• Title/Summary/Keyword: 하중작용면적

Search Result 51, Processing Time 0.03 seconds

Effects of Bar Deformation on Bond between Reinforcing Steel and Concrete Subjected In Cyclic Loading (반복하중시 철근의 마디형태에 따른 부착특성)

  • 최완철;이재열;이웅세
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.244-250
    • /
    • 2001
  • One of the reasons for brittle failure in reinforced concrete structures subjected to severe earthquake is due to large slip between reinforcing steel and concrete. This study aims to evaluate effects of deformation patterns of ribbed reinforcing bars on bond under cyclic loading. Bond test specimens were constructed with machined bars to test the newly developed reinforcing bars with high relative rib areas. The degree of confinement is also another key parameter in this bond test. From the test results under monotonic and cyclic loading, bond strength and stiffness were evaluated. Bond strength and bond stiffness increase as relative rib areas under cyclic loading for specimens highly confined by transverse reinforcement. The increase rates of the bond performance under cyclic loading are larger than those of specimens under monotonic loading. The developed bars with high relative rib areas will contribute for better bond performance for reinforced concrete structures subjected to severe seismic loadings.

원자력 발전소 건물의 내진해석 모델

  • Heo, Young
    • Computational Structural Engineering
    • /
    • v.4 no.1
    • /
    • pp.17-19
    • /
    • 1991
  • 본 글에서는 ANS(American Nuclear Society)에서 규정하고 있는 Safety Class 구조물 중 격납건물의 내진해석모델에 대해 주로 언급하며, 기타 건물(Non-Nuclear Safety "NNS")은 일반건물과 차이점이 없음으로 언급하지 않는다. U.S. NRC(Nuclear Regulatory Commision)는 참고문헌[1]에 의해 원자력 발전소내 여러건물중 SSE(Safe Shutdown Earthquake)하중에도 견디도록 규정하여 정확한 동력학적 계산이 요구되어지나, 그 이외의 건물들은 대개 등가정적 방법에 의해 해석되어진다. 이 해석방법은 여러 빌딩규정들에서 제안된 것으로 지진에 의한 동적하중을 밑면적 단력 또는 각층에 작용하는 층전단력이라는 등가의 정적하중으로 바꿔 계산되며 이 때 사용되는 해석모델은 건물의 기본진동만을 표시할 수 있는 간단한 것이다.

  • PDF

Wind Tunnel Investigation of Fluctuating Pressure Inside Building (풍하중에 의한 건물내부 압력의 동적변화에 관한 연구)

  • 이경훈
    • Computational Structural Engineering
    • /
    • v.3 no.4
    • /
    • pp.133-141
    • /
    • 1990
  • The nature of fluctuating air pressure inside building was studied by testing a building model in a wind tunnel. The model has a single room and a window opening. Various opening conditions were tested in both laminar uniform wind and turbulent boundary-layer wind. The RMS and the spectra of the fluctuating internal pressure were measured. The test results support a recent theory which predicts the behavior of internal pressure under high wind based on aerodynamic analysis.

  • PDF

A Study on the Stress Concentration and Diminishing in Structural Member with Arbitrary Section Using Finite Element Method (유한요소법을 이용한 집중하중을 받는 임의단면형상부재에서 응력집중현상과 소멸현상에 관한 연구)

  • 최종근;이종재;김동현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1069-1078
    • /
    • 1990
  • It is shown that the performance of finite element based on energy orthogonal functions may be superior to conventional formulation for plane stress problem. Using this finite element, it is then attempted to show the distribution of stress concentration effect for subsurface under loading point. It turned out that the stress concentration effect for subsurface is not dependent on the width of the member but the loading area. And then it is shown that the solution attained by taking the stress function as a Fourier series is not satisfactory in y<0.1B.

특이함수에 의한 보의 처짐 및 부정정보 문제의 풀이

  • 심재헌
    • Journal of the KSME
    • /
    • v.23 no.6
    • /
    • pp.448-458
    • /
    • 1983
  • 보의 처짐(deflection of beam) 및 부정정보(statically indeterminate beam)의 문제는 수문이나 압력용기등을 비롯한 각종 구조물의 강도계산에서 설계자가 자주 부딪치는 문제이다. 일반적으로 분포하중이나 집중하중 또는 집중 모우멘트가 작용하는 보, 특히 부정정 보의 경우 해석하기 쉬운 방법을 찾아 모우멘트-면적법, 중첩법, 3-모우멘트의 방정식등을 사용하여 반력이나 반력 모우멘트, 처짐량 등을 계산하고 있다. 그러나 이들 방식들은 일률적으로 어느 경우에나 적용하기에 적합한 것은 아니고 복잡한 각종 정리나 공식들을 사용하여야 하며 공액보(conjugated beam)의 반력을 구한다든가, 선도의 면적을 구하기 위하여 힘든 계산을 행하여야 하는 등 쉽지 않아, 부정정 보를 풀어야 할 경우가 발생할 때마다 좀 더 쉬운 접근방법이 없을까 하는 애로를 느껴왔다. 그러던 차 특이함수를 도입하여 문제의 해결을 시도하여 본 바, 복잡한 공식들을 외울 필요 없이 규칙적이고 일률적인 방법으로 쉽게 문제의 해결이 가능하기에 여기 간단히 풀이 방법을 소개하고자 한다.

