• Title/Summary/Keyword: 혈액오염

Search Result 96, Processing Time 0.031 seconds

A STUDY OF SHEAR BOND STRENGTH OF ORTHODONTIC BRACKET UNDER BLOOD-CONTAMINATED CONDITIONS (혈액 오염 환경 하에서 접착된 교정용 브라켓의 전단 강도에 관한 연구)

  • Shin, Ji-Sun;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.191-199
    • /
    • 2005
  • This study was experienced in order to obtain the shear bond strength of orthodontic bracket adhesives under the blood contamination that can be occurred during the procedure of bracket bonding under window opening surgery. As a result of this study, shear bond strength of all glass ionomer groups were lower than resin cement groups. However, the strength of uncontaminated and post-contaminated group of glass ionomer was strong enough to perform an orthodontic forced eruption. This study revealed that during a window opening surgery, glass ionomer without etching procedure is available in order to bond a bracket if surface of teeth is not pre-contaminated by blood before the adhesive application. Both simple procedure and less adhesives remnant after bonding failure could make light-cured glass ionomer cement the ultimate choice for racket bonding.

  • PDF

Effect of Blood Contamination on the Push-Out Bond Strength and Surface Morphology of Tricalcium Silicate Materials (혈액오염이 Tricalcium Silicate 재료의 압출강도와 표면형태에 미치는 영향)

  • Park, Misun;Kim, Jaehwan;Choi, Namki;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.36-43
    • /
    • 2016
  • The aim of this study was to evaluate the effect of blood contamination on the push-out bond strength and surface morphology of tricalcium silicate materials; Biodentine$^{(R)}$, Theracal$^{(R)}$ and mineral trioxide aggregate. The standardized lumens of root slices prepared from extracted single-root human teeth were filled with Biodentine$^{(R)}$, Theracal$^{(R)}$ and mineral trioxide aggregate by manufacturer's instruction. The specimens were randomly divided into 2 groups (n = 20) for each material and then incubated for 4 days at $37^{\circ}C$; control group (phosphate buffered saline solution) and experimental group (fetal bovine serum). The push-out bond strengths were then measured by a universal testing machine and the surface morphology of each experimental group was analyzed by scanning electron microscope. Biodentine$^{(R)}$ and Theracal$^{(R)}$ showed higher push-out bond strength compared with mineral trioxide aggregate after exposure to fetal bovine serum. A substantial change in the surface morphology of each material was observed after exposure to fetal bovine serum. In conclusion, the push-out bond strengths of Biodentine$^{(R)}$ and Theracal$^{(R)}$ were higher than mineral trioxide aggregate when exposed to blood contamination. Therefore, it is supposed that the use of Biodentine$^{(R)}$ and Theracal$^{(R)}$ is appropriate in the presence of blood.

Clinical Characteristics Associated with Blood Culture Contamination in Neonates (신생아에서 혈액 배양 오염과 관련된 임상적 특징)

  • Jung, Min Young;Son, Ok Sung;Hong, Yoo Rha;Oh, Chi Eun
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.3
    • /
    • pp.147-153
    • /
    • 2015
  • Purpose: This study was aimed to investigate the contamination rates of blood culture in a neonatal intensive care unit (NICU) and to examine the clinical characteristics related to the contamination. Methods: Eight hundred thirty cases of blood culture performed from March 2013 to February 2014 were analyzed. We evaluated the contamination rates of blood culture by blood sampling sites and compared the clinical characteristics such as real name system and body weights of the contaminated cases and those of non-contaminated ones. The clinical characteristics were retrospectively reviewed by medical records. Results: The overall contamination rate was 3.6% (30/830). The contamination rates by blood sampling sites were as follows: peripheral vein 15.6% (10/64), peripheral artery 2.6% (20/759), and umbilical arterial catheter 0% (0/7). There was no difference in the contamination rates between cases with and without real name system (P=0.484). However, there were significant differences in the contamination rates by the physicians who performed the culture (P=0.038) and body weight (<1,000 g vs. ${\geq}1,000g$) at the time of blood culture (P<0.001). Conclusions: These results suggest that neonates with a body weight less than 1,000 g have more risks of the contamination of blood culture. Furthermore, there is a necessity to provide blood culture performers with active feedbacks and individualized education plans that can help diminish blood culture contamination rates. Prospective studies in a systematic manner that can be applied in actual clinical settings are needed in order to figure out factors that can diminish the contamination rates of blood culture in NICU.

