• Title/Summary/Keyword: 핵의학 검사

Search Result 663, Processing Time 0.021 seconds

Establishment of Reference Range of Proinsulin (Proinsulin 참고치 설정에 관한 연구)

  • Nam, Yee Moon;Shin, Yong Hwan;Kim, Ji Young;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.76-79
    • /
    • 2013
  • Purpose: It is very important to establish the appropriate reference range in the laboratory for preventing mistakes like false positive or false negative. Because the reference range in the laboratory is standard of patient test results interpretation. Proinsulin is precursor hormone of insulin, and the importance is increasing for diagnosing diabetes or insulinoma. Proinsulin reagent used in our laboratory is produced in the USA, and the reference range provided by manufacturer was adapted to our reference range after the validation test. But, it is generally recommend for the every laboratory to establish the their own reference range. So, we decided to re-evaluate the reference range with our patients' test results. Materials and Methods: Among 737 patients who had been to health promotion center in our hospital between Dec. $8^{th}$ 2011 and Dec. $21^{st}$ 2011, 563 patients are chosen with exception of diabetics patients and patients showing abnormal test results in Fasting Glucose, HbA1c, Insulin, and C-peptide. The 563 test results (275 males and 288 females) were classified with three groups(entire, male, female), and analysis of normal distribution was performed with aid of SPSS(version 19.0). Because Each group didn't show normal distribution, the reference range was set from the lowest limit of 2.5% to the highest limit of 97.5% with Percentile method used in non-normal distribution. Results: When evaluation values are sorted in ascending order, the entire range is 4.5~52.0 pM and 5.3~51.9 pM for male and 4.5~52.0 pM for female. The calculated reference range with percentile method shows 6.7~26.5 pM for entire group, 6.8~26.5 pM for male and 6.7~26.5 pM for female, respectively. Conclusion: The reference range provided by reagent manufacturer is 6.4~9.4 pM and the one established in this study is 6.7~26.5 pM. This difference might be caused by racial characteristics between Western people and Koreans. So an ideal reference range can be gotten with normal population visiting to every hospital. Our hospital has been using the newly re-establishing reference range under consultation with the department of endocrinology since Aug. $1^{st}$ 2012.

  • PDF

Evaluation of Usefulness for Anti-TPO Antibody Test in Item of the Medical Examination (건강검진 종목으로서 항갑상선 과산화효소 항체검사의 유용성에 대한 평가)

  • Kim, Yun-Hyun;Shin, Yong-Hwan;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.112-115
    • /
    • 2009
  • Purpose: The test had been applied for outpatient by end of 2006, however, it has been included in the medical examination since January 2007, as demand and interests have been gradually increasing in the thyroid gland disease and cancer. thus, we would necessarily evaluate usefulness of the test by comparing the number of patients who are diagnosed as "benignancy" by the medical test with the number of outpatient who attend and are diagnosed as autoimmune thyroid disease among the benign patient, in samsung medical center for a certain period. Materials and Methods: Based on the result for Anti-TPO Antibody test by RIA for the 12,937 patients in samsung medical center from October 2007 to March 2008, for six months, benignancy rate classified by sex and age is measured statistically and number of the patients who are diagnosed as autoimmune thyroid disease are kept tracked on. Results: According to the analysis of the Anti-TPO antibody test 1,135 of 12,937, which is 8.77% are benign and 218 treated patient of them, which is 19.2%, were diagnosed as autoimmune thyroid disease. Conclusions: Based on the statistics, usefulness of the test seem to have co relationship with derivation of autoimmune thyroid disease. this is 19.2% of probability relatively high. this figure, however, does not have strong relationship with specialty of the disease. Thus screening test seems to have somewhat effectiveness, considering other experiments and their margin.

  • PDF

Usefulness about BSGI (Breast Specific Gamma Imaging) in Breast Cancer Patients (유방암 환자에서 Breast Specific Gamma Imaging (BSGI)의 유용성)