  • PDF

Analysis of the Characteristics of Wind Pressure Coefficient Working on Monosloped Roof Surface (편지붕형 지붕면에 작용하는 풍압계수 특성분석)

  • You, Ki-Pyo;Cho, Seul-Gi;Kim, Young-Moon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.4
    • /
    • pp.81-88
    • /
    • 2009
  • Damage on low?rise buildings caused by typhoons and storms is increasing every year. Thus, this study examined the distribution of wind pressure coefficient at each position according to the height of monosloped roof, and measured wind pressure coefficient according to tributary area and compared it with the current wind load standard. We analyzed six areas in order to analyze characteristics at each position of a half span roof, and found that the wind pressure coefficient was around 25% higher at the high comer (HC) than at the low corner (LC). The distribution pattern of peak pressure coefficient at each position was the same as the AIK load standard, but in the results of our experiment, wind pressure was around 40% lower than the load standard at HC and around 37% higher than the load standard at LC.

  • PDF

Settlement Behavior of Foundation Rubble-mound by Vibro-Compaction (진동다짐에 의한 기초사석의 침하거동)

  • Yoo, Kun-Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4C
    • /
    • pp.127-136
    • /
    • 2011
  • The settlement of a compaction plate resting on the surface of rubble-mound and subjected to a vibrating vertical load can be characterized by a transient amplitude and a plastic settlement. As long as the maximum imposed load does not exceed the bearing capacity of the rubble-mound, plastic settlement will approach an ultimate value and essentially steady-state vibration will ensue. For the settlement behavior by vibro-compaction, most laboratory experiments were conducted on laterally confined samples with loads over the full surface area or on samples placed on a vibrating table. In the field, the loads cover only a small fraction of the surface area. In this study, crushed stones are loaded with the same as field condition. According to the vibro-compaction experiments on crushed stone, it was found that approximately 90% of total settlement occur within 2 minutes and plastic settlement increases with increasing cyclic stress levels including static and dynamic stress. A compaction equation on which the number of load cycles, amplitude of plate, settlement, width of plate, and cyclic stress are related each other is proposed.

Effect of Compressive Loading on the Chloride Penetration of Concrete Mixed with Granulated Blast Furnace Slag (고로슬래그미분말을 혼입한 콘크리트의 염분침투성에 미치는 압축하중의 영향)

  • Kim, Dong-Hun;Lim, Nam-Gi;Horiguchi, Takashi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.6
    • /
    • pp.71-78
    • /
    • 2009
  • The analysis of the effect of loading on chloride penetration into concrete is very important. In this study, we confirmed that the chloride penetration rates for plain and BFS concrete were increased by 47% and 89% under compressive stress, respectively. The diffusion coefficient of BFS concrete was lower than for conventional concrete with no BFS, no loads, and under stressed states. Therefore, BFS substitution plays an important role in the repression of chloride penetration even under compressive stress. Under compressive stress,the diffusion coefficient for BFS concrete was higher with increasing stress, and this was also the case for plain concrete. However, BFS concrete was strongly influenced by compressive stress in comparison to plain concrete. We investigated the effect of the difference of specific surfaces on the diffusion coefficient. As a result, the larger specific surface of BFS exhibited a lower diffusion coefficient. This tendency was most pronounced under the high stress conditions.

Analytical Study on Dynamic Characteristics of Hydraulic Cylinder Applied to the Vehicle Holding Device for Launch Vehicle (발사체용 지상고정장치 구동유압실린더의 운동특성에 관한 해석적 연구)

  • Lee, Jaejun;Park, Sangmin;Yang, Seongpil;Kim, Daerae
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.1
    • /
    • pp.44-50
    • /
    • 2017
  • Vehicle Holding Device(VHD) has a role that holding the launch vehicle on its launch pad until the engine therust reaches a steady condition. The analytical study of shape parameters and dynamic characteristics of hydraulic cylinders is carried out. The contraction of cylinder is considered as the major factor of releasing mechanism. Through the analysis, the decreasing of cylinder slit size and increasing initial charging pressure increase the contraction force. Through the transient analysis, cylinder load, displacement and inner pressure distribution are confirmed. The cylinder contraction force is converged to the cylinder external force when the cylinder starts to move. Also, the pressure distribution in the hydraulic cylinder is constant.

Effect of the Combination of Point Loads on the Design Flexural Capacity for Fiber Reinforced Concrete Floor Slab (집중하중 조합에 의한 섬유 보강 콘크리트 바닥슬래브의 설계 휨 내력)

  • Lee, Jong-Han;Cho, Baik-Soon;Kim, Jung-Sik;Cho, Bum-Gu;Ki, Han-Sik
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.1
    • /
    • pp.47-54
    • /
    • 2016
  • In this study, the flexural capacity of fiber reinforced concrete floor slabs were evaluated using main design loads, racking and moving loads. Based on design standards and guidelines, the magnitude and loaded area of each load were determined, and its relationship was assessed. For the application of a single load, flexural capacity should be evaluated in the edge of a floor slab. In addition, the slab with thickness and concrete strength, greater than 180mm and 35MPa, respectively, sufficiently satisfied flexural capacity with a minimum of equivalent flexural strength ratio. The combination of racking loads required the largest equivalent flexural strength ratio to satisfy the flexural capacity of the floor slab. The combination of racking and moving loads showed equivalent flexural strength ratio smaller than the case of combination of racking loads, but larger than the application of single racking or moving loads. The results of this study indicated that the flexure of fiber reinforced concrete floor slabs should be designed using the combination of design loads.