• 제목/요약/키워드: 핵의학 검사

검색결과 663건 처리시간 0.024초

PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향 (Effect of Extended Field of View on Measurements of Standardized Uptake Value in PET/CT)

  • 박순기;남기표;김경식;신상기
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.82-85
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of extended CT field of view (FOV) on PET/CT of Standardized uptake value (SUV) when imaging extends beyond the CT FOV. Materials and Methods: CT images were reconstructed at different FOV sizes (500 and 700 mm). Two sets of CT images were reconstructed from the CT projection data by using two FOV sizes. Twenty patients were used in this study. PET images were reconstructed using attenuation maps with 500 mm CT FOV and 700 mm extended CT FOV images. Region of interests (ROIs) drawn on the PET images. In addition, twenty patients' PET images reconstructed by 500 mm CT FOV and 700 mm extended CT FOV were compared with $SUV_{max}$. Results: When using attenuation maps with 700 mm extended CT FOV, the $SUV_{max}$ analysis of liver (p=0.000), lung (p=0.007), mediastinum (p=0.001) were statistically significant. Conclusions: 700 mm extended CT FOV helps to recover the true activity distribution in the PET emission data. In addition, 700 mm extended CT FOV has affected SUV measurement of liver, lung, mediastinum.

  • PDF

Cr-51 EDTA GFR 검사 결과의 분석 및 의의 (Estimation of Glomerular Filtration Rate using Chromium-51 EDTA)

  • 임수연;문형호;유선희;조시만
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.98-103
    • /
    • 2009
  • Purpose: Correct estimation of Glomerular filtration rate (GFR) is very important for an accurate clinical assessment of the kidney function. This study compares four GFR markers, a serum creatinine-based estimation using MDRD formula, Cystatin-C, Cr-51 EDTA 2 samples and 6 samples. Materials and Methods: Serum creatinine concentrations, Cystatin-C serum concentrations and Cr-51 EDTA clearance are measured in 43 patients who received or donated kidney. Results: The correlation coefficient between serum based estimated GFR (MDRD) and Cr-51 EDTA 6 samples was 0.817 (p<0.01). The correlation coefficient between Cystatin-C based GFR and EDTA 6 samples was 0.7322 (p<0.01). Regression analysis showed a statistically significant correlation between Cr-51 EDTA 2 samples and 6 samples (r=0.971, p<0.01). Mean value and ${\pm}2SD$ for the difference between Cr-51 EDTA 2 samples and 6 samples were 4.7 mL/min and ${\pm}9.3$ respectively. Conclusions: The estimation of two samples Cr-51 EDTA showed that the method can be simplified by reducing blood samples without losing its high accuracy.

  • PDF

폐소공포증 환자의 핵의학 영상검사에 관한 연구 (Study of Nuclear medical imaging tests patient of Claustrophobia)

  • 강용길;홍진웅;양한준;박성수;이귀원;김긍식
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.55-59
    • /
    • 2013
  • Patients who had claustrophobia tend to feel fear when they were scanned by an MRI, CT, PET-CT, or using a gamma camera scan. In this paper, claustrophobic patients were tested to find effective ways by changing patient's positions. For this paper, PET-CT scan in patients who had claustrophobia were used in the prone position. Prone position helped to maintain stable position and to get a h0igh quality of inspection without failure. Thus, as claustrophobic patients were requested taking prone position, they could feel comfortable. In a confined space, prone position for the claustrophobic patients who had a fear of the PET-CT examination would be expected to reduce the failure rate of inspection.

  • PDF

핵의학 검사실내 세균 분석 (Analysis of the Bacteria in Nuclear Medicine)

