• Title/Summary/Keyword: 한국전기안전공사

Search Result 130, Processing Time 0.025 seconds

Development of Embedded based Sea Operation Monitoring System (임베디드 환경의 해상작업 모니터링 시스템 개발)

  • Jung, Sung-Hun;Rhee, Bong-Keun;Yim, Jae-Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.93-97
    • /
    • 2005
  • Sea operation monitoring system is a system for the automatic ship operation that is used on the variety sea operations such as laying optical cables on the sea between the countries, laying cables on the seabed for a remote island, laying pipelines for the natural gas, and so forth. This system processes data which optained through setting up environment and input from several sensors, and display GPS information with ENC data. And this system processes not only data of root file about sea operation, but also realtime information from PDA of client wirelessly connected with AP on wireless LAN, In addition, this system can improve efficiency of the operation as a result of enabling free movement within valid range. This paper design and Implementation Monitoring system from above appropriate to the embedded system, and improve competitive power of ship through prevention of a ship accident, to keep minimizing operation loads and support both the automatic ship operation and the safety voyage.

  • PDF

Case Study on Location of Possible Tension Crack in Rock Slope (암반 비탈면의 인장균열 위치 선정에 관한 사례 연구)

  • Jeon, Byung-Gon;Kim, Jiseong;Kang, Gichun
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.3
    • /
    • pp.5-17
    • /
    • 2021
  • This study aims to investigate the causes and countermeasures for the occurrence of tension cracks in the slope of the rock mass of heavy equipment for road construction. Electric resistivity survey was performed to investigate the expandable tensile crack range. As a result of examining the distribution of soft zones in the rock mass, a low specific resistance zone was found at the bottom of the access road where tensile cracks occurred. It was confirmed that a low resistivity zone was distributed near the top of the excavation slope. Therefore, reinforcements was performed by determining the location of the possible tensile crack as the top of the excavation slope. Two rows of reinforced piles and anchors were proposed as a reinforcement method, and the slope stability analysis showed that the allowable safety factor was satisfied after reinforcements.

Patterns and Characteristics of Corrugated Stainless Steel Tubing for a Yellow Insulation Ring Type by Artificially Deteriorated (인위적으로 열화된 황색절연링형 금속플렉시블호스의 패턴 및 특성)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.1-6
    • /
    • 2018
  • This study is to analyze the characteristics of the yellow insulation ring type of the CSST used for tubing when it is artificially deteriorated and damaged by burning. The CSST for tubing consists of a tube, protective coating, nut, yellow insulation ring, packing, and socket. In addition, it is thought that a yellow insulation ring and rubber packing were used to connect the tube and socket in order to improve the airtightness and insulation performance. The result of the verification of the data acquired from the tests in the 95% confidence interval shows that the Anderson-Darling (AD) and P value were analyzed to be 0.945 and 0.015, respectively. This confirms that the test data of the CSST for tubing is reliable. The analysis of the arithmetic mean of the insulation resistance of a CSST showed that the CSST damaged by burning by a torch, and the one damaged by electrical burning, was $16.7k{\Omega}$ (the greatest relatively) and $208{\Omega}$ (the lowest), respectively, while it was $1.72k{\Omega}$ in the case of a normal product. Therefore, the analysis result of the insulation resistance of the CSST collected from the scene of a fire can be utilized to examine the cause of damage by burning. In addition, it was found that when the maximum current of 97 A was applied to the CSST for about 5 s using a Primary Current Injection Test System (PCITS) the protective film and insulation ring of the CSST has no difference from that of a normal product. However, a part of the metal tube was melted.

