• Title/Summary/Keyword: 현장적용 성능평가

Search Result 551, Processing Time 0.026 seconds

Study on Performance of pH Reducing Agent Applied for Wet Process of Recycled Aggregate (습식 순환골재의 생산공정에 적용 가능한 pH 저감제의 성능 검토)

  • Choi, Jung-Gu;Lee, Gun-Cheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.4
    • /
    • pp.366-373
    • /
    • 2015
  • Construction waste is recycled and used for the efficient and eco-friendly disposal of construction waste increasing due to reconstruction and redevelopment project and so on. There is recycled aggregate as a typical case. And this recycled aggregate shows strong alkalinity due to calcium hydroxide, and causes many environmental problems. Therefore, this is a study on reduction in the strong alkalinity of recycled aggregate by using sodium phosphate based ammonium in order to reduce the pH of recycled aggregate. Besides, a possibility that a pH reducing agent of recycled aggregate could be applied to a site was evaluated. As a result, it was possible to verify that pH decreased as the percentage of pH reducing agent increased. It is thought that the pH reducing agent can be applied to a site by methods such as immersion and spray using the pH reducing agent in the process of producing recycled aggregates.

An Experimental Study on Structural Characteristics of 50m span Portable Prestressing Bed (50m급 이동식 긴장대의 구조특성에 관한 실험연구)

  • Kim, Jong-Suk;Yoon, Ki-Yong;Kim, Yong-Hyeog
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.280-283
    • /
    • 2011
  • 본 연구는 50m급 프리텐션 방식의 PSC 거더를 제작할 수 있는 이동식 긴장대의 실험결과를 분석하여 이동식 긴장대의 구조 성능을 평가한 것이다. 현재 사용되는 프리텐션 방식의 PSC 거더는 공장에서 제작, 운반하여 현장에서 가설하는 방식이나 도로주행 여건에 의해 운반 가능한 부재의 크기가 제한됨에 따라 운반이 가능한 소규모 부재에만 프리텐션 방식이 적용되고 있다. 이에 본 연구에서는 현장에서 프리텐션 방식으로 PSC 거더를 제작할 수 있는 이동식 긴장대를 개발하고자 한다. 본 논문에서는 50m급 PSC 거더를 생산할 수 있는 이동식 긴장대를 제작, 실험하여 실험결과를 통하여 각 구성 요소가 이동식 긴장대에 작용하는 긴장력에 저항하는 메카니즘을 파악하여 개발하고자 하는 이동식 긴장대의 구조적 특성을 파악하고자 하였다.

  • PDF

Field Application of 80MPa High Strength Fire Resistant Concrete using Ternary Blended Cement (설계강도 80MPa 3성분계 고강도내화콘크리트의 현장적용 및 성과분석)

  • Kim, Seong-Deok;Kim, Sang-Yun;Bae, Ki-Sun;Park, Su-Hee;Lee, Bum-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.113-119
    • /
    • 2010
  • Fire resistance and field tests for high-strength concrete(HSC) of 80MPa were carried out to evaluate whether or not it shows the same material properties even in the field condition of being mass-produced and supplied. As a result, it was found that fire resistant HSCs containing composite fiber(NY, PP) of 0.075% have great resistance to fire and spalling. In the field test, before the pumping air contents, slump flow, U-box, L-flow, compressive strength, gap of hydration temperature of interior and exterior of specimen and placing ratio per hour satisfied the required properties of HSC. However, after the pumping of HSC, as slump flow and L-flow were slightly less than required criterion, they need to be improved. In terms of hydration temperature of HSC, it was found to satisfy the related criterion. Packing ability as well as placing ratio per hour of HSC, which was about $44m^3$, show outstanding results. If slump flow of developed ternary HSC is improved after the pumping it can be useful for the construction of high-rise buildings.

Structural Health Monitoring System Employing Smart Sensor Technology Part 1: Development and Performance Test of Smart Sensor (스마트 센서 기술을 이용한 구조물 건전도 모니터링 시스템 Part I : 스마트 센서의 개발과 성능평가)

  • Heo, Gwang Hee;Lee, Woo Sang;Kim, Man Goo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • In this study, a smart sensor unit is developed by using the smart sensor technology that is being rapidly developed in recent years for structural health monitoring system, and its performance is evaluated through various experiments, and also, damage detection experiment is performed on a model structure. This paper as the first half of this study contains the development and performance evaluation of the smart sensor. In the latter half of this study, structure damage detection experiment is performed for the application of verified smart sensor unit into structural health monitoring, and it is compared with a wire measurement system. The smart sensor is developed by using high-power wireless modem, MEMS Sensor and AVR microcontroller, and an embedded program is also developed for the control and operation of the sensor unit. To verify the performance of the smart sensor, many experiments are performed for sensitivity and resolution analysis tests, data acquisition by using cantilever beam and shaker, and on-site application using actual bridge. As a result, the smart sensor proves to be satisfactory in its performance.

Evaluation of Mechanical Properties of Molding Materials Recycled Using Film Packaging Wastes (폐필름 포장재 재활용 성형재료의 역학적 특성 평가)

  • Kwon, Seung-Jun;Lim, Hee-Seob;Yang, Keun-Hyeok;Yoon, Hyun-Sub
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.342-348
    • /
    • 2018
  • The present study examined the various strength and deformation performances of molding materials recycled using film packaging wastes to ascertain the their applicability to secondary products in construction industries. The stress-strain relationships of molding materials were measured under compression, tension, and flexure in accordance with the ASTM procedure. The measured mechanical properties of recycled molding materials were comparable to typical ranges observed in low-density polyethylene and/or high-density polyethylene. However, to stabilize the properties of the molding materials, further management systems are required as follows: 1) evaluation of mechanical properties of materials with respect to various mixing proportions of waste ingredients; 2) estimation of the effect of foreign substance and moisture contents on the mechanical properties; and 3) establishment of comprehensive database including various sources such as manufacture process including applied pressure to produce the molding materials, and collection region and time of wastes.

