• Title/Summary/Keyword: 핵발전

Search Result 179, Processing Time 0.03 seconds

Validity and Pertinence of Administrative Capital City Proposal (행정수도 건설안의 타당성과 시의성)

  • 김형국
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.2
    • /
    • pp.312-323
    • /
    • 2003
  • This writer absolutely agrees with the government that regional disequilibrium is severe enough to consider moving the administrative capital. Pursuing this course solely to establish a balanced development, however, is not a convincing enough reason. The capital city is directly related to not only the social and economic situation but, much more importantly, to the domestic political situation as well. In the mid-1970s, the proposal by the Third Republic to move the capital city temporarily was based completely on security reasons. At e time, the then opposition leader Kim, Dae-jung said that establishing a safe distance from the demilitarized zone(DMZ) reflected a typically military decision. His view was that retaining the capital city close to the DMZ would show more consideration for the will of the people to defend their own country. In fact, independent Pakistan moved its capital city from Karachi to Islamabad, situated dose to Kashmir the subject of hot territorial dispute with India. It is regrettable that no consideration has been given to the urgent political situation in the Korean peninsula, which is presently enveloped in a dense nuclear fog. As a person requires health to pursue his/her dream, a country must have security to implement a balanced territorial development. According to current urban theories, the fate of a country depends on its major cities. A negligently guarded capital city runs the risk of becoming hostage and bringing ruin to the whole country. In this vein, North Koreas undoubted main target of attack in the armed communist reunification of Korea is Seoul. For the preservation of our state, therefore, it is only right that Seoul must be shielded to prevent becoming hostage to North Korea. The location of the US Armed Forces to the north of the capital city is based on the judgment that defense of Seoul is of absolute importance. At the same time, regardless of their different standpoints, South and North Korea agree that division of the Korean people into two separate countries is abnormal. Reunification, which so far has defied all predictions, may be realized earlier than anyone expects. The day of reunification seems to be the best day for the relocation of the capital city. Building a proper capital city would take at least twenty years, and a capital city cannot be dragged from one place to another. On the day of a free and democratic reunification, a national agreement will be reached naturally to find a nationally symbolic city as in Brazil or Australia. Even if security does not pose a problem, the governments way of thinking would not greatly contribute to the balanced development of the country. The Chungcheon region, which is earmarked as the new location of the capital city, has been the greatest beneficiary of its proximity to the capital region. Not being a disadvantaged region, locating the capital city there would not help alleviate regional disparity. If it is absolutely necessary to find a candidate region at present, considering security, balanced regional development and post-reunification scenario of the future, Cheolwon area located in the middle of the Korean peninsula may be a plausible choice. Even if the transfer of capital is delayed in consideration of the present political conflict between the South and the North Koreas, there is a definite shortcut to realizing a balanced regional development. It can be found not in the geographical dispersal of the central government, but in the decentralization of power to the provinces. If the government has surplus money to build a new symbolic capital city, it is only right that it should improve, for instance, the quality of drinking water which now everyone eschews, and to help the regional subway authority whose chronic deficit state resoled in a recent disastrous accident. And it is proper to time the transfer of capital city to coincide with that of the reunification of Korea whenever Providence intends.

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Oestrogenic Activity of Parabens in Uterotrophic Assay (자궁비대시험 연구에서 에틸, 프로필, 이소프로필, 부틸, 이소부틸 파라벤의 내분비독성)

