A Study on the Fundamental Performance of a Lego Block System for Road Recovery (도로복구를 위한 레고식 차도블록 시스템의 기초성능에 관한 연구)

  • Lim, Sunwoo
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.191-198
    • /
    • 2017
  • Lego block system forms a temporary pavement area using the assembled structure block in the road excavation work for the maintenance and installation of facilities. This system was developed for a safe passage of vehicles and pedestrians. A study on the fundamental performance of a lego block system was performed through material quality, sliding resistance and compression tests. And compaction performance of ground on the road was reviewed and evaluated through field tests. As a result, a lego block system for road recovery showed the excellent performance and compaction effect.

Evaluation Technique for Digital Substation System based on IEC 61850 (IEC 61850 기반 디지털변전시스템 시험기술 현장 적용)

  • Kim, Namdae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.31-34
    • /
    • 2021
  • 디지털변전소는 IEC 61850 기반 상위운영장치와 IED(Intelligent Electric Device)로 구성된 변전자동화시스템이 적용된 변전소를 의미한다. 한전은 2013 년 이후로 신설되는 154kV 변전소를 디지털변전소로 구축하고 있으며, 기설변전소도 디지털화를 통해 디지털변전소로 변모하고 있다. 이렇게 변전소에 IEC 61850 기반의 변전자동화시스템이 확대 도입됨에 따라 통신 설정과 성능을 검증하는 시험이 반드시 필요하다. 이에 전력연구원은 세계 최고수준의 IEC 61850 기반 디지털변전 시험기술을 확보하였으며, 본 보고서를 통해 연구원이 보유하고 있는 시험기술과 현장에 적용한 사례를 소개하고자 한다.

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

Application of Tuned Mass Damper to Suppress Man-Induced Vibrations of Cable Stayed Foot-bridge (사장교형식 보도교의 보행진동제어를 위한 TMD 적용)

