• Title/Summary/Keyword: 혈당측정

Search Result 461, Processing Time 0.019 seconds

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

Development of the Blood Glucose Strip for the Detection of Glucose in Blood (혈당 측정용 스트립 개발에 관한 연구)

  • 송은영;김경아;이홍수;권두한;남효진;김희정;변시명;정태화
    • Biomedical Science Letters
    • /
    • v.4 no.2
    • /
    • pp.103-112
    • /
    • 1998
  • We have developed a simple and accurate strip test that measures the blood glucose level semiquantitatively by visual observation, or qualitatively by using UltraScan spectrocolorimeter. The strip has solid phase reagents, including glucose oxidase, peroxidase, chromogen, affixed to a plastic support. The strip test is capable of measuring blood glucose level in the range of 0∼800 mg/dl and generating the results within 2 to 3 minutes. Human blood specimens obtained from normal individuals and the diabetic patients were evaluated by the new blood glucose strip and by the kit supplied by other commercial products. The test results exhibit the correlation coefficient of 0.964. The new test strip is proven simple and accurate, and it offers an alternative to the commercially available glucose tests.

  • PDF

Blood Glucose Measurement and Management System using a Smart Band and an App (스마트 밴드와 앱을 이용한 혈당 측정 및 관리 시스템)

  • Jeon, Yeongjun;Park, Yujin;Kang, SoonJu
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.6
    • /
    • pp.371-378
    • /
    • 2017
  • In modern society, awareness of diabetes is growing with an increase in the elderly population and an increase in the incidence of diabetes. In particular, diabetic patients can suddenly develop hypoglycemic shock; therefore, it is important to measure blood glucose periodically. However, self-monitoring blood glucose meters are difficult to carry and it is difficult to manage the value. To solve these problems, the blood glucose measurement system has been developed as a sensor attached to the body or as one of the functions of smart devices, but it has not been commercialized. In this paper, we propose a smart band with a blood glucose measurement function. If a user enters a schedule to measure blood glucose level, such as before/after meals, in the app, he/she can receive a measurement alarm from the band. The user can measure the blood glucose level at any time using the band, and the measured value is transmitted and managed by the app including behavior history such as before/after meals and the time. This will help the user to manage, diagnose and prevent health problems. The system has been tested using two medical device-certified products, and each blood glucose measurement value has been confirmed to be more accurate.

당뇨병 돋보기 IV - 공복혈당 VS 식후혈당

  • Kim, Yeong-Geon
    • The Monthly Diabetes
    • /
    • s.212
    • /
    • pp.59-61
    • /
    • 2007
  • 당뇨병은 발병 후 거의 완치가 불가능한 질환으로 당뇨병의 치료는 고혈당에 의한 증상을 개선, 여러 가지 급성 및 만성합병증을 예방하는 데 그 목적이 있다. 당뇨병 조절 및 합병증 연구 등에서 엄격한 혈당조절을 통해 당뇨병의 만성합병증이 예방되거나 이미 발생된 합병증도 진행이 지연됨이 알려졌으며, 이에 따라 지속적인 혈당조절의 필요성이 더욱 중요해지고 있다. 지속적인 혈당조절을 위한 당뇨병관리의 기준이 되는 지표에는 여러 가지가 있지만 그 대표적인 것으로 공복혈당, 식전혈당. 식후 2시간 혈당, 당화혈색소 등이 있다. 환자들은 어떤 검사가 나의 혈당변화를 가장 정확히 나타내 주는지 궁금할 때가 있다. 또한 혈당검사를 하루 중 언제 측정해야 가장 정확하고, 얼마나 측정해야 하는지도 궁금하다. 여기서는 혈당조절의 지표가 되고 합병증 예방의 가장 기초가 되는 검사의 종류와 검사 시기, 빈도를 알아보고자 한다.