A Study on the Safety Grounding for Prevention of Electric Shock Hazard in Construction of Industrial Plant in Maritime Landfill Area (해상 매립 지역 산업 플랜트 건설 시 감전 재해 예방을 위한 안전 접지에 관한 연구)

  • Kim, Hong-Yong;Jang, Ung-Burm
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.305-312
    • /
    • 2017
  • In our society, the advanced, advanced, and information industries have continued to grow and now live in the era of the fourth industrial revolution. As the industry develops, the load of the users has also increased so much that it is deepened by the energy shortage phenomenon and the construction of additional energy facilities is required. Therefore, energy plant construction work is being actively carried out in the coastal area. In particular, it is common to build a plant in the ground by filling the coast with soil in other regions, reflecting the fact that Korea is lacking in the country when constructing power plants, gas and petrochemical plants. Current domestic grounding designs are designed or constructed to suit only the use of grounding resistors based on the electrical equipment design technical standards. However, in the case of a plant facility constructed in the untested buried soil, when the lightning current and the abnormal current are inputted, the facility operator or the user due to the elevation of the ground potential is seriously exposed to the risk of electric shock disaster. In this paper, we analyze the ground resistivity of the landfilled soil and use a computer program (CDEGS) based on KS C IEC 61936-1, We analyze the contact voltage and stratification voltage and propose a grounding design optimized for plant installation.

A Study on Selection of an Overhead Electrical Transmission Line Corridor with Social Conflict (사회적 갈등을 갖는 송전선로 경과지 선정에 관한 연구)

  • Son, Hong-Chul;Moon, Chae-Joo;Kim, Hak-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.577-584
    • /
    • 2021
  • Electrical energy is an essential component in present societies, which is an important basis for our technological society. In the design of new power infrastructure, it is important to consider the psychological aspects of how our culture considers and aspects its development as an integral component of the community environment. The construction of new high voltage overhead transmission lines has become a controversial issue for public policy of government due to social opposition. The members of community are concerned about how these power lines may have an impact on their lives, basically caused by their effects on health and safety. The landscape and visual impact is one of the most impact that can be easily perceived for local community. The computer 3D simulation of new landscape is illustrated by a real life use corresponding to the selection of the power line route with least observability for local community. This paper used ArcGIS(geographic information system tool) for planning, survey, basic route and detailed route, route for implementation of transmission line corridor. Also, the paper showed the map of natural environment, living environment, safety and altitude using database of power line corridor, and transmission siting model was developed by this study. The suggested landscape of computer simulation with lowest visibility on a power line zone can contribute to reducing oppositions of local community and accelerating the construction of new power lines.

A study on the Need for Introducing the Information and Communication Facilities Maintenance Mandatory System: In view of Apartment House Environment) (정보통신설비의 유지관리 의무화제도 도입 필요성에 관한 연구(공동주택환경을 중심으로))

  • Lim, Sang-Chool;Kim, Sun-Hyung
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.6 no.3
    • /
    • pp.15-24
    • /
    • 2007
  • According to an apartment house environment and the service provide method of major telecom operators, is providing optic-LAN service with installing the equipments of optical office center and optic distribution at MDF(Main Distribution Frame) and under-ground of apartment. therefore the distribute is deepening between service providers because of space securement to install equipments and spare pipe securement to reinstall UTP cable. These were reasons that operators leaned to subscriber collection and neglected to maintenance, in addition, insist the facilities invested by each operators is his own assets for all that in-plant of apartment house is private land. So, would not being touched by others. Accordingly, this study will search it through the field current condition examine that service's types and methods which various telecom operators and broadcast operators are providing, the current conditions of being maintained, the problems of being happened. etc. and would like to improve that the users could use the services safely by making the information & communication facilities maintenance mandatory under the regular size of apartment house circumstances through the analysis of various laws relations which are managed information & communication construction work law, telecommunication basis law, home network. etc. technical standards by the Ministry of Information and Communication and are managed housing law, construction law, the regulation related to house construct standards. etc. by the Ministry of Construction and Transportation.

  • PDF

A Study on Improvement Methods of Cost Estimation in Order for the Proper Management of Street Trees (도시 가로수 관리 품셈 개선에 관한 연구)

