• Title/Summary/Keyword: 하중진폭

Search Result 167, Processing Time 0.028 seconds

Changes of Hysteresis Loop Characteristics of the Tendon Under Tensile Stress (Tendon의 인장응력에 따른 자기이력특성 변화의 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.123-128
    • /
    • 2015
  • The iron is an element having a high yield strength, mechanical hardness, good electrical conductivity, and also it has been used in various fields because of ease machining. In bridges have been used tendon made of a steel wire for large loads and light weight. Tension measurement of tendon employed in PreStressed Concrete (PSC) bridge is very important for the bridge safety check. NDT (Non-Destructive Testing) is essential for the safety check, however, magnetic NDT is difficult to apply due to the non-linear magnetization curve and hysteresis loop in the magnetic properties. In this work, for basic study of magnetic NDT application, we have constructed a B-H loop measuring system for 7-strand tendon of which diameter is 15.5 mm, and which can apply tensile stress up to 2.0 GPa. We have measured hysteresis loops of two kinds of tendons under different tensile stress. Amplitude permeability and maximum magnetic induction near knee show the most sensitive and high linearity depends on tensile stress. Relative amplitude permeability was decreased from 500 to 200 and maximum magnetic flux density changed 0.6 T.

Characterization of Stress Corrosion Cracking at the Welded Region of High Strength Steel using Acoustic Emission Method (음향방출법에 의한 고 장력강 용접부의 부식손상 특성 평가)

  • Na, Eui-Gyun;Kim, Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.212-219
    • /
    • 2003
  • This study is to evaluate the characteristics of SCC at the welded region of high strength steel using acoustic emission(AE) method. Specimens were loaded by a slow strain rate method in synthetic seawater and the damage process was monitored simultaneously by AE method. Corrosive environment was controlled using the potentiostat, in which -0.8V and -1.1V were applied to the specimens. In the case of one-pass weldment subjected to -0.8V, much more AE counts were detected compared with the PWHT specimen. It was verified through the cumulative counts that coalescence of micro cracks and cracks for the one pass weldment with -0.8V were mostly detected. In case of the one pass weldment subjected to -1.1V, time to failure became shorter and AE counts were produced considerably as compared with that of the two pass weldment. It was shown that AE counts and range of AE amplitude have close relations with the number and size as well as width of the cracks which were formed during the SCC.

Prediction on Mooring Tension & Motion Response Characteristics of a Floating Dock in Regular Waves (규칙파 중 플로팅 도크의 운동응답특성 및 계류장력 추정)

  • Oh, Young-Cheol;Gim, Ok-Sok;Ko, Jae-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.200-206
    • /
    • 2013
  • The paper was investigated on the mooring forces(or tension) and motion response characteristics for a 8-point mooring floating dock in regular waves using a commercial code(AQWA). To achieve the aim of the research, a numerical simulation was adapted on an inner port environment condition, which the water depth is 10 meters, significant wave amplitude(1.05 m). wave period(3.85 sec), wind speed(20.21 m/s), wind and current direction ($90^{\circ}$), incident waves(${\chi}=180^{\circ}$, $135^{\circ}$ and $90^{\circ}$). The dimension of the numerical model is length(140 m), breadth(32 m), depth(14.6 m). The maximum length of a mooring line is 120m. We can expected that roll and pitch motions appeared in beam seas better than head sea. the mooring forces also indicated higher in bean seas than in head seas including wind forces.

Correlation between Overload Retardation and Hardening Exponent (과부하로 인한 균열지연과 변형경화지수와의 상호관계)

  • Sang-Chul,Kim;Jin-Man,Jeong;Moon-Sik,Han
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.2
    • /
    • pp.41-48
    • /
    • 1989
  • This paper investigates the relationship between strain hardening exponents(n) of various marine materials and fatigue crack retardation effect after applying single overload. Using the four different sheet materials, following results are obtained. (1) The fatigue crack propagation rate after applying single overload was retarded and the effects of this retardation were closely related to the strain hardening exponent. (2) The larger the strain hardening exponents were, the more were the fatigue crack retardation effects after applying single overload. (3) The considerable crack closure with the applying of a overload was observed in matrals with large strain hardening exponent. When n is smaller than 0.1, the fatigue crack retardation effects are negligible. On the contrary, when n is larger than 0.2 the fatigue crack retardation effects are significant.

