• 제목/요약/키워드: 하천 유입

Search Result 1,633, Processing Time 0.036 seconds

Trophic State Index (TSI) and Empirical Models, Based on Water Quality Parameters, in Korean Reservoirs (우리나라 대형 인공호에서 영양상태 평가 및 수질 변수를 이용한 경험적 모델 구축)

  • Park, Hee-Jung;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.1
    • /
    • pp.14-30
    • /
    • 2007
  • The purpose of this study was to evaluate trophic conditions of various Korean reservoirs using Trophic State Index (TSI) and predict the reservoir conditions by empirical models. The water quality dataset (2000, 2001) used here were obtained from the Ministry of Environment, Korea. The water quality, based on multi-parameters of dissolved oxygen (DO), biological oxygen demand (BOD), chemical oxygen demand (COD), total phosphorus (TP), total nitrogen (TN), suspended solid (SS), Secchi depth (SD), chlorophyll-${\alpha}$ (CHL), and conductivity largely varied depending on the sampling watersheds and seasons. In general, trophic conditions declined along the longitudinal axis of headwater-to-the dam and the largest seasonal variations occurred during the summer monsoon of July-August. Major inputs of TP occurred during the monsoon (r=0.656, p=0.002) and this pattern was similar to solid dynamics of SS (r=0.678, p<0.001). Trophic parameters including CHL, TP, SD, and TN were employed to evaluate how the water systems varies with season. Trophic State Index (TSI, Carlson, 1977), based on TSI (CHL), TSI (TP), and TSI (SD), ranged from mesotrophic to eutrophic. However, the trophic state, based on TSI (TN), indicated eutrophic-hypereutrophic conditions in the entire reservoirs, regardless of the seasons, indicating a N-rich system. Overall, nutrient data showed that phosphorus was a primary factor regulating the trophic state. The relationships between CHL (eutrophication index) vs. trophic parameters (TN, TP, and SD) were analysed to develop empirical models which can predict the trophic status. Regression analyses of log-transformed seasonal CHL against TP showed that the value of $R^2$ was 0.31 (p=0.017) in the premonsoon but was 0.69 (p<0.001) during the postmonsoon, indicating a greater algal response to the phosphorus during the postmonsoon. In contrast, SD had reverse relation with TP, CHL during all season. TN had weak relations with CHL during all seasons. Overall, data suggest that TP seems to be a good predictor for algal biomass, estimated by CHL, as shown in the empirical models.

Primary Productivity and Pigments Variation of Phytoplankton in the Seomjin River Estuary during Rainy Season in Summer (하계 강우기 섬진강 하구역의 일차생산력 및 식물플랑크톤 색소조성 변화)

  • Min, Jun-Oh;Ha, Sun-Yong;Choi, Bo-Hyung;Chung, Mi-Hee;Yoon, Won-Duk;Lee, Jae-Seong;Shin, Kyung-Hoon
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.3
    • /
    • pp.303-313
    • /
    • 2011
  • Field observations and culture experiments have been carried out during the rainy season (on the 6th, 8th and 27th July 2009) to examine changes in the primary productivity and associated plant pigments in the estuary of the Seom-jin River. Primary productivity was determined at four sampling stations along the salinity gradient. On 6th July (before heavy rain) primary productivity ranged from 689~1,169 mgC $m^{-2}$ $d^{-1}$. On the 8th, just after more than 216.5 mm of precipitation, euphotic layers at all stations were reduced to very shallow water because of the high concentration of suspended solids in the water. This resulted in dramatically decreased primary productivity down to as low as 12~32 mg C $m^{-2}$ $d^{-1}$. However, after the rain, primary productivity on the 27th ranged from 266~999 mgC $m^{-2}$ $d^{-1}$, demonstrating a fast recovery in the upper stream water to similar productivity levels to those before the rainy season. Concentration of fucoxanthin in the water was highest on the 6th July. Before the rain, concentration of the zeaxanthin, increased as the salinity decreased. Immediately after the heavy rain, the Chl b (Chlorophytes) concentration was higher at all sites than before the rainy season. The concentration of fucoxanthin decreased after the heavy rain. At the downstream site, peridinin (Dinoflagellates) were found. During the rainy season, the diatoms contributed to the primary productivity at all sites. However, after the rainy season, Chl b (Chlorophytes) and Peridinin (Dinoflagellates) increased, demonstrating the enhanced contribution of those species in addition to diatoms.

