• Title/Summary/Keyword: 피폭 선량

Search Result 1,155, Processing Time 0.024 seconds

Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator (구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성)

  • Lee, Kyung Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.465-471
    • /
    • 2012
  • In this study, three dimensional X-ray dose distribution from dental X-ray generator system was measured by ALOKA PDM-117 dosimeter. The X-ray dose distribution will be change with XCP-DS FIT in oral shot, because the distance between X-ray generator and the dosimeter. The X-ray dose change affects on patient exposure and radiograph image quality. Therefore, it is important to obtain relation between the X-ray dose and the distance. The X-ray dose at the central position was decreased with increasing the distance. Furthermore, the dose at the edge of the X-ray flux was increased with increasing the distance. The increased dose affects on the patient radiation exposure. The present results will provide for good dental radiograph image and reducing radiation over-exposure on patient.

Construction of MIRD-type Korean Adult Male Phantom and Calculation of Dose Conversion Coefficients for Photon (한국 성인남성 MIRD형 모의피폭체 제작 및 광자 외부피폭 선량환산인자 산출)

  • Park, Sang-Hyun;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • MIRD-type Korean adult male phantom, 'KMIRD' was constructed to calculate Korean-specific dosimetric quantities for radiation protection consideration. The external shape of KMIRD was based on national physical standard data of Korean. KMIRD has thicket trunk than MIRD5 and arm models divided from trunk. The height and weight of the KMIRD are 171 cm and 63.8 kg. ICRP23 data were referred to constitute organs and tissues of KMIRD. However nine organs were constructed based on Korean reference data provided by Radiation Health Research Institute. In the present study, the MCNPX2.3 Monte Carlo transport code was combined with KMIRD to calculate dose conversion coefficients for photon in the energy range from 0.05 to 10 MeV. The simulated irradiation geometries are broad parallel photon beams in AP, PA, LLAT and RLAT direction. Absorbed dose conversion coefficients were compared with data calculated with MIRD5, MIRD-type phantom based on ICRP23 reference man. In some organs, the discrepancies between two phantoms amount up to nearly 30%. The effective doses conversion coefficients of KMIRD are lower than those of MIRD5. The dose discrepancies between two MIRD-type phantoms ate because of physical differences between Korean and Western, also geometric differences between two phantoms. KMIRD should be revised using the full set of Korean reference data of all organs. The developed MIRD-type Korean adult male phantom can be applied to dose assessment of internal exposure.

Importance Analysis of Radiological Exposure by Ground Deposition in Potential Accident Consequences for the Licensing Approval of a Nuclear Power Plant (원전 인허가승인을 위한 사고결말평가에서 지표침적에 의한 피폭의 민감도 분석)

  • Hwang, Won Tae;Jeong, Hae Sun;Jeong, Hyo Joon;Kim, Eun Han;Han, Moon Hee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.89-95
    • /
    • 2014
  • In potential accident consequence assessments for the licensing approval of LWRs, the ground deposition of radionuclides released into the environment is not allowed into the models, as recommended in the U. S. Nuclear Regulatory Commission's regulatory guide. Meanwhile, it is allowed into the assessment models for the licensing approval of PHWRs with consideration of more detailed physical processes of radionuclides in the atmosphere. Under these backgrounds, importance of exposure dose by ground deposition was quantitatively evaluated and comprehensively discussed. For potential accidental releases of $^{137}Cs$ and $^{131}I$, total exposure doses were more conservative in case of without consideration of ground deposition than in case of with its consideration. It was because of that the depletion of air concentration resulting from ground deposition is more influential in the contribution to total exposure doses than additional doses from contaminated ground. The exposure doses by the inhalation of contaminated air showed the contribution of more than 90% in total exposure doses, depending on atmospheric stability, release period of radionuclides and distance from a release point. The exposure doses from contaminated ground showed less than 10% at most in contribution of total exposure doses. The ratios of total exposure doses in case of with consideration of deposition to without its consideration for $^{131}I$ were distinct than those for $^{137}Cs$. As the atmosphere is more stable, release duration of radionuclides is longer, distance from a release point is longer, it was more distinct.