  • Kim, Yun-Seok;Lee, Seung-Woo;Kim, Jae-Min;Chang, Seong-Kyu
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.74-74
    • /
    • 2011
  • 본 연구에서는 중앙경간 54m, 교폭 4m의 사장교형식의 보도교로 측경간은 계단으로 이루어진 1경간 케이블교량을 대상으로 보행하중에 의한 수직진동을 제어하기 위해 제진장치(TMD)를 적용하기로 하고 실물 TMD의 설계 및 제작 그리고 설치 및 제어성능실험을 수행하였다. 우선 사장교형식의 교량. 그리고 1경간 교량이라는 점에서 상대적으로 감쇠율이 낮을 것으로 예측되었고 또한 54m의 경간장이 보행자가 가진 주파수에 근접한 고유진동수를 나타낼 것으로 사료되어 Eurocode 2 part 2(EC5-2)의 규준에 따라 1인 및 다수 보행하중에 의한 보도교의 발생가속도를 산출하였다. 이 경우 최대가속도는 다수의 보행자가 연속적으로 진행할 때 발생하였으며, 수직방향의 가속도가 사용성기준을 초과하는 것으로 나타났다. 또한 구조해석프로그램에 의한 고유치 해석결과, 보행하중의 주파수대역내에 진동모드가 존재하는 것으로 나타났다. 따라서 본 교량의 설계단계에 있어서 보행진동을 제어하기 위하여 유지관리가 용이한 수동형의 동조질량감쇠장치(Tuned Mass Damper)를 적용하기로 하였으며 TMD의 설계에서는 TMD의 제어목표를 만족시킬 수 있는 TMD의 가동질량(moving mass)을 우선적으로 결정하였고, 이로부터 Den Hartog의 제안식에 따라 TMD의 고유진동수비, 유효감쇠비를 산정하였다. 산정된 변수들을 이용하여 설계된 TMD는 현장설치 및 튜닝의 편의성을 고려하여 수평 외팔보형식으로 설계, 제작되었으며 제작된 TMD의 경우 회전축에 대해 질량, 스프링, 댐퍼의 중심거리를 조정함으로써 TMD의 진동수, 강성, 감쇠력을 상대적으로 매우 용이하게 조절할 수 있으며, 조정범위 또한 광범위하여 일반 TMD에 비해 현장설치시 대상구조물에 동조시키기가 용이하며, 작동시 마찰감쇠가 거의 없다는 장점이 있다. 현장설치전에 제작된 TMD를 대상으로 자유진동 시험을 통하여 질량의 중심거리, 스프링 크기 그리고 댐퍼의 설치유무를 각각 변화시키며 TMD의 자유진동 데이터를 취득하였다. 각각의 시험에서 얻어진 데이터로부터 스펙트럼해석을 통하여 고유진동수를 구하였고, 자유진동 파형으로 부터 감쇠비를 구하였다. TMD는 일반적으로 제어모드의 변형형상이 가장 큰 곳에 설치되었을 때 최대의 제진효과를 발휘할 수 있다. 그러나 현장여건상 설치가 불가능하거나 미관을 해치는 경우에는 가능한 범위 내에서 TMD 제어효율이 가장 크게 발휘할 수 있는 곳을 선택하여야 한다. 본 보도교의 경우, 중앙경간 중심부에서 가장 큰 모드변형형상을 나타내지만, 보도교의 상판 연결부 등에 따른 TMD 시공문제로 인하여 TMD 설치위치는 교량 중앙에서 양 방향으로 1.25m 떨어진 곳에 대칭으로 총 2기를 설치하기로 하였다. 일반적으로 TMD의 모든 설계변수는 구조물의 설계단계에서 수행된 구조해석결과에 근거하여 설정하므로 완공된 구조물, 즉 실제보도교의 동적특성을 계측하여 정확하게 진동수를 튜닝하여야 한다. 구조해석에 의한 보도교의 수직방향(TMD 작동방향) 고유진동수는 1.5225 Hz이며, 감쇠비는 규준에 의하여 0.6 %로 가정하였다. 그러나 이 값들은 구조해석모델 및 재료적 특성과 시공상의 오차에 의하여 실제와 다를 수 있으므로 현장계측에 의한 확인이 요구된다. 또한 TMD의 제진효율이 설계시의 목표대로 확보되었는지도 확인해야 하므로 현장튜닝 및 성능시험을 실시하였다. 보도교의 가진은 사전에 실시한 상시 미진동계측결과를 토대로 2Hz를 목표로 하여 인력가진실험을 수행하였고, 탁월진동 주파수는 1.9896Hz로 나타나 구조해석결과와 오차가 있음을 알 수 있다. 가진실험결과를 토대로 TMD의 진동수를 최적진동수비로 튜닝하고 인력가진 실험을 다시 실시하여 TMD의 진동제어성능을 검토하였다. TMD 튜닝 전, 후의 보도교 감쇠비를 비교한 결과, TMD를 설치함으로써 약 4.218%의 감쇠비 증가가 있음을 알 수 있다.

  • PDF

Coparative study on the dynamic properties of fuel oils (연료유(가솔린, 디이젤 연료, 천연가스)의 성능평가 방법 비교 연구)

  • 최주환
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.1-22
    • /
    • 1996
  • 연료유(가솔린, 디이젤 연료, 천연가스)의 성능평가 방법으로서 기존 ASTM 표준엔진 시험방법에 많은 단점들이 지적되어 그동안 이를 대체할 수 있는 방법에 관하여 많은 연구가 진행되어 왔다. 본 고에서는 그동안 연구되어온 이들 사항들을 요약 정리하여 서로를 비교코저 하였다. 새로운 여러가지 평가방법들은 석유정제공정의 품질관리, 자동차 생산현장에서의 엔진시험, 연구, 자동차 배기가스 영향 등의 대기환경 연구 등에 필수적으로 사용될 수 있을 것으로 생각되며 해외에서는 최근 이들 방법들의 상업화된 기기의 개발과 시판 사용이 1990년대 접어들면서 급격히 증가하고 있는 실정이다. 이들 방법들은 기존의 ASTM 표준엔진 시험 방법의 여러 가지 난점을 극복키 위해 보다 신속, 정확하고 적은 시료의 양, 측정 가동의 편이성, 저렴한 운용 관리비, 많은 시료의 연속적인 측정 용이, 기존 시험엔진에 비해 저렴한 측정기기 가격 등 많은 장점을 보유하고 있다. 특히 자동차 관련 연구소의 엔진시험분야에서 배기가스에 미치는 연료 조성 및 물성의 영향과 동력학적 성질의 예측 등은 매우 중요하리라 생각된다. 그러므로 관련분야의 품질관리, 연구개발을 위해 본고의 내용이 도움이 되었으면 한다.