  • PDF

Numerical Simulation on the Behavior of Air Cloud Discharging into a Water Pool (수조로 방출되는 기포 거동에 대한 수치해석)

  • 김환열;김영인;배윤영;송진호;김희동
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.237-246
    • /
    • 2002
  • If the safety depressurization system of APR-1400, the Korean next generation reactor, is in operation, water, air and steam are successively discharging into a in-containment refueling water storage tank through spargers. Among the phenomena occurring during the discharging processes, the air bubble clouds produce a low-frequency and high-amplitude oscillatory loading, which may result in the most significant damages to the submerged structures if the oscillation frequency is the same or close to the natural frequency of the structures. The involved phenomena are so complicated that most of the prediction of frequency and pressure loads has been resorted to experimental work and computational approach has been precluded. This study deals with a numerical simulation on the behavior of air bubble clouds discharging into a water pool through a sparger, by using a commercial thermal hydraulic analysis code, FLUENT, version 4.5. Among the multiphase flow models, the VOF (Volume Of Fluid) model was selected to simulate the water, air and steam flows. A satisfactory result was obtained comparing the analysis results with the ABB-Atom test results which had been performed for the development of sparser.

Acoustic Emission Characteristics during fracture Process of Glass Fiber/Aluminum Hybrid Laminates (유리섬유/알루미늄 혼합 적층판의 파괴과정과 음향방출 특성)

  • Woo, Sung-Choong;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.274-286
    • /
    • 2005
  • Fracture behaviors and acoustic emission (AE) characteristics of single-edge-notched monolithic aluminum plates and glass fiber/aluminum hybrid laminate plates have been investigated under tensile loads. AE signals from monolithic aluminum could be classified into two different types: signals with low frequency band and high frequency band. High frequency signals were detected in the post stage of loading beyond displacement of 0.45mm. For glass fiber/aluminum laminates, AE signals with high amplitude and long duration were additionally confirmed on FFT frequency analysis, which corresponded to macro-crack propagation and/or delamination between A1 and fiber layers. On the basis of the above AE analysis and fracture observation with optical microscopy and ultrasonic T scan, characteristic features of AE associated with fracture processes of single-edge-notched glass fiber/aluminum laminates were elucidated according to different fiber ply orientations.

Simplified 2D Analysis for Suspension Bridges Subject to Wind Excitation (현수교 풍진동에 관한 2D 간단해석 및 변수연구)

  • Kim, Woo Seok;Lee, Jaeha
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.6
    • /
    • pp.463-470
    • /
    • 2013
  • In this paper, 2D simple analyses were performed in order to predict the large torsional oscillations in a suspension bridge based on Makenna and Tuama model(2001). The existing model(Makenna and Tuama, 2001) has shown unrealistic results as the wind speed increases and frequency decreases. Furthermore, resonance could not be simulated by the existing model. Therefore, in this study, new model was proposed with a consideration of the torsional resistance. The vertical and rotational behaviors of the deck in the suspension bridge were analyzed. Analysis results showed that at first vertical oscillations were observed and it was gradually transformed to the rotation oscillations. With the consideration of the torsional resistance, it was shown that vertical behavior were stabilized as time passed. However, the rotational behavior was not stabilized and was kept until the end of analysis. Beat periods decreased while the wind speed increased. The resonance of the rotational mode was dependent to the rotational resistance. Obtained results could be applied for the design of the suspension bridge under the wind load.

