• Title/Summary/Keyword: 하중막

Search Result 79, Processing Time 0.027 seconds

$H^{\infty}$ Controller Design for RTP System using Weighted Mixed Sensitivity Minimization (하중 혼합감도함수를 이용한 RTP 시스템의 $H^{\infty}$ 제어기 설계)

  • Lee, Sang-Kyung;Kim, Jong-Hae;Oh, Do-Chang;Park, Hong-Bae
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.6
    • /
    • pp.55-65
    • /
    • 1998
  • In industrial fields, RTP(rapid thermal processing) system is widely used for improving the oxidation and the annealing in semiconductor manufacturing process. The main control factors are temperature control of wafer and uniformity in the wafer. In this paper, we propose an $H^{\infty}$ controller design of RTP system satisfying robust stability and performance using weighted mixed sensitivity miniimization and loop shaping technique. And we need reduction technique because of the difficulty of implementation with the obtained high order controller for original model and reduced models, namely, Hankel, square-root balanced, and Schur balanced methods. An example is proposed to show the validity of the proposed method.

  • PDF

인공치아와 표면처리

  • Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.121-121
    • /
    • 2016
  • 치아는 인체중에서도 혹한 환경에서 부분으로 높은 하중과 타액과 같은 강 부식성 매체로 그 환경이 상상을 초월한다. 즉 반복적으로 가해지는 하중(응력)과 침식을 유발하는 타액과 음식물 등이다. 따라서 치아가 쉽게 파괴되거나 썩는 현상이 나타나게 된다. 이렇게 사용되다가 치아의 역할을 다하게 되면 인공치아를 사용하게 되는데 그 재료가 바로 타이타늄(Ti)이다. 생체매식재로 사용되는 Ti는 반응성이 높아 산소와 쉽게 결합하여 표면에 TiO, $TiO_2$, 및 $Ti_2O_3$와 같은 산화피막을 표면에 형성함으로써 뛰어난 부식저항성과 생체적합성을 가지며 생체에 독성이 없고 탄성계수가 골과 비슷하여 골과 임플란트 경계면에서 응력분산에 유리한 성질 등 물리적, 기계적 성질이 뛰어나 외과용 임플란트 재료로 가장 좋은 재료이다. 금속 임플란트의 생체적합도는 임플란트 재료 자체보다는 생체 내 산화막이 화학적으로 불안정할 때 부식이 발생하게 되고 그 결과 금속이온이 주위로 유리되어 조직반응을 일으키므로 금속의 표면을 덮고 있는 산화막에 의해 좌우된다. Ti는 생체불활성재료로서 매식재료로 사용할 경우 뼈와 잘 융합되는 골유착을 나타내나 골과 화학적결합은 하지 않고 골형성을 적극적으로 유도하지 못함으로 환자의 치유기간이 길어지게 된다. 이러한 이유로 골조직내 임플란트의 접합을 개선하기위한 연구가 이루어져 골과의 결합을 높이기 위해 골유착을 일으키는 Ti에 골성장을 유도하는 뼈성분인 하이드록시 아파타이트(HA)라는 물질을 플라즈마 코팅법을 사용하던가 아니면 Hanks' solution내에서 침적 후 HA도금을 하는 방법 등으로 처리하고 있다. 그러나 플라즈마 코팅법은 고온에서 처리를 행하고 Hanks' solution내에 침적할 경우 Ti표면에 밀착도가 저하되거나 합금의 상변화 등으로 인하여 표면처리 과정 중에서 내식성이 크게 감소될 수 있다. 이러한 여러 가지 코팅법을 통하여 골 유착을 증진시키기 위한 연구는 계속되고 있지만 임상적으로 사용 후 문제가 단시일에 발생되는 것도 아니고 수년이 지나야 나타나게 된다. 이러한 방법으로 코팅을 하게 되면 골과 잘 유착이 되어 자연차아와 같은 기능을 하게 된다. 따라서 이러한 문제를 최소화하는 방법이 나노구조를 표면에 형성시켜 골유착을 쉽게 함으로써 이를 개선할 수 있을 것으로 생각되어 본 강의에서는 임플란트의 문제와 사용되는 재료에 대하여 고찰하여 자연치아를 대체 할 수 있는지 알아보았다.

