• Title/Summary/Keyword: 핀 튜브 증발기

Search Result 13, Processing Time 0.023 seconds

Study on Performance Characteristics of Spiral Fin-Tube Evaporator Applied to Domestic Refrigerator-Freezers (나선형 핀-튜브 증발기를 적용한 냉장고의 성능 특성에 관한 연구)

  • Lee, Sang Hun;Yoon, Won Jae;Kim, Yongchan;Lee, Mooyeon;Yun, Seongjung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.205-212
    • /
    • 2013
  • The objective of this study was to investigate the feasibility of replacing a conventional plate fin-tube evaporator with a spiral fin-tube evaporator by comparing the performance of domestic refrigerator-freezers adopting either the plate fin-tube evaporator or spiral fin-tube evaporator. Experiments were conducted for the domestic refrigerator-freezers using either a 2-column and 15-row plate fin-tube evaporator or three spiral fin-tube evaporators with 11, 13, and 15 tube rows (N). The optimum refrigerant charge decreased with a decrease in the number of tube rows. The power consumptions of the domestic refrigerator-freezers using the spiral fin-tube evaporators with N = 11 and 13 were 2.8% and 1.5% lower than those using the plate fin-tube evaporator, respectively. In addition, the cooling capacity of the spiral fin-tube evaporator with N = 13 was 3%-7% higher than that of the plate fin-tube evaporator under the frosting condition. In a cooling speed test, all of the evaporators showed similar performances.

Analytical Study on the Heat Transfer Characteristics of a Spirally Coiled Circular Fin-Tube Evaporator Operated Under Non-Frosting Conditions (무착상 조건에서 나선형 원형핀-튜브 증발기의 열전달 성능에 관한 해석적 연구)

  • Lee, Moo-Yeon;Kang, Tae-Hyung;Kim, Yong-Chan;Park, Jae-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.105-112
    • /
    • 2011
  • The objective of this study is to predict the heat-transfer performance of a spirally coiled circular fin-tube evaporator in which either R134a or R600a was used; this heat-transfer performance was predicted by varying the mass flow rate, inlet air temperature, air flow rate, and tube thickness. Mean deviation for the analytical model from the measured data was ${\pm}8.3%$. Simulation results revealed that at a given mass flow rate, the heat-transfer rate of the evaporator using R600a was higher than that usingR134a because the enthalpy of the former is higher than that of the latter at the given conditions. The heat-transfer rate of both refrigerants increased with an increase in the air flow rate and inlet air temperature but decreased with an increase in the tube thickness.

Research Review for Parametric Characteristics on Heat Exchanger (열교환기 성능에 영향을 미치는 인자들의 특성과 연구동향)

  • 이동진;윤점열
    • Journal of the KSME
    • /
    • v.33 no.11
    • /
    • pp.936-941
    • /
    • 1993
  • 최근 소비전력 구제 및 $CO_{2}$ 발생량 구제 등으로 인하여 에너지 절약형 제품에 대한 요 구가 점증하고있어 핵심부품인 열교환기의 효율 향상은 숙명적인 과제라 할 수 있다. 에어컨에 사용되고 있는 응축기와 증발기(condenser/evaporator)는 대부분이 핀-튜브(fin-tube)형의 직교 류형 열교환기 (crossflow heat exchanger)이다. 이와 같은 열교환기의 성능에 영향을 미치는 인자들은 크게 핀과 튜브로 구성되는 기하학적인 인자와 공기부와 냉매부로 나뉘어지는 물리적인 인자로 나눌 수 있다. 이 글에서는 핀-튜브형 열교환기의 설계시 고려하여야 할 기하학적 인자와 물리적 인자에 대하여 기술하고자 한다.

  • PDF

Frosting Heat Transfer Characteristics of Evaporators Used for Household Refrigerators According to Fin Configuration (냉장고용 증발기의 핀 형상 변화에 따른 착상 열전달 성능특성)