Analysis of Fish Community Structures and Guild Compositions in Walpyung Conservation Park (월평공원 생태 보존지역의 어류군집 구조 및 어류길드 특성 분석)

  • Jo, Hyun-Kyu;Choi, Ji-Woong;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.3
    • /
    • pp.263-270
    • /
    • 2012
  • The objectives of the study were to determine fish fauna and compositions during 2010~2011 in Walpyung Conservation Park along with analysis of fish community structures and trophic and tolerance guilds. Total number of species and individuals sampled were 31 and 2667, respectively and dominant species was Zacco platypus (46.6%) and subdominant species was Acheilognathus lanceolatus (8.7%), which were composed of >50% of the total. Total number of Korean endemic species including Microphysogobio yaluensis was 10 and the proportion of the individuals was 8.7%. Also, natural monument No. 454 of Iksookimia choii, which is endangered species and legal protected species, was sampled and the total number of individuals was only three. According to the analysis of fish community structures, species richness index in the mid-stream reach ($M_r$) was 3.145, which is higher than any other stream reaches ($U_r$ and $D_r$). In contrast, the richness index was 2.180 in the up-stream reach ($U_r$), which is minimum among the sampling sites. Species diversity index was 1.785 and 1.975, respectively in the headwater ($U_r$) and mid-stream reach ($M_r$) and the low values in the down-stream reach ($D_r$, 1.660) were due to the influences of pointsource (i.e., road construction) and non-point sources (sporadic agricultural spots). According to analysis of tolerance guilds, the proportion of tolerant species (TS), based on the number of individuals, was composed of 64.2% and sensitive species (SS) was only 3.3%, indicating a predominance of tolerant fishes in the compositions. The proportion of omnivore species (OS), however, was composed of 64.0% and insectivore species (IS) was 29.3%, indicating a predominance of omnivore fishes in the stream. The high proportions of tolerant and omnivore species in this stream indicates that the water quality and physical habitat environments were degradated in this system. For these reasons, especially natural monument and endemic fish species in this region should be protected from the massive constructions and required to provide efficient stream management strategies.

Effect of a Floating Photovoltaic System (FPV) at Chungju Dam (Cheongpung Lake) on Water Quality (충주댐(청풍호) 수상태양광 시설이 호수 수질에 미치는 영향)

  • Kim, Hak Jun;Kwak, Suhknam;Yoon, Min;Kim, Il-Kyu;Kim, Young-Sung;Kim, Dong-sub
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.4
    • /
    • pp.293-305
    • /
    • 2019
  • In this study we investigated the effect of a floating photovoltaic (FPV) system in Cheongpung Lake on water quality. The FPV with a tilt angle of 33° covered ca. 0.04% of surface area (97 ㎢) of Chungju Lake. The water qualities of the whole lake before and after installation of FPV were first compared. DO, BOD, TOC, and Chl-a of the whole lake were increased, while conductivity decreased after installation period at the significance level of 0.05. This change was probably due to the increased influx of nutrients by 40% resulting from increased precipitation during the same period. We also measured water quality parameters on May and Nov. 2017 at the FPV center (FPVC) and nearby control sites, and compared water quality. The result showed that the FPVC and nearby sites were not significantly different (p>0.05), demonstrating that the FPV does not cause a decline of water quality. The water temperature, light intensity, and phytoplankton community were also measured. The water temperature was not different between the sites, while the light intensity decreased to 27~50%. Despite reduced light intensity at FPVC, the phytoplankton standing crops and the number of species were not significantly different (p>0.05). However, in the early November samples, standing crops was significantly higher in FPVC than control with periphytic diatoms belonging to Aulacoseira genus being dominant. This may be due to the temporal water body behavior or local retention of current by FPV system. This study may provide a measure of future installation of a FPV system.

