• Title/Summary/Keyword: 합금

Search Result 8,212, Processing Time 0.034 seconds

Non-Destructive Evaluation of Microstructure of SiC/AC8A Composite Material by Ultrasonic Measurement (초음파를 이용한 비파괴방법에 의한 SiC/AC8A금속 복합재료의 미시조직 평가)

  • Park, Y.C.;Yun, D.P.;Lee, G.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.4
    • /
    • pp.225-233
    • /
    • 1997
  • This study is performed to establish a non-destructive evaluation method for metal matrix composite using ultrasonic technique. The specimen is made of SiC/AC8A metal matrix composite by squeeze-casting method. Three kinds or reinforced particles are prepared as 4.86, 8.09 and $11.44{\mu}m$ to investigate the effect of size on the mechanical and ultrasonic properties of metal matrix composite. In addition, four different volume fractions (14, 22.5, 27.5, 35%) of reinforced particles are prepared per each size to examine the effect of volume fraction on the ultrasonic properties. From this specimen, the availability and precision of measurement of Young's modulus are examined and the evaluation method for microstructure of metar matrix composite using the speed of sound and attenuation factor is also reviewed. The results show that the Young's modulus measured by ultrasonic method is as effective as that measured by mechanical method. It is also known that the size and volume fraction of reinforced fiber are precisely evaluated using the speed of sound and attenuation factor.

  • PDF

Relative Evaluation for Biocompatibility of Pure Titanium and Titanium Alloys using Histological and Enzymatic Methods (조직학과 효소활성 방법을 이용한 순 타이타늄과 타이타늄 합금의 상대적인 생체적합성 평가)

  • Yeom, Dong-Sun;Kim, Byung-Il;Lee, Yu-Mi;Lee, Eun-Jung;Yee, Sung-Tae;Seong, Chi-Nam;Seo, Kwon-Il;Cho, Hyun-Wook
    • Toxicological Research
    • /
    • v.23 no.4
    • /
    • pp.331-339
    • /
    • 2007
  • Titanium or titanium alloy is a widely used implant material according to its certified biocompatibility, sufficient strength and ready availability. The purpose of this study was to evaluate the relative biocompatibility of titanium and titanium alloy specimens (Ti-29Nb-13Ta, TiNb and Ti-6Al-4V, Ti64) using in vivo and in vitro methods. For in vivo experiment, the specimens were implanted in the abdominal subcutaneous region of female mice for 2 and 4 weeks. The reaction of connective tissue to specimens was evaluated histologically. The specimens were encapsulated by fibrous connective tissue consisting of fibroblast, fibrocyte and other cells including neutrophil, macrophage, giant multinucleated cell and unidentified cells. Some newly formed blood vessels were located in the fibrous capsule surrounding the implant. Cell types and the thickness of fibrous capsules were examined quantitatively. Most of cell types located in the fibrous capsule were fibroblasts and fibrocytes. The average thickness of fibrous capsules for the TiNb specimens was much thinner than that of the titanium alloy, Ti64. The thickness of the fibrous capsule around all titanium specimens decreased at 4 weeks compared to 2 weeks post-implantation. The biocompatibility of titanium and titanium alloy specimens were also investigated in in vitro method using alkaline phosphatase from MG-63 cells. Alkaline phosphatase activity of the TiNb specimen showed higher activity than the titanium alloy, Ti64. In conclusion, the TiNb alloy with thin capsule thickness in vivo and high alkaline phosphatase activity in vitro will be of considerable use in biomedical applications.

Side-Wall 공정을 이용한 WNx Self-Align Gate MESFET의 제작 및 특성

  • 문재경;김해천;곽명현;임종원;이재진
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.162-162
    • /
    • 1999
  • 초고주파 집적회로의 핵심소자로 각광을 받고 있는 GaAs MESFET(MEtal-emiconductor)은 게이트 형성 공정이 가장 중요하며, WNx 내화금속을 이용한 planar 게이트 구조의 경우 임계전압(Vth:threshold voltage)의 균일도가 우수할 뿐만 아니라 특히 Side-wall을 이용한 self-align 게이트는 소오스 저항을 줄일 수 있어 고성능의 소자 제작을 가능하게 한다.(1) 본 연구의 핵심이 되는 Side-wall을 형성하기 위하여 PECVD법에 의한 SiOx 박막을 증착하고, 건식식각법을 이용하여 SiOx side-wall을 형성하였다. 이 공정을 이용하여 소오스 저항이 낮고 임계전압의 균일도가 우수한 고성능의 self-aligned gate MESFET을 제작하였다. 3inch GaAs 기판상에 이온주입법에 의한 채널 형성, d.c. 스퍼터링법에 의한 WNx 증착, PECVD법에 의한 SiOx 증착, MERIE(Magnetic Enhanced Reactive Ion Etcing)에 의한 Side-wall 형성, LDD(Lightly Doped Drain)와 N+ 이온주입, 그리고 RTA(Rapid Thermal Annealing)를 사용하여 활성화 공정을 수행하였다. 채널은 40keV, 4312/cm2로, LDD는 50keV, 8e12/cm2로 이온주입하였고, 4000A의 SiOx를 증착한 후 2500A의 Side-wall을 형성하였다. 옴익 접촉은 AuGe/Ni/Au 합금을 이용하였고, 소자의 최종 Passivation은 SiNx 박막을 이용하였다. 제작된 소자의 전기적 특성은 hp4145B parameter analyzer를 이용한 전압-전류 측정을 통하여 평가하였다. Side-wall 형성은 0.3$\mu\textrm{m}$ 이상의 패턴크기에서 수직으로 잘 형성되었고, 본 연궁에서는 게이트 길이가 0.5$\mu\textrm{m}$인 MESFET을 제작하였다. d.c. 특성 측정 결과 Vds=2.0V에서 임계전압은 -0.78V, 트랜스컨덕턴스는 354mS/mm, 그리고 포화전류는 171mA/mm로 평가되었다. 특히 본 연구에서 개발된 트랜지스터의 게이트 전압 변화에 따른 균일한 트랜스 컨덕턴스의 특성은 RF 소자로 사용할 때 마이크로 웨이브의 왜곡특성을 없애주기 때문에 균일한 신호의 전달을 가능하게 한다. 0.5$\mu\textrm{m}$$\times$100$\mu\textrm{m}$ 게이트 MESFET을 이용한 S-parameter 측정과 Curve fitting 으로부터 차단주파수 fT는 40GHz 이상으로 평가되었고, 특히 균일한 트랜스컨덕턴스의 경향과 함께 차단주파수 역시 게이트 바이어스, 즉 소오스-드레스인 전류의 변화에 따라 균일한 값을 보였다. 본 연구에서 개발된 Side-wall 공정은 게이트 길이가 0.3$\mu\textrm{m}$까지 작은 경우에도 사용가능하며, WNx self-align gate MEESFET은 낮은 소오스저항, 균일한 임계전압 특성, 그리고 높고 균일한 트랜스 컨덕턴스 특성으로 HHP(Hend-Held Phone) 및 PCS(Personal communication System)와 같은 이동 통신용 단말기의 MMICs(Monolithic Microwave Integrates Circuits)의 제작에 활용될 것으로 기대된다.

