• Title/Summary/Keyword: 허용성

Search Result 2,955, Processing Time 0.034 seconds

Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1) (유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1))

  • Park, Jung-Wook;Park, Eui-Seob;Kim, Taehyun;Lee, Changsoo;Lee, Jaewon
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.400-425
    • /
    • 2018
  • This study presents the research results and current status of the DECOVALEX-2019 project Task B. Task B named 'Fault slip modelling' is aiming at developing a numerical method to simulate the coupled hydro-mechanical behavior of fault, including slip or reactivation, induced by water injection. The first research step of Task B is a benchmark simulation which is designed for the modelling teams to familiarize themselves with the problem and to set up their own codes to reproduce the hydro-mechanical coupling between the fault hydraulic transmissivity and the mechanically-induced displacement. We reproduced the coupled hydro-mechanical process of fault slip using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. A methodology to formulate the hydro-mechanical coupling relations of two different hydraulic aperture models and link the solid element of TOUGH2 and the interface element of FLAC3D was suggested. In addition, we developed a coupling module to update the changes in geometric features (mesh) and hydrological properties of fault caused by water injection at every calculation step for TOUGH-FLAC simulator. Then, the transient responses of the fault, including elastic deformation, reactivation, progressive evolutions of pathway, pressure distribution and water injection rate, to stepwise pressurization were examined during the simulations. The results of the simulations suggest that the developed model can provide a reasonable prediction of the hydro-mechanical behavior related to fault reactivation. The numerical model will be enhanced by continuing collaboration and interaction with other research teams of DECOLVAEX-2019 Task B and validated using the field data from fault activation experiments in a further study.

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

Effects of Initial Defoliation Stage and Defoliation Interval on the Growth of White Clover Cultivars Differing in Leaf Size (최초예취시간 및 예취간격이 엽의 크기가 다른 White Clover 품종들의 생장에 미치는 영향)

  • 강진호
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.3
    • /
    • pp.264-273
    • /
    • 1992
  • Availability of white clover (Trifolium repens L.) has been limited due to its poor introduction to swards and lack of persistence under improper grazing management. This experiment was conducted to determine the effects of initial defoliation stage and defoliation interval on the growth of white clover varieties. Individual plants of Regal (large leaf), Louisiana S.1 (medium-large leaf), Grasslands Huia (medium-small leaf) and S184 (small leaf) were grown in containers (4.5 $\times$ 13.5 cm) containing a 1:2:1 soil:sand:Promix until reaching to the stage of 1, 4, or 8 trifoliolates, and then clipped to remove all fully expanded leaves every 7 or 28 days (d). For analysis of morphological parameters, plants were sampled on the final harvest date (0 d), and 7, 14, 21, and 28 d after the final harvest date. Harvested dry weight (dw) of all varieties declined as defoliation interval declined or initial defoliation was made earlier. That of Regal was the highest as initial defoliation was delayed. On the 7 d regrowth shoot and root dw were increased as initial defoliation was delayed or interval lengthened, whereas on the 28 d regrowth the trend was alleviated. Root dw and biomass of Regal were higher than the other varieties during the whole regrowing period, when the increase of biomass resulted from that of shoot dw. Leaf areas and petiole lengths of all varieties declined under 7 d defoliation interval. The area and the length declined with earlier initial defoliation on the 7 d regrowth but not on the 28 d regrowth. Stolon length and growing tips of S184 were the highest and increased more steeply during regrowth, while those of Regal were the lowest and did slightly. It is concluded that the continuous defoliation and the first defoliation at earlier growth stage have detrimental effects on growth of white clover, although larger leaf types are more productive but less persistent in a sward than smaller leaf types.