  • Cho, Yong-Gwi;Pyo, Seong-Jae;Kim, Bong-Su;Shin, Chea-Ho;Cho, Jin-Woo;Yeo, Ji-Yeon;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.92-101
    • /
    • 2009
  • Purpose: Scintimammography is one of the screening tests for the early diagnosis of breast cancer. It has been widely accepted as very useful in assessing masses that have not been detected in breast scanning. This method is highly sensitive and specific with respect to the diagnosis of primary and relapsing breast cancer. It has some difficulties, however, in detecting tumors sized 1 cm and below due to the radioactivity around the breast and the geometrical structure of the equipment. The recent introduction of high-resolution Breast-specific Gamma Imaging (BSGI) has made it possible to more accurately discriminate between malignant and benign tumors than with any other test method. Thus, the possibility of an unnecessary biopsy being performed has decreased. The purpose of this study was to examine the diagnostic capacity of mammography, breast sonography, and scintimammography, which are used for the early diagnosis of known breast cancer, and of BSGI, and to evaluate the skillfulness of radiologists. Materials and Methods: The 53 volunteers participants who had no clinical manifestation of breast cancer underwent the BSGI in February 2009. In the BSGI procedure, scanning images were obtained from the craniocaudal projection (CC) and the mediolateral Oblique projection (MLO), as well as from the additional $80{\times}80$-matrix-sized views at various angles in the Present Time method, 10 minutes after the 25 mCi $^{99m}Tc$-MIBI was injected. Results: The results of the BSGI showed that two participants had masses in their breast tissue. As the results of the diagnosis of four participants were not clear, they were retested and the results of the second test were negative. The results of the clinical screening test for breast cancer showed that the sensitivity of BSGI, scintimammography, mammography, and breast sonography was 86.5%, 77.8%, 85~90%, and 66.7%, respectively, and that their specificity was 92.4%, 84.2%, 20~42%, and 68%, respectively. Conclusion: The autodiagnosis and breast cancer screening test are needed for the early diagnosis of breast cancer. It was not easy, however, to accurately determine the presence of a mass in the breast using the existing breast cancer screening test. The patients with unclear test findings were made to undergo a histologic biopsy for a more accurate diagnosis. It is expected that the BSGI can provide useful information for the early diagnosis of breast cancer and of primary breast cancer, and will reduce the performance of unnecessary biopsies because of its higher sensitivity and specificity than existing breast cancer screening tests.

  • PDF

Quantitative Evaluation of Dysphagia Using Scintigraphy (신티그라피를 이용한 연하곤란증의 정량적 평가)

  • Park, Seok-Gun;Hyun, Jung-Keun;Lee, Seong-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.276-289
    • /
    • 1998
  • Purpose: To evaluate dysphagia objectively and quantitatively, and to clarify the effect of neck position and viscosity changes in patients with aspiration and laryngeal penetration. Materials and Methods: We studied 35 patients with dysphagia and 21 normal controls using videofluoroscopy and scintigraphy. Videofluoroscopy was performed with barium with three different viscosity, and scintigraphy was done with water, yogurt, and steamed egg mixed with Tc-99m tin colloid. If aspiration was found during videofluoroscopic examination, patient's neck position was changed and study repeated. Videofluoroscopy was analyzed qualitatively. We calculated 7 quantitative parameters from scintigraphy. According to the videofluoroscopic findings, we divided patients into 3 subgroups; aspiration, laryngeal penetration, and no-aspiration group. Results: The result of videofluoroscopy revealed that the most common finding was the delay in triggering pharyngeal swallow. Pharyngeal transit time (PTT) and pharyngeal swallowing efficiency(PSE) in patients with aspiration were signifi-cantly different from other groups. After neck position change, aspiration could be reduced in all of 7 patients, and laryngeal penetration reduced by about 82%. PTT and PSE were also improved after position change. Aspiration and laryngeal penetration occurred more frequently in thin liquid swallowing than in thick liquid and solid swallowing. Conclusion: PTT and PSE were useful for the evaluation of dysphagia. Aspiration and laryngeal penetration could be reduced when appropriate position assumed. We could decrease the chance of aspiration by changing the patient diet consistency. Scintigraphy might be useful tool to quantitate and follow up these changes.

  • PDF

Crossed Cerebellar and Cerebral Cortical Diaschisis in Basal Ganglia Hemorrhage (기저핵 출혈에 의한 교차 소뇌 해리 현상)

  • Lim, Joon-Seok;Ryu, Young-Hoon;Kim, Hee-Joung;Lee, Byung-Hee;Kim, Byung-Moon;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.397-402
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the phenomenon of diaschisis in the cerebellum and cerebral cortex in patients with pure basal ganglia hemorrhage using cerebral blood flow SPECT. Materials and Methods: Twelve patients with pure basal ganglia hemorrhage were studied with Tc-99m ECD brain SPECT. Asymmetric index (AI) was calculated in the cerebellum and cerebral cortical regions as |$C_R-C_L$/$(C_R-C_L){\times}200$, where $C_R$and $C_L$ are the mean reconstructed counts for the right and left ROIs, respectively. Hypoperfusion was considered to be present when AI was greater than mean +2 SD of 20 control subjects. Results: Mean AI of the cerebellum and cerebral cortical regions in patients with pure basal ganglia hemorrhage was significantly higher than normal controls (p<0.05): Cerebellum ($18.68{\pm}8.94$ vs $4.35{\pm}0.94$, $mean{\pm}SD$), thalamus ($31.91{\pm}10.61$ vs $2.57{\pm}1.45$), basal ganglia ($35.94{\pm}16.15$ vs $4.34{\pm}2.08$), parietal ($18.94{\pm}10.69$ vs $3.24{\pm}0.87$), frontal ($13.60{\pm}10.5$ vs $4.02{\pm}2.04$) and temporal cortex ($15.92{\pm}11.95$ vs $5.13{\pm}1.69$). Ten of the 12 patients had significant hypoperfusion in the contralateral cerebellum. Hypoperfusion was also shown in the ipsilateral thalamus (n=12), ipsilateral parietal (n=12), frontal (n=6) and temporal cortex (n=10). Conclusion: Crossed cerebellar diaschisis (CCD) and cortical diaschisis may frequently occur in patients with pure basal ganglia hemorrhage, suggesting that CCD can develop without the interruption of corticopontocerebellar pathway.

