• Title/Summary/Keyword: 현장 성능시험

Search Result 639, Processing Time 0.031 seconds

Study on Work-Efficiency in feild of PFB(POSCO E&C Fire Board) for High Sterength Concrete Spalling Control (고강도 콘크리트 폭렬제어를 위한 PFB(POSCO E&C Fire Board) 공법의 현장 시공성에 관한 연구)

  • Kim, Woo-Jae;Park, Dong-Cheol;Yang, Wan-Hee;Lee, Sea-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.961-964
    • /
    • 2008
  • There are researches in progress on ensuring the safety of the high impact concrete in case of fire which is a current rising social problem and this research institute also developed PFB technology, the explosion preventing technology. PFB technology is to apply POSCO E&C Fire Board, a fireproof board, with an adhesive agent on the construction site, and this technology passed 3-hour fireproof test and this technology was proven from a previous research that the temperature of main root is maintained under $200^{\circ}C$. Therefore, tests on basic contents was performed in this research before the actual construction, with a full scale of wooden prototype to apply PFB technology to actual construction sites and the tests were done on the workability of fireproof board, the adhesive power, the resistance against imprint of wooden nail, the heat conductivity and etc. As the results of these tests, PFB technology was proven to have an excellent workability at a construction site and to be easy for processing and also, this technology was proven to have a great resisting power against imprint of wooden nail. Therefore, this research has confirmed that PFB technology has no problem to be applied on a construction site.

  • PDF

맥동관형 크라이오 펌프 국산 시제품 성능예측과 평가

  • In, Sang-Ryeol;Tak, Yeong-Jun;Gang, Sang-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.94-94
    • /
    • 2012
  • 맥동관형 크라이오펌프 개발 2단계를 맞아 우성진공(유)을 중심으로 상용화 시제품 제작이 진행되고 있다. 최종 크라이오 펌프 개발품은 흡기구 직경(내경) 16.5 (14) 인치에 질소 배기속도 3,600 L/s를 목표로 하고 있다. 상용품 완성 전에 거쳐야 할 필수적인 시험과정으로 시제품의 공정대응성 현장평가를 위해 KAIST 나노팹에 개발품을 투입하는 프로그램이 계획되어 있어서 공정장치에 장착할 수 있도록 10인치 크라이오 펌프 제작이 추가로 진행되고 있다. 개발품의 성능확인은 우선 몬테카를로 계산을 통해 배기속도를 예측하고 구조설계를 최적화했으며 이를 바탕으로 가공 조립된 크라이오펌프 시제품의 성능을 표준화된 장치에서 표준화된 절차를 통해 평가하여 설계 목표값과 비교했다. 한편 개발품의 성능 수준을 상대적으로 규정하기 위해 기존 상용품들을 같은 방식을 따라 평가하여 성능을 서로 비교하는 작업을 수행했다. 10인치 모델로는 국산 Genesis HPM200, CTI-8 수직형 및 수평형 GM 크라이오 펌프를 성능 시험했으며 16.5인치 개발품의 유사모델로 CTI-12 GM 크라이오 펌프를 시험해서 비교했다.

  • PDF

Performance Test of Optical Fiber Sensors Using Embankment Pool Model (토조모형을 이용한 광섬유 센서 성능 시험)

  • Park, Kyoung-Won;Hwang, Eui-Ho;Lee, Gwang-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.649-653
    • /
    • 2012
  • 제방붕괴에 따른 피해발생을 억제하기 위해서는 제방거동 특성을 사전에 충분한 정보를 통하여 파악할 필요가 있으며, 이를 위해 광섬유를 이용한 제방누수감지 센서를 개발하였다. 광섬유는 내구성 및 유지관리가 우수하고 장기간 사용에도 장점을 가지고 있다. 개발된 센서들은 현장에 적용하기 전에 충분한 실험을 통해 성능과 기능에 대한 검토가 필요하다. 본 연구에서는 개발된 광섬유 센서를 대상으로 제방누수감지 목적으로 설치할 경우 센서의 이행도를 시험하였다. 시험방법은 토조를 설치하여 제체에 작용하는 간극수압, 온도 및 변위 등을 대상으로 하였다. 이를 위해 폭 5m, 길이 7m 및 높이 2m의 토조를 설치하여 가제방의 주요 부위에 기존 계측기기와 광섬유 센서를 같이 매설하고 수위와 시간변화에 따른 주요 특성치에 대하여 실험하였다. 실험결과 광섬유 센서가 연구목적에 부합하는 계측치를 보여주어 제방누수감지 센서로 활용 가능함을 확인하였다. 아울러 광섬유 센서의 기능에 대한 전반적인 실험을 통하여 현장적용에 대한 사용성을 입증하였다.