  • PDF

Microelectromechnical system 소자를 위한 박막형 2차 전지용 TEX>$SnO_2$ 음극 박막의 충, 방전 특성 평가

  • 윤영수;전은정;신영화;남상철;조원일
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.50-50
    • /
    • 1999
  • 마이크로 공정을 이용한 초소형 정밀 기계는 공정 기술과 재료 기술의 발전에 의하여 더욱 소형화되고 있으며 특히 기능을 갖는 부분과 이 부분을 제어하는 주변회로의 on-chip화의 요구가 증가되기 시작하였다. 이와 같은 추세에 있어서의 문제점은 초소형 정밀기계 부품 소자의 구동을 위한 에너지원의 개발이다. 즉, 소자의 크기가 작아진 것에 부합되는 초소형의 전지가 필요하게 된 것이다. 따라서 보다 완전한 초소형 정밀 기계 및 마이크로 소자의 구현을 위하여 마이크로 소자와 혼성 (Hybrid) 되어 이용될 수 있는 고성능 및 초소형의 전지의 개발이 필수적이다. 초소형 전지의 구현을 위하여 Li계의 2차 전지를 선택하여 이를 박막화하고 반도체 공정을 도입할 수 있다. 이러한 전지를 박막형 2차 전지 또는 박막형 마이크로 전지(thin film Secondary Battery : TFSB or Thin Film Micro-Battery : TFMB)라 하며 이러한 2차 전지는 일반적인 벌크 전지와 동일하게 cathode/Electolyte/Anode의 구조를 갖는다. 박막의 특성상 전해질은 고상의 물질을 사용하는 것이 벌크형 2차 전지와 다른 점이다. TFSB의 성능은 주로 cathode에 의하여 결정되며 지금까지 많은 cathode 물질에 대한 연구 보고가 발표되고 있다. 반도체 공정을 이용한 TFMB의 제작시 무엇보다 중요한 점은 우수한 고상 전해질 및 anode 물질의 선택에 있다. 최근에 2차 전지를 위한 carbon계 anode를 대체할 수 있는 SnO에 대한 보고가 있는데 이는 한 개의 Sn 원자당 2개 이사의 Li가 반응하여 높은 용량을 갖는 전지의 제작이 가능하기 때문이다. Sno2의 anode는 매우 높은 충전용량을 갖는데 첫 번째 방전시에 Li2O를 생성하여 비가역적 반응을 나타내고 계속되는 충방전 동안 Li-Sn 합금이 생성되어 2차전지의 가역적 반응을 가능하게 한다. SnO2 는 대기중에서 Li 금속보다 안정하기 때문에 전지의 제작 공정 및 사용 면에서 매우 우수한 물질이지만 아직까지 SnO2 구조적 특성과 전지의 충, 방전 특성에 대한 관계의 규명을 위한 정확한 정설은 제시되고 있지 못하다. 본 연구에서는 TFSB anode 물질로써 SnOx박막을 상온에서 여러 전도성 콜렉터 위에 증착하여 그 충, 방전 특성을 보고하였다. 증착된 SnOx박막의 표면은 SEM, AFM으로 분석하였으며 구조의 분석은 XR와 Auger electron spectroscope로 하였다. 충, 방전 특성을 분석하기 위하여 리늄 foil을 대극과 참조 전극으로 하여 EC:DMC=1:1, 1M LiPF6 액체 전해질을 사용한 Half-Cell를 구성하여 100회 이상의 정전류 충, 방전 시험을 행하였다. Half-Cell test 결과 박막의 구조, 콜렉터의 종류 및 Sn/O비에 따라 서로 다른 충, 방전 거동을 나타내었다.