  • 신성규;이효영
    • 대한안전경영과학회지
    • /
    • 제19권2호
    • /
    • pp.95-100
    • /
    • 2017
  • In this study, the bacterial contamination level of equipments and devices in the nuclear medicine department of a university hospital was investigated. CNS was detected from the sample collected from the door opening button of the nuclear medicine department. Bacillus sp. was detected from the table and CNS with Bacillus sp. were detected from the control button at the PET-CT room no.1. Also, CNS was detected from the table and the control button at the PET-CT room no.2. In the distribution room no.1, CNS and Bacillus sp. were detected while CNS being detected from the distribution room no.2 and CNS with Bacillus sp. being detected from the distribution room no.3. In the injection room, Enterrococcus faecium and Pontoea sp. were detected. On the table of the ecsomatics room, Pontoea sp. was detected. Bacillus sp. was detected from the inside of the syringe Pb shield and CNS was detected from the outside. Enterrococcus faecium was detected from the Gamma camera table and Bacillus sp. was detected from the door grip. On the chair at the patient waiting room, Pseudomonas aeruginosa abd Bacillus sp. were detected. Therefore, it was understood that infection should be prevented by securely sterilizing examination devices after each examination, maintaining cleanliness by regular sterilization of waiting chairs and such objects with a number of direct contacts with patients, and infection education for the features of nuclear department.

PET/CT 팬텀의 3D 프린팅 소재 적용 가능성 평가 (Evaluation of the Applicability of PET/CT Phantom as a 3D Printing Material)

  • 이주영;김지현;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.423-431
    • /
    • 2022
  • The purpose of this study is to present objective information in applying 3D printing technology for PET/CT (Positron Emission Tomography/Computed Tomography) performance evaluation and use it as a basic research that can be applied to various purposes in the future. Phantoms were manufactured with step wedge of ABS(Acrylonitrile Butadiene Styrene) and ACR(Acrylic acid) material. The counts for each ROI(Region of Interest) were analyzed through image acquisition in PET/CT. And the variation rate of counts and CNR(Contrast Noise Ratio) was evaluated. In the counts analysis, the effect of thickness occurred. In addition, in the variation rate analysis, the thickness setting of steps wedge 4 to 5 levels should be considered first. These results minimize quantitative and qualitative changes in the phantom manufactured based on 3D printing, and enable more stable PET/CT performance evaluation. Based on 3D printing in PET/CT, various phantoms are expected to be produced in the future. If the characteristics of each material are considered and applied through the basic research such as this research, the result of the phantom manufactured through 3D printing can be more meaningful and will be used in a wide range.

DXA 골밀도 검사에서 방사선사가 인식하고 있어야 할 Pitfall (The Pitfalls Medical Radiological Technologists should Consider in Bone Densitometry)

  • 김호성
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.11-22
    • /
    • 2023
  • Bone densitometry is a disease in which bones are easily broken due to metabolic bone disease, and DXA is used as a clinical standard test. Although DXA is a good method with good accuracy and reproducibility, it is frequently subject to test errors in testing and result analysis and analysis. Therefore, it is important to recognize the error issues that radiologists should basically be aware of when performing bone density tests, prevent erroneous diagnoses and treatments resulting from the results, and reduce the unnecessary costs associated with them. aim. The inspection must be carried out if the quality control of the equipment is basically continuously performed well before the inspection. Before starting the examination, the patient's age, sex, race, weight, pregnancy status, and any foreign objects that can be removed should be checked, and the examination should be performed in the correct posture. In addition, it is important to analyze results consistently. Radiologists, who play the most important role in ensuring accurate examinations, need to be aware of the potential for errors in advance and develop the ability to deal with the potential for errors in each examination. For that reason, regular education is considered essential.

  • PDF

만성B형 간염에서 HBe 항원에서 항체로의 혈청 전환 중에 불안정하게 나타나는 HBe 항원 (Unstable Data of HBe Antigen during Seroconversion from HBe Antigen to Antibody in Chronic Type B Hepatitis)

  • 신선영;민경선;노경운;김현주
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.78-81
    • /
    • 2008
  • 목적: 본 연구의 목적은 치료제를 복용하는 만성 B형간염환자의 혈청에서 seroconversion되는 과정 중에 불안정하게 나타나는 HBeAg과 HBeAb 사례를 연구하여, 검사자가 검사결과에 대한 정확한 이해를 하는데 도움을 주고자 하는 것이다. 방법: 만성 B형간염 환자로 진단을 받고 치료제를 복용하고 HBeAg 검사와 HBeAb검사를 시행한 3명을 대상으로 하였다. HBeAg과 HBeAb검사는 Radioimmunoassay법과 Immunoradiometric assay법으로 실시되었다. 결과: HBeAg이 음성화되는 과정에서 결과가 양성에서 음성으로, 다시 양성으로 불안정한 결과를 보였다. HBeAb가 양성화되는 과정에서 결과가 음성에서 양성으로, 다시 음성으로 변하는 불안정한 결과를 보였다. 결론: 이번 사례는 seroconversion 유도를 위해 약물치료중인 만성 B형간염 환자에서 볼 수 있는 불안정한 HBeAg과 HBeAb 혈액 결과이다. 불안정한 HBeAg과 HBeAb 검사 결과를 통하여 검사자는 환자가 바이러스 치료제를 복용하여 seroconversion되는 과정 중에 있을 수 있다는 것과 불안정한 결과는 치료제에 의해 일어나는 자연스러운 현상임을 알 수 있다.