Spatial Distribution of Soft Bottom Macrobenthos of Yeoja Bay in Summer Season, South Coast of Korea (여자만 연성저질의 여름철 대형저서동물 공간분포)

  • Lim, Hyun-Sig
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.20 no.2
    • /
    • pp.78-91
    • /
    • 2015
  • Macrobenthic community was studied at 87 stations including intertidal and subtidal area in Yoja Bay, south coast of Korea in summer season of July 2001. Duplicate sediment samples were taken using a van Veen grab ($0.1m^2$) in each station. Mud facies of the sediments were widly distributed in the bay. And relatively high content of sand was shown in the Bulgyo-cheon stream estuary. A total of 274 species was occurred with a mean density of $2,346ind./m^2$ and a mean biomass of $78.2g/m^2$. The polychaetes were species- and density-dominant faunal group with a total of 122 species (44.5% of the total number of species), and mean density of $1,543ind./m^2$ (65.8% of the mean density). Meanwhile, molluscs were biomass-dominant faunal group with $44.4g/m^2$. Bio-Env. analysis showed that the combination of bottom salinity and sand content of the surface sediments was highly correlated to the major macrobenthic communities. The macrobenthic species number, decreasing toward inner bay from mouth of the bay, was significantly correlated to the sediment environmental variables and bottom water salinity. The spatial distribution of abundance showed significant correlation to the sand and mud contents and mean grain size of the surface sediments. Major dominant species were Minuspio japonica (polychaete) with a mean density of $1,167ind./m^2$ at upper part of the bay where salinity was low and Eriopisella sechellensis (amphipod) with $152ind./m^2$ in central part of the bay. Species diversity (H') was $3.0{\leq}$ in the mouth part of the bay and ranged 2.0-3.0 in the inner part of the bay, which showed a significant positive correlation to bottom salinity. Total number of species also showed significant correlations to the sediment composition and bottom salinity. Based on the cluster analysis the macrobenthic community of the bay was classified into five station groups from the bay mouth toward the inner part of the bay depending on the species composition. From the SIMPER analysis Minuspio japonica, Eriopisella sechellensis and Sternaspis scutata mainly contributed to the classification of station group. These results suggested that the macrobenthic communities of the bay were mainly influenced by bottom salinity together with sediment composition, and that the studies of spatial distributions of major dominant species and benthic communities should be conducted continuously to monitor the Yeoja Bay benthic environment.

Heavy Metal Contamination of Soils and Stream Sediments at the Sanggok Mine Drainage, Upper Chungju Lake, Korea (충주호 상류, 상곡광산 수계에 분포하는 토양과 하상퇴적물의 중금속 오염)

  • 이현구;이찬희
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.1
    • /
    • pp.10-20
    • /
    • 1998
  • Heavy metal contamination in subsurface soils and stream sediments at the Suggok mine area were investigated on the basis of major, trace and rare earth elements geochemistry and mineralogy. The Sanggok mine area is mainly composed of Cambro-Ordovician carbonate rocks. The mine had been mined for Pb-Zn-Fe and Au- Ag, but already closed in past. For major elements, especially Fe (mean value=18.58 wt.%) and Mn (mean value=4. 18 wt.%) are enriched in soils, and the average enrichment indices of soils and sediments are 6.84 and 1.54, respectively. The average enrichment index of rare earth elements are 0.92 of mining drainage sediments and 0.52 of subsurface soils on the tailing dam. Concentrations of minor and/or environmental toxic elements in those samples range from 29 to 3400 for As,1 to 11 for Cd, 35 to 292 for Cu, 50 to 1827 for Pb, 1 to 22 for Sb and 112 to 2644 for Zn. Extremely high concentrations (mean values) are found in subsurface soils on the tailing dam (As=2278, Cd=7, Cu=206, Pb=1372, Sb=14 and Zn=2231 ppm, respectively). Average enrichment index normalized by composition of non-mining drainage sediments is 2.42 in mining drainage sediments and 25.47 in subsurface soils on the tailing dam. Based on EPA value, enrichment index of toxic elements is 0.53 in non-mining drainage sediments, 1.84 in mining drainage sediments and 23.71 in subsurface soils on the tailing dam. As a results from X-ray powder diffraction method, mineral composition of soils and sediments near the mine area varied in part, and are calcite, dolomite, magnesite, quartz, mica, chlorite and clay minerals. With the separation of heavy minerals, soils and sediments of highly concentrated toxic elements included some pyrite, arsenopyrite, sphalerite, galena, goethite and hydroxide minerals on the polished sections.

