• Title/Summary/Keyword: 하부구조 강성

Search Result 128, Processing Time 0.026 seconds

Experimental Study on Natural Period for Arch Structure with Column (하부기둥에 따른 아치구조물의 고유주기 변화에 관한 실험적 연구)

  • Kang, Joo-Won;Seok, Keun-Yung;Lee, Sang-Hoon;Kim, Gee-Cheol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.2
    • /
    • pp.83-90
    • /
    • 2009
  • The previous studies for dynamic behavior of spatial structure have been zoomed in on roof structure by numerical analytic method. But the roof structure of real spatial structures is supported by lower structure as column and wall. So, when earthquake is occurred, it is predicted that dynamic behavior of roof structure is affected by lower structure. Therefore, on this study, natural period characteristics of arch structures are analyzed according to section, length and the modulus of elasticity of brass column and polycarbonate column and additional mass of roof structure by the scale-down model of arch structure as the most simple structure of spatial structures. The changes of natural periods are generally alike. But, when Polycarbonate column is connected to roof structure, the change of natural period for change of section is relatively large. That means that change of section and section and length of column and additional mass of roof structure have less influence on change of stiffness because the modulus of elasticity of brass is relatively large.

  • PDF

Seismic Response of Arch Structure according to the Aspect Ratio and Columns (아치구조물의 형상비와 하부구조에 따른 지진응답특성에 관한 연구)

  • Seok, Keun-Young;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.3
    • /
    • pp.71-78
    • /
    • 2012
  • The dynamic behavior of spatial structures is different depending on the aspect ration of arch structure, as the rise-span ratio or open-angle, and these spatial structures show differently the character of seismic response in accordance with stiffness and connection of the lower support structures that are directly influenced by earthquake. Therefore, in this paper, dynamic analysis is conducted for seismic response of single layer arch structures by the influence of column's stiffness and connection, to reflect the different vertical and horizontal vibration mode of single layer arch structures. The vertical response of single layer arch structures is more influence by lower columns and the influence of column's connection rotational stiffness is not large, except to the hinged connections.

Study on the Equation of Natural Period of Middle and Low Rise Building of Upper-Walled Lower Frame Type (중저층 상부벽식 하부골조 구조의 고유주기 산정식에 관한 연구)

  • Yoo, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.60-67
    • /
    • 2021
  • According to the 「Guidelines of Structural Design for Piloti Building」 of the Ministry of Land, Infrastructure and Transport (2018), the natural period of middle and low rise building of upper-walled lower frame type, such as the domestic multiplex house in piloti style, is suggested for safety to apply the existing code formula of the wall structure. However, the current code formula of the wall structure was provided based on actual measurement of high-rise wall-type structures that mainly exhibit bending behavior. So it is considered that it is not suitable for a piloti-type house with four stories or less, where the wall behaves in shear. See also Park et al. (2000) confirmed that the effect of the lower frame part is greater than that of the upper wall part in the natural period of complex structures with 10 or more floors through analytical studies. Therefore, in this study, in order to examine the effect of the lower frame on the natural period of the middle and low-rise piloti structure, the estimation of natural period by the finite element analysis, approximation formula and ccurrent code formula was performed for the target structures with the shear and flexural stiffness of the upper wall and the shear stiffness of the lower frame as variables. As result, it was found that the change in the shear stiffness of the lower frame had a greater effect on the natural period of the whole building than the change in the bending or shear stiffness of the upper wall.

Seismic Behavior of the Spacial Structure with Seismic Isolation (면진장치를 적용한 대공간구조물의 지진응답 분석)

  • Kim, Gee-Cheol;Ju, Dong-Hyem
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.49-57
    • /
    • 2008
  • The seismic isolation systems could be used to reduce the seismic response of a structure. The natural period of a structure with seismic isolation system got be long to avoid the prominent seismic period. The purpose of this study is to analyzed the seismic behavior of the truss arch that is supported to column with LRB. Truss arch structures subjected to horizontal seismic have large horizontal and vertical response unlike seismic behavior of normal rahmen structures. When seismic load is applied to the truss arch with isolation systems, the horizontal acceleration response of the truss arch is reduced and the vertical seismic response is remarkably reduced. Also, the seismic behaviors of the truss arch with strengthen column as like lattice column are very similar to that of the truss arch supported to directly foundation. The Seismic Isolation system can be applied to reduce efficiently the seismic response of the spacial structure with not strong column.

  • PDF

Design of a Steel Structural Building Using Double Split Tee Connections without Shear Tabs (전단탭이 없는 상·하부 스플릿 티 접합부를 적용한 강구조물의 설계)

  • Yang, Jae Guen;Kim, Yong Boem
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.85-96
    • /
    • 2016
  • Double split tee connection has various strength, stiffness, and energy dissipation capacity according to changes of thickness of T-stub flange and gauge distance, number, and diameter of high-strength bolt. If the double split tee connection is applied to a low- or medium-rise steel structure, a shear tab can't be applied for supporting shear force because of geometrical limitation. So it is required to propose details of improved double split tee connection to support shear force as well as flexural force. This research was performed to see if enough rotational stiffness is found when the double split tee connection without shear tab which was obtained through analytic and experimental researches by Yang et al. is applied to a low- or medium-rise steel structure. Also, it was seen if the low- or medium-rise steel structure having double split tee connection without shear tab has safe structural behavior, as well as material saving effect.

