• Title/Summary/Keyword: 피폭형태

Search Result 93, Processing Time 0.02 seconds

Development and Radiation Shield effects of Dose Reduction Fiber for Scatter ray in CT Exams (피폭선량저감 섬유의 개발과 CT 검사시 산란선 차폐 효과)

  • Kim, Sunghwan;Kim, Yong Jin;Kwak, Jong Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1871-1876
    • /
    • 2013
  • In this study, we developed and characterized the shielding properties of dose reduction fiber (DRF, Buffalo Co.) sheet during brain and chest CT examinations. The DRF sheet was composed of $1{\sim}500{\mu}m$ oxide Bismuth ($Bi_2O_3$) and 5 ~ 50 nm nano-barium sulfate ($BaSO_4$). Phantom and clinical studies were performed for characterization of the DRF shielding properties. In clinical study, we measured doses of eye, chest, abdomen and reproductive system of 60 patients in 3 hospitals during brain and chest CT examinations. We could determined the shielding effect of the DRF by comparing the doses when we used the DRF sheet or not. When we used the sheet during CT examination, the scattered dose were reduced about 20~50%. So, we suggest that the fiber should be used in radiological examinations for reducing patients doses.

A Study on a position detection of radiation using CCD camera (영상센서를 이용한 방사선원 위치탐지 연구)

  • Lee, Nam-Ho;Choi, Chang-Whan;Shin, Ho-Chul;Jun, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.324-326
    • /
    • 2006
  • CCD형 영상소자는 방사선 피폭 시 표면과 격자내부에 모두 손상을 받게 되며, 감마방사선이나 X선과 같은 고에너지의 이온화 방사선에 노출될 경우 격자 실리콘 내부에 전자-전공쌍(Electron-hole pair, EHP)이 발생된다. 이러한 EHP는 CCD의 순간 출력 광전류로 변환되어 백색 화소 형태의 영상잡음으로 가시화되며, 이 화소 수는 피폭 방사선량에 비례하여 증가하는 특성을 지니고 있다. 따라서 출력 영상정보를 분석하면 조사된 방사선의 양과 특성을 측정할 수 있다. 본 연구에서는 CCD를 이용하여 가상의 방사능 물질 누출 공간에서 방사선원의 방향과 거리정보를 고속으로 탐지하기 위한 장치와 고속 측정 알고리즘을 구현하고 실제 방사선장에서 실증시험을 수행하였다. 방사선 탐지기는 콘형 납 콜리메이터(Collimator)와 가시광 변환용 신틸레이터(CsITl) 및 차폐체로 구성된 센서부와 제어 및 방사광 신호처리를 수행하는 PC부로 구성된다. 감마방사선($^{60}Co$) 방사선장 실증시험에서 방사선원간 거리 83cm에서 측정된 거리 탐지는 5.3%의 오차로 확인되었다. 이 방사선 탐지기는 임의의 고방사선 누출사고에 대한 초기대응 작업을 수행하기 위한 무인 이동로봇용 방사선 탐지기로 활용이 가능하다.

  • PDF

Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose (근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가)

  • Kweon, Oh-Jin;Jung, Su-Hee;Baek, Seung-Chan;Kim, Kyeong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.93-97
    • /
    • 2009
  • Purpose: Recognize circulation work system and fixing work system's merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: (1) Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. (2) Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination's number was 14,674 items until 2 quarters 2006~2008 year, and the $^{18}F$-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area's circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse's exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate $^{18}F$-FDG injection, and another is consultation about patient's next time schedule after examination end. Although exposure dose's amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, $^{131}I$-isotope therapy area's radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose's decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people's business efficiency decline.