  • Do, Yoon-Taek;Han, Bong-Ho;Park, Seok-Cheol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.4
    • /
    • pp.20-36
    • /
    • 2022
  • This study aims to provide basic data for high-quality street tree management by setting reasonable management items and appropriate unit prices by reviewing the adequacy of current street tree management. Currently, street tree management items, except for street tree pruning, use general landscape tree quantity per unit for the street tree management quantity per unit. KEPCO (Korea Electric Power Corporation) applied pruning items from standard electric production infrastructure and carried out the activities at an average unit price of 51% lower for heavy pruning and 39% lower for light pruning than the standard estimate. This was judged to be a level that could not maintain or increase the quality of street tree management. It was determined that an appropriate standard unit price for street tree management was necessary. To improve the quantity per unit for the proper management of street trees, it was necessary to review costs in the field. However, due to the absence of data on actual construction costs in the domestic landscape field, detailed items of the US RSMeans Building Construction Cost Data (RSMeans) were reviewed, and the actual construction costs were calculated by applying personal domestic expenses. As a result, the standard of the estimated unit showed a good ratio of 107% for heavy pruning of street tree pruning compared to the actual construction cost, but light pruning was underestimated with a 59% ratio. Shrub pruning was 82%, weeding was 92%, tree fertilization was 87%, and windbreak wall installation was 91% under-engineered. In addition, it was also confirmed that the watering by sprinkler trucks and chemical spraying were over-designed compared to the actual construction cost at the rates of 118% and 124%, respectively. Due to the specificity of the street trees, the increase in personal expenses and the input cost of equipment, such as road safety controls, were judged to be the main cause of the underestimation of items. Therefore, it is necessary to add items related to street trees and general landscape trees to the landscape maintenance items of the standard of the estimated unit.

A Study on Fire Facilities of Urbane Buildings (도시건축물의 소방시설에 관한 연구(I))

  • 김소수
    • Fire Science and Engineering
    • /
    • v.6 no.2
    • /
    • pp.15-24
    • /
    • 1992
  • 우리나라는 1960년대의 경제개발계획에 따른 공업화 시축의 추진으로 산업의 발달과 경제성장은 인구를 도시로 집중시키면서 도시건축물은 대형화, 고층화, 과밀화 현상을 가져왔다. 한편, 국민생활의 향상과 산업활동의 다양화로 화재발생의 주요원인이 되는 전기, 가스, 유류등의 사용량이 해마다 늘어나고 있어 화재의 위험을 가중시키고 있다. 최근 10연간('81~'90) 전국에서 발생한 화재사고는 9만 5,154건이 발생하여 인명피해 1만1,117명, 재산피해 1,859억 2,200만원의 많은 손실을 가져 왔으며, 이 중에는 서울에서 발생한 화재가 3만6,089건으로 전체의 37.9%을 차지하고 있다. 화재가 발생할 경우 대형 참사를 방지하고 귀중한 인명피해는 물론 경제적 손실을 최저로 줄일 수 있는 소방시설을 도시건축물에 설치하여 이에 대비하는 것이 무엇보다 귀중한 일이다. 이는 화재예방 또는 발생 초기에 이를 감지, 통보하고 피난하며 소화활동에 이르는 모든 방재 및 소화를 위한 소방시설의 유용성을 최대로 발휘할 수 있기 때문이다. 본 논문에서는 서울특별시를 중심으로 도시건축물에 설치된 소방시설의 유지 관리 실태와 화재시 소방시설의 이용실태를 분석하여 문제점을 도출하고 이에 대한 개선방향을 제시하므로서 예방소방행정의 발전을 기하고저 하였으며, 그 내용을 요약하면 다음과 같다. 제1장에서는 서론부분으로서 연구의 목적과 범위및 접근 방법을 서술하였고, 제2장에서는 도시소방행정의 특성 및 소방환경의 변화로 먼저 소방행정의 의의와 도시소방행정의 유형으로 예방소방과 진압소방 그리고 구급.구조업무등을 살피고. 도시소방환경변화에 따른 화재발생추세를 살펴 보았다. 제3장에서는 도시건축물에 설치하는 소방시설의 설치.유지 및 이용실태를 검사.분석하였다. '90년도 서울시내 소방서에서 실시한 소방대상물에 대한 소방검사와 방화관리자에 대한 설문조사를 실시하여 소방시설의 유지관리실태를 통계.분석한 결과, 소방시설이 양호한 소방대상물은 전체의 75.9%이며, 불량소방대상물은 24.1%로 나타났다. 그리고 화재가 발생한 소방검사대상물에 대한 화재현장 조사결과 화재시 소방시설을 사용한 소방대상물은 전체의 72.1%를 차지하고 있다. 제4장에서 는 소방시설의 문제점으로 \circled1 소방설비부실공사, \circled2 소방시설 유지관리능력부족, \circled3 소방검사제도 불합리등이며, 이에 대한 개선방향으로 \circled1 소방설비 시공자의 지도. 감독강화, \circled2 자체시설관리능력향상, \circled3 예방소방행정제도의 개선을 제시하였다. 제5장은 결론으로, 우리나라가 최근 경제성장과 산업의 발달로 도시건축물의 화재발생 위험이 가중되면서 이에 대한 소방안전대비책이 요구된다. 이에는 도시건축물에 방화시설과 소방시설을 완비하고, 그리고 자격있고 유능한 방화관리자 선임하여 자체 소방계획을 수립하여 시설점검, 정비와 유지관리를 철저히 한다면 어떠한 화재도 예방 또는 초기에 진압할 수 있고, 또한 입주검자에 대한 소방교육 및 훈련을 지속적으로 수행하여 나간다면 여하한 도시건축물의 소방안전도 그 목적을 달성하리라고 생각한다.