  • PDF

An Empirical Study on the Standard Re-establishment of Water Discharge Performance for the Fire Engine Pump (소방차 펌프의 방수성능 기준 재정립을 위한 실증적 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.85-91
    • /
    • 2012
  • This paper analyzed firefighting officers' use situations such as the use time, maximum working pressure, hose diameter, etc. of fire pumps at fire sites and carried out various performance tests by pressures, hose diameters and quantities of fire pumps based on its results because the waterproof performance criterion for a fire pump installed in a fire engine is different from the operation situations at the site and is not clearly prescribed. As a result of site survey, the site uses a higher pressure than the standard water discharge pressure (0.85 MPa) or the high-pressure water discharge pressure (1.4 MPa) prescribed by the approval Standard of the fire pump performance on fire truck. In addition, as a result of pump performance test, the discharged water flow rate, water discharge pressure, etc. was measured to be very different from the currently prescribed the approval standard depending on the hose diameter and firefighting nozzle, so the result of this study proposes a new standard.

Study on the Test Method of Impact Sound Pressure Level Using the Miniature Mortar (축소모형 시험판을 이용한 바닥충격음 측정방법에 관한 연구)

  • Park, Cheol-Yong;Hong, Gu-Pyo;Lee, Sang-Jun;Kim, Jin-Kyu;Kim, Kyu-Rae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1446-1449
    • /
    • 2007
  • 인정바닥구조는 신청에서부터 인정서 발급까지 기본적으로 2개월 이상이 소요되며, 신청 제품이 많을수록 그 기간은 길어지게 된다. 본 논문은 이와 같은 완충재의 성능을 확인하기 위해 소요되는 기간과 비용을 획기적으로 단축할 수 있는 간편한 방법을 제시하기 위한 것이다. 완충재 설치 이후 습식으로 시공되는 경량기포콘크리트와 모르터를 사전에 일정 크기로 제작(축소모형 시험판)한 후 골조가 완성된 현장에서 바닥충격음을 측정하는 방법이다. 완충재 2개 제품에 대하여 축소모형 시험판을 이용하여 측정한 결과와 전체 세대를 시공한 후 측정한 결과를 비교한 결과 경량충격음은 축소모형 시험판이 훨씬 낮은 결과를 나타냈지만 중량충격음은 비슷한 결과를 나타냈다. 이로써 축소모형 시험판을 이용하여 바닥충격음을 측정하는 것은 경량충격음을 저감하기 위한 재료 선정 및 제품 시스템 구성 등에 활용될 수 있을 것이며, 현장에서 중량충격음 차단성능을 신속하게 검증할 수 있는 방법으로 활용할 수 있을 것으로 기대된다.

  • PDF

Evaluation of Color Coating Method for Color Maintenance of Color Asphalt Pavement (칼라 아스팔트 포장의 색채 표면보수를 위한 칼라코팅 공법 성능평가)

  • Park, Tae-Soon
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.93-101
    • /
    • 2011
  • The evaluation of various color coating methods for color maintenance of color asphalt pavement is conducted using the laboratory and field tests on the bus lane. The surface of color asphalt constructed on the bus lane is deteriorated such as changing color and decoloration and abrasion due to the passing of the traffic and time. The total of 9 coating methods were evaluated in this study. The laboratory tests included Ultra violet test, adhesion test and Taber abrasion test and the field tests were british pendulum test and visual survey. The results of tests showed that the different methods showed the their own engineering characteristics and it is dependant upon the main material used. The rubber epoxy material for the main material showed the satisfactory result among the methods tested. However, the performance of the coating methods after 100days are not satisfactory, decoloration, abrasion and peeling up are investigated and need to be studied for the further application in the field.

