• Title/Summary/Keyword: 하수처리장 모델

Search Result 58, Processing Time 0.025 seconds

Forecast of Influent Characteristics in Wastewater Treatment Plant with Time Series Model (시계열모델을 이용한 하수처리장 유입수 성상 예측)

  • Kim, Byung-Goon;Moon, Yong-Taik;Kim, Hong-Suck;Kim, Jong-Rack
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.701-707
    • /
    • 2007
  • The information on the incoming load to wastewater treatment plants is not often available to apply to evaluate effects of control actions on the field plant. In this study, a time series model was developed to forecast influent flow rate, BOD, COD, SS, TN and TP concentrations using field operating data. The developed time series model could predict 1 day ahead forecasting results accurately. The coefficient of determination between measured data and 1 day ahead forecasting results has a range from 0.8898 to 0.9971. So, the corelation is relatively high. We made forecasting program based on the time series model developed and hope that the program will assist the operators in the stable operation in wastewater treatment plants.

Water Quality Model Constitution using Water Quality-Stage Network Data of the Young-san River Basin (영산강 유역의 관측망 자료를 활용한 수질모델 구축)

  • Park, Sung-Chun;Oh, Chang-Ryol;Jin, Young-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1338-1342
    • /
    • 2005
  • 최근에 하천수질이 악화되고 물 수요량이 증대됨에 따라 사회적으로 하천의 유지관리문제가 중요시되고 있는 실정이다. 보다 효율적인 수질관리를 위해서 수질모델을 이용하여 장래 수질예측결과를 토대로 수질보전 대책 및 오염원 저감 계획을 수립하여야 하는데, 이러한 수질모델의 구성을 위해서는 장기간의 수질 및 유량측정자료의 구축이 선행되어져야하므로 시간적$\cdot$경제적인 어려움이 따르게 된다. 이에 본 연구에서는 영산강을 대상유역으로 선정하고, 영산강 유역 환경청과 영산강 홍수통제소에서 운영$\cdot$관리하는 관측망 자료인 수질자료와 수위자료를 이용하여 수질모델을 구축하고, 장래 수질예측을 실시하였다. 수질예측결과 영산강은 광주하수종말처리장 방류수의 수질농도가 지대한 영향을 미치는 것으로 판단되어 광주하수종말처리장 처리효율에 따른 수질변화를 모의하였다.

  • PDF

A Tracer Study on Mankyeong River Using Effluents from a Sewage Treatment Plant (하수처리장 방류수를 이용한 추적자 시험: 만경강 유역에 대한 사례 연구)

  • Kim Jin-Sam;Kim Kang-Joo;Hahn Chan;Hwang Gab-Soo;Park Sung-Min;Lee Sang-Ho;Oh Chang-Whan;Park Eun-Gyu
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.11 no.2
    • /
    • pp.82-91
    • /
    • 2006
  • We investigated the possibility of using effluents from a municipal sewage treatment plant (STP) as tracers a tracer for hydrologic studies of rivers. The possibility was checked in a 12-km long reach downstream of Jeonju Municipal Sewage Treatment Plant (JSTP). Time-series monitoring of the water chemistry reveals that chemical compositions of the effluent from the JSTP are fluctuating within a relatively wide range during the sampling period. In addition, the signals from the plant were observed at the downstream stations consecutively with increasing time lags, especially in concentrations of the conservative chemical parameters (concentrations f3r chloride and sulfate, total concentration of major cations, and electric conductivity). Based on this observation, we could estimate the stream flow (Q), velocity (v), and dispersion coefficient (D). A 1-D nonreactive solute-transport model with automated optimization schemes was used for this study. The values of Q, v, and D estimated from this study varied from 6.4 to $9.0m^3/sec$ (at the downstream end of the reach), from 0.06 to 0.10 m/sec, and from 0.7 to $6.4m^2/sec$, respectively. The results show that the effluent from a large-scaled municipal STP frequently provides good, multiple natural tracers far hydrologic studies.