  • Jo Eun-Hye;Jung Ji-Youn;Park Cheol-Beom;Park Sun-Hee;Shim Yhong-Hee;Kang Dae-Hyuck;Lee Sung-Ho;Yu Jong-Hoon;Kim Sun-Jung;Lee Sung-Hoon;Park Jung-Ran;Lee Yong-Soon;Kang Kyung-Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.2
    • /
    • pp.118-128
    • /
    • 2006
  • This study was conducted to determination of the endocrine distruptor function of 'Parabens' by dosing ethyl paraben, propyl paraben, isopropyl paraben, butyl paraben and isobutyl paraben to the immature SD rats. 18 groups were given vehicle control group, negative control group (Dibutyl phthalate), postive control group ($1'7-{\alpha}$ Ethynylestrdiol) and each paraben groups involved 3 dose level. Rats were injected with 62.5, 250 and 1,000mg/kg from postnatal day 19 till 21 once a day in subcutaneous and a total 3, times. There was no treatment related death. but, subcutaneous nodule, edema, alopecia and scrub formation on injection site was observed. These signs was become worse in high dose level. these signs was cause from physical stimulation by test substance which parabens were mix with com oil as vehicle. In the analysis of organ weights, absolute and relative weights of brain, spleen, liver, thymus, heart, kidneys, adrenals, ovaries and vagina were no difference with control group. but, wet and blotted weight of uterus was increased in every high dose parabens treat group. Especially, all dose level of isobutyl paraben was showed increment of uterus weight. uterus dilatation of parabens treated group was observed in gross anatomic pathology and these result was agree with wet and blotted weight of uterus. In the result of this study, estrogenic effect as endocrine distruptor was observed in ethyl paraben, propyl paraben, isopropyl paraben, butyl paraben and isobutyl paraben. and it was considered isobutyl paraben has highest estrogrnic effect under the condition of this study.

The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT (PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가)

  • Kim, Jin-Young;Lee, Seung Jae;jung, Suk;Park, Min-Soo;Kang, Chun-Goo;Im, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose Among various causes that influence image quality degradation, various methods for decrease in Artifact occurred by respiration of patients are being used. Among them, this study intended to evaluate CTAC Shift correction method and additional scan compare to the Scan(Q static scan) using respiratory gated system. Materials and Methods This study was conducted on 10 patients, and used PET-CT Discovery 710 (GE Healthcare, MI, USA) and Varian's RPM system. 5.18 Mbq per kg of $^{18}F$-FDG was injected on patients, asked them to take a rest for 1 hour in the bed, and conducted test after urination. Images were visualized through Q static scan, CTAC Shift correction method, Additional scan based on the Whole body scan(WBS) with Artifact. Decrease in Artifact was compared in each image, conducted Gross Evalution, and measured changes of SUVmax. Results For image obtained through the CTAC Shift correction method through WBS with Artifact, 12~56%, Q static scan image showed 17~54% of change rate and Additional Scan showed -27~46% of change rate. In Blind Test, the CTAC Shift correction image showed the highest point with 4 points, Q static scan image showed 3.5 points, and Additional scan image showed 3.4 points. The standardized WBS scan through Oneway ANOVA and three types of Scan method showed significant difference(p<0.05), and did not show significant difference between the three Scan methods(p>0.05). However, the three Scan methods showed significant difference in Blind test. Conclusion Additional scan and Q static scan require more time than the CTAC Shift correction method, there is concern about excessive exposure to patients by CT rescan and Q static scan is difficult to apply on patients with inconsistent respiration or irregular respiration cycle due to pain. For CTAC Shift correction method, limited correction is possible and the range is limited as well. It is considered as a useful method of improving diagnostic value when hospitals use the system appropriately and develop various advantageous factors of each method.

  • PDF

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

The Usefulness Evaluation of Radiation Shielding Devices in PET Scan Procedures (PET 검사 프러시저별 방사선 차폐기구의 유용성 평가)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Jeong, Yo-Cheon;Kim, Sang-Wook;Seo, Il-Teak;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 2010
  • Purpose: he use of PET scanners and the number of patient in Korea have been increased for recent several years dramatically. For this reason, technologists have more possibilities to be exposed to the radiation. The hospitals using PET scanners should make an effort to reduce the radiation exposure dose. The purpose of this study was to evaluate the radiation exposure does when using radiation shielding devices. The evaluation was performed through questionnaire survey and experiment. Materials and Methods: First, the technologists who had experience working in PET center in 2008-2009 were surveyed with questionnaire and TLD Figures, personal opinion of utilization of radiation shielding devices are analyzed. Second, we measured the shielding rate of shielding devices which have been using in PET study procedures. We divided the procedures into four steps; distribution, moving, injection of $^{18}F$-FDG and patient setup. Results: First, the results of this survey, using of L-block+Syringe shield, L-block, Syringe shield, No shield during the injection, were each 58.5%, 20%, 9%, 12.3%. The TLD values according to utilization of radiation shield, using both L-block+Syringe Shield and L-block showed the lower TLD values, and Syringe shield only or No shield showed the higher TLD values. Second, the results of experiments according to PET study procedures measured the shielding rates as follows. The shielding rates during the distribution using L-block, L-block+Apron shield were measured 97.4%, 97.7%. The shielding rates during the $^{18}F$-FDG delivery to the injection room using mobile Syringe shield, Syringe holder, Syringe shield carrier were each 81.7%, 98.9%, 99.7%. The shielding rates during the injection using Syringe shield, L-block, L-block+Syringe shield were measured each 51.9%, 98.3%, 98.7%. The shielding rates of Apron were measured in each 30, 60, 90, 120, 150 cm distance. The measurement were each 16.9%, 14.2%, 16.6%, 17.1%, 18.1%, 18.6%. Conclusion: The most effective method for radiation shielding is to using L-block during the $^{18}F$-FDG distribution and Syringe shield carrier during in moving $^{18}F$-FDG. For the $^{18}F$-FDG injection, L-block+Syringe shield have to be used. The shielding effect of Apron has shown average 16.4%. According to the survey of questionnaire, the operators recognized well risk of the radiation exposure but, tended ignore in working. The radiation dose according to recognition of radiation exposure risk was not relevant. but radiation dose according to utilization of radiation shield lower the more use it. The main reason of no use of shielding devices is cumbersome, 55% of the respondents answered. I'm sure, by use of radiation shield in all PET procedure, radiation exposure will be reduced considerably.

