Development of Sewage Treatment Apparatus for Detached House in Agricultural Village by Natural Purification Method (자연정화공법에 의한 농촌 전원 독립가구 하수처리장치 개발)

  • Seo, Dong-Cheol;Park, Mi-Ryoung;Kim, Hyung-Jun;Cho, In-Jae;Lee, Hong-Jae;Sung, Sun-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.202-210
    • /
    • 2006
  • To develop small-scale sewage treatment apparatus for detached house of agricultural village, a small-scale sewage treatment apparatus by natural purification method that consisted of packaged form of aerobic, anoxic and anaerobic bed was constructed. The efficiency of sewage treatment according to the sewage treatment method, sewage loading, and the injection method of sewage were investigated for small-scale sewage treatment apparatus of packaged form of aerobic, anoxic and anaerobic bed. The removal rate of pollutants according to the sewage treatment method for small-scale sewage treatment apparatus was high in the order of aerobic-anoxic-anoxic bed < aerobic-anoxic-anaerobic bed. The optimum filter media in small-scale sewage treatment apparatus was a broken stone. The removal rate of pollutants according to sewage loading in small-scale sewage treatment apparatus was high in the order of $1,200L/m^2{\cdot}day\fallingdotseq900L/m^2{\cdot}day\fallingdotseq600L/m^2{\cdot}day$. The removal rate of pollutants according to injection method of sewage in small-scale sewage treatment apparatus was high in the order of continuous injection $\fallingdotseq$ intermittent injection. When loaded under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P were 99, 95, 99, 83 and 96%, respectively, through this 3-stepped small-scale treatment apparatus arrayed with the order of aerobic, anoxic and anaerobic bed.

Analysis on Nitrogen Faction of Influent Sewage in Domestic STP Based on Long-term Incubation Method (장기 배양법을 이용한 국내 하수처리장 유입 하수의 질소 성상 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.2
    • /
    • pp.216-222
    • /
    • 2017
  • Recently, opinions on the need for revision regarding the nitrogen effluent standard of nitrogen from sewage treatment plant(STP) are consistently suggested. However, it is axiomatic that if nitrogen effluent standard is strengthened without a clear basis, it will cause confusion in domestic STP. In this research, nitrogen fraction was analyzed based on a long-term incubation method, according to STP capacity, and the linked treatment of industrial wastewater. As a result, NBDDON, which is difficult to treat in STP, ranged from 1.0 to 1.9 mg/L. larger DON and NBDDON/DON was detected in small STP (under 10,000 m3 /d) as opposed to the large STP. NBDDON/DON in industrial STP was about 0.7 and it was higher than municipal STP. This research result will be used in the important raw data for revision of nitrogen effluent standard of nitrogen from STP.

Study on the Operation and Status of Private Sewage Treatment Facilities (개인하수처리시설 운영 및 실태 연구)

  • Lee, Jang-Hown;SHIN, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.2
    • /
    • pp.31-40
    • /
    • 2020
  • As private sewage treatment facilities in Korea are constantly concerned about the distribution and poor construction of defective products, minimum standards for each unit process applicable to the planning and design of sewage treatment facilities are deemed necessary. The problems and requirements of the analysis results of the operation status discussed in this study are as follows. 1) Strengthening education of supervisor of private sewage treatment facility. 2) Poor operation and management of Sewage treatment facilities. 3) A mandatory review of sewage treatment facilities for less than 2 ㎥/day of facilities other than sewage treatment zones. 4) Necessity of management of sewage treatment facility in feedstocks. 5) As a result of the technical review, Improvement plans for Ineligible facility are needed. It is also necessary to prepare a guidebook for design construction and maintenance by investigating and analyzing guidelines and data related to domestic and foreign private sewage treatment facilities.