  • PDF

$CH_4-H_2-N_2 $ 기체계에서 MW-PACVD를 이용한 결정상의 합성

  • 김도근;백영준;성태연
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.54-54
    • /
    • 1999
  • 다이아몬드 합성시 질소 첨가는 Cn 화합물의 합성가능성을 비롯하여 다이아몬드의 질소 도핑, 성장 속도 및 결정성 변화 등 다양한 관점에서 중요한 의미를 가지고 있다. 본 연구에서는 다이아몬드의 일반적인 합성조건에서 질소를 첨가하여 합성된 막의 형상 및 상 변화에 대해 고찰하였다. 막은 다이아몬드 전처리시킨 Si 기판위에 microwave plasma CVD 장치를 이용하여 합성하였다. 유입되는 혼합가스(CH4+H2+N2)에서 N2 첨가량을 0-95%까지 변화시켰다. 이때 CH4 농도는 5%로 고정하였고, 합성온도는 90$0^{\circ}C$-115$0^{\circ}C$까지 변화시켰다. 이와 같이 합성된 막의 표면조직 및 성장 두께를 측정하기 위해 주사전자현미경을 이용하였다. 상의 분석은 Raman, XRD 및 TEM 분석을 이용하였으며, 조성분석을 위해 XPS 및 AES를 사용하였다. 질소 첨가량에 따라 합성된 막은 첨가하지 않은 경우에 다이아몬드 결정에서 시작하여 질소첨가에 따라 결정면이 깨지는 것으로 나타났다. 그러나 30%, 45%의 경우는 다시 결정면이 나타났다. 다량의 질소가 첨가되었을 때, 다시 결정면을 보이는 다이아몬드가 합성된 것은 매우 흥미로운 결과이다. 한편 질소와 메탄만의 기체하에서는 다시 결정면이 관찰되지 않았다. 이들 상의 구조는 XRD 및 TED 분석을 통해 모두 다이아몬드로 확인되었다. 기체내의 질소의 첨가에 관계없이 고상내에 질소는 확인되지 않았다. 따라서 이방법에 의한 CN 화합물의 합성은 힘든 것으로 보여진다. 이들 실험 결과를 근거로 온도 및 조성에 따른 기체의 열역학적 계산을 통하여 합성거동과의 연관성을 검토하였다. anode는 매우 높은 충전용량을 갖는데 첫 번째 방전시에 Li2O를 생성하여 비가역적 반응을 나타내고 계속되는 충방전 동안 Li-Sn 합금이 생성되어 2차전지의 가역적 반응을 가능하게 한다. SnO2 는 대기중에서 Li 금속보다 안정하기 때문에 전지의 제작 공정 및 사용 면에서 매우 우수한 물질이지만 아직까지 SnO2 구조적 특성과 전지의 충, 방전 특성에 대한 관계의 규명을 위한 정확한 정설은 제시되고 있지 못하다. 본 연구에서는 TFSB anode 물질로써 SnOx박막을 상온에서 여러 전도성 콜렉터 위에 증착하여 그 충, 방전 특성을 보고하였다. 증착된 SnOx박막의 표면은 SEM, AFM으로 분석하였으며 구조의 분석은 XR와 Auger electron spectroscope로 하였다. 충, 방전 특성을 분석하기 위하여 리늄 foil을 대극과 참조 전극으로 하여 EC:DMC=1:1, 1M LiPF6 액체 전해질을 사용한 Half-Cell를 구성하여 100회 이상의 정전류 충, 방전 시험을 행하였다. Half-Cell test 결과 박막의 구조, 콜렉터의 종류 및 Sn/O비에 따라 서로 다른 충, 방전 거동을 나타내었다.다. 거의 없었다. 5mTorr 일 때가 가장 좋았다.수 있음을 알 수 있었다. 그러므로, RNA바이러스의 하나인 BVDV의 viral replicon을 이용하여 다양한 종류의 포유동물 세포에 유전자 발현벡터로써 사용할 수 있음으로 post-genomics시대에 다양한 종류의 단백질 기능연구에 맡은 도움이 되리라 기대한다.다양한 기능을 가진 신소재 제조에 있다. 또한 경제적인 측면에서도 고부가 가치의 제품 개발에 따른 새로운 수요 창출과 수익률 향상, 기존의 기능성 안료를 나노(na

  • PDF

Quality Evaluation of Dried Red Pepper After Copper Plate Contact (구리표면 접촉에 의한 건조 고춧가루의 특성 평가)

  • Oh, Yeong Ji;Park, Sun Young;Song, Eiseul;Kang, Smee;Hong, Jungil
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.2
    • /
    • pp.177-182
    • /
    • 2020
  • Copper possesses antimicrobial properties against certain bacteria and fungi. In this study, changes in microbial population, color and the antioxidant properties of dried red pepper powder (RPP) by contact with the surface of a copper plate were investigated. Lightness of RPP increased after treatment on the copper plate for 2 h at 55℃. The numbers of total aerobic mesophilic bacteria in RPP increased by 0.61 and 0.50 log on the surface of stainless steel and copper plates during 24 h at 37℃, respectively. The population of yeast and mold was reduced by 90% in the RPP treated on both copper and stainless steel plates under the same condition. Yeast and mold were significantly reduced on the copper plate during 2 h at 55℃. Scavenging activities of RPP treated on the copper plate for 24 h at 37℃ against DPPH radical were decreased; those for 2 h at 55℃ against ABTS radical were rather enhanced. The results suggest that copper might be applied in the processing and storage equipment in relation to RPP products for antimicrobial purposes.

Wettability Evaluation of Sn-0.3Ag-0.7Cu Solder Alloy with Different Flux Activity and Indium Addition (플럭스 활성도 및 In 첨가에 따른 Sn-0.3Ag-0.7Cu 솔더 조성의 젖음 특성 변화)

  • Yu, A-Mi;Kim, Jun-Ki;Kim, Mok-Soon;Hyun, Chang-Yong;Lee, Jong-Hyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.4
    • /
    • pp.51-57
    • /
    • 2008
  • In this paper, wetting and interfacial reaction properties for low Ag containing Sn-Ag-Cu Pb-free solder alloy, i.e., Sn-0.3Ag-0.7Cu were investigated and compared with those of Sn-1.0Ag-0.5Cu and Sn-3.0Ag-0.5Cu. Melting behavior and stress-strain curves of some Sn-xAg-xCu alloys were also measured using a differential scanning calorimeter(DSC) and a tensile test machine, respectively. In order to enhance insufficient wetting properties of Sn-0.3Ag-0.7Cu alloy, the improvement of wetting properties were analyzed by applying fluxes containing higher content of halide or indium adding of 0.2wt.% into the solder alloy. It was concluded that the small addition of indium is more effective for the improvement of wettability in low temperature range of $230{\sim}240^{\circ}C$ than applying flux containing higher content of halide.

