• Title/Summary/Keyword: 혈관 폐쇄 기구

Search Result 12, Processing Time 0.03 seconds

Endovascular Revascularization for Aortoiliac Occlusive Disease (대동맥-장골동맥 폐쇄성 질환의 혈관 내 재개통술)

  • Myungsu Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.512-526
    • /
    • 2021
  • Peripheral arterial disease is an occlusive condition commonly involving the lower extremity vessels. When the aortoiliac region is affected by this disease, conventional management involves surgical bypass and endovascular treatment has been mainly recommended for patients with focal and simple lesions. It has been common strategy to perform endovascular treatment for selected patients with high surgical risk due to its minimally invasive nature. However, recent advances in the devices and techniques for endovascular treatment have resulted in its utilization for treating patients with various disease status and its clinical outcomes are comparable to those of conventional surgery. This review discusses the current diagnostic strategies for peripheral artery disease in the aortoiliac region, followed by the introduction of techniques and devices, and the role of endovascular treatment.

The efficacy and safety of transcatheter closure of atrial septal defect with Amplatzer septal occluder in young children less than 3 years of age (3세 미만 심방중격결손 소아에서 Amplatzer 기구 폐쇄술의 안전성 및 효용성)

  • Lee, Soo Hyun;Choi, Deok Young;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.494-498
    • /
    • 2009
  • Purpose : Applicability of transcatheter closure of atrial septal defect (ASD) has been expanded by accumulation of clinical experiences and evolutions of the device. This study was performed to evaluate the safety and efficacy of transcatheter closure of ASD with Amplatzer septal occluder (ASO) in young children less than 3 years of age. Methods : From May 2003 to December 2005, 295 patients underwent transcatheter closure of ASD with ASO in the Severance Cardiovascular Hospital, Yonsei University Health System. Among them, 51 patients less than 3 years of age were enrolled in this study. We investigated procedural success rate, rate of residual shunt, frequency of complications, procedure/fluoroscopy time, and need of modified techniques for device implantation. Results : The median age was 2.1 years and median body weight was 12 kg. Implantation of device was successful in 50 patients (98%). Seven patients (15%) showed a small residual shunt 1 day after the procedure, but complete occlusion had been documented at 6 month follow-up in all patients (100%). The pulmonary to systemic flow ratio (Qp/Qs), peak systolic pulmonary artery pressure, and peak systolic right ventricular pressure had decreased significantly after closure of ASD. There were 2 complications including device embolization (1, 2%) and temporary groin hematoma (1, 2%). Conclusion : Transcatheter closure of ASD with ASO can be performed with satisfactory results and acceptable risk even in young children less than 3 years of age. We could suggest that even in very young children with ASD, there is no need to wait until they grow to a sufficient size for the transcatheter closure.

Video-Assisted Thoracoscopic Surgery for Patent Ductus Arteriosus - 6 cases report - (흉강경을 이용한 동맥관 개존증 수술- 6례 보고 -)

  • Park, Chan-Beom;Kwon, Jong-Bum;Won, Yong-Soon;Park, Kuhn;Park, Kyu-Ho
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.351-355
    • /
    • 2001
  • 개흉술에 의한 수술적 폐쇄방법 및 경도관 동맥관 폐쇄술은 동맥관 개존중의 치료방법으로 발전되어 왔으나, 이러한 술식은 개흉술에 의한 합병증, 지속적인 단락 및 용혈의 가능성, 기구의 이동이나 색전증의 발생, 지속적인 단락시 세균성 심내막염 방지를 위한 지속적인 항생제 사용등의 단점이 있어 저자들은 흉강경을 이용한 수술을 시행하였다. 총 6례의 환자에서 흉강경을 이용한 동맥관 개존증 수술을 시행하였으며. 이중 대동맥 외막(adventitia) 박리중 지형이 잘 되지 않았던 1례에서는 소개흉술(minithoracotomy)로 전환하였다. 술 후 이시행한 이학적 검사상에서 모든 환아에 심잡음이 소실되었음을 확인할 수 있었으며, 흉부 방사선 검사상 점진적인 폐혈관음영의 감소를 관찰할 수 있었으며 수술중 동맥관 파열이나 불완전한 동맥관 폐쇄, 기흉, 애성(hoarseness) 등의 합병증은 발생되지 않았다. 환아들은 술후 평균 3.4일째 퇴원하였으며, 퇴원후 외래추적 관찰검사시 시행한 심초음파 검사상 동맥관의 재개통이나, 잔류단락은 관찰되지 않았다. 본원에서는 개흉술 및 경도관 동맥관 폐쇄술의 단점을 방지할수 있으며, 성공적인 동맥관 폐쇄, 작은 피부절개 반흔에 의한 미용적 효과, 짧은 재원기간등의 장점을 가진 흉강경을 이용항 동맥관 결찰술을 시해앟여 문헌 고찰과 함께 보고하는 바이다.