  • PDF

Aspect of the chief of state guard EMP (Electro Magnetic Pulse) protection system for the consideration (국가원수 경호적 측면에서의 EMP(Electro Magnetic Pulse) 방호 시스템에 대한 고찰)

  • Jung, Joo-Sub
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.37-66
    • /
    • 2014
  • In recent years, with the development of computers and electronics, electronics and communication technology in a growing and each part is dependent on the cross-referencing makes all electronic equipment is obsolete due to direct or indirect damage EMP. Korea and the impending standoff North Korea has a considerable level of technologies related to the EMP, EMP weapons you already have or in a few years, the development of EMP weapons will complete. North Korea launched a long-range missile and conducted a nuclear test on several occasions immediately after, when I saw the high-altitude nuclear blackmail has been strengthening the outright offensive nuclear EMP attacks at any time and practical significance for the EMP will need offensive skills would improve. At this point you can predict the damage situation of Korea's security reality that satisfy the need, more than anything else to build a protective system of the EMP. The scale of the damage that unforeseen but significant military damage and socio-economic damage and fatalities when I looked into the situation which started out as a satellite communications systems and equipment to attack military and security systems and transportation, finance, national emergency system, such as the damage elsewhere. In General, there is no direct casualties reported, but EMP medical devices that rely on lethal damage to people who can show up. In addition, the State power system failure due to a power supply interruption would not have thought the damage would bring State highly dependent on domestic power generation of nuclear plants is a serious nuclear power plant accident in the event of a blackout phenomenon can lead to the plant's internal problems should see a forecast. First of all, a special expert Committee of the EMP, the demand for protective facilities and equipment and conduct an investigation, he takes fits into your budget is under strict criteria by configuring the contractors should be sifting through. He then created the Agency for verification of performance EMP protection after you have verified the performance of maintenance, maintenance, safety and security management, design and construction company organized and systematic process Guard facilities or secret communications equipment and perfect for the EMP, such as protective equipment maneuver system should take.

  • PDF

MR-based Partial Volume Correction Using Hoffman Brain Phantom Data and Clinical Application (자기공명영상을 이용한 양전자방출단층촬영의 부분용적효과 보정 및 임상적용)

  • 김동현;이상호;정해조;윤미진;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.203-210
    • /
    • 2003
  • PET (positron emission tomography) permits the investigation of physiological and biochemical processes in vivo. The accuracy of quantifying PET data is affected by its finite spatial resolution, which causes partial volume effects. In this study, we developed a method for partial volume correction using Hoffman phantom PET and MR data, and applied various FWHM (full width at half maximum) levels. We also applied this method to PET images of normal controls and tested for the possibility of clinical application. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices. The gray matter and white matter regions were then segmented into binary images. Each binary image was convolved by 4, 8, 12, 16 mm FWHM levels. These convolved images of gray and white matter were merged corresponding to the same level of FWHM. The original PET images were then divided by the convolved binary images voxel-by-voxel. These corrected PET images were multiplied by binary images. The corrected PET images were evaluated by analyzing regions of interests, which were drawn on the gray and white matter regions of the original MR image slices. We calculated the ratio of white to gray matter. We also applied this method to the PET images of normal controls. On analyzing the corrected PET images of Hoffman phantom, the ratios of the corrected images increased more than that of the uncorrected images. With the normal controls, the ratio of the corrected images increased more than that of the uncorrected images. The ratio increase of the corrected PET images was lower than that of the corrected phantom PET images. In conclusion, the method developed for partial volume correction in PET data may be clinically applied, although further study may be required for optimal correction.