A Study on Performance of Steel Monocell Expansion Joints (강재형 모노셀 신축이음장치 성능 연구)

  • Kim, Yong-Hoon;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.502-509
    • /
    • 2019
  • Studies have been made on performance evaluation of expansion joint systems for an ordinary highway or road bridge. However little study has been made for runway connection bridges at airports. A study on performance evaluated from computer code analysis and shrinkage, extension, and compression repetition tests based on KS F 4425 is conducted to a newly developed expansion joint system which has been installed in a runway connection bridge at Incheon Airport Extension 2 Construction Site. The MIDAS computer code is used to analyze the performance before the manufacture of the mock-up of expansion joint system on the basis of design requirements. Tests based on the KS F 4425 of 2001 year-version are conducted for the mock-up. Domestic codes and standards to validate the performance of the expansion joint system in a connection bridge have been developed for a vehicle. However the expansion joint system tested in this study is installed in a runway connection bridge for an aircraft. Conservatively the heaviest one among airplanes departing and landing at Incheon Airport is assumed level-F $468.4kN/m^2$ and adopted for the tests and analyses in this study. KS F 4425 method is selected for the shrinkage, extension, and compression repetition tests. No remarkable problem was observed for the 2,500-cycle shrinkage and extension and two million-cycle repeatition load tests. The results of this study are expected to contribute to establishment of code and standard for the performance validation of an expansion joint system installed in a runway connection bridge for an aircraft by providing performance test results and computer analysis results based on finite element methods.

Steady-state Modelling of Centrigugal Chiller through On-Site Test (현장성능시험에 의한 터보냉동기의 정상상태모델 개발)

  • Chang, Young-Soo;Shin, Young-Gy;Baik, Young-Jin;Kim, Young-Il
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.83-88
    • /
    • 2001
  • This paper presents modelling and analyzing method of centrifugal chiller which has a rated capacity of 200 RT(703 kW) through on-site performance test. Field data of chiller installed in the clean-room building of KIST have been collected, Simple models were developed for predicting the heat exchangers and system performances by regression of chiller operation data during 5 days in August. The models proposed here account for the effect of variations of cooling capacity, temperatures and flow rates of secondary fluids. The models are consistent with real performance data from June to September within ${\pm}5%$ error. The COP of centrifugal chiller are estimated under the standard rating conditions and reduced mass flow rate of chilled and cooling water.

  • PDF

감마선검출법에 의한 사용후CANDU핵연료 수중검증장치 개발

  • 이영길;나원우
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.350-355
    • /
    • 1997
  • 가압중수로(PHWR)형 원자력발전소의 저장수조에 보관중인 사용후핵연료를 대상으로 하는 핵물질 보장조치(safeguards) 이행에 필요한 핵연료다발 수중검증장치를 개발하였다. 본 장치는 CdTe 감마선검출기, 차폐체 및 시준기등으로 구성된 검출부와 이를 지지 및 구동하기 위한 구동부로 구성되어 있다. 검출부에 대하여 감마선 표준선원 및 사용후핵연료 시료를 사용하여 성능시험을 수행한 결과 현장검증시의 요건을 만족하였고, 구동부의 경우 건식조(dry pit)에서 수행한 예비실험 결과 검증목적에 적합하였다. 따라서, PHWR형 원자력발전소인 월성 1 호기의 수중저장조에 있는 사용후CANDU핵연료에 대한 현장성능시험을 현재 준비중에 있으며 그 결과를 바탕으로 하여 국가사찰시에 본 장치를 사용할 예정이며, 향후 IAEA의 공인을 획득하여 IAEA 사찰용 장비로도 활용할 계획이다.

  • PDF

The Performance Analysis and On-site Performance Test of a Dedicated Outdoor Air System (외기 전용 공조기의 성능 분석 및 현장 성능시험)

  • Kim, Young-Il;Kim, Jung-Min;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.346-351
    • /
    • 2007
  • Dedicated outdoor air(DOA) system which conditions the outdoor air separately is superior to conventional cooling+reheating system with respect to energy consumption and indoor comfort. Since the sensible and latent load characteristics of indoor and outdoor are different, it is more efficient to treat them separately. In this study, cycle analysis and on-site performance test of DOA system have been conducted. The study shows that DOA requires 48.8% less equivalent energy that conventional system. The on-site performance test of the prototype shows that the coefficient of performance(COP) of the DOA system is 37.4% higher than the conventional system.

  • PDF