  • PDF

A Practical Methodology for Determination of Derived Intervention Levels on Relocation Following a Nuclear Accident (원자력 사고후 주민의 이주를 위한 유도개입준위 산정의 실용적 방법론)

  • Hwang, Won-Tae;Kim, Eun-Han;Suh, Kyung-Suk;Jeong, Hyo-Joon;Han, Moon-Hee;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.91-96
    • /
    • 2004
  • A practical methodology for the determination of derived intervention levels (DILs) on relocation following an accidental release of radionuclides was designed based on dose rate on the ground. The influence of DILs was investigated with respect to the change of parameter values, which are dependent on socio-environmental characteristics in distinction from temporary and permanent relocations. The DILs on relocation showed a distinct difference depending on effective removal half-life of radionuclides following a deposition, delay time in measurement and residential characteristics. In particular, the delay time. In measurement was an important factor in determination of DILs in the case of an assumption that dose rate on the ground declines in a power function, not in an exponential function. The DILs showed lower numerical values as longer effective half-life, longer delay time In measurement and longer exposure time.

Measurement of Rn-222 Gas Concentration of Newly Constructed Apartment House in Gwangju Gwangsan-Gu (광주광역시 광산구 소재 신축 아파트 라돈가스 농도 계측)

  • Jang, Hee jun;Lee, Sang bock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.257-261
    • /
    • 2015
  • Radon is produced after the Uranium-238 and thorium-232 undergone radioactive decay process is a colorless, odorless inert gas is stored in a basement or an enclosed space. Building materials are made by a rock or soil materials. Form of radon gas is introduced into the lungs through the respiratory tract and deposited in the lungs or bronchial Daughter nuclides radon causes lung cancer. In this study, To subject the Constructed Apartment in Gwangju Gwangsan-Gu, the position is closed window and opened window was measured using a measuring instrument for radon. The measured results indicate that the measurement was carried out in concentrations of radon gas measured at Newly Constructed Apartment is low than United states in the radon concentration in air public 4 pCi called radon gas baseline maximum allowable concentrations. The exposure caused by radon concentration of new construction apartment when on the measurement results is expected to be insignificant. However, when radon gas like this is that it accumulates in the body and lungs get damaged due to exposure, such as lung cancer often open the windows to reduce the radon concentration measurements, such as in radiation protection aspects to the ventilation to reduce exposure it is considered necessary.

Research on the Transfer Factor for $C^{14}$ Ingestion Dose Evaluation in PWR plant (PWR 발전소에서 $C^{14}$ 섭취선량 평가를 위한 전이계수 연구)

  • Kim Soong-Pyung;Han Young-Ok;Park Kyeong-Rok
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.476-484
    • /
    • 2005
  • This paper is to evaluate rather correctly $C^{14}$ ingestion dose that inhabitants around PWR plants can receive, and draw how to apply TF(Transfer Factor) to evaluate dose by the ingestion of animal products. For this, in this paper, dose assessment and analysis about existing materials related to TF were carried out, and the methodology to present TF was based on dose assessment and analysis result. The ingestion dose calculated using TFs presented by CSA and KEPRI was high or equal compared with SAM(Specific Activity Model) which is the most conservative, on the other hand, TFs given by NEC did not consider the effect according to volume change of animal at all, Therefore, it is judged that models used in the existing codes to asses the $C^{14}$ concentration into animal products must be improved to apply fundamentally hybrid model using transfer factors, that transfer factor on each animal products have to be developed through experiment for applying to our county.

  • PDF

A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department (핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰)

  • Yoo, Jae-Sook;Jang, Jeong-Chan;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.50-56
    • /
    • 2012
  • Purpose: Those who access to the nuclear medicine department are classified as radiation workers, temporarily access group, and occasional access group as defined by the atomic energy law. The radiation workers and temporarily access people wear a personal radiation dosimeter for checking their own radiation absorbed dose periodically. However, because of the sanitation workers, classified as temporarily access group, who are working in the nuclear medicine department are moved in a cycle with other departments and their works are changeful, it is hard to control their radiation absorbed dose. Thus, this study is going to examine the state of the sