and narrowing of the absorption spectra for HPD-treated in vitro. The relative amplitude of the fast component was found to be enhanced in cancer cell, strongly indicating the higher affinity of the dimer for the cancer cell.

  • PDF

A Study of the Thermoluminescent Properties of Korean Natural Quartz for Possible Use in Gamma-ray Dosimetry

  • Lee, Hee-Yong;Kim, Hi-Gyu;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.229-239
    • /
    • 1970
  • Various thermoluminescent properties of Korean natural quartz for possible use in ${\gamma}$-ray dosimetry has been studied. If the heating is exactly linear, ${\gamma}$-irradiated radiation sensitive (type 1) $\alpha$-quartz can yield a glow curve of single peak, hence glow peak height could be taken as a ${\gamma}$-dose for its dosimetry. Quartz crystal dosimeter exhibited the linearity of thermoluminescent intensity in the range from about 2$\times$10$^{3}$R to 2$\times$10$^{6}$ R, and also had an advantage of low fading because of the high peak temperature (300$\pm$4$0^{\circ}C$). The pulverized quartz sample having the grain size of 0.3<ø<0.9mm showed the linearity of T. L. intensity in the range from 50R to 2$\times$10$^3$R. Therapeutic application of the pulverized sample on the correct measurement of the absorbed dose in a body region of a cancer patient seems to be successful.

  • PDF

Thermoluminescence Kinetics of LYGBO Crystal (LYGBO 단결정의 열형광 전자포획준위 인자)

  • Sunghwan, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2023
  • In this study, the thermoluminescence kinetics of electron trap in Li6Y0.5Gd0.5(BO3)3 (LY0.5G0.5BO) scintillator for neutron detection composed of Li, Gd, and B with a high neutron response cross-section were investigated. The thermoluminescence glow curve of the LY0.5G0.5BO scintillation single crystal was measured and analyzed using the peak shape method, the initial rise method, and the machine learning algorithm to evaluate the physical parameters of the electron trap. The glow curve of the LY0.5G0.5BO scintillation single crystal consisted of a single peak. As a result of analyzing this peak, the activation energy, emission order, and frequency factor of the electron trap were 0.61 eV, 1.1, and 1.7×107 s-1, respectively. In addition, the possibility of thermoluminescence analysis of scintillators using machine learning was confirmed.

Shear Induced Homogenization Study of an Immiscible Polymer Blend Solution Using Fluorescence Microscope (형광 현미경을 이용한 비상용 고분자 블렌드 용액의 전단 균질화 연구)

  • 유재웅
    • Polymer(Korea)
    • /
    • v.27 no.5
    • /
    • pp.413-420
    • /
    • 2003
  • Fluorescence microscope technique was employed for the characterization of phase separation behavior of a 4-chloro-7-nitrobenzofurazan labeled polystyrene (PS) / polybutadiene (PB) blend in dioctyl phthalate under steady shear. It was confirmed that the fluorescence microscope images reflect the real phase morphology by comparing with the images of phase contrast microscope. Comparing the fluorescence intensities from the phase separated domain (PS rich) and continuous phase (PB rich), the composition difference between these two phases were deduced. The observed shear dependence of compositional change is then used to confirm that the phase diagram is indeed shifted under the steady shear.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Determination of Inverter Circuit Parameters of Electronic Ballasts for Dimming Compact Fluorescent Lamps (콤팩트 형광램프용 Dimming형 전자식 안정기의 회로정수 결정)

  • 곽재영;송상빈;여인선
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.29-34
    • /
    • 1995
  • 본 논문에서는 콤팩트 형광램프용 Dimming형 전자식 안정기의 설계에 있어서, 인버터 공진탱크의 커패시턴스값을 변화시킬 때 전압이득곡선을 분석하여 최적의 회로정수를 결정하는 방법을 제안하였다. 또한 하프브리지 인버터회로의 회로정수에 대한 PSpice 시뮬레이션을 행하여 램프전압과 전류값을 구하였고, 실제 전자식 안정기를 제가하고 시동특성과 조광특성을 비교분석하였다. 시동특성은 일반 전자식 안정기와 거의 동일하였으며, 조광특성은 전체 광출력의 5%까지 안정동작되어, 제안된 방법이 뛰어남을 확인하였다.

  • PDF

Effect of Temperature on the Luminous Properties of Remote-Phosphor White Light-Emitting Diodes (이격 형광체 구조가 적용된 백색 LED 광원의 온도변화에 따른 발광 특성 분석)

  • Choi, Min-Hyouk;Lee, Hun Jae;Ko, Jae-Hyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.254-261
    • /
    • 2014
  • Two types of white light-emitting diodes (LEDs) with different phosphor structures were fabricated and compared in terms of their optical characteristics. Their spectroscopic properties were analyzed as a function of temperature, from room temperature to $80^{\circ}C$. The temperature dependence of the luminance and the color coordinates showed that the decrease in luminance and change in the color coordinates of the remote-phosphor type LED were much smaller compared to the conventional white LED. These improvements were attributed to the decrease in phosphor temperature, due to the distance between the LED chip and the phosphor layer, as well as to the reduced absorption by the LED chip of the light emitted from the phosphor layer.

Measurement of fluorecence decay times of single molecules in solution (용액내 단분자의 형광소멸시간 계측)

  • 고동섭
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.1-4
    • /
    • 1999
  • A confocal microscope system was used to study the bursts of fluorescence photons from single dye molecules excited at 638 nm by a short-pulsed diode laser with a repetition rate of 17 MHz. A red dye, JA22, in ethylene glycol solution was used as a sample. The fluorescence decay curves of single molecules were acquired using a time-correlated single photon counting and analyzed by a maximum likelihood estimator. It was possible to measure the fluorescence decay times with an error probability of 21% at photon number of more than 40 per dye molecule.

  • PDF

Natural Beryl as a Thermoluminescent Dosimeter

  • Moon, P.S.
    • Nuclear Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.151-154
    • /
    • 1974
  • The possibility of using natural beryl thermoluminesence for gamma-ray dose measurement was investigated through the analysis of glow curves obtained with Co-60 gamma-ray irrediation. The natural beryl powder of 80-200 mesh has a good gamma-ray thermoluminescent response and stability at room temperature. The thermoluminescent response is linear from 10mR to 10$^3$R and can be measured up to 10$^{6}$ R.

  • PDF

Optical characteristics of Nd:LSB microchip laser device (Nd:LSB 마이크로칩 레이저 광소자의 광학 특성)

  • Jang, Won-Kweon;Park, Jong-Seon;Kim, Tong-Yol;Yu, Young-Moon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.965-967
    • /
    • 2003
  • Czochralski pulling method에 의해 성장된 고농도 도핑 Nd:LSB의 광학적 특성을 조사하였다. 결정 성장조건에 의해 달라지는 space group은 지금까지 C2/c, R32, Cc와 C2등 4가지가 보고되었으며, 기본적으로 6방정계의 구조를 가지고 비선형 광학 결정으로서의 특성을 보였다. x선 회절 분석계를 이용하여 구조를 분석하였고, 도핑 농도에 따른 형광 수명의 변화, 분산곡선 특성을 조사하였다. 또한 흡수 및 저온 형광 스펙트럼을 이용하여 도핑 농도 및 space group의 변화에 따른 에너지 준위의 변화를 관찰하고 비교하였다.

  • PDF