  • PDF

A Pattern Analysis on the Possibility of Near Miss Connection in Construction Sites (건설현장의 아차사고 연결가능성에 대한 패턴분석)

  • Sang Hyun Kim;Yeon Cheol Shin;Yu Mi Moon
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.216-230
    • /
    • 2023
  • Purpose: The purpose is to prevent accidents by predicting disasters through the analysis of near-miss. Method: In this study, a near-miss literature review and data were collected at construction sites, and a questionnaire survey was conducted to use logistic regression analysis and decision tree analysis to classify the possibility of near-miss connection. Result: As a result of analyzing the effects of near-miss types on mental, physical, and safety habits and behaviors, the factor with a high influence on the body is the need for near-miss management, the type of job is electricity·information communication, and health status in order, and the mental factor is the construction scale The influence was high, and the factors with the highest influence on the habit behavior factors were analyzed in the order of experience, number of serious injuries, and occupation in order of illusion, inappropriate work instructions, and body parts. Through decision tree analysis, factors and patterns that affect the possibility of a near-miss being a surprise accident were identified. Conclusion: Construction site officials consider the observation of near-miss and mentally and physically. Specific management of the relevance of physical aspects to near-miss should be implemented, and a work environment in which serious accidents are reduced is expected through personnel allocation, work plans, work procedures and methods, and feedback so that inappropriate work instructions do not lead to near-miss.

Effect of Different Curing Methods on the Unconfined Compressive Strength of Cemented Sand (양생방법에 따른 고결모래의 일축압축강도 특성)

  • Park, Sung-Sik;Kim, Ki-Young;Choi, Hyun-Seok;Kim, Chang-Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5C
    • /
    • pp.207-215
    • /
    • 2009
  • Cemented soils or concrete are usually cured under moisture conditions and their strength increases with curing time. An insufficient supply of water to cemented soils can contribute to hydration process during curing, which results in the variation of bonding strength of cemented soils. In this study, by the consideration of in situ water supply conditions, cemented sand with cement ratio less than 20% is prepared by air dry, wrapped, moisture, and underwater conditions. A series of unconfined compression tests are carried out to evaluate the effect of curing conditions on the strength of cemented soils. The strength of air dry curing specimen is higher than those of moisture and wrapped cured specimens when cement ratio is less than 10%, whereas it is lower when cement ratio is greater than 10%. Regardless of cement ratio, air dry cured specimens are stronger than underwater cured specimens. A strength increase ratio with cement ratio is calculated based on the strength of 4% cemented specimen. The strength increase ratio of air dry cured specimen is lowest and that of wrapped, moisture, and underwater cured ones increased by square. Strength of air dry cured specimen drops to maximum 30% after wetting when cement ratio is low. However, regardless of cement ratio, strength of moisture and wrapped specimens drops to an average 10% after wetting. The results of this study can predict the strength variation of cemented sand depending on water supply conditions and wetting in the field, which can guarantee the safety of geotechnical structures such as dam.