  • PDF

A Pilot Study of In-hole Seismic Method (인홀탄성파시험의 타당성 연구)

  • Mok, Young-Jin;Kim, Jung-Han;Kang, Byung-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.3
    • /
    • pp.23-31
    • /
    • 2003
  • Over the past half century, borehole seismic surveys have been diversified into the three techniques such as crosshole, downhole, and suspension logging according to their devices and testing configurations. These field techniques have been improved, in terms of equipment and testing procedures, and are very valuable in the evaluation of ground characteristics for geotechnical and earthquake engineering problems. Yet, despite the importance and significance of the techniques as engineering tools, the techniques are not much used as standard penetration test (SPT) by practicing engineers. The possible explanations are cost and operational difficulties of the surveys as well as sophistication and complexity of the devices. An in-hole seismic method has been developed to meet the requirement of economical testing cost and practicality in engineering practice to measure dynamic soil properties. The prototype in-hole probe developed herein is small and light enough to be fit in three-inch boreholes and to be handled with bare hands. The performance of the source has been evaluated through extensive crosshole tests at various sites. The in-hole seismic method was adopted at three test sites and verified by comparing with crosshole results.

Test Technology for Wind Turbines and Their Components (풍력터빈과 부품의 시험기술)

  • Hwang, Byeong-Seon;Lee, Hui-Won;Lee, Geun-Ho;Jo, Han-Uk
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.38 no.7
    • /
    • pp.29-38
    • /
    • 2009
  • 지난 20년간 급속한 발전을 통하여 회전 블레이드의 직경이 126 m, 나셀까지의 높이가 약 130 m에 이르는 6,000 kW의 용량을 가지는 풍력발전기가 개발되었다. 세계적으로 풍력발전의 필요성과 중요성이 인식되어 2008년 현재 약 120,000 MW의 설치 용량을 기록하고 있다. 풍력터빈(wind turbine)과 그 부품의 기계적인 성능평가의 종류와 방법은 많은 사람들의 관심인 것으로 판단한다. 우선 풍력터빈을 구성하는 주요 핵심부품은 블레이드, 증속장치, 발전기 등이며, 세부 구성 부품으로 허브, 핏치와 요베어링, 주축베어링, 타워 등이 있다. 주요핵심 부품인 블레이드, 증속기, 발전기 등의 성능평가가 중요한 이슈이다. 또한 모든 구성품을 조립하여 초기의 설계사양에 따라서 제조되고 최종성능이 발휘되는지 여부를 현장시험을 통하여 성능평가과정을 거치게 되는데 이 과정은 풍력터빈의 성능평가라고 하며 주요 평가대상은 출력성능(power performance), 소음(noise), 하중(load), 전력품질(power quality) 등 4가지 항목을 집중적으로 측정하여 개발된 풍력터빈의 전반적인 성능을 평가하게 된다. 본 투고에서는 핵심부품인 블레이드, 증속기, 발전기에 대한 시험기술과 풍력터빈의 성능평가 항목인 4개 측정 항목에 대하여 기술하였다.

  • PDF

A Study on the Development of Standardization Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector (차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구)

  • Kim, Shi-Kuk;Yuk, Hyun-Dai;Yang, Seung-Hyun;Jee, Seung-Wook;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.85-92
    • /
    • 2009
  • This paper studied on the development of standardization tester for the field inspection of the rate of rise spot type heat detector. It was to find the problems of the 4 type's testers such as A type (electric bulb type), B type (halogen lamp type), C type (heating coil type), D type (fumigator type) which were used to check of the rate of rise spot type heat detector in inspection for the fire protection. To identify those problems, this paper described about the development of standardization tester for the field inspection of the rate of rise spot type heat detector and that have the function of auto setting temperature more $30^{\circ}C$ higher than room temperature and keep the constant temperature. And keep the constant wind velocity of 85cm/sec. Performance verification results of the developed prototype that had same conditions such as the sensitivity test conditions at the type approval of the rate of rise spot type heat detector.