  • PDF

Current Status and Improvements of Transfered PET/CT Data from Other Hospitals (외부 반출 PET/CT 영상 현황 및 개선점)

  • Kim, Gye-Hwan;Choi, Hyeon-Joon;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.38-40
    • /
    • 2010
  • Purpose: This study was performed to find the current problems of PET/CT data from other hospitals. Materials and Methods: The subjects were acquired from 64 hospitals referred to our department for image interpretation. The formats and contents of PET/CT data were reviewed and the phone questionnaire survey about these were performed. Results: PET/CT data from 39 of 64 hospitals (61%) included all transaxial CT and PET images with DICOM (Digital Imaging Communications in Medicine) standard format which were required for authentic interpretation. PET/CT data from the others included only secondary capture images or fusion PET/CT images. Conclusion: The majority of hospitals provided limited PET/CT data which could be inadequate for accurate interpretation and clinical decision making. It is necessary to standardize the format of PET/CT data to transfer including all transaxial CT and PET images with DICOM standard format.

  • PDF

Increase of Tc-99m RBC SPECT Sensitivity for Small Liver Hemangioma using Ordered Subset Expectation Maximization Technique (Tc-99m RBC SPECT에서 Ordered Subset Expectation Maximization 기법을 이용한 작은 간 혈관종 진단 예민도의 향상)

  • Jeon, Tae-Joo;Bong, Jung-Kyun;Kim, Hee-Joung;Kim, Myung-Jin;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.344-356
    • /
    • 2002
  • Purpose: RBC blood pool SPECT has been used to diagnose focal liver lesion such as hemangioma owing to its high specificity. However, low spatial resolution is a major limitation of this modality. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. We compared this new modified iterative reconstruction method, OSEM with conventional filtered back projection (FBP) in imaging of liver hemangioma. Materials and Methods: Sixty four projection data were acquired using dual head gamma camera in 28 lesions of 24 patients with cavernous hemangioma of liver and these raw data were transferred to LINUX based personal computer. After the replacement of header file as interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging. The best condition for imaging in our investigation was considered to be 4 iterations and 16 subsets. After then, all the images were processed by both FBP and OSEM. Three experts reviewed these images without any information. Results: According to blind review of 28 lesions, OSEM images revealed at least same or better image quality than those of FBP in nearly all cases. Although there showed no significant difference in detection of large lesions more than 3 cm, 5 lesions with 1.5 to 3 cm in diameter were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions less than 1.5 cm. Conclusion: OSEM revealed better contrast and define in depiction of liver hemangioma as well as higher sensitivity in detection of small lesions. Furthermore this reconstruction method dose not require high performance computer system or long reconstruction time, therefore OSEM is supposed to be good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.

Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source (Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Park, Hae-Jung;Kwon, Yun-Youn;Son, Hye-Kyoung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.96-99
    • /
    • 2004
  • The objective of this study is to assess attenuation correction algorithms utilized in a multipurpose whole-body GSO PET scanner. Four different types of phantoms were tested using different types of attenuation correction techniques. FOV (Field of View) of 256mm was used for brain PET imaging. For compensating attenuation, transmission data of a $^{137}$Cs point source were acquired after the F-18 emission source was infused to the phantoms. Scatter correction were peformed. Reconstructed images of the phantoms were assessed. In addition, reconstructed images of a normal subject were compared and assessed by nuclear medicine physicians. As a result, decreased intensity at the central portion of the attenuation map with cylindrical phantom was noticed during use of the measured attenuation correction. On the other hand, segmentation or remapping attenuation correction provided uniform phantom image. the images reconstructed from the clinical brain data explained the attenuation of a skull, at though reconstructed images of the phantoms couldn't explain it. in conclusion, the complicated and improved attenuation correction methods were required to obtain the better accuracy of the quantitative brain PET images. Our study will be useful in improving quantitative brain PET imaging modalities with attenuation correction of $^{137}$Cs transmission source.

  • PDF

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF