• Title/Summary/Keyword: 합류식하수관거 월류수

Search Result 33, Processing Time 0.022 seconds

A Water Quality Modeling Study of Chunggye Stream during Combined Sewer OverFlow Period (합류식 하수관거 월류수 유입 기간 동안에 나타나는 청계천 수질 변화 모델 연구)

  • Yi, Hye-Suk;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1340-1346
    • /
    • 2005
  • A water quality modeling study was performed for Chunggye stream during combined sewer overflow(CSO) period, utilizing the diagnostic system for water management in small watershed, CREEK-1(Cyber River for Environment and Economy in Korea). This system integrated geogaphic information system, data base, landscape ecological model(FRAGSTATS), watershed model(SWMM), water quality model (WASP5), and computer graphic. In this study, the watershed model and water quality model were extensively utilized so as to simulate water qualities and flow in Chunggye stream during wet periods. The Chunggye stream watershed was divided into 18 sub-basins in the watershed model and the stream reach into 11 segments in the water quality model. The watershed model was validated against field measurements of BOD, TN, TP, and flow at the downstream location, where the model results showed a reasonable agreement with the field measurements at all parameters. From this study, it was shown that the stream water quality would change along with elapsed time from rainfall start as well as rainfall intensity. The model results indicated that the water quality would significantly upgrade due to the first flush and high sewage ratio of CSO at the beginning of rainfall event, but become degraded along with the runoff increase due to dilution effect.

Determination of Interception Flow by Pollution Load Budget Analysis in Combined Sewer Watershed - Analysis of Pollution Load Budget in Watershed - (오염부하 물질수지 분석을 통한 합류식 하수관거 적정 차집용량 결정(I) -오염부하 물질수지 분석-)

  • Lee, Doojin;Kim, Juwhan;Woo, Hyungmin;Ahn, Hyowon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.547-556
    • /
    • 2005
  • The objective of this study is to obtain adequate intercepting flow during wet weather conditions in combined sewer system. Two study sites are selected under considering different population density, one is developed area with heavy urbanization. Another is recently developing area. In the analysis of field investigation, SS was most significant in initial flushing effects compared with other factors and showed the result with the order of COD, TP, TN. As compared with event mean concentration(EMC) of runoff, BOD, TN and TP showed high concentrations in wide area with relatively large population density. It is by the reason that much pollution load was discharged to receiving water from urbanized area during wet period. According to results of storm-water modeling, 53% of total COD and 52% of total SS pollution load were discharged to receiving water by overflow than intercepting capacity in middle population density site. Also, in the urbanized area, pollution load was discharged to receiving water by 49% of total COD and 77% of total SS. These results can be applied to setup for pollution load flow(budget) generation, collection, treatment and discharging in order to obtain adequate intercepting flow.

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.

Addition of Coagulants for Phosphorus Removal from Combined Sewer Overflows (CSOs) (합류식 하수관거 월류수의 인제거를 위한 응집제 투여)

  • Son, Sang-Mi;Jutidamrongphan, Warangkana;Park, Ki-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.295-302
    • /
    • 2012
  • The coagulation of combined sewer overflows ($CSO_{s}$) was investigated by jar-testing with several commercial coagulants. $CSO_{s}$ sample showed different characteristics of coagulation from secondary wastewater with three common coagulants, aluminum sulfate, ferric chloride and polyaluminum chloride (PACl). Jar-tests showed that relatively wide range of optimal SS and T-P removal yielded with alum and ferric chloride compared with cationic polymers, though efficient SS and T-P removal can be achieved with all three coagulants. The decrease of pH was caused by the increase in dosage of aluminum sulfate, ferric chloride and PACl as coagulants. The pH was changed from 7.0 to 4.7 with the dosages of ferric chloride 25 mL/L. Aluminum sulfate revealed pH of 5.0 and PACl was highest pH of 5.4 after dosing of coagulants. The optimal pH to treat $CSO_{s}$ with aluminum sulfate were 6-6.5; with PACl 6-7, and with ferric chloride higher than 7.

Analysis of Storm Water Run-off Characteristics to Evaluate the Intercepted Volume of CSOs during Wet Weather (강우시 합류식 하수관거의 월류수 차집용량 산정을 위한 유출특성 분석)

  • Choi, Sung-Hyun;Choi, Seung-Chol;Kim, Byoung-Ug;Rim, Jay-Myoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.320-330
    • /
    • 2004
  • Most of domestic city is served combined sewer system among various sewer system like as separate sanitary, combined sewer system and storm sewers. During the wet weather, sewer and rainfall have been overflowed because it is over capacity of the combined sewer system; that is called combined sewer overflows(CSOs) This research was carried out to investigate runoff characteristics of combined sewer and to evaluate the effective CSOs volume in Hong-Chun gun. During wet weather, SS load of first rainfall at H-1, H-2, and H-3 were 600kg/event, 370kg/event, and 289kg/event, respectively. 55 load of second rainfall were 216kg/event, 113kg/event, and 37.2kg/event. When the first rainfall, event mean concentrations(EMCs) at each site were 702mg/L, 816mgjL and 861.5mg/L. The second rainfall's event mean concentrations(EMCs) were 99.9gm/L, 161.9mg/L, 103.6mg/L. Rrst flush coefficient b at each site were 0.237,0.166, and 0.151. When the first rainfall, the flow containing 80% of pollutant mass of CSOs at each site were 0.55, 0.23, 0.48 in first rainfall, respectively. The case of second rainfall were 0.79, 0.83, 0.81. Most of all, characteristics of rainfall like as analysis of first-flush, CSOs volume, pollutant loadings is investigated to decide intercepted volume for control of CSOs.

Optimal Operating Condition of Vortex Separator for Combined Sewer Overflows Treatment (합류식 하수관거 월류수 처리를 위한 와류형 분리장치의 최적 운전조건)

  • Han, Jung-kyun;Joo, Jae-young;Lee, Bum-joon;Na, Ji-hun;Park, Chul-hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.557-564
    • /
    • 2009
  • A combined sewer system can quickly drain both storm water and sewage, improve the living environment and resolve flood measures. A combined sewer system is much superior to separate sewer system in reduction of the non-point source pollutant load. However, during rainfall. it is impossible in time, space and economic terms to cope with the entire volume of storm water. A sewage system that exceeds the capacity of the sewer facilities drain into the river mixed with storm-water. In addition, high concentration of CSOs by first-flush increase pollution load and reduce treatment efficiency in sewage treatment plant. The aim of this study was to develope a processing unit for the removal of high CSOs concentrations in relation to water quality during rainfall events in a combined sewer. The most suitable operational design for processing facilities under various conditions was also determined. With a designed discharge of 19.89 m/min, the removal efficiency was good, without excessive overflow, but it was less effective in relation to underflow, and decreased with decreasing particle size and specific gravity. It was necessary to lessen radius of vortex separator for increasing inlet velocity in optimum range for efficient performance, and removal efficiency was considered to high because of rotation increases through enlargement of comparing height of vortex separator in diameter. By distribution of influent particle size, the actual turbulent flow and experimental results was a little different from the theoretical removal efficiency due to turbulent effect in device.

Analysis of the Effect of Bio-Retention Cells to Improve Water Cycle and Water Quality in Urban Streams (도시하천의 물순환 및 수질 개선을 위한 생태저류지의 효과분석)

  • Kim, Kyungmin;Choi, Jeonghyeon;Kim, Suhyeon;Kang, Lim-Seok;Shin, Hyunsuk;Kim, Sangdan
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.224-235
    • /
    • 2019
  • Rapid urbanization poses three major problems in urban streams. The first problem is the reduction of soil wetting from rainfall as the impervious area increases. Decrease in soil wetting causes serious distortion in the water cycle of urban streams. The second problem is the increase of non-point sources pollutants by urban land use, and the third problem is the combined sewer overflows in the old city center. Increased non-point sources pollutants and combined sewer overflows are associated with water cycle distortion, which increases water pollution in urban streams. In this study, EPA SWMM was constructed for the Busan Oncheon-stream watershed in order to suggest solutions for these three problems, and the bio-retention cells installation project was planned by benchmarking the actual projects in New York City. Water cycle improvement and reduction of non-point sources pollutants and combined sewer overflows for each project scenario were analyzed together with required budgets.

Analysis of Hydrodynamic Separators for Combined Sewer Overflows and Stromwater Runoff Control (합류식 하수관거 월류수 및 우수관거 유출수의 수리동력학적 오염부하저감장치의 분석)

  • Lee, Soo Young;Oh, Ji Hyun;Ryu, Seong Ho;Kwon, Bong Ki;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.117-124
    • /
    • 2005
  • Appropriate removal of pollutants from combined sewer overflows(CSOs) and stormwater runoff is of primary concern to watershed managers trying to meet water quality standards even under a wet weather condition. Harmful substances associated with particles besides TSS and BOD are subjected to removal prior to discharge into the natural waters. Effectiveness of five major hydrodynamic separation technologies, Vortechs, Downstream Defender including Storm King for CSOs control, CDS, Stormceptor, and IHS, were evaluated in this study. There is not sufficient information for accurate evaluation of the removal efficiency for the pollutants from the stormwater runoff and CSOs. Based upon limited engineering data, however, all technologies were found to be effective in separation of heavy particles and floating solids. Technologies utilizing screens seem to have advantage in the treatment capacity than the other technologies relied fully on hydrodynamic behavior. The IHS system seems to have a strong potential in application for control of CSOs because of unique hydrodynamic behavior as well as a flexibility in opening size of the screens. Size of the particulate matter in the CSOs and stormwater runoff is found to be the most important parameter in selection of the type of the hydrodynamic separators. There exists an upper limit in the solids removal efficiency of a hydrodynamic separator, which is strongly dependent upon the particle size distribution of the CSOs and stormwater runoff.

Operation Strategy for a Multi-functional Storage Facility (하수저류시설 운영 전략 연구)

  • Yun, So-Young;Lim, Yoon-Dae;Oh, Jei-ll
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.959-970
    • /
    • 2011
  • The frequent occurrence of sewer flooding and the intermittent discharge of non-point pollutions into the receiving water body are emerging issues recently due to the climate change and urbanization. These problems might be solved by introducing a multifunctional storage facility. Unlike a single-purpose storage facility, a multi-purpose storage facility should be operated at an instant to meet for flood prevention, reduction of non-point pollution and/or rainwater reuse. Considering various operational combinations it is suggested that prevention of sewer flooding coupled with reduction of non-point pollution is the most effective operational strategy for a multi-functional storage facility.

Feasibility Study on Installing a Multi-functional Storage Facility (하수저류시설 타당성 분석 연구)

  • Ryu, Jae-Na;Oh, Jei-ll;Lee, Kyoung-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.935-947
    • /
    • 2011
  • In the era of climate change, the feasibility of a 'multi-functional storage facility' was evaluated in terms of various key performance indices such as flooding prevention effects, urban pollution reduction effects, and rainwater harvesting effects. As a result, the Korea Ministry of Environment introduced a new concept of 'multi-functional storage facility' for sewer flooding prevention and urban non-point pollution reduction. Prior to introducing these infrastructure (a large underground storage facility), the more details were needed to be examined carefully in all of technical aspects of construction and management. It was also well known that the validity of installation of 'multi-functional storage facility' was sometimes weakened because of a low B/C ratio.