혈액제제 충분히 안전하다

  • 서동희
    • RED RIBBON
    • /
    • s.55
    • /
    • pp.16-17
    • /
    • 2003
  • 올해는 어느 해보다 수혈관련 사건이 많이 일어났다. 그 여파로 오염된 혈액이 혈액제제로 사용됐음을 문제삼는 기사가 유난히 많았던 한 해였다. 언론에서 보도하는 것처럼 혈액제제는 정말 신뢰할 수 없는 것인가?

  • PDF

Comparison of Bonding Strength by Cleaning Method of Pediatric Zirconia Crown Contaminated with Saliva or Blood (타액 및 혈액오염 시 유치 지르코니아 기성관 내면의 세척 방법에 따른 결합강도의 비교)

  • Kim, Jaeyong;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.2
    • /
    • pp.185-194
    • /
    • 2018
  • The objective of this study was to compare the shear bonding strength of zirconia after cleaning the crown contaminated by saliva or blood and determine the effect of thermocycling. 180 specimens were embedded in acrylic resin. 20 Specimens in the positive control group were bonded with resin cement without contamination. 20 Specimens in the negative control group were washed with water for 20 seconds and then dried for 10 seconds. 120 Specimens contaminated by saliva or blood were cleaned by using three cleaning methods: 37% phosphoric acid gel, commercial cleanse, and 2.5% NaOCl. All samples were bonded with resin cement and divided into two subgroups: One was not aged, and the other was tested with 30,000 thermocycling. In both groups contamination by saliva and blood, no statistically significant difference was not found in control, groups cleansed by commercial cleanser and 2.5% NaOCl. When the groups cleansed with water and 37% phosphate gel were compared with the control, significantly low shear bond strength was shown. Thermocycling group showed statistically significantly low shear bond stress compared to the groups without thermocycling. When zirconia was contaminated by saliva or blood, its original shear bond strength could be obtained if it was cleaned with commercial cleanser or 2.5% NaOCl.

Aroclor 1254 와 Hexachlorobenzene에 의한 나일틸라피아, Oreochromis niloticus의 혈액화학적 변화

  • 조규석;강주찬;민은영;김성길
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2000.10a
    • /
    • pp.264-265
    • /
    • 2000
  • 수계환경의 오염 실상을 파악하기 위해서 어류의 혈액화학적 변화는 수중의 오염물질에 의해서 그 구성이 변동되므로, 수계환경의 오염수준을 감시하는 유용한 수단으로 활용되고 있다(Khattak and Hafeez, 1996). PCBs(Polychlorinated biphenyls)는 열에 안전하고 전기 절연성이 좋은 특성을 가지고 있어 1929년부터 미국의 Monsanto사에서 Arochlor란 이름으로 시판되어 상업적으로 이용되기 시작하였다(Hutzinger. et al., 1986). (중략)

  • PDF

SHEAR BOND STRENGTH OF SELF-ETCHING PRIMER SYSTEMS TO CONTAMINATED DENTIN IN PRIMARY TEETH (오염된 유치 상아질에 대한 자가 부식 프라이머의 결합강도에 관한 연구)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eup
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.107-114
    • /
    • 2002
  • The purpose of this study was to determine and compare the shear bond strength of two self-etching primer systems to primary teeth contaminated with saliva and blood. Clearfil SE Bond and AQ Bond were evaluated. One hundred specimens were made by seventy-five deciduous teeth(fifty anterior and twenty-five posterior teeth) and divided randomly into ten groups. Small flat dentinal surfaces were prepared by grinding the buccal, lingual and labial areas. Specific surface treatments were applied to each group: (1) a self-etching primer application(control group), (2) saliva contamination followed by primer(Group I), (3) primer curing followed by saliva contamination (Group II), (4) blood contamination followed by primer(Group III), (5) primer curing followed by blood contamination(Group IV). After bonding of composite resin(Z100, 3M, USA) to contaminated sample surfaces and thermocycling(1,000 cycles), shear bond strengths were measured using Universal Testing Machine(Zwick Z020, Zwick Co., Germany). The results were as follows; 1. Group I showed lower shear bond strength than control group but no statistically significant difference was found(P>0.05). 2. Group II and blood contamination group(Group III & IV) showed significantly lower shear bond strength than control group(P<0.01). 3. The shear bond strength of Clearfil SE Bond was significantly higher than that of AQ Bond(P<0.05).