  • PDF

Comparison of blood glucose concentrations from capillaries and veins in SMBG (자가혈당측정시 채혈방법에 따른 혈당치의 비교)

  • 김진학
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.1
    • /
    • pp.143-147
    • /
    • 1998
  • 당뇨병환자의 자가혈당조절에 있어서의 기준이 되는 혈당측정에 있어서 하나의 지침을 제공하기 위해 본 연구는 말초혈관과 상완정맥에서의 혈액을 채취하여 이들 검사물들의 혈당치를 직접적으로 비교했다. 30명의 건강한 한국인 성인 남자(연령 : 평균=30세)로부터, 공복시의 혈액을 세가지의 서로 다른 방법들(우선 손가락 끝에 말초혈관을 울혈이 되도록 한 뒤에, 이후 같은 편의 팔의 상완정맥에서, 마지막으로 다시 처음 검채를 시행했던 바로 그 말초의 천자부위에서 혈액을 짜내는 방법으로.)로 각각의 대상에서 검채하였다. 검사물들의 혈당치는 간편측정용 혈당측정기(Glucocard, KDK Corp., Japan. 1995)로 측정한 결과 상완정맥에서 채취한 혈액의 혈당치(107.58$\pm$21.03mg/dl)가 말초에서 채취한 혈액(울혈 후 : 100.21$\pm$24.03mg/dl, .짜낸 경우 : 97.84$\pm$22.45mg/dl)들 보다 높았다(T=2.86. p=.0081 : T=3.084. p=.0055). 그러나 이 결과는 기타의 연구들에서의 결과와는 일치하지 않았다. 이러한 불일치는 자가혈당측정기가 인슐린 의존형 당뇨환자는 물론이고 비의존성 당뇨환자들의 자가관리에 결정적인 지침이 된다는 점을 고려할 때, 좀 더 통제된 상황에서 더욱 많은 사람을 대상으로 한 임상시험을 통해 자가 혈당측정치에 있어서 기계요인에 대한분석이 이루워질 필요를 시사하고 있다. 또한 동일한 부위에서 서로 다른 방법들(혈관을 울혈을 시킨 천자하여 얻은 경우와 천자 후 그 부위를 짜서 검사물을 얻는 방법)에 의해서 얻어진 혈액의 헐당치 측정 결과 간에 차이가 없는 것으로 나타나서(t=0.72, p=.4791), 일반적으로 혈당치의 측정 시 검채한 양이 부족할 때, 새로이 천자하여 검사를 시행하는 것을 원칙으로 인식하고 있으나 본 연구결과를 볼 때, 이러한 채혈의 방식에 의한 차이는 환자의 안녕의 차원에서 고려하여 필요하다면 간과될 수도 있음을 의미하고 있다.

  • PDF

Development of a portable device for the measurement of urea concentration and glucose concentration in blood (혈중요소 및 혈당농도 측정을 위한 휴대용 측정기 개발)

  • Yoo, Jae-Tack;Lee, Dong-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.28-32
    • /
    • 2003
  • 본 논문은 시료의 양을 최소화하고 혈중 요소 및 혈당 농도에 대한 정확한 측정을 위하여 최근에 개발된 전기화학형 마이크로 전극형 센서의 간략한 소개 및 전기적인 특성에 관하여 요약하는 것에서 출발하여 센서로부터 전기신호를 발생시키는 signal conditioning 회로의 설계, microprocessor를 이용한 digital 값으로의 변환 및 data 취득, 취득한 data를 측정된 혈당량 및 요소량으로의 변환 저장 display까지의 휴대용 계측기의 prototype 개발에 관하여 기술한다. 이 계측기는 미량의 혈액채취 한번으로 농도를 측정하는 측정모드와, 측정된 data를 찾아보기 위한 검색모드로 작동시킬 수 있다. Microprocessor의 기능을 최대한 사용하여 측정기의 크기를 소형화하였으며 LCD(Liquid crystal display)틀 채택하는 등 저전력 회로로 구현하였다.

  • PDF