  • Lee, Moo-Yeon;Lee, Sang-Heon;Jung, Hae-Won;Kim, Yong-Chan;Park, Jae-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1071-1078
    • /
    • 2010
  • The objective of this study is to investigate the heat transfer characteristics of evaporators that have various fin configurations and are used in household refrigerators. The frosting and defrosting characteristics of a spirally coiled circular fin-tube evaporator, a discrete-plate fin-tube evaporator, and a continuous-plate fin-tube evaporator were measured and compared. Under non-frosting conditions, the heat transfer coefficient of the spirally coiled circular fin-tube evaporator was 22.3% and 40.2% higher than the coefficients of the discrete- and continuous-plate fin-tube evaporators, respectively. Under frosting conditions, the heat transfer coefficient of the spirally coiled circular fin-tube evaporator was 27.0% and 46.3% higher than the coefficients of the discrete- and continuous-plate fin-tube evaporators, respectively. In addition, the defrosting water amount of the spirally coiled circular fin-tube evaporator was 3.2% and 9.4% lower than the amounts in the case of the discrete- and continuous-plate fin-tube evaporators, respectively.

Heat Transfer Characteristics on Design Conditions of Finned-Tube Evaporators (설계조건에 따른 핀-튜브 증발기의 열전달 특성)

  • 강희정;이윤수;권영철;장근선;김영재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.46-54
    • /
    • 2002
  • To investigate the design effects of a heat exchanger on a tube type, a tube circuit and a fin pitch, an experimental study on the heat transfer characteristics of finned- tube evaporators was performed. The refrigerant was R-22. A refrigerant loop was established to measure the heat transfer rate, the air heat transfer coefficient. The experimental results showed that the heat transfer characteristics of the evaporators were affected by the design parameters. And the heat transfer rate of the slit fin was better about 25%, compared to those of the louver fin. In the present experimental range, the heat transfer performance with the straight tube circuit was more remarkable than that of the zigzag tube circuit, as seen from temperature variations of the evaporator exit. $\jmath$-factor on the tube type, the tube circuit and the fin pinch decreased, as increasing Reynolds number.

Numerical Analysis on the Frosting Performance of a Fin-tube Evaporator for a Refrigerator (냉장고용 핀-튜브 증발기의 착상 성능해석에 관한 연구)

  • Lee, Moo-Yeon;Lee, Ho-Sung;Jang, Yong-Hee;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.307-316
    • /
    • 2008
  • The objective of this study is to provide numerical and experimental data that can be used to investigate the performance characteristics of a flat plate fin-tube evaporator in household and commercial refrigerators under frosting conditions. Computer simulations with variations of operating conditions such as air inlet temperature, relative humidity, and geometries were performed to find out optimal design parameters of a fin-tube evaporator for household and commercial refrigerators. The tube-by-tube method was used in the simulation and the frost growth model was considered under frosting conditions. The developed analytical model predicted the decreasing rates of heat transfer capacity and air flow rate ratio within ${\pm}$10% compared to the experimental results for a refrigerator under real operating conditions. As a result, the frost thickness at $3^{\circ}C$ & 80% is increased 40% than that of $-3^{\circ}C$ & 80%, and the frost thickness at $3^{\circ}C$ & 90% is increased 30% than that of $3^{\circ}C$ & 60%. Accordingly, the operating time of the evaporator in the refrigerator was reduced with the increase of the decreasing rate of air flow rate ratio at each condition.

Heat Exchangers for Refrigeration and Air Conditioning Equipment (냉동공조용 열교환기)

  • 오후규
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.816-828
    • /
    • 1995
  • 냉동공조용 열교환기의 종류, 특징, 기술개발 동향, 전망 등에 대해 요약한 결과를 정리하면 다 음과 같다. (1) 암모니아 냉매가 다시 각광을 받음에 따라 응축기의 형식도 크게 변하고 있다. 이러한 변화로 핀 튜브를 사용한 횡형, 금속용착형 플레이트 식, 플레이트 핀 식의 응축기들이 암모니아 용으로 적용되기 시작하고 있다. (2) 암모니아 냉동장치는 현재에도 많이 적용되고 있으나 대부분 중앙 집중식 천정증발기나 강관 제 유닛 쿨러를 사용하고 있다. 그러나 최근 기술의 발전과 더불어 알루미늄 관 알루미늄 핀 증발기가 개발됨에 따라 암모니아 냉매도 프레온 냉매와 마찬가지로 건식, 분산식으로 적용되게 되었으며 이 분야의 기술개발이 요청된다. (3) 열교환기의 연구 방향은 에너지 절약, 공간 절약에 기여하면서도 성능향상을 이룩할 수 있는 기술개발, 그리고 소음이 적은 기기 제조 기술이 요망된다. 또한, 착상에 대한 기술적 대책, 근 본적 대책에 대한 대비가 요망되며, 기존 냉매에 대한 대체 냉매용 최적 열교환기에 대한 적극적 연구가 요망된다. (4) 제한된 에너지 자원, 지구환경, 열악한 우리나라의 에너지 사정 등을 고려할 때 냉동공조용 열교환기의 성능 향상에 대한 국가와 일반 소비자들의 기대는 더욱 증가하리라 예상된다. 이들 요구를 만족시키기 위해서는 냉동공조용 열교환기의 성능 향상, 열교환기의 제작에 필요한 자 원의 절약, 생산성 향상, 설치장소와 관련한 효율적인 공간활용, 열교환기 자체 소음의 최소화 등의 방면에 착실한 연구 개발이 있어야 할 것이다.