Evaluation of Operational Options of Wastewater Treatment Using EQPS Models (EQPS 모델을 이용한 하수처리장 운전 평가)

  • Yoo, Hosik;Ahn, Seyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.401-408
    • /
    • 2018
  • EQPS (Effluent Quality Prediction System, Dynamita, France) was applied to analyze the appropriateness of the design of a bioreactor in A sewage treatment plant. A sewage treatment plant was designed by setting the design concentration of the secondary clarifier effluent to total nitrogen and total phosphorus, 10 mg/L and 1.8 mg/L, respectively, in order to comply with the target water quality at the level of the hydrophilic water. The retention time of the 4-stage BNR reactor was 9.6 hours, which was 0.5 for the pre-anoxic tank, 1.0 for the anaerobic tank, 2.9 for the anoxic tank, and 5.2 hours for the aerobic tank. As a result of the modeling of the winter season, the retention time of the anaerobic tank was increased by 0.2 hours in order to satisfy the target water quality of the hydrophilic water level. The default coefficients of the one step nitrification denitrification model proposed by the software manufacturer were used to exclude distortion of the modeling results. Since the process modeling generally presents optimal conditions, the retention time of the 4-stage BNR should be increased to 9.8 hours considering the bioreactor margin. The accurate use of process modeling in the design stage of the sewage treatment plant is a way to ensure the stability of the treatment performance and efficiency after construction of the sewage treatment plant.

Assessment of Removal of Silver Nanoparticle in Sewage Treatment Plant Waste Using Process Simulation (공정 모사를 통한 하수처리장 내 은나노물질 제거 평가)

  • Oh, Seung Yeon;Kim, Younghun
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.160-165
    • /
    • 2014
  • Over the past decade, an increasing number of manufactured nanoparticles (NPs) have been incorporated into products and manufacturing processes due to the rapid innovation and commercialization in the field of nanotechnology. In addition, these nanomaterials and nano-consumer products have increased in quantity per year, and thus their uncontrolled release into the environment is anticipated to grow dramatically in future. However, A current sewage/wastewater treatment plant (SWTP) is being applied to removal of nanoparticles in wastewater. In Korea, the study on the removal of nanoparticles in SWTP was not reported yet. Therefore, in this work, to design pilot STP before field test, two model equations and commercial process simulation were used to derive the desing parameters.

Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling (모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구)

  • Lee, Hyunseop;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.251-256
    • /
    • 2019
  • In the upstream and nearby areas of the water source, there are many areas where the sewerage penetration rate is relatively low due to development restrictions. This has been continuously affecting the pollution of the water source. As a measure to prevent this, method of distributing sewage and improving existing facilities are suggested. In this study, A MWTP(Municipal Watewater Treatment Plant) using the Air-vent SBR process located at upstream of An-dong and Im-ha Dam was selected as a modeling facility. And, the retrofit method to improve the effluent from RCSTP(Rural Community Sewage Tratment Plant) was induced based on A MWTP modeling result. The model construction and verification were carried out based on the operating data for 5 years (2012 ~ 2016). As a result, it was analyzed that the water quality of the effluent during the winter could be improved through control of cycle time in Air-vent SBR process and decreasing SRT (BOD: 1.8%, COD: 54.5%, SS: 4.3%, T-N; 0.8% and T-P: 7.7%). This research suggests that result of this research can be utilized as a retrofit method to improve the effluent overall treatment efficiency of the MWTP and the RCSTP which have similar operation process.

Feasibility Study of small hydropower at a municipal wastewater treatment plant by model analysis (모델분석을 통한 하수처리장 소수력발전 경제성 평가)