Analysis of Exposure Dose According to Chest and Abdomen Combine CT Exam Method (CT 흉·복부 통합검사 시 선량분석)

  • Mo, KyeongHwan;Han, DongKyoon;Lim, HyunSoo;Jeon, WooJin
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.401-408
    • /
    • 2014
  • The purpose of this study is confirmed to usefulness between division exam and combine exam of chest and abdomen according to comparing chest and abdomen radiation dose of division exam and combine exam in CT exam method. This study was conducted on patients who were admitted to the E hospital from July 2013 to March 2014 underwent CT studies for the diagnosis of chest and abdomen disease. In study result, male dose were more higher than female dose according to gender analysis of exposure dose that combine exam effective dose were male $33.10{\pm}2.75mSv$, female $31.66{\pm}3.12mSv$ and chest exam effective dose were male $9.07{\pm}2.62mSv$, female $8.30{\pm}2.18mSv$(p<0.05). And, division exam dose and combine exam dose were similar in gender comparison (p>0.05). And, combine exam effective dose, only chest exam effective dose, only abdomen exam effective dose were more higher than DRL(Diagnostic Reference Level) in comparison of patient exposure dose with DRL (p<0.05). In conclusion, chest-abdomen combine exam dose and division exam dose were similar. The chest-abdomen combine study can be used as follow-up and emergency trauma patients. That study will be reduce exam time and the occurrence risk of side effect of the contrast medium.

A Study on the Radiation Exposure Dose of Clinical Trainees in the Department of Radiology: A Case Study at C University Hospital (방사선(학)과 임상실습생의 수시출입자 피폭선량에 대한 고찰: C 대학병원 사례 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.249-255
    • /
    • 2023
  • In this study, radiation exposure doses were measured in the course of clinical practice of radiation workers, radiological technologists in the radiation-related worker group, and preliminary-radiological technologists who were classified as frequent visitors. Radiological technologists who worked in the radiation area of C University Hospital in Incheon for a year from January 2021 and 121 students who completed clinical practice at the same medical institution from July 1 to August 31 were the subjects of the study. The nominal risk factor based on ICRP 103 was used to evaluate the probability of side effects due to the exposure dose to the lungs, which are organs at risk of damage due to radiation exposure dose. During the clinical practice period, radiology students, who were classified as frequent visitors, had a surface dose of 0.98 ± 0.14 mSv and a deep dose of 0.93 ± 0.14 mSv. In other words, 6.7 per 1,000,000 for shallow dose and 6.4 per 1,000,000 for deep dose were found to have side effects due to exposure to the lungs. This is a value in terms of exposure dose in one year. Considering that the radiation (science) education course is 3 or 4 years, systematic management and attention to prospective radiation workers who are going to clinical practice are required, and the stochastic effect of radiation In relation to this, it is considered that it will be used as basic data for radiation safety management.

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.

An Effects of Radiation Dose Assessment for Radiation Workers and the Member of Public from Main Radionuclides at Nuclear Power Plants (원전에서 발생하는 주요 방사성핵종들이 방사선작업종사자와 원전 주변주민의 피폭방사선량 평가에 미치는 영향)

  • Kim, Hee-Geun;Kong, Tae-Young;Jeong, Woo-Tae;Kim, Seok-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.12-20
    • /
    • 2010
  • In a primary system at nuclear power plants (NPPs), various radionuclides including fission products and corrosion products are generated due to the complex water conditions. Particularly, $^3H,\;^{14}C,\;^{58}Co,\;^{60}Co,\;^{137}Cs,\;and^{131}I$ are important radionuclides in respect of dose assessment for radiation workers and management of radioactive effluents. In this paper, the dominant contributors of radiation exposure for radiation workers and the member of public adjacent to NPPs were reviewed and the process of dose assessment attributable to those contributors were introduced. Furthermore, the analysis for some examples of radiation exposure to radiation workers and the public during the NPP operation was carried out. This analysis included the notable precedents of internal radiation exposure and contamination of demineralized water occurred in Korean NPPs. Particularly, the potential issue about the dose assessment of tritium and carbon-14 was also reviewed in this paper.

Study on The Planning and Operation of Training Education in Radiologic Science for Reduced x-ray Exposure (방사선(학)과 실습교육에서 X선 피폭 감소를 위한 운영방법에 대한 연구)

  • Kil, Jong-Won;Park, Jung-Ho;Kim, Yong-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.174-179
    • /
    • 2014
  • In this study, we measure the radiation dose for every experiments performed during the training education in radiologic science and estimate the radiation dose to each participant in the training education to propose a safe curriculum including operation of the training education. In this paper, we optimized the three parameters and the results show the dramatically reduced radiation dose to each participant. The proposed arrangement of the subjects and operation of the training education will be very helpful to reorganize the curriculum and the subject operation and will protect the students from the radiation dose.