  • PDF

Hydraulic Experiment on Roughness Coefficient of PE pipe (폴리에틸렌관의 조도계수에 관한 수리모형실험)

  • Dongwoo Ko;Byeong Wook Lee;Jae-Seon Yoon;Hyun-Gu Song
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.288-288
    • /
    • 2023
  • 도로, 철도 등의 횡단통로, 오폐수관로, 지하배수관 등 연약지반에서 상재하중과 부등침하에 의한 파괴 위험을 줄이기 위해 구조적인 안전성과 내구성이 개선된 다양한 관로들이 활용되고 있다. 관은 매설특성에 따라 콘크리트관, 도관, 합성수지관, 덕타일 주철관, 파형강관, 유리섬유 강화 플라스틱과 폴리에스테르수지 콘크리트관 등의 종류로 구분된다(환경부, 2017). 수리설계 시 이러한 관의 단면 규모 결정 및 흐름 특성을 파악하기 위해 관수로 유량측정에 이용되는 Manning의 경험식을 이용하고 있으며, 관로의 주요 재질에 따른 다양한 조도계수가 제시되어 있다. 새로운 재질을 이용하여 제작된 관은 수리실험을 통해 조도계수를 결정하는 것이 바람직하지만, 조도계수 실험은 대규모의 실험시설과 유량공급이 요구되기 때문에 여러 한계가 있다. PE관의 경우, 미국의 ASTM 표준에 의해 저밀도 폴리에틸렌(LDPE), 선형 저밀도 폴리에틸렌(LLDPE), 고밀도 폴리에틸렌(HDPE) 등으로 분류되는데 본 연구에서는 HDPE 재질의 서로 직경이 다른 다중벽관 PE관을 대상으로 조도계수를 결정하기 위한 현장 실규모 수리실험을 수행하였다. 본 실험에서는 식생, 수로의 불규칙성, 수로노선, 침전과 세굴, 장애물, 계절적 변화, 부유물질과 소류사는 무시되며 표면조도, 관의 크기와 형상, 수위와 유량이 조도계수에 영향을 미치는 주요 인자라고 할 수 있다. 수리실험은 실물모형(Prototype)으로 한국농어촌공사 농어촌연구원의 대형수리모형실험장에서 수행되었으며. 길이 24 m, 직경 150 mm의 PE 관은 고정식 개수로, 직경 800 mm의 관은 대형유사순환수로에 각각 설치되었다. 관로의 전면에 차폐막을 설치하여 상류부 수위를 안정시킨 상태에서 실험을 수행하였고, 차폐막으로부터 하류방향으로 약 7 m(측정기준지점), 11 m, 13 m, 15 m, 17 m 떨어진 곳에서 각각 수위와 유속을 측정하였다. 실험 결과, φ150관은 직경대비 수심이 클수록 조도계수가 감소하는 경향이 나타났고, φ800관은 직경대비 수심의 변화에 따른 조도계수의 경향이 크게 드러나지 않았다. 결론적으로 PE관의 조도계수는 수심별로 변화하는 것으로 나타났으며, 특정 수심을 지나면 조도계수가 다시 감소할 것으로 판단된다.

  • PDF

Numerical Analysis of Nonlinear Thermoelastic Stress for Rectangular Thin Plate (사각형 박판의 비선형 열탄성 응력 수치해석)

  • Kim Chi-Kyung;Kim Sung-Jung
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.155-160
    • /
    • 2004
  • A simply supported rectangular thin plate with temperature distribution varying over the thickness is analyzed. Since the thermal deflections are large compared to the plate thickness during bending and membrane stresses are developed md as such a nonlinear stress analysis is necessary. For the geometrically nonlinear, large deflection behavior of the plate, the classical von Karman equations are used. These equations are solved numerically by using the finite difference method. An iterative technique is employed to solve these quasi-linear algebraic equations. The results obtained from the suggested method are presented and discussed.