Comparison of Removal Efficiencies in Single and Duplex Ventilation Constructed Wetland Systems for Treating Domestic Sewage (단일 통풍형과 이중 통풍형 인공습지시스템의 하수처리 효율 비교)

  • Seo, Dong-Cheol;Lim, Seok-Cheon;Jo, In-Seong;Lee, Byeong-Ju;Lee, Hong-Jae;Kim, Sang-Don;Lee, Jun-Bae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.3
    • /
    • pp.258-265
    • /
    • 2009
  • To develop environmentally friendly constructed wetlands(CWs) for treating domestic sewage which was produced in farming and fishing village, the efficiency of water treatment at different ventilation systems in the vertical bed, depths of horizontal bed, and sewage loads was investigated. In the vertical bed, BOD and COD by duplex ventilation system were lower than those by single ventilation system. But T-N and T-P concentrations by both ventilation systems in the vertical bed were little different. In the horizontal bed, BOD, COD, T-N and T-P in 1.0 m and 1.3 m depths were little different. To reduce the CWs' area and to improve the pollutant removal efficiencies, the optimum depth of horizontal bed was 1.3 m. In single and duplex ventilation CWs, the removal rate of BOD, COD, SS, T-N and T-P decreased slightly with the sewage load increases. In same sewage load conditions, the removal rates of BOD, COD, SS, T-N and T-P by duplex ventilation CWs were higher than those by single ventilation CWs. In summary, to effectively treat domestic sewage from farming and fishing village, the optimum constructed wetlands would be the duplex ventilation CWs.

Disposal, recycle and treatments of sewage sludge : a review (하수슬러지 처리 방법에 대한 고찰)

  • Shon, Byung-Hyun;Kwon, Young-Hyun;Jung, Moon-Hun;Lee, Ju-Ho;Kim, Min-Choul;Lee, Gang-Woo;Jung, Jong-Hyeon;Choi, Soo-Kyung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.910-913
    • /
    • 2009
  • 경제성장과 산업도시의 발달로 인해 물의 사용량이 증가함에 따라 하수처리장의 수와 규모가 커지고 있어 하수처리장에서 발생하는 하수슬러지의 양도 지속적으로 증가하고 있다. 런던협약 '96의정서 발효에 따라, 하수슬러지의 해양배출기준이 대폭 강화 되었으며 또한 2012년부터는 하수슬러지의 해양 투기가 전면 금지될 것이므로, 해양투기 등으로 처리되고 있는 하수슬러지를 에너지자원으로 활용하여 고유가 및 기후변화에 적극 대응하고, 런던협약 등에 따른 해양투기 금지('2012)에 대처하기 위해 하수슬러지의 처리 및 재이용 방법에 대한 최근의 연구동향을 고찰해 보았다.

  • PDF

상하수도 정책 - 전국 하수처리시설의 획기적 효율개선 필요

  • 한국상하수도협회
    • 한국상하수도협회지
    • /
    • s.28
    • /
    • pp.26-27
    • /
    • 2009
  • 환경보호와 지속성장을 동시에 가능케 하는 '녹색 성장' 이 산업계의 새로운 화두로 떠오르고 있는 요즘, 하수처리 분야에 이목이 집중되고 있다. 보다 효율적인 하수처리를 통해 수질을 보호하고 경제적 효과를 창출하는 새로운 방안에 기대가 큰 만큼, 이제는 상하수도의 효율적인 기준 마련이 필요하기 때문이다.

  • PDF

Impact Analysis and Prioritization of Wastewater Reuse (안양천유역별 하수처리수 재이용에 대한 효과 분석 및 우선순위 선정 개발)

  • Jun, Sang-Mook;Chung, Eun-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.627-627
    • /
    • 2012
  • 본 연구의 목적은 수문학적 분석과 다기준의사 결정을 사용한 계획 구성을 통한 하수처리수 재이용의 실현성을 보여주는데 있다. 안양천의 10개의 소유역을 대상으로 BOD와 유량에 대한 대안을 세워보았다. BOD는 각 유역에 3.0 mg/L 와 4.7 mg/L로 선정하였고 유량은 각 소유역에 따라 대안을 선정하였다. 대안에 따른 수문학적 분석은 Hydrological Simulation Program in Fortran (HSPF)을 사용하였다. 본 연구에서는 수질이 향상되고 요구되는 유량만킁의 증가가 있다면 하수처리수 재이용이 파괴된 물 순환의 회복에 얼마나 큰 영향을 미치는지에 대해 보여주었다. 추가적으로 대안의 우선순위를 선정하는데 있어서 다음의 세가지 경우을 비교하였다: 1) 물의 유량과 수질의 영향 그리고 2) 현재 나타나고 있는 유량과 수질의 수문학적 취약점에 대한 고려 마지막으로 3) 사회와 경제적인 측면에서 고려하였는지에 대해 비교하였다. 그 결과 세 가지 경우는 매우 다른 순위를 나타냈다. 그러므로 하수처리수 재이용에 대한 다양한 영향에 대한 고려사항은 유의 깊게 선택 되어야 하겠다.