  • PDF

Assessment of 1,4-Dioxane Removal in Polyester Wastewater by Activated Sludge and Its Microbial Property by 16S rDNA (폴리에스테르 중합폐수의 활성슬러지 공정에서의 1,4-다이옥산 제거 및 16S rDNA에 의한 미생물 군집특성 평가)

  • Han, Ji-Sun;So, Myung-Ho;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.393-400
    • /
    • 2008
  • 1,4-Dioxane($C_4H_8O_2$), which is used as a solvent stabilizer, could make harmful effects on ecosystem because of its higher solubility, toxicity and carcinogenic by US EPA. From 2011, its discharge limit to waterbody will be regulated at 5 mg/L by Ministry of Environment Republic of Korea. It was thus to investigate that the currently operating activated sludge in polyester manufacturing processes in Gumi can properly treat it to meet with the regulation standard. For that purpose, the removal rate of 1,4-dioxane and its microbial properties were assessed for a few companies(i.e. K, H and T). Its removal efficiency was the most highly recorded in H as 98% and then 77% for K, which met with the regulation standard. However, concentration of 1,4-dioxane of T was 23 mg/L in the effluent, which is more than the regulation standard. Aside from, microbial degradation test was done for 100 ppm of 1,4-dioxane in BSM (Basal salt medium) inoculated with each of activated sludge. After 7 days, 1,4-dioxane was completely removed in the test bottle inoculated with H sludge, 67% in T and 52% in K, which could confirm that the given activated sludge might have different biodegradability against the amount of 1,4-dioxane. Therefore, microbial diversity in each company was investigated by 16s rDNA cloning methods where a species, e.g. Methylibium petroleiphilum PM1, was the greatest observed from H and in lesser from K, but it was not detected from T. Methylibium petroleiphilum PM1 is known to efficiently degrade ether like methyl tertiary-butyl ether(MTBE). It is concluded that the activated sludge in H can be most effectively adopted for a biodegradation of 1,4-dioxane in the concern of industrial sector.

Consideration about Ozone Generation in the Treatment Room While Treating a Patient (방사선 치료 시 치료실 내에서 발생하는 오존에 관한 고찰)

  • Kwak, Yong-Kuk;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.75-82
    • /
    • 2009
  • Purpose: Measure the ozone level in the treatment room while treating a patient so want to know the degree of contamination caused by ozone occurrence. Materials and Methods: Use the linear accelerator (Clinac 21EX, Varian, USA) with the ozone meter (series-200, aeroQual, New Zealand) and water phantom (Wellhofer, IBA, Germany) is irradiated the radiation so that measured the ozone generation level according to MU, dose-rate, SSD, field size, energy, delay time and put the ozone meter in the treatment room actually while treating a patient so measured the daily ozone level variation. Results: While irradiating the radiation, degree of ozone contamination wasn't affected by the energy but mostly in case of electron beam, ozone level was higher than photon beam. The higher dose-rate (0.016~0.025 ppm/hr), the farther SSD (0.018~0.030 ppm/hr), the wider field sizes (0.016~0.025 ppm/hr), the more MU (0.018~0.046 ppm/hr), it occurred high ozone level. Ozone decrement according to delay time changed the background level (0.016 ppm/hr) after elapsed time of 10 minutes from irradiating radiation. And daily ozone occurrence level in the treatment room was below ozone standard level 0.1 ppm/hr (average:0.06 ppm/8 hr) but it could confirm that ozone generation level was included the level (max:0.038 ppm/hr) above 0.02 ppm/hr which patient could perceive. Conclusion: Through ozone level according to variation of certain conditions, actually in the treatment room ozone generation level didn't damaged to patients or workers. Commonly peoples think that ozone was harmful gas but it thought that small amount of ozone generation level while treating a patient was beneficial in the treatment room through air purge action of pathogenic germ or virus sterilization.

  • PDF

A Study on the Analytical Method of Artificial Sweeteners in Foods (식품 중 인공감미료의 분석법에 관한 연구)