  • PDF

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.

Biocompatibility and Histopathologic Change of the Acellular Xenogenic Pulmonary Valved Conduit Grafted in the Right Ventricular Outflow Tract (우심실 유출로에 이식한 무세포화 이종 폐동맥 판막도관의 생체 적합성 및 조직병리학적 변화양상에 대한 연구)

  • 허재학;김용진;박현정;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.482-491
    • /
    • 2004
  • Background: The xenogenic or allogenic valves after in Vitro repopulation with autologous cells or in vivo repo-pulation after acellularization treatment to remove the antigenicity could used as an alternative to synthetic polymer scaffold. In the present study, we evaluated the process of repopulation by recipient cell to the acellu-larized xenograft treated with NaCl-SDS solution and grafted in the right ventricular outflow tract. Material and Method: Porcine pulmonary valved conduit were treated with. NaCl-SDS solution to make the grafts acellularized and implanted in the right ventricular outflow tract of the goats under cardiopulmonary bypass. After evaluating the functions of pulmonary valves by echocardiography, goats were sacrificed at 1 week, 1 month, 3 months, 6 months, and 12 months after implantation, respectively. After retrieving the implanted valved conduits, histopathologic examination with Hematoxylin-Eosin, Masson' trichrome staining and immunohistochemical staining was performed. Result: Among the six goats, which had been implanted with acellularized pulmonary valved conduits, five survived the expected time period. Echocardiographic examinations for pulmonary valves revealed good function except mild regurgitation and stenosis. Microscopic analysis of the leaflets showed progressive cellular in-growth, composed of fibroblasts, myofibroblasts, and endothelial cells, into the acellularized leaflets over time. Severe inflammatory respon-se was detected in early phase, though it gradually decreased afterwards. The extracellular matrices were regenerated by repopulated cells on the recellularized portion of the acellularized leaflet. Conclusion: The acellularized xenogenic pulmonary valved conuits were repopulated with fibroblasts, myofibroblasts, and endothelial cells of the recipient and extracellullar matrices were regenerated by repopulted cells 12 months after the implantation. The functional integrity of pulmonary valves was well preserved. This study showed that the acellularized porcine xenogenic valved conduits could be used as an ideal valve prosthesis with long term durability.

Mitral Valvuloplasty using New Mitral Strip (Mitracon^{(R)}$) (새로운 Strip (Mitracon^{(R)}$)을 이용한 승모판막 성형술)

  • Kang, Seong-Sik;Kim, Sang-Pil;Song, Meong-Gum
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.320-328
    • /
    • 2008
  • Background: Numerous surgical devices for mitral repair have been used in the past with good results. In this study we describe a simple annuloplasty technique with using a new device ($Mitracon^{(R)}$). The aim of this study was to assess its efficacy and surgical results with using $Mitracon^{(R)}$. Material and Method: From May 2003 to October 2005, 46 patients (21 women and 25 men (mean age of $51.4{\pm}17.8$ years) with mitral regurgitation from various causes were treated with either the $Mitracon^{(R)}$ (the $Mitracon^{(R)}$ group) or the Capentier Edward rigid ring (the CE group). The median follow-up duration was 18.9 months. Result: The mean grade of mitral regurgitation before and immediately after surgery in the $Mitracon^{(R)}$ group and the CE group decreased from $3.2{\pm}0.8$ to $0.6{\pm}0.7$ and $3.4{\pm}0.7$ to $0.3{\pm}0.5$, respectively. There were no significant changes in the ejection fraction either between the two groups or before and immediately after surgery. No deaths were seen in either group. Early postoperative echocardiography of all 46 patients showed only trivial mitral regurgitation or none at all. Echocardiography at a median of 18.9 months also showed no progression in mitral regurgitation. The mean grade of mitral regurgitation in the $Mitracon^{(R)}$ group at this time point decreased from $3.2{\pm}0.8$ to $0.8{\pm}0.7$ (p<0.05). The CE group also showed a similar degree of decrease from $3.4{\pm}0.7$ to $0.3{\pm}0.6$ (p<0.05). The mitral valve area in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.3{\pm}0.9cm^2$. The mitral valve area in the CE group was $2.7{\pm}0.6cm^2$. The mean mitral pressure gradient in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.1{\pm}1.3$ mmHg. The mean pressure gradient in the CE group was $4.5{\pm}2.1$ mmHg, although any statistical significant difference for this between the groups was not reached. Conclusion: The present study showed the described technique to be safe and effective in the intermediate term. Because long term results are unavailable, a more extensive prospective randomized multicenter trial may be warranted to determine whether this procedure should be generally applied for repair of mitral valve disease.