Joint Stiffness Evaluation in Jointed Plain Concrete Pavement (줄눈 콘크리트 포장의 줄눈강성 산정 연구)

  • Chon, Beom Jun;Lee, Seung Woo;Kwon, Soon-Min;Kim, Seong-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1D
    • /
    • pp.49-54
    • /
    • 2009
  • The excellent load transfer at transverse joints ensures the high performance of jointed plane concrete pavements(JPCP). Load transfer efficiency(LTE) is affected by dowel-bars, aggregate interlock and types of underlying layers, and these factors have to be modelled adequately for a reasonable analysis of JPCP. Generally, the joint stiffness has been represented by a spring model for the shear transfer by aggregate interlock or dowels. However dowel-bars, aggregate interlock and types of underlying layers have not been considered together in the design of joints. In this study, the joint stiffness that considered those factors was presented by comparing LTE obtained using FWD(Falling Weight Deflectometer) with theoretical results obtained using the finite element analysis. In addition, the effects of temperature and concrete age, on the joint stiffness were investigated.

Earthquake Resistance Design for a Typical Bridge Substructure (일반교량 하부구조의 내진설계)

  • Kook, Seung-Kyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.283-288
    • /
    • 2011
  • For the earthquake resistance design designer should provide that structural yielding process is principally designed with the ductile failure mechanism. In order to get the ductile failure mechanism for typical bridges, pier columns yielding should occur before that of connections. However domestic bridge design with unnecessary stiff substructure leads to unnecessary seismic loads and makes it difficult to get the ductile failure mechanism. Such a problem arises from the situation that earthquake resistant design is not carried out in the preliminary design step. In this study a typical bridge is selected as an analysis bridge and design strengths for connections and pier columns are determined in the preliminary design step by carrying out earthquake resistant design. It is shown through this procedure that it is possible to get the ductile failure mechanism with structural members determined by other design.

Comparative Seismic Design of Bridges with Lead Rubber and Steel Bearings for the Ductile Failure Mechanism (지진격리교량과 강재받침교량의 연성파괴메커니즘에 의한 비교내진설계)

  • Kook, Seung Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.173-181
    • /
    • 2006
  • Many isolated bridges are designed and constructed after the introduction of the seismic design. However those bridges designed in engineering fields have unnecessarily high serviceability limit and brittle failure mechanism, which do not satisfy the seismic design concept. Such design results are due to the excessive substructure stiffness of the conventional design method as well as the misunderstanding of the seismic design method. In this study an isolated bridge designed with the conventional design method is selected and the same bridge with steel bearings is modelled for the comparative seismic design. From the comparison, the seismic design procedures satisfying the required performance levels are provided for the two bridges. It is confirmed that the isolated bridge requires more complicated design procedure with trial and error methods and reanalyses but provides higher serviceability limit compared to the bridge with steel bearings. However, because the required serviceability limit can also be obtained by adjusting substructure stiffness, it is a resonable seismic design process that an isolated bridge is to be considered as an alternative design when the ductile failure mechanism is not obtained with a bridge with steel bearings.

Evaluation of the Initial Rotational Stiffness of a Double Split Tee Connection (상·하부 T-stub 접합부의 초기회전강성 평가)

  • Kim, Hee Dong;Yang, Jae Guen;Lee, Jae Yun;Lee, Hyung Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.2
    • /
    • pp.133-142
    • /
    • 2014
  • Double split tee connection is a full strength-partial restrained connection that suitable for ordinary moment frame and special moment frame which demonstrates behavior characteristics depending on the stiffness ratio of columns and beams, changes in the geometric shape of the T-stub, number of fasteners and effect of panel zone. For the double split tee connection to ensure structurally safe behavior, it needs to exhibit sufficient strength, stiffness and ductile capacity. This study sought to investigate the effects of the moment-rotation angle relationship of the double split tee connection and to evaluate the initial rotational stiffness of the double split tee connection depending on changes in the geometric shape of the T-stub. To this end, two different double split tee connection specimens are experimented which designed to change geometric parameter values (${\alpha}^{\prime}$) of the T-stub, and a three-dimensional finite element analysis was performed.

Prediction Model for the Initial Rotational Stiffness of a Double Split T Connection (상·하부 스플릿 T 접합부의 초기회전강성 예측모델)

  • Yang, Jae-Guen;Kim, Yun;Park, Jae-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.279-287
    • /
    • 2012
  • A double split tee connection is used as a connection that is suitable for ordinary moment frames or special moment frames according to the combination of variables of the thickness of the T-stub flange and the gauge distance of the high-strength bolts. In order to demonstrate safe structural behavior, a double split tee connection must meet the requirements for inter-story drift angles and the moment of connection, as defined in the Korea Building Code-Structural. In order to determine whether the these requirements are met, it is necessary to predict rotational stiffness and the ultimate plastic moment of the connection. Therefore, this study primarily aimed to propose an analytical model for predicting the rotational stiffness of a double split tee connection under a static load. Toward this end, a three-dimensional, non-linear finite element analysis was carried out. Then, the applicability of the proposed model was verified after comparing the test results of this study with other studies.