  • PDF

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

A Study of Ni-resistant bacteria isolated from gingival crevicular fluid on the patients wearing Ni-Cr alloy prosthesis (In terms of molecular biological aspects) (니켈-크롬 합금 보철물 주위 치은열구 내에서 발견된 니켈 내성 균주에 관한 분자생물학적 연구)

  • Chae, Young-Ah;Woo, Yi-Hyung;Choi, Boo-Byung;Choi, Dae-Gyun;Lee, Sung-Bok;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.741-755
    • /
    • 1999
  • As a material of metal-ceramic prosthesis, nickel as a form of Ni-Cr alloy has been used for many dental prostheses in many cases. However, several problems in use of the alloy have been revealed (ex : tissue stimulation, skin allergy, hypersensitivity, cytotoxicity and carcinogenecity). Little is known about nickel with respect to the relationship between Ni-prosthesis and gaining of Ni-resistance in oral microorganisms. The present study was undertaken to check wheather use of Ni-prosthesis leads to occurrence of Ni-resistant microorganisms. So this study may suggest the possible relationships between the oral microorganisms and nickel-resistance in oral environment. Bacteria were isolated from the gingival crevicular fluid on the pateints wearing Ni-Cr prosthesis. The isolated bacteria were tested for their Ni-resistance in nickel containing media at different concentration from 3mM to 110mM. E. coli HB101 was used as control. The Ni-resistant bacteria were isolated and biochemically identified. The Ni-resistant bacteria were tested several bio-chemical, molecular-biological tests. Performed tests were ; measuring the growth curve, antibiotic test, growth ability test in liquid media, isolation of the chromosome and plasmid, digestion of DNA by restriction enzyme, electrophoresis of chromosome and plasmid DNA, identification of Ni-resistant genes by the DNA hybridization. The results were as follows: 1) The bacteria isolated from gingival crevicular fluid on the patients wearing Ni-Cr alloy pros-thesis showed nickel-resistance. 2) The isolated microorganisms grew at nickel containing media of high concentrations (60mM-110mM). 3) Based on the biochemical tests, the isolated microorganisms were identified as Enterococcus faecalis(13 cases), Klebsiella pneumoniae(1 case) and Enterobacter gergeviae(1 case). 4) Enterococcus faecalis expressed not only nickel resistance but also the multi-drug resistance to several antibiotics ; chloramphenicol, kanamicin, streptomycin, lincomycin, clindamycin. However, all strain showed the sensitivity against the tetracycline. 5) DNA hybridization result suggest that there is no homology between the previousely known gene of nickel resistance in Klebsiella pneumoniae and chromosomal DNA of Enterococcus faecalis.

  • PDF

High Energy Resolution Alpha Spectrometer Using a Cryogenic Detector (저온검출기를 이용한 에너지 고 분해능 알파분광 구현)

  • Kim, M.S.;Lee, S.H.;Yoon, W.S.;Jang, Y.S.;Lee, S.J.;Kim, Y.H.;Lee, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.132-137
    • /
    • 2013
  • Cryogenic particle detectors have recently been adopted in radiation detection and measurement because of their high energy resolution. Many of these detectors have demonstrated energy resolutions better than the theoretical limit of semiconductor detectors. We report the development of alpha spectrometer using a micro-fabricated magnetic calorimeter coupled to a large-area particle absorber. A piece of gold foil of $2{\times}2{\times}0.05mm^3$ was glued to the paramagnetic temperature sensor made of sputtered Au:Er film to serve as an absorber for incident alpha particles. We performed experiments with 241Am source at cryogen free adiabatic demagnetization refrigerator (CF-ADR). A high energy resolution of 6.8 keV in FWHM was obtained for 5.5 MeV alpha particles.