The Effects of Fowler's Position Change on Back Pain and Discomfort of the Patients Following Percutaneous Coronary Intervention (경피적 관상동맥중재술 후 반좌위 체위변경이 환자의 요통과 불편감에 미치는 효과)

  • Nam, So-Young;ChoiKwon, Smi
    • Perspectives in Nursing Science
    • /
    • v.7 no.1
    • /
    • pp.55-64
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the effects of position change from supine to Fowler's on back pain and discomfort in patients who remained on bed rest after undergoing PCIs with a vascular closure device. Methods: Data was collected from 35 inpatients who were hospitalized in coronary-care unit to perform PCIs with a vascular closure device at S hospital in Seoul from December, 2006 to May, 2007. Back pain, discomfort, presence and grade of bleeding and hematoma from femoral arterial puncture site and blood pressure/pulse rate were measured prior to, 10 minutes, 1 hour and 2 hours after position change. Data was analyzed with descriptive statistics, $x^2$ tests and t-tests using SPSS/WIN 12.0 for Windows program. The level of significance (${\alpha}$) was set at 0.05 for this study. Results: We found that there was no significant difference in back pain and discomfort in 10 minutes after position change between the two groups. However, the experimental group reported significantly less back pain and discomfort than the control group in 1 hour (p<.01, respectively) and 2 hour (p<.01, respectively) after position change. There was no significant difference in the presence and grade of bleeding and hematoma at the puncture site, blood pressure, and pulse rate in 10 minutes, 1hour and 2hours after position change between the two groups. Conclusion: Fowler's position change after PCIs in, therefore, safe and effective method of reducing back pain and physical discomfort without causing additional bleeding and changes in blood pressure and pulse rate.

  • PDF

Hybrid Procedure for Muscular Ventricular Septal Defects -2 case reports- (근육형 심실중격결손에 대한 하이브리드 수술법 -2예 보고-)

  • Choi, Seon-Uoo;Yang, Ji-Hyuk;Jun, Tae-Gook;Park, Pyo-Won;Min, Sun-Kyung;Kang, I-Seok
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.747-750
    • /
    • 2008
  • Although surgical closure is the standard approach for a muscular ventricular septal defect, the procedure may be complicated by poor visualization and the need for incision on the ventricle. Another approach is, catheter-based intervention. However, it also has limitations. A hybrid procedure, the intraoperative combined use of an interventional device may reduce the procedure's invasiveness. We successfully managed two cases of muscular ventricular septal defect with a hybrid procedure. We report here on these 2 cases along with a review of the literature.

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

An Immunological Study Before and After Tonsillectomy (편도적출 전 후의 면역학적 연구)

  • 김순웅;윤병용;김순호
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.16.2-16
    • /
    • 1982
  • The palatine tonsils which are located in entrance of digestive and upper respiratory tracts are the most important organ in anatomical and functional structures of the pharyngeal lymphatic tissues. As for function of the tonsil, there have been many suspected theories that were included hematopoietic, hormonal, digestive function and production of vitamin, entry of bacteria with other antigenous materials and defence mechanism of which has taken charge by Virchow in 1860 in past. But among these theories, in recently, defence mechanism of the tonsil was strongly accepted immunologically. For the purpose of elucidating immune response of the tonsil, the author observed serum immunoglobulin levels, peripheral total lymphocyte counts and populations of T, B and Null lymphocytes before and after tonsillectomy in 30 cases of patients with chronic tonsillitis and 29 cases of healthy controls. The results obtained were as follows; 1) Serum Ig M level was significantly higher in patient group than in control group but was not significantly different preoperative from postoperative patient group. 2) Population of T-lymphocyte more significantly decreased in patient group than in control group but it was not significantly different preoperative from postoperative patient group. 3) Population of B-lymphocyte more significiantly increased in patient group than in control group but it was not significantly different preoperative from postoperative patient group. On the basis of these results, it may be suggested that tonsil play partially a role in the immune response of human.

  • PDF