A Study on PVD coating technology for Metallic Bipolar Plate Forming Mold (연료전지용 금속분리판 성형 금형 장수명화 코팅 기술 연구)

  • Kim, Eun-Yeong;Jeon, Yu-Taek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.166-166
    • /
    • 2011
  • 연료전지 핵심 부품 가운데 하나인 분리판(Bipolar plate)는 막전극체(MEA), 기체확산층(GDL)과 함께 발생한 전류의 수집 및 전달, 반응 가스의 수송, 반응/생성물의 수송 및 제거, 반응열 제거 등을 위한 냉각수 전달 등의 다양한 역할을 담당한다. 이러한 역할을 위하여 분리판은 우수한 전기전도성, 열전도성, 화학적 안정성이 요구되어 진다. 기존의 연료전지용 분리판은 흑연계 소재 및 수지와 흑연을 혼합한 복합 흑연 재료를 통해 제조하여 요구 되어지는 물성을 만족시켜 왔으나 흑연계 분리판의 경우 강도 및 가스 밀폐성 측면에서 낮은 특성을 보이며 특히 고가의 제조 공정 비용과 낮은 양산성으로 인하여 자동차 연료전지 상용화에 수많은 해결 과제를 안고 있었다. 흑연계 분리판의 이러한 문제점을 대체하기 위한 연구로 최근 금속계 분리판의 적용 및 개발이 활발하게 진행되고 있다. 특히 금속계 분리판은 양산 제조 공정이 적용 가능하여 대량생산이 가능하며 자동차 연료전지 스택의 경량화 및 박판화가 가능하다는 장점을 가지고 있다. 그러나, 박판의 스테인리스강을 소재로 적용한 금속분리판의 양산을 위하여 반드시 선행되어야 할 연구가 바로 금형 코팅 연구이다. 일반 자동차 생산 금형을 평균 약 50만타로 예측한다면 연료전지 금속계 분리판 성형 금형의 현재 수명은 약 10만타로 추정 가능하다. 이러한 원인은 고하중의 프레스 사용과 정밀 금형으로 인한 극한 공정 조건으로 야기된 결과이며 문제 해결을 위하여 성형 금형에 PVD 코팅 적용 연구를 진행하였다. 성형 금형의 PVD 코팅 적용을 통하여 금형 교체 주기 감소를 통한 생산 원가 절감 및 이형성 개선을 통한 성형성 확보를 목표로 본 연구를 진행하였다.

  • PDF

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Seismic Responses Control of Coupled Shear Wall Structures Using LRBs (LRB를 이용한 병렬전단벽 구조물의 지진응답제어)

  • Park, Yong-Koo;Kim, Hyun-Su;Ko, Hyun;Kim, Min-Gyun;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.1-9
    • /
    • 2010
  • Most of shear wall structures require openings in shear walls and thus shear walls are linked by floor slabs or coupling beams resulting in the coupled shear wall structures. When these structures are subjected to seismic excitations, excessive shear forces are induced in coupling beams. Accordingly, brittle failure of coupling beams may occur or shear walls may yield first. To avoid this problem, damping devices can be installed in coupling beams. It can increase the vibration control effect and improve the seismic resistance performance of the coupled shear wall structure by avoiding stress concentration and the brittle failure of coupling beams. Based on this background research, an LRB (lead rubber bearing) was introduced in the middle of the coupling beam in this study and the authors investigated the seismic response control effect and stress distribution of the proposed system. To this end, a modeling technique that can effectively predict the structural behavior of coupled shear wall structures has been proposed. With this proposed technique, time history analyses of the example coupled shear wall structure subjected to seismic excitation were performed and the vibration control effects of the seismic responses were investigated.