  • PDF

Degradation of Microcystin-LR, Taste and Odor, and Natural Organic Matter by UV-LED Based Advanced Oxidation Processes in Synthetic and Natural Water Source (UV-LED기반 고도산화공정을 이용한 수중 마이크로시스틴-LR, 이취미 물질, 자연유기물 분해)

  • Yang, Boram;Park, Jeong-Ann;Nam, Hye-Lim;Jung, Sung-Mok;Choi, Jae-Woo;Park, Hee-Deung;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.246-254
    • /
    • 2017
  • Microcystin-LR (MC-LR) is one of most abundant microcystins, and is derived from blue-green algae bloom. Advanced oxidation processes (AOPs) are effective process when high concentrations of MC-LR are released into a drinking water treatment system from surface water. In particular, UV-based AOPs such as UV, $UV/H_2O_2$, $UV/O_3$ and $UV/TiO_2$ have been studied for the removal of MC-LR. In this study, UV-LED was applied for the degradation of MC-LR because UV lamps have demonstrated some weaknesses, such as frequent replacements; that generate mercury waste and high heat loss. Degradation efficiencies of the MC-LR (initial conc. = $100{\mu}g/L$) were 30% and 95.9% using LED-L (280 nm, $0.024mW/cm^2$) and LED-H (280 nm, $2.18mW/cm^2$), respectively. Aromatic compounds of natural organic matter changed to aliphatic compounds under the LED-H irradiation by LC-OCD analysis. For application to raw water, the Nak-dong River was sampled during summer when blue-green algae were heavy bloom in 2016. The concentration of extracellular and total MC-LR, geosmin and 2-MIB slightly decreased by increasing the LED-L irradiation; however, the removal of MC-LR by UV-LED (${\lambda}=280nm$) was insufficient. Thus, advanced UV-LED technology or the addition of oxidants with UV-LED is required to obtain better degradation efficiency of MC-LR.

An Analysis on the Change of Smart City Space: Convergence Change of District, Street, Building and Facility (스마트시티 공간의 변화 분석: 지구, 가로, 건물, 시설의 융합 변화)

  • Han, Ju Hyung;Lee, Sang Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.537-550
    • /
    • 2018
  • The development focus of a smart city has been changed gradually from a physical development aspect to a space development aspect. In a space development aspect, the major application technologies are Environment Technology (ET), Information Technology (IT) and Environment Information Technology. On the other hand, it is unclear if the space convergence in a smart city has been changed by the 3 technologies. Therefore, specific analysis was performed on the convergence change of smart city 4 spaces (District, Street, Building, Facility) using the 3 technologies. The convergence distribution ratio according to the periods (period 1 : 1972~1999, period 2 : 2000~2009, period 3 : 2010~2017) among the spaces, ET (Environment Technology), IT (Information Technology), ET+IT (Environment Information Technology) in a smart city were examined. The smart city was high in the order of 'District (53/43%) - Building (36/29.1%) - Street (22/17.9%) - Facility (12/10.0%)' in the number of applications and ratio of convergence (Technology Convergence) at Period 1 (1972~1999). The smart city was high in the order of 'District (223/32.4%) - Building (197/28.6%) - Street (195/28.3%) - Facility (74/14.8%)' in the number of applications and ratio of convergence (Technology Convergence) at Period 2 (2000~2009). At period 3, the District (467/33%) was also the highest. On the other hand, the street (384/27.4%) was higher than the building (361/25.8%) and facility (188/13.4%) in smart city space. Fourth, the smart city was high in the order of 'District - Building - Street - Facility' in the number of applications and ratio of convergence (Technology Convergence) at Periods 1 (1972~1999) and 2 (2000~2009). In contrast, the average of number was high in the order of 'Building - Street - District - Facility'. At period 3(2010~2017), the number of applications and the ratio of convergence was high 'District - Street - Building - Facility'; the average of number was the same as in period 1 and 2. As a result, smart city space has been changed by the development of macroscopic urban spaces in the initial stage. Since then, district space-centric development and building space are confused with devices/technologies and changed for citizen inflow. The building space has evolved continually and smart city space will be expected to revitalize the street space connecting completed buildings.