  • PDF

Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교 (The comparison of lesion localization methods in breast lymphoscintigraphy)

  • 연준호;홍건철;김수영;최성욱
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.74-80
    • /
    • 2015
  • 유방 림프절 검사는 유방암이 있는 환자들에게 외과적 수술 전 후에 검사가 시행되고, 악성 종양의 림프절 전이를 조기에 진단할 수 있는 검사방법으로 검사 시 체표윤곽을 정확하게 나타내는 것이 중요하다. 현재 대부분 병원에서 $^{99m}Tc$ 점선원 또는 $^{57}Co$ 면선원을 이용한 방법을 사용하고 있다. 따라서 본 논문에서는 위의 두 가지 방법 외에 $10m{\ell}$ 주사기를 이용하는 방법, 산란선 광자에너지를 이용한 방법, SPECT/CT에서 scout촬영을 이용한 방법을 추가하여 영상에서 위치 정보를 유용하게 제공하는 방법과 피폭선량을 비교 및 평가하고자 한다. Rando phantom과 SYMBIA T16 장비를 사용하였으며 Phantom의 우측 13번째에 0.11 MBq의 점선원을 삽입하여 종양을 만들었고, 우측 유방 위치에 37 MBq의 점선원으로 주사 부위를 만들었다. 첫 번째 방법은 $^{99m}Tc$ 점선원으로 Phantom의 체표윤곽을 30초 동안 그려 영상을 획득하는 방법이며, 두 번째는 $^{57}Co$ 면선원을 환자의 후면부와 좌측면에 위치하여 30초 동안 체표윤곽을 얻는 방법이며, 세 번째는 $^{99m}TcO_4$ 37 MBq와 생리식염수로 채운 $10m{\ell}$ 주사기를 이용한 방법이다. 그리고 네 번째는 선원 없이 $^{99m}Tc$의 에너지와 scatter의 광자 에너지를 이용한 방법이며, 마지막은 SPECT/CT의 scout영상과 유방 영상을 전선화 코드를 이용하여 융합하는 방법이다. 이때 전면 영상과 우측 영상을 각각 3분씩 얻었으며 검사 시 개인피폭 선량계(ECOTEST, DKG-21)를 사용하여 피폭선량을 계측하였다. 각각의 영상을 종양 대 배후 방사능 비(TBR)와 피폭선량을 비교 및 분석하였으며 다섯 가지 방법의 영상을 방사선사와 핵의학 전공의에게 설문조사를 하여 선호도를 파악하였다. 첫 번째 방법에서의 종양 대 배후 방사능 비의 값은 전면 영상은 334.9, 우측 영상은 117.2이며 피폭선량은 $2{\mu}\;Sy$가 계측되었고, 두 번째 방법에서는 각각 266.1, 124.4, $2{\mu}\;Sy$로 평가되었고, 세 번째 방법에서는 117.4, 99.6, $2{\mu}\;Sy$로 평가되었으며 네 번째 방법에서는 3.2, 7.6이며 $0{\mu}\;Sy$로 평가되었다. 그리고 마지막 방법에서의 565.6, 141.8, $30{\mu}\;Sy$로 평가되었다. TBR값은 마지막 방법이 가장 높았고 네 번째 방법이 가장 낮았다. 또한 피폭선량은 마지막 방법이 가장 높았으며 네 번째 방법이 가장 낮았다. 그리고 설문 조사 결과는 마지막 방법이 가장 좋은 점수가 나왔고 네 번째 방법이 가장 낮은 점수가 나왔다. 유방 림프절 검사는 유방암이 있는 환자들에게 검사 시 종양의 위치를 정확하게 영상화하는 것이 중요하다. 실험 결과 SPECT/CT의 scout 촬영을 이용한 검사 방법은 종양 대 배후 방사능 비의 값이 가장 좋고 설문 조사 결과에서도 가장 좋은 점수를 얻어 영상에서 환자의 위치 정보를 유용하게 제공해주는 방법으로 평가되었다. 그러나 피폭 선량은 SPECT/CT의 scout 촬영 시 다른 검사방법보다 많이 나왔으나 일반인의 연간 피폭선량한도인 1 mSy를 기준으로 비교하면 피폭량은 미미하다고 할 수 있다. Scout촬영 시 80 kV이하로 검사가 가능하다면 피폭선량도 줄이고 환자의 위치 정보를 유용하게 영상화 할 수 있는 방법이 될 수 있을 것이다.