Fatigue Behavior of Large Stud Shear Connectors (대직경 스터드 전단연결재의 피로거동)

  • Shim, Chang Su;Lee, Pil Goo;Kim, Hyun Ho;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.621-628
    • /
    • 2003
  • Stud shear connectors are the most commonly used shear connectors: up to 22mm studs are usually used in steel-concrete composite structures. To expand the current design codes for stud connectors, large studs with a diameter of more than 25mm should be investigated. Through push-out tests on large stud shear connectors that transcend the limitation of current design codes, fatigue behavior was investigated and comparisons with design equations performed. The shear stiffness of the connectors in elastic range was evaluated through shear tests on 25mm, 27mm, and 30mm studs and compared with those from static tests. The fatigue behavior of large studs was discussed in terms of residual slip and load-slip curves. The initiation of fatigue cracks in the welding part could be detected through the history of displacement range. Test results showed that the design fatigue endurance of S-N curves in current design codes could be applied to large stud shear connector.

Fatigue Analysis of External Fuel Tank and Pylon for Fixed Wing Aircraft (고정익항공기용 외부연료탱크 및 파일런 피로 해석)

  • Kim, Hyun-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.162-167
    • /
    • 2020
  • In this study, a fatigue analysis of an external fuel tank and pylon for fixed-wing aircraft was carried out as part of the domestic development of fixed-wing aircraft. Through structural analysis, the analysis areas were selected, and the transfer function for unit loads was established in the selected parts. For each of the continuous load profiles, stress components in the selected areas were calculated using the load of each profile and the transfer function, and the Von Mises equivalent stress was employed as the representative stress of each profile. In addition, the rainflow counting technique was used to extract individual profiles obtained from the initial large load profiles and to calculate their amplitude and average values. For life evaluation, the S-N diagram of the Metallic Materials Properties Development and Standardization (MMPDS) was applied, and the damage value was calculated by Miner's rule to assess the life of the selected area. As a result of the life assessment, the life span requirement for the selected area of the external fuel tank and the pylon was assessed as being satisfied.

Histogram Recorder System에 의한 측정예

  • Han, Eung-Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.2 no.1
    • /
    • pp.21-27
    • /
    • 1985
  • 차량, 항공, 교량 및 기계구조물 등 랜덤한 실동하중을 받는 구조물의 응력 및 변위, 진동등의 피로 Data 또는 TRAFFIC 등에 의한 건축물의 변위 및 응력발생빈도를 집록하기 위한 Histogram Recorder System에 대한 내용과 측정예를 소개하고자 한다. 본 System은 8(4)챈 널의 스트레인 게이지 또는 스트레인 게이지식 각종변환기와 각종 Sensor로부터의 출력전압 등 Analog 입력을 수록하여, Digital 처리하여 micro computer를 사용, 미리 프로그램된 방식에 따라 측정과 동시에 실동시간으로 해석처리하여 빈도수로서 내부에 기억저장 시키는 것이다. 따라서 본 Histogtram Recorder 본체는 소형으로 견고하며 조금도 제어부분을 갖지 않고 소요의 해석방법의 프로그램백만을 셋트한 개별의 제어기만을 통해가지고 프로그램을 기입만 하며는 그다음은 손하나 안대고도, 그리고도 또 측정중에 제3자에 의한 제어조작 잘못이 발생할 위험도 없고 1 년이상에 걸친 장기간의 .+-. 32 Slices의 각 레벨당 각각 40 억을 넘는 대량의 빈도수를 자동적으로 집록 할 수가 있다. 집록된 Data는 제어장치에 의해 정리된 Datam는 제어장치에 의해 정리된 Histogram의 형태로 읽어나갈 수가 있어 관찰이 가능할 뿐만 아니라 프린터기록 또는 기록장치에 이송시켜서 Data 만 따로 가져올 수가 있어 필요에 따라서는 one line으로 Host computer에 접속시킬 수가 있어 더욱 고도의 처리를 할 수가 있다. 빈도해석프로그램으로서는 극대, 극소, 최대, 최소, 진폭, 시간 등을 pack으로서 준비되어 있어 이에 대한 시스템의 고성 동작 및 성능등을 소개하고자 한다.

  • PDF