  • PDF

긴급진단-AIDS 최선의 예방책을 알아본다

  • Sin, Yeong-O
    • 건강소식
    • /
    • v.11 no.6 s.103
    • /
    • pp.28-30
    • /
    • 1987
  • 혈액등 체액이 접촉되는 성 활동과 수혈등 혈액 오염으로 감염되므로 이를 피하여야 한다. 감염가능성이 있는 대상자와의 성생활을 피해야 하며 부득이한 경우 콘돔의 사용이 요구된다.

  • PDF

Benzopyrene에 노출된 광어(Conger myriaster) 혈액 cells과 개조게(Saxidomus purpurata) 조직 cells을 이용한 in vivo DNA single strand breakage

  • 김소정;오로라;하병혁;최은석;장만;이택견
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2002.11a
    • /
    • pp.145-153
    • /
    • 2002
  • 유해 화학 물질류에 의해 오염된 해양 환경 시료의 환경독성 수준을 평가하기 위하여 다양한 화학물질에 대해 민감성이 우수한 생물학적 독성평가기법을 개발 하고자하였다. 지속성 유기오염 물질 중 다환 방향 족 탄화수소(PAHs)를 처리한 광어(Conger myriaster)와 개조개(Saxidomus pupurata)의 DNA 손상정도를 single cell gel electrophoresis assay(comet assay)를 통해 분석하였다. PAHs 중 광양만에서 높은 농도로 검출되는 benzo(a)pyrene을 농도별(0, 10, 50, 100 ppb)로 처리한 후 2일과 4일에 광어의 혈액세포와 개조개의 근육세포를 채취해 comet assay를 실시하였다. benso(a)pyrene에 대한 DNA 손상정도를 처리된 농도와 생물종에 따라 다르게 나타났는데 광어의 혈액세포는 2일에 가장 DNA 손상정도가 높았고, 4일에는 회복되는 경향을 나타냈다. 개조개의 근육세포는 시간이 지나면서 DNA 손상정도가 증가하는 경향을 보였다. 이와 같은 결과는 comet assay 기법이 유해 화학물질로 오염된 해양생물 종의 환경독성을 검색하는 유용한 수단이 될 수 있음을 보여준다.

  • PDF

Effect of Blood Decontamination on Orthodontic Bracket Bonding (혈액 오염 처리 과정이 교정용 브라켓 접착에 미치는 영향)

  • Lee, Jaehee;Shin, Jisun;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.341-349
    • /
    • 2017
  • Blood decontamination is an important factor in success of the orthodontic bracket. The purpose of this study is to evaluate the shear bond strength affected by blood decontamination. The shear bond strength was measured on blood decontamination before and after primer photopolymerization. And the adhesive remnants type and surface patterns was evaluated under scanning electron microscopy. A total of 50 human premolars were prepared. Group I was attached using conventional resin-acid etching method as control group. Group II and III were blood contaminated before curing primer and groups IV and V were blood contaminated after curing primer. Group II and IV were treated only with cotton pellet and Groups III and V were treated with cotton pellet after water washing. The mean shear bond strengths were in the order of groups I, V, III, II, and IV. In scanning electron micrographs group III and V showed more uniform surface than group II and IV. The ARI was significantly different between the control group and the experimental groups (p <0.05).