  • PDF

$^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가 (The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan)

  • 심동오;김호성;정은미
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.117-121
    • /
    • 2010
  • 핵의학 검사에서 정적 영상을 획득하는 방법은 총 계수 설정법(preset count method)과 시간 설정법(preset time method)이 있다. $^{99m}Tc$-DMSA를 이용한 정적 신장 검사는 총 계수 설정법을 주로 사용하고 있지만 시간 설정법을 사용하는 곳도 있다. 총 계수 설정법을 사용하는 경우는 매번 동일한 계수를 획득하게 되지만 검사 시간은 차이가 있고, 시간 설정법의 경우는 검사 시간은 일정하지만 동일하지 못한 계수가 획득되게 된다. 따라서, 본 연구에서는 획득되는 계수에 따른 좌우 신장의 기능 및 형태 정보에 어떠한 차이가 있는 지 알아보고자 하였다. 2010년1월11일부터 3월31일까지 서울아산병원 핵의학과에서 $^{99m}Tc$-DMSA 신장 검사를 시행한 환자 중 한쪽 신장의 상대적 기능이 40~60%인 30명(남:여=11:19)의 환자를 대상으로 하였으며, 신장 내에 냉소나 열소가 존재하여 신장 피질의 구분이 명확하지 않은 경우는 제외하였다. 대상자의 나이는 $14.83{\pm}22.07$세로서 성인과 소아를 따로 구분하지 않았으며, 검사 시 이용한 장비는 PHILIPS사의 BrigthView 감마카메라를 사용하였다. 신장의 기능 및 형태 분석을 위해서는 동일 회사의 JET stream release 3.0 version을 이용하였고, 통계 분석은 SPSS 12.0을 사용하여 기술통계, 대응 표본 t 검정 (paired t-test)을 시행하였다. 영상은 다른 검사인자들을 모두 동일하게 설정하고 획득 계수를 10만 계수와 30만 계수, 그리고 획득 시간을 7분 (30만 계수 초과)으로 변경하여 연속적으로 획득하였고, 신장의 기능 및 형태 정보를 평가하기 위해서 좌우 신장의 상대적 기능(renal relative function)과 기하평균(geometric mean) 그리고 신장의 크기(Size)를 측정하였으며 그에 따른 각각의 차이를 비교 분석하였다. 좌우 신장의 상대적 기능(좌측 신장 기준)의 경우 10만 계수는 $50.52{\pm}3.61%$, 30만 계수는 $50.38{\pm}3.66%$, 7분 획득은 $50.31{\pm}3.64%$였으며 각 방법 간에 통계적으로 유의한 차이는 없었다. 기하 평균(좌측 신장 기준)의 경우 10만 계수는 $50.08{\pm}3.25%$, 30만 계수는 $49.89{\pm}3.40%$, 7분 획득은 $49.91{\pm}3.24%$였으며 이 역시 통계적으로 유의한 차이는 없었다. 신장의 크기 중 좌측의 경우 10만 계수는 $8.23{\pm}1.96$ cm, 30만 계수는 $8.35{\pm}1.97$ cm, 7분 획득은 $8.45{\pm}2.01$ cm이었고, 각 방법 간에는 통계적으로 유의한 차이를 나타내었다(p<0.05). 우측 신장의 경우 10만 계수는 $7.91{\pm}1.88$ cm, 30만 계수는 $8.12{\pm}1.90$ cm, 7분 획득은 $8.25{\pm}1.96$ cm이었으며, 각 방법 간에는 통계적으로 유의한 차이를 나타내었다(p<0.05). 본 연구 결과에 의하면 획득 계수에 따른 좌우 신장의 상대적 기능과 기하 평균은 통계적으로 유의한 차이가 없었지만, 신장의 형태는 획득 계수가 증가할수록 크기가 증가하는 경향을 보였으며 통계적으로도 유의한 차이를 나타내었다. 따라서, 정적 신장 검사의 신뢰성 있는 정량 평가를 위해서는 시간 설정법보다 총 계수 설정법을 사용하는 것이 바람직할 것이다. 특히, 추적검사의 경우는 시간 설정법을 사용하면 검사 시마다 획득되는 계수가 다르게 되어 신장의 형태 평가에 차이를 발생시킬 것이다.