  • PDF

국내.외 하수고도처리공정 개발현황 및 특징분석

  • 안창진;서인석
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.02a
    • /
    • pp.113-197
    • /
    • 2004
  • 우리나라에서는 수질개선을 위하여 하수처리분야에 1993년부터 1997년까지 총 7조 7,705억원을 투자하였으며, 방류수 수질기준 강화 측면에서는 1996년 1월 1일부터 총인(T-P)과 총질소(T-N)의 방류수 수질기준을 수질환경보전법에 명시하여 규제하기 시작하여, 2008년 1월 1일부터 BOD 및 SS 10mg/L, T-N 20mg/L, T-P 2mg/L로 전국적으로 강화할 계획이다. 그러나, 수질개선을 위한 투자액 중 서울 등 대도시의 하수처리시설이나 하수관거 투자액이 절대적으로 많은 부분을 차지하고 있으므로, 상수원수의 뚜렷한 개선효과는 미미한 실정이다. (중략)

  • PDF

Design of High Strength Underground FRP Septic Tank Stiffened by Circular Steel Pipe (원형강관으로 보강된 지중매립형 FRP 개인하수 처리시설의 설계)

  • Cho, Kwang Je;Kim, Sung Bo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.171-181
    • /
    • 2012
  • The design of high strength underground septic tank stiffened by steel pipe is presented and the ultimate behavior is investigated according to the full scale experiments for three types of specimens. The limitation of the current design specification are pointed out and the general design procedure of private sewage treatment facility are newly developed considering thickness of FRP shell, types of steel pipe stiffer and diaphragm wall. The direct tensile and bending test for FRP material of septic tank were performed. The increase effect of ultimate strength due to the circular steel pipe are investigated by the full scale field test and compared with the results by the finite element analysis.

Environmental impact monitoring of indirect wastewater reuse in rice paddy fields (하수처리수의 농업용수 간접재이용에 따른 환경영향)

  • Park, Ji-Hoon;Jeong, Han-Seok;Kang, Moon-Seong;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.759-759
    • /
    • 2012
  • 하수처리수의 농업용수 재이용 사업은 물 재이용 기본계획의 일환으로 수행되고 있다. 재이용방식은 직접재이용과 간접재이용으로 구분할 수 있으며 2020년까지 56개 하수처리시설에서 총 106,388 천$m^3$/년의 농업용수를 직접재이용할 계획이다. 하지만 대부분의 경우 간접재이용의 형식으로 하수처리수를 농업용수로 이용하고 있는 실정이다. 따라서 본 연구의 목적은 하수처리수의 농업용수 간접재이용에 따른 작물생육, 수질, 그리고 토양환경에 미치는 영향을 평가하는데 있다. 본 연구를 위해 수원시 환경사업소와 오산시 환경사업소 하류 지역을 간접재이용 사례지구로 선정하고, 용인 이동저수지를 관개용수로 하는 청정지역을 대비구로 선정하였다. 각 지구별로 수량 구성요소 및 수확량 특성, 그리고 벼의 영양염류 및 중금속 함량 등의 유해성분을 분석하였으며, 관개수질과 논토양의 성분을 모니터링 하였다. 모니터링 결과를 통해 간접재이용 사례지구의 환경영향을 평가하여 수질기준을 정립하고 간접재이용시스템을 개발하는데 있어 기초적인 자료를 제공할 것이라 사료된다.

  • PDF