  • PDF

공조기용 열교환기

  • 윤정인
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.10
    • /
    • pp.47-51
    • /
    • 2000
  • 최근 룸에어콘이나 패키지에어콘의 에너지 절약, 쾌척성 등에 대환 사용자나 회사로부터의 요구는 더더욱 높아지고 있다. 공조기의 중요한 구성요소 중 하나인 열교환기도 이러한 요구에 대응하여 기술개발이 계속해서 진행되고 있다. 공조용 열교환기를 설계할 때 가장 중요한 과체는 비용이냐 설치성 등의 제약조건올 만족하면서 필요한 교환열량을 달성하기 위해, 요구되는 열 전달계수(K)와 전열면적(A)의 곱인 KA값을 얼마나 확보하는가 하는 점에 있다. 그러나 이 외의 과제, 예를 들어 홴입력, 소음을 억제하기 위한 공기측 통풍저항의 감소, 증발온도에 영향을 마치는 관내압력손실의 감소 등도 중요한 과제이다. KA값 증대와 통풍저항억제를 동시에 판촉하기 위해 공조용 열교환기는 전면면적을 크게 하고 두께를 작게 하여 사용하는 것이 원칙이다. 또, 전열관의 관경도 관 둘레길이와 냉매분배성능 면에서 제약이 발생한다. 이와 같은 배경으로부터 공조용 열교환기는 판경 6~10 mm정도의 전열 관을 20~25mm길이로 배치한 핀튜브형 열교환기가 주류로 되어있다. 여기에서는 공조기에 널리 사용하고 있는 핀튜브형 열교환기에 대한 최근의 기술개발 사례를 소개하고자 한다.

  • PDF

Theoretical Study on Heat Exchanger Performance of a Fin-tube Evaporator with Frost Growth in a $CO_2$ Refrigerator Truck (이산화탄소 냉매를 이용한 냉동탑차용 핀-관 증발기의 서리성장에 따른 열교환기 성능에 관한 해석적 연구)

  • Myung, Chi-Wook;Cho, Hong-Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.48-54
    • /
    • 2012
  • To analyze the cooling performance of fin-tube evaporator in the refrigerator truck using R744 according to frost growth, the analytical model of evaporator was developed under frost and non-frost conditions. The performance of fin-tube evaporator was investigated with frost thickness and indoor temperature. Besides, the performance of evaporator under frost condition was compared to that under non-frost condition. As a result, area of air passage and system performance were decreased as the frost thickness increased. The cooling capacity was reduced by 10%, 20%, 30% when the frost thickness was 0.7 mm, 1.1 mm, and 1.6 mm respectively. At these conditions, the block ratio was 31%, 48%, and 71%. In addition, the outlet quality of refrigerant was not over 1 when the frost thickness was 1.6 mm in spite of high indoor air temperature.

A study on frost generation and difrosting mechanism on evaporating tubes for Air-conditioning system (냉동공조용 증발기에서 서리의 발생 및 제상 메커니즘에 관한 연구)

  • Jee, Jae-Hoon;Kim, Chang-Bok;Kim, Myung-Hwan;Oh, Cheol
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.166-171
    • /
    • 2005
  • In this experiment study, to acquire elementary data for explaining to generate frost layer in the fin - tube evaporator. the experiment condition is to supply air on 0.3m/s, 0.6m/s, 0.9m/s and inlet air temperature is kept constantly $20^{\circ}C$, supplied air relative humidity is 70%, 80, 90%. And brine temperature in the copper tube was kept $-15^{\circ}C$ because, generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system. in conclusion, through this experiment, we did compare with frost layer and frost quantity in each condition and examine these data

  • PDF