  • PDF

Fortschritte in der Diagnostik von $Eisenstoffwechselst\ddot{o}rungen$ (철대사장애(鐵代謝障碍)의 진단(診斷)에 관(關)한 최근동향(最近勳向))

  • Keiderling, Walter
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 1970
  • 철대사(鐵代謝)에 관(關)한 연구(硏究)는 과거(過去) 30년(年)동안 새로운 검사방법(檢査方法)의 도입(導入)으로 눈부신 발전(發展)을이룩하였다. 1937년(年) Heilmeyer 등(等)에 의(依)하여 Ortho-phenanthrolin방법(方法)의 개발(開發)로 저색소성빈혈(低色素性貧血)의 원인(原因)이 구명(究明)되고 또한 이에 대(對)한 치료(治療)의 원칙(原則)이 세워졌다. 그 후 심(甚)한 감염(感染)이나 악성종양(惡性腫瘍)을 가진 환자(患者)者에서 관찰(觀察)되는 빈혈(貧血)에 대(對)해서 하나의 가설(假說)을 세워 이를 설명(說明)하려 하였는데 이는 곧 혈장(血漿)으로부터 철분(鐵分)이 신속(迅速)히 소실(消失)되어 망내계(網內系)나 병변(病變)이 있는 국소부위(局所部位)에 주(主)로 모여 들어 특수(特殊)한 방어기능(防禦機能)을 발휘(發揮)한다는것으로 연자(演者)는 방사성동위원소(放射性同位元素)를 이용(利用)하여 이 가설(假說)을 증명(證明)하였으며 이 연구(硏究)에는 또한 이문호교수(李文鎬敎授)가 Freiburg대학(大學) 유학중(留學中) 참여(參與)한 바 있다. 철대사(鐵代謝)를 파악(把握)하기 위(爲)해서 $^{59}Fe$가 흔히 사용(使用)되는데 이러한 방사성동위원소(放射性同位元素)를 이용(利用)함으로서 다음 사항(事項)들을 관찰(觀察)할 수 있었다. 즉(卽) 1. 소화장기(消化臟器)로 부터의 철흡수(鐵吸收) 2. 혈장(血漿)에서의 철(鐵)의 소실속도(消失速度) 3. 혈장내(血漿內)에서의 철교체율(鐵交替率) 4. 적혈구(赤血球)의 철이용(鐵利用) 5. 생체내(生體內)의 철분포(鐵分布) 6. 철배설(鐵排泄)의 정량적(定量的) 분석(分析) 또한 근년(近年)에는 특수(特殊)한 기능(機能)을 발휘(發揮)할 수 있는 동위원소(同位元素)를 이용(利用)하여 철흡수(鐵吸收) 및 대사이외(代謝以外)에도 적혈구(赤血球)의 수명(壽命)과 혈액량등(血液量等)을 측정(測定)하게 되었다. 경구적(經口的)으로 투여(投與)된 철(鐵)은 대부분(大部分) 십이지장(十二指腸)의 상부(上部)에서 흡수(吸收)되고 무기철(無機鐵)이 보다 쉽게 흡수(吸收)되어 가(價)의 상태(狀態)로 된다. 혈장(血漿)에서는 transferrin에 의(依)해서 철(鐵)이 운반(運搬)된다. 혈장철(血漿鐵)의 대부분(大部分)은 혈색소분해(血色素分解)에서 유래(由來)되며 이는 다시 혈색소(血色素)의 재생(再生)에 이용(利用)되는데 혈장내(血漿內) 철교체율(鐵交替率)은 방사성철(放射性鐵)을 이용(利用)하여 측정(測定)할수 있다 이와같이 방사성철(放射性鐵)을 이용(利用)하여 철대사과정(鐵代謝過程)을 숙지(熟知)함으르서 임상(臨床)에 응용(應用)하기에 이르렀으며 다음과 같은 질환(疾患)의 진단(診斷)에 특(特)히 큰 도움을 준다. A. 