  • PDF

관동맥질환의 진단을 위한 아데노신 Tc-99m sestaMIBI SPECT의 재현성 (Reproducibility of Adenosine Tc-99m sestaMIBI SPECT for the Diagnosis of Coronary Artery Disease)

  • 이덕영;배진호;이상우;천경아;유정수;안병철;하정희;채성철;이규보;이재태
    • 대한핵의학회지
    • /
    • 제39권6호
    • /
    • pp.473-480
    • /
    • 2005
  • 목적: 아데노신 부하 Tc-99m MIBI SPECT는 관동맥질환의 진단, 예후 평가, 치료 방침의 설정, 치료 효과 판정 및 경과 관찰에 유용성이 있다고 알려져 있다. 치료 효과 판정 및 치료 방침 설정을 위해서는 검사 방법의 재현성이 높아야 한다. 본 연구는 아데노신 부하 Tc-99m MIBI SPECT의 재현 성능을 평가하기 위하여 동일인에서 2회 연속적으로 시행한 아데노신 부하 Tc-99m MIBI SPECT에서 약물주사에 따른 혈역학적 변화와 부작용의 빈도, 영상에 나타난 심근분절의 방사능섭취 정도의 차이를 알아 보고자 하였다. 대상 및 방법: 관동맥질환이 의심되거나 관동맥질환으로 진단된 후 추적검사를 위하여 아데노신 부하 Tc-99m MIBT SPECT를 시행한 30명의 환자를 대상으로 2-11 일(평균: 4.1 일)의 간격으로 검사를 반복하였다. 관류영상의 육안적 판독은 좌심실의 단층 영상을 18분절로 구분하여, 섭취 정도에 따라 4등급으로 분류하였고, 관류 정도의 평가는 2명의 핵의학 전공의사가 각각 평가한 후 일치하지 않은 경우에는 두 판독자 간에 토의로 합의된 소견으로 비교하였다. 결과: 아데노신 주사에 따른 수축기혈압, 이완기 혈압 및 맥박 수의 변화는 두 검사 사이에 유의한 차이가 없었고, 두 번의 검사를 시행하는 동안 검사를 중지하거나 부작용 치료를 위한 처치를 받아야 만큼 중독한 부작용의 발생은 없었다. 관류점수상 540분절 중 439분절에서 완전하게 일치하였고(일치도 81.3%, tau B index 0.73%), 1점 차이(97분절, 18%), 2점 차이(4분절, 0.7%)있었으나 3점 이상의 차이가 있은 경우는 없었다. 두 검사에서 측정된 관류결손의 범위와 중증도점수 사이에는 각각 $\gamma$-값 0.982와0.965의 높은 양의 상관성을 나타내었다(p<0.001, respectively). 결론: 연속적으로 2회 시행한 아데노신 부하 Tc-99m MIBI SPECT는 부하에 따른 혈역학적 변화 및 부작용의 발생이 유사하였고, 심근분절의 관류상태의 시각적 평가 및 관류결손의 정량적 판정에서 매우 높은 재현성을 보여주었다. 그러므로 아데노신 Tc-99m MIBI SPECT는 관동맥질환이 의심되거나 관동맥질환으로 진단된 환자에서 약물치료나 중재적 시술 또는 외과적 수술 치료 후 심근관류상태의 경시적 변화를 평가하는데 유용하게 이용될 수 있을 것이라 판단된다.