A Study on Test Method for Performance Evaluation of Rockfall Protection Fence (Post) (낙석방지울타리(지주) 성능평가를 위한 시험방법 연구)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.2
    • /
    • pp.5-12
    • /
    • 2022
  • In this study, a field test was conducted to present a test method for performance evaluation of a rock fall prevention fence, centering on the vertical drop test among the existing test methods of the rock fall prevention fence. A test to determine the support capacity of a rockfall prevention fence in Korea is usually conducted using a combination of wire mesh, poles, and wire rope, and the location of the impact of falling rocks has been conducted centered on the center of the wire mesh. However, in the case of domestic papers and test data, there is no data on direct hit of post. Therefore, the amount of displacement and weak section were analyzed when the impact on 100kJ class rock energy was hit on the post, centering on the Rockfall Protection fence (highway type No. 2).

Study on Water Cycle Performance Evaluation Experiment of Permeable Block (투수블럭의 물순환 성능평가 실험에 관한 연구)

  • Jang, Young Su;Park, Jong Bin;Lee, Jae Hyuk;Kim, Jae Moon;Jung, Min Ho;Shin, Hyun Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.331-331
    • /
    • 2020
  • 급격한 산업화와 도시화로 인한 도시유역의 불투수면의 증가와 이에 따른 배수능력의 저하로 인해 도시 물순환의 왜곡이 발생하였다. 따라서 과거 도시 물관리 기법의 한계가 나타났으며 이를 위해 저영향개발 기법 등과 같은 도시 물관리 기법의 패러다임이 변화하였다. 본 연구에서는 저영향개발 기법에서 도시유역 내 활용이 유용한 침투형 시설 중 투수블럭에 대한 물순환 성능평가를 실외실험을 통해 분석하였다. 성능평가 실험은 부산대학교 양산캠퍼스 한국 GI&LID 센터 내 투수블록 뿐만 아니라 블록 하부 골재층까지 설치가 가능하도록 되어있어 실제 현장과 유사한 환경을 구축이 가능한 2.4×10.9×0.4 (m) 규모의 주차장형 LID 실증시험시설을 활용하였다. 인공강우 분사를 위한 실외 인공강우모사 장치 크기는 2×2(m)으로 본 시험을 위하여 5개의 인공강우모사 장치를 연결하여 활용하였으며, 본 시험장치는 강우를 공급하기 위한 수조와 펌프, 일정한 유량을 유입하기 위한 유량계, 강우를 분사하기 위한 노즐, 인공강우가 실제 강우와 같이 자유낙하 하도록 구현하기 위한 오실레이터 등으로 구성되었다. 시험대상인 틈새투수블록은 석재블록 규격 400×600×100 mm이며 재질은 받침안정층(흙), 투수블록(화강석)으로 구성되어 있다. 실험의 시나리오는 시험체에 강우강도 30mm/hr, 50mm/hr, 100mm/hr에 해당하는 양을 1시간 동안 유입하여 시험 시작 후, 강우지속시간, 표면유출지속시간, 표면유출량을 1분 단위로 측정. 시험체에 유공관이 설치된 경우에는 침투유출지속시간, 침투유출량도 함께 1분 단위로 측정하였으며 각 강우강도별로 측정하고, 1회 측정 후, 각 시험별 시험 대상체의 조건을 같게 하기 위한(하부 지반의 건조) 약 3일 이후(상황에 따라 변동 가능) 시험하였다. 본 실험의 결과, 강우강도가 30 mm/hr와 50 mm/hr인 경우에는 화강석 틈새투수블록포장에서 지표 유출이 발생하지 않았으며, 강우강도 100 mm/hr의 경우 260 L의 지표 유출이 발생하여, 불투수표면 대비 84%의 지표유출 저감률을 보여줌으로서 투수블럭에 물순환 성능에 대한 효과를 분석하였다.

  • PDF