  • Kim, Hee-Yun;Yoon, Hae-Jung;Hong, Ki-Hyung;Lee, Chang-Hee;Park, Sung-Kwan;Choi, Jang-Duck;Choi, Woo-Jeong;Park, Sun-Young;Kim, Ji-Hye;Lee, Chul-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.14-18
    • /
    • 2004
  • Analysis methods of artificial sweeteners, aspartame, acesulfame potassium, sodium saccharin, and sucralose isolated from foods were developed using high performance liquid chromatography, HPLC conditions for aspartame, acesulfame potassium, and sodium saccharin were: column, Symmetry $C_{18}(3.9mm\;i.d{\times}150mm,\;5{\mu}m)$; mobile phase, 0.05M sodium phosphate monobasic : acetonitrile (9 : 1, pH 3.5, containing 0.01M tetrapropylammonium hydroxide); detector, UV detector at 210 nm. HPLC condition for sucralose were : column, Symmetry $C_{18}(3.9mm\;i.d{\times}150mm,\;5{\mu}m)$; mobile phase, water:methanol (7 : 3); detector, refractive index detection (sensitivity = 16). Recoveries of artificial sweeteners in foods including soft drinks, fruit and vegetable beverages, alcoholic beverages, fermented milk beverages, soybean milk, ice cream, snacks, chewing gums, jam, honey, kimchi salted food, special dietary products, processed fish products, candies, food additive mixtures, chocolate and cocoa were 76.1-101.3%, 82.3-103.2%, 83.1-103.7%, and 80,6-99.5% for aspartame, acesulfame potassium, sodium saccharin, and sucralose, respectively.

The Treatment of Heavy Metal-cyanide Complexes Wastewater by $Zn^{+2}/Fe^{+2}$ Ion and Coprecipitation in Practical Plant(I) (아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(I))

  • Lee, Jong-Cheul;Kang, Ik-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.12
    • /
    • pp.1381-1389
    • /
    • 2007
  • Wastewater discharged by industrial activities of metal finishing and electroplating units is often contaminated by a variety of toxic or otherwise harmful substances which have a negative effects on the water environment. The treatment method of heavy metal-cyanide complexes wastewater by alkaline chlorination have already well-known($1^{st}$ Oxidation: pH 10, reaction time 30 min, ORP 350 mV, $2^{nd}$ Oxidation: ORP 650 mV). In this case, the efficiency for the removal of ferro/ferri cyanide by this general alkaline chlorination is very high as 99%. But the permissible limit of Korean waste-water discharge couldn't be satisfied. The initial concentration of cyanide was 374 mg/L(the Korean permissible limit of cyanide is 1.0 mg/L max.). So a particular focus was given to the treatment of heavy metal-cyanide complexes wastewater by $Zn^{+2}/Fe^{+2}$ ion and coprecipitation after alkaline chlorination. And we could meet the Korean permissible limit of cyanide(the final concentration of cyanide: 0.30 mg/L) by $Zn^{+2}/Fe^{+2}$ ion and coprecipitation(reaction time: 30 min, pH: 8.0, rpm: 240). The removal of Chromium ion by reduction(pH: 2.0 max, ORP: 250 mV) and the precipitation of metal hydroxide(pH: 9.5) is treated as 99% of removal efficiency. The removal of Copper and Nickel ion has been treated by $Na_2S$ coagulation-flocculation as 99% min of the efficiency(pH: $9.09\sim10.0$, dosage of $Na_2S:0.5\sim3.0$ mol). It is important to note that the removal of ferro/ferri cyanide of heavy metal-cyanide complexes wastewater should be employed by $Zn^{+2}/Fe^{+2}$ ion and coprecipitation as well as the alkaline chlorination for the Korean permissible limit of waste-water discharge.

Residue levels of phthalic acid esters (PAEs) and diethylhexyl adipate(DEHA) in various industrial wastewaters (업종별 산업폐수 중 프탈산에스테르와 디에틸헥실아디페이트의 잔류수준)