  • Kim, Won-Kyoung;Kim, Dong-Soo;Kang, Ji-Hoon;Chae, Kyu-Jung;Kim, Jung-Yeon;Lee, Chul-Hyung;Park, Wan-Soon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.216-220
    • /
    • 2012
  • 본 연구는 경기도 용인시에 위치한 공공하수처리장을 대상으로 소수력발전 성능특성을 예측하고 경제성을 분석하여 소수력발전소의 건설타당성을 제시하였다. 방류구에서의 수준측량 조사에 따르면 실제 유효 낙차는 4.3m로 나타났다. 최근 5년간 방류량 자료를 살펴보면 일평균 실제 처리량은 약 $30,000m^3/day$로 나타났으며, 우수 유입과 물 사용량이 증가하는 여름 및 가을에 처리량이 증가하였다. 설계유량은 유량변화에 따른 누적 확률밀도와 유량지속곡선에 근거해 산정하였으며, 시간빈도로 보았을 때 17%의 유량이 지속되는 $0.35m^3/sec$가 설계유량으로 나타났다. 예상되는 수차 발전용량은 11kW급이며, 시스템 가동율은 74%, 그리고 계통선에 송출될 수 있는 연 전력생산량은 71.3MWh로 나타났다. 경제성 평가는 신재생에너지 경제성 분석 도구인 RETScreen 프로그램을 사용하여 B/C ratio, IRR, 개발투자비 등의 경제성 평가지표들을 산정하였다. 편익(Benefit) 산정시 전력기준단가는 133.67원/kWh, 할인율 7%를 적용하였으며, 비용(Cost) 산정시 유지관리비는 초기 건설비의 1%, 사용연한 30년을 적용하였다. 경제성 분석결과 기흥레스피아의 소수력발전소 건설시 초기 건설공사비가 $165,000 일 때, B/C 1.0, NPV $3,534, 투자회수기간 15.1년으로 산정되었고 따라서 초기 건설비용이 $165,000 이하일 때 가장 경제적인 것으로 파악되었다.

  • PDF

Analysis of COD fraction and change of COD in nitritation reactor using various wastewater (다양한 하수를 대상으로 유기물 성상과 질산화 반응조 내 유기물 변화)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.421-427
    • /
    • 2015
  • In ASM model, organic matters are classified according to their characteristics and general classification into COD and BOD cannot satisfy conditions required by ASM. In this study, it was performed to study classification of organic matters required by ASM on the basis of microorganisms' respiration rate subject to wastewater and sludge treatment. As results of analysis of the organic matter's appearance, it was found that there were some differences in composition of organic matters between wastewaters. It is considered that it is an important characteristic of wastewater that should be understood in treating wastewater in each process. Therefore, it is considered that appearance of organic matters in each wastewater identified by this study will be used as important basic data for operation of municipal wastewater treatment plant. It was identified that SS was an important factor affecting nitrification through organic matter and ammonium nitrogen change analysis according to reaction time in the nitrification. It is considered that the nitrification has close relationship with choice of optimal retention time.

WEC-Sim: A Simulator for Optimum Management of Wastewater Treatment Plant (WEC-Sim : 하수처리장 최적 운영을 위한 시뮬레이터)

  • Lee, Sung-Koo;Ahn, Sae-Young
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.463-471
    • /
    • 2010
  • In the management of a wastewater treatment plant which is a combination system of physical, chemical, and biological processes, computer simulator is an indispensable part for analysis of the operation status and evaluation of the treatment performance due to its fast computing speed. As an application software carrying out the data input-output operations and the mathematical calculations of the models, simulator is to be a powerful tool for estimating the treatment reaction and calculating mass balance of substrates, microorganisms, and chemicals within the treatment system in a given condition. Qualitative and quantitative prediction of treatment performance provides the plant manager with validity of decision-making through implementing modeling and simulation as a role of knowledge-based expert system in charge of automation and control. This paper shows the proceeding of design and development of the "WEC-Sim" software which is owned the various functions of data acquisition, monitoring, simulation, and control.

Application of QUAL2K Model for Daejeon Tandongcheon, A Small Urban Stream and Evaluation of Terrace Land Constructed Wetland (도시 소하천, 대전 탄동천, 수질개선 대안 수립을 위한 QUAL2K 수질모델 구축과 제외지 인공습지공법 적용 효율 평가)

  • Yin, Zhenhao;Seo, Dongil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.3
    • /
    • pp.192-199
    • /
    • 2013
  • The Tandong-cheon stream is a 7.4 km long small urban stream that passes through Daeduk Science Town in Daejeon Korea. Despite the stream has great potential as an educational and recreational site due to its central location in the science town and science museums nearby, environmental aspect especially for water quality has not been evaluated properly. Through field survey, major pollution sources of the stream were identified and effect of water quality improvement alternatives were evaluated using a QUAL2K water quality model for the stream. The study indicated that controlling major pollution sources of the stream alone may not be sufficient for reaching the water quality target. Therefore, additional pollution control methods are necessary. We applied the developed model to evaluate the effects of a constructed wetland on the terrace land, and analyzed whether the water quality target can be met at the outlet of the stream. It is expected that this study would provide a good reference for environmentally sound management of small urban streams in Korea.