An Onsite Test by Full-Test Procedures of ISO GNSS RTK Standard (GNSS RTK 표준규격의 엄밀시험절차에 따른 현장시험)

  • Lee, Young-Jin;Jo, Jun-Rae;Song, Jun-Ho;Jung, Rae-Jung
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2009.04a
    • /
    • pp.293-294
    • /
    • 2009
  • 정밀한 관측을 요하는 측량장비의 기능을 보정하거나 검증하는 것은 측량시 매우 중요한 일이다. ISO17123-8 규격은 GNSS RTK 정확도를 결정 할 때 사용되는 야외실험 절차와 규정을 명시하고 있으며 정확도 평가방법으로는 약식시험절차와 엄밀시험절차를 제시하고 있다. 본 연구에서는 GNSS RTK 정확도 평가방법 중 엄밀시험절차에 대해 시험할 목적으로 GNSS RTK 규격에 따라 Test-bed를 구축하였고 성능실험을 실시 위하여 GNSS RTK 규격에 제시된 정확도 평가방법을 적용하였다.

  • PDF

Correlation between Channel-Flow Test Results and Rheological Properties of Freshly Mixed Mortar (굳지 않은 모르타르의 채널 플로와 레올로지 특성의 상관관계)

  • Shin, Tae Yong;Lee, Jin Hyun;Kim, Jae Hong;Kim, Myeong Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.237-244
    • /
    • 2016
  • The workability of mortar determines its construction performance in a structure showing its designed resistance to external loads. Measuring the rheological properties of mortar is one way of quantifying its workability, but its field-applications are limited due to economical and spatial issues. The robustness of the slump flow test allows its use for evaluating the workability of mortar, even though it is a rather qualitative test method. This paper proposes a channel flow test and develops a correlation between its result and the rheological properties of mortar. The volume-of-fluid simulation for the channel flow test was accomplished, and a numerical database for the correlation was composed. A correlation model to estimate the rheological properties of mortar using the results of the channel flow test as inputs is proposed.

Evaluation on real-time multi-point sensing performance of IoT-based hybrid measurement system (IoT 기반 하이브리드 계측시스템 실시간 다점 측정 성능 평가)

  • Kim, Heonyoung;Kang, Donghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.543-550
    • /
    • 2018
  • The rapid growth of IoT technology induced by the fourth industrial revolution has resulted in research into various types of wireless sensors, and applications based on this technology are prevalent in many areas. However, among the various sites where this technology is used, railway bridges and tunnels with lengths of tens of kilometers have problems with data acquisition, due to the signal noise induced by the long distance measurement and EMI induced by the high voltage power feeding system, when conventional electric sensors are used. To overcome these problems, many studies on fiber optic sensors have been conducted as a substitute for the conventional electric sensors. However, restrictions on the types of fiber optic sensors have limited their application in railways. For this reason, a hybrid measurement system with IoT based wireless data communication, in which both electric and fiber optic sensors can be applied simultaneously, has been developed. In this study, in order to evaluate the applicability of the hybrid measurement system developed in the previous study, a real-time test for 4 types of measurement environments, which reflect possible railway sites, is performed. As a result, it was confirmed that the signals from both the electric and fiber optic sensors, which were acquired at a remote area in real-time, showed good agreement with each other and that this measurement system has the potential to handle sensors with a sampling rate of 2.5 kHz. In the future, it is expected that the IoT-based hybrid measurement system will contribute to the improvement of structural safety by enabling real-time structural health monitoring when applied to various measurement sites.

Applicability Evaluation of Eco-Friendly Binder Material using Desulfurized Dust in Deep Cement Mixing Method (탈황분진을 활용한 친환경 안정재의 심층혼합공법 적용성 평가)

  • Ko, Hyoung-Woo;Seo, Se-Gwan;An, Yang-Jin;Kim, You-Seong;Cho, Dae-Sung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.2
    • /
    • pp.1-12
    • /
    • 2016
  • In this study, laboratory mixture design test and field test were performed to evaluate applicability of eco-friendly binder material (CMD-SOIL) using desulfurized dust in deep cement mixing method (DCM). As a result of laboratory mixture design test, the uniaxial compressive strength of CMD-SOIL was up to 1.136 times bigger than slag cement by changing the water content, mixing rate, and W/B. Also, it had shown the strength up to 1.222 times bigger in shell content and up to 1.363 times in mixing of floating soil. As a result of field test, field strength/laboratory design criterion strength ratio (${\lambda}$) is shown 0.77. And this result was similar to earlier studies. From this result, CMD-SOIL can show the same efficiency compared with existing binder.

Evaluation of Ground Thermal Conductivity by Performing In-Situ Thermal Response test (TRT) and CFD Back-Analysis (현장 열응답 시험(TRT)과 CFD 역해석을 통한 지반의 열전도도 평가)

  • Park, Moonseo;Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.5-15
    • /
    • 2012
  • In this study, a series of CFD (Computational Fluid Dynamics) numerical analyses were performed in order to evaluate the thermal performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju. The circulation HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The simulation results provide a verification for the in-situ thermal response test (TRT) data. The CFD numerical back-analysis with the ground thermal conductivity of 4 W/mK yielded better agreement with the in-situ thermal response tests than with the ground thermal conductivity of 3 W/mK.