Measurement of Tensile Properties for Thin Aluminium Film by Using White Light Interferometer (백색광간섭계를 이용한 알루미늄 박막의 인장 물성 측정)

  • Kim, Sang-Kyo;Oh, Chung-Seog;Lee, Hak-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 2010
  • Thin films play an important role in many technological applications including microelectronic devices, magnetic storage media, MEMS and surface coatings. It is well known that a thin film's material properties can be very different from the corresponding bulk properties and thus there has been a strong need for the development of a reliable test method to measure the mechanical properties of a thin film. We have developed an alternative and convenient test method to overcome the limitations of previous membrane deflection experiment and uniaxial tensile test by adopting a white light interferometer having sub-nanometer out-of-plane displacement resolution. The freestanding aluminium specimens are tested to verity the effectiveness of the test method developed and get the tensile properties. The specimens are 0.5 rum wide, $1{\mu}m$ thick and fabricated through MEMS processes including sputtering. 1 to 5 specimens are fabricated on Si dies. The membrane deflection experiments are carried out by using a homemade tester consisted of a motor-driven loading tip, a load cell, and 6 DOF alignment stages. The test system is compact enough to set it up beneath a commercial white light interferometric microscope. The white light fringes are utilized to align a specimen with the tester. The Young's modulus and yield point stress of the aluminium film are 62 GPa and 247 MPa, respectively.

Preparation of Superflux Nickel Capillary Support with 3D Macropore Channel Network For Gas Separation and Liquid Filtration Membranes (기체/액체 분리막을 위한 3차원 Macropore 채널을 갖는 Superflux 니켈 모세관 지지체의 제조)

  • Song, Ju-Seob;Cho, Churl-Hee
    • Membrane Journal
    • /
    • v.28 no.3
    • /
    • pp.214-219
    • /
    • 2018
  • In the present study, superflux nickel capillary supports for gas and vapor separation membranes were prepared by a combined process of NIPS and sintering. Nickel capillary precursors were prepared by NIPS process from PSf-Ni-DMAC-PEG400 dope solution and was sintered at various temperatures in $H_2$ atmosphere to reliably produce Ni capillary support. The optimized Ni capillary support has an outer and inner diameters of 722 and $550{\mu}m$, and its thickness was $94{\mu}m$. It has 3-dimensional pore channel network and its porosity and mean pore diameter was 26% and $4{\mu}m$, respectively. Also, its mechanical strength was tested in tensile mode: its fracture load was 2.84 kgf and the fracture elongation was 13%. Finally, its single gas permeance was measured: He, $N_2$, $O_2$, and $CO_2$ permeance was 432,327, 281,119, 264,259, and 193,143 GPU, respectively. The superflux behavior could be explained from viscous flow through the macropores having a diameter of $4{\mu}m$ and narrow thickness. It could be concluded that the superflux behavior of the Ni capillary support was from the 3-D pore channel network and the small thickness.

Study on Vibration Induced by Fluid at a Water Pressure Reducing Valve through Structure-Fluid Coupled Analysis (구조-유체 연성해석을 통한 수도용 감압밸브에서의 유체유발진동에 관한 연구)

  • Park, Woo-Cheul;Lee, Joong-Kuen;Kim, Il-Gyoum;Park, Yong-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4371-4377
    • /
    • 2012
  • In this paper, the structure-fluid coupled analysis is carried out in order to examine the cause of the vibration induced by fluid in the pressure-reducing valves for water. It is confirmed that there is the noise at the area of low frequency of 250Hz by measuring noise at pressure reducing valve. The flow analysis is performed by the commercial software ANSYS/CFX. The flow velocity of about 40 m/s is formed by nozzle effect, and so negative pressure is happened in the pressure reducing valve. The structure analysis is carried out with the load condition of pressure distribution by flow formed in valve. The rubber material at disk is deformed to the extent of closing up flow passage. It is confirmed that the disc deformation which is occurred repeatedly is due to noise and vibration at the pressure reducing valve.