  • Kim, Hyesung;Park, Sangah;Lee, Hyeri;Lee, Jinseon;Lee, Suyeong;Kim, Jaehoon;Im, Jongkwon;Choi, Jongwoo;Lee, Wonseok
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.57-64
    • /
    • 2016
  • Many phthalic acid esters (PAEs), including DMP, DEP, DBP, BBP, and DEHP, as well as DEHA are widely used as plasticizers in plastics. An analytical method was developed and used to analyze these compounds at 41 industrial facilities. The coefficient of determination (R2) for each constructed curve was higher than 0.98. The method detection limit (MDL) values were 0.4–0.7 μg/L for PAEs and 0.6 μg/L for DEHA. In addition, the recovery rate was shown to be 77.0–92.3%, while the relative standard deviation was shown to be in the range of 5.8-10.5%. DMP (n = 3), DEP (n = 2), DBP (n = 2), BBP (n = 2), and DEHA (n = 3) were detected in the range of 2.2-11.1% in the influent. DEHP was a predominant compound and was detected at > MDL in both the influent (n = 16, 35.6%) and the effluent (n = 4, 10.0%) at a high removal efficiency (92–100%). The highest levels of residue in industrial wastewater influent were 137.4 μg/L of DEHP at plastic products manufacturing facility, 12.5 μg/L of DEHA at a chemical manufacturing facility, and 14.0 μg/L of DEP at an electronics facility. The highest concentration of effluent was 12.5 μg/L of DEHP at a chemical manufacturing facility, which indicated that the effluent was below the allowable concentration (800 μg/L). Therefore, the levels of PAEs and DEHA that are discharged into nearby streams could not influence the health of the ecosystem.

Neurobehavioral Performance Test of Workers Exposed to Mixed Organic Solvents (복합유기용제에 폭로된 근로자들에 대한 신경행동학적 기능의 평가)

  • Kim, Chang-Youn;SaKong, Joon;Chung, Jong-Hak;Joo, Ree;Jeon, Man-Joong;Sung, Nag-Jung;Kim, Sang-Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.2
    • /
    • pp.314-328
    • /
    • 1997
  • A cross-sectional study was performed to evaluate the effects of chronic exposure to low-dose solvent on neurobehavioral performance of 48 male workers exposed to organic solvents. A control group of 50 workers was selected from same factories. Each worker completed a medical and occupational questionnaire and four tests of Neurobehavioral Core Test Battery. These included Benton visual retention test, digit symbol, digit span, and pursuit aiming. Comparison of mean performance showed a significantly poorer performance on digit symbol, digit span, and pursuit aiming. In univariate analysis, age contributed to poor performance on Benton visual retention test and educational level was found to reduce the performance on symbol digit in both groups. Amount of alcohol intake was found to reduce the performance on digit symbol and smoking appeared to slow pursuit aiming in the exposure group. In multiple regression analysis, controlling for age, educational level, alcohol, and smoking, Solvent exposure was found to be associated with performance of digit span, and number of correct dot of pursuit aiming. Age on Benton visual retention, educational level on digit symbol, arid smoking on pursuit aiming were found to be a significant factors on each test items. This study suggest that short-term memory, and perception can be affected easily by chronic exposure of organic solvents which air concentration levels were under the Threshold Limit Value.

  • PDF

Proficiency Testing for the Gas-chromatographic Analysis of Procymidone, Chlorpyrifos and Metolachlor Residues in Soil (가스크로마토그래피를 이용한 토양 중 프로사이미돈과 클로르피리포스, 메톨라클로르의 잔류분석 숙련도시험)

  • Kim, Chan-Sub;Son, Kyeong-Ae;Gil, Geun-Hwan;Kim, Jin-Bae;Hong, Su-Myeong;Kwon, Hye-Young
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.94-106
    • /
    • 2013
  • The proficiency testing for the residue laboratories of pesticide registration was conducted in order to improve the reliability and the ability for pesticide residue analysis. On October 2011 the testing was carried out using the soil collected and kept as the moistened state for five years, which is expected to very low residue levels of pesticides. The soil was fortified with chlorpyrifos, metolachlor and procymidone in a manner similar to prepare soil sample for indoor soil degradation test, and then sub-samples were prepared for the distribution to participants. Some of them were randomly selected for confirm of homogeneity and to ensure the stability of samples at room temperature. Samples were consisted of two soil treated as different levels, one of which was used to the assesment and another used to confirm. In addition, provide three standard solutions, respectively concentration of 10 mg/L, and untreated soil. Forty seven institutions submitted results. The medians of results were used as the assigned values for pesticide residues. Fitness for purpose standard deviation of proficiency test was calculated by applying 20% RSD as the coefficient of variation allowed in the soil residue test. Z-score was applied for evaluation of individual pesticides, and the average of the absolute value of the Z-score for the overall assessment of pesticides. Laboratories evaluated the absolute value of the Z-score less than 2 to fit the case of chlorpyrifos and procymidone were 44, metolachlor 40.