The Research of Storage Capacity & Sedimentation of Reservoirs in HONAM Province (호남지방에 저수지의 매몰상황과 저수량에 관한 조사연구(농학계))

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.2
    • /
    • pp.2262-2275
    • /
    • 1971
  • Fourteenes rervoirs maintained by the local land improvement associations in the province of Chullabuk-Do and 20 reservoir maintained by thos in the province of Chullanam-Do, were surveyed in connection with a correction between storage capacity and sediment deposit. In addition to this survey, 3,347 of small reservoir, that lie scattered around in the above-mentioned two provinces were investigated by using existing two provinces were investigated by using existing records pertaining to storage capacity in the office of City and country, respectively. According to this investigation the following comclusions are derived. 1. A sediment deposition rate is high, being about $10.63m^3/ha$ of drainage area, and resulting in the average decreasc of storage capaity by 27.5%. This high rate of deposition coule be mainly attributed to the serve denudation of forests due to disorderly cuttings of trees. Easpecially, in small reservoir, an original average design storage depth of 197mm in irrigation water depth is decreased to about 140mm. 2. An average unit storage depth of 325.6mm as the time of initial construction is decreased to 226mm at present. This phenomena causes a greater shortage irrigation water, since it was assumed that original storage quantity was already in short. 3. Generally speaking, seepage rates through dam abutment intakepipe, etc, are high due to insufficient maintenance and management of reservoir. 4. It is recommended that sediment deposit should be dredged when a reservoir is dry in drought. 5. Farmers usually waste excessive irrigation water. 6. Water saving methods should be practiced by applying only necessary water for growing stage of rice. 7. In are as where water defficiency for irrigation is severe, a soil moisture content should be kept at about 70% by applying water once in several days. 8. Tube wells should be provided so as to exploit ground water and subsurface current below stream bed as much as possible. 9. If an intake weir was constructed, a water collection well should be built for the use in drought. 10. Water conservation should be forced by converting devastated forests contained in the drainage area of reservoir to protected forests so as to take priority of yrefor estation, gully control, the prohibition of disorderly cutting of trees, etc. 11. Collective rice nurseries should be adopted, and it should be recommended that irrigation water for rice nurseries is supplied by farmer themselves. 12. Sediment desposit in reservoir should be thoroughly dreged so as to secure a original design storage capacity. 13. The structure of overflow weir should be automatic so as to freely control flood level and not to increase dam height.

  • PDF

Study on the Characteristics and Non-point Source Pollution Loads in Stormwater Runoff of Shihwa Lake (시화호 유역 비점오염물질의 유출특성 및 부하량 연구)

  • Ra, Kong-Tae;Kim, Kyung-Tae;Kim, Joung-Keun;Bang, Jae-Hyun;Lee, Jung-Moo;Kim, Sung-Keun;Kim, Eun-Soo;Yun, Min-Sang;Cho, Sung-Rok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.1
    • /
    • pp.40-50
    • /
    • 2011
  • We study the characteristic and total flux of non-point pollutants such as total suspended solids (TSS), chemical oxygen demand (COD), dissolved nutrients, total phosphorus (TP) and total nitrogen (TN) in the storm water runoff from urban streams and sewer outlets of Banweol Industrial Complex around Shihwa Lake. The concentrations of non-point pollutants were generally increased with increasing of the duration and intensity of rainfall. Mean TSS concentration of Ansan stream was higher than that of sewer outlets but mean concentrations of COD, TP and TN were approximately 2~5 times higher of sewer outlet than of urban stream. TSS showed statistically positive relationships with COD and TP but it had negative correlation with dissolved nutrients. There was a significant correlation between total flux of non-point pollutants in the storm water runoff and total basin area of each sewer outlet, showing that the highest runoff flux was observed at 3rd sewer outlet which represents the largest basin area from Banweol industrial complex. Total runoff fluxes for TSS, COD, TP and TN in this study were 187,536 kg, 17,118 kg, 922 kg, 13,519 kg, respectively. Given the basin area of sewer outlet in Banweol industrial complex which corresponds only 3% from total catchment area around Shihwa Lake, enormous amount of non-point pollutants will be entered into Shihwa Lake without any treatment. It is necessary to manage and reduce of various non-point sources and pollutants because the runoff of nonpoint pollutants during storm events should be deteriorating the water quality of Shihwa Lake. Our results provides useful informations on the development of best managements practices (BMPs) for effective implementation of total pollution loads management system of Shihwa Lake.