진성철결핍증(眞性鐵缺乏症) : 혁색소철(血色素鐵) 및 저장철(貯藏鐵)을 포함(包含)한 생체내(生體內) 전철분(全鐵分)의 부족(不足)된 상태(狀態)로서 실혈(朱血)에 의(依)한 것이 대부분(大部分)이다. 이 경우 철흡수(鐵吸收)는 증가(增加), 혈장철치(血漿鐵値)는 저하(低下), 철소실속도(鐵消失速度)는 증가(增加)되며 혈장철(血漿鐵) 교체율(交替率)은 항진(亢進) 혹(或)은 정상(正常)이다. B. 심(甚)한 염증성(炎症性) 질환(疾患) : 이 경우에도 혈장철치(血漿鐵値)의 저하(低下), 소실속도(消失速度)의 증가(增加), 교체율(交替率)은 정상(正常)보다 4배(倍)까지 증가(增加)할 수 있다. 골수(骨髓)에서 보다는 간(肝), 비(脾)와 같은 망내계(網內系)에 방사성철(放射性鐵)이 집결(集結)되는 것으로 보아 혈색소철(血色素鐵)보다는 저장철(貯藏鐵)이 관여(關與)되는 것이다. C. 원발성(原發性) 혈색소증(血色素症)(Idiopathic hemochromatosis) : 혈장철(血漿鐵)의 증가(增加)가 현저(顯著)하며 transferrin 농도(濃度)는 정상(正常)보다 낮으나 거의 대부분(大部分)의 철분(鐵分)으로 포화(飽和)된다. 철흡수(鐵吸收)는 증가(增加)되고 철소실속도(鐵消失速度)는 감소(減少) 되어 있으나 교체율(交替率)은 항진(亢進)되어 있다. 혈장철(血漿鐵)은 간(肝), 비(脾) 등(等)의 기관(器管)으로 저장집결(貯藏集結)되어 철저류(鐵貯溜)가 증대(增大)되므로 철이용증((鐵利用症)은 저하(低下)된다. D. 선천성(先天性) 무(無)$\ulcorner$트란스헤 린$\lrcorner$증(症)(Congenital atransferrinemia) : 방사성철(放射性鐵)을 이용(利用)한 진단방법(診斷方法)으로 Freiburg에서 7세(歲)의 소녀(少女)에서 발견(發見)한 증례(症例)인데 간(肝), 비(脾), 심(心)의 비대(肥大)가 임상적(臨床的)으로 인지(認知)되었고 중증(重症)의 철결핍상(鐵缺乏狀)을 검출(檢出)할 수 있었다. 철흡수율(鐵吸收率)의 상승(上昇), 혈장철치(血裝鐵値)의 감소(減少), 혈장철소실속도(血漿鐵消失速度)의 증가(增加), 혈장철교체율(血漿鐵交替率)의 상승(上昇) 및 적혈구(赤血球)에서의 철분이용율(鐵分利用率)의 저하(低下)를 ferrokinetic study에서 알 수 있었고 간(肝)에서 고도(高度)의 방사능(放射能)이 검출(檢出)되는 반면(反面), 비(脾)에서는 극소(極小), 골수(骨髓)에는 전(全)혀 방사능(放射能)이 들어가 있지 않았다. 이 증례(症例)와 같이 transferrin이 없으면 철분(鐵分)은 쉽게 조직(組織)으로 들어가 hemosiderin으로 저장(貯藏)되고 골수(骨髓)는 고도(高度)의 철결핍증(鐵缺乏症)을 나타내어 기관철침착증(器管鐵沈着症)과 철결핍성빈혈(鐵缺乏性貧血)이 동시(同時)에 나타나게 된다. 철대사장애면(鐵代謝障碍面)으로 보아 많은 미해결점(未解決點)이 남아 있으며 앞으로 자라나는 젊은 학도(學徒)들이 구명(究明)할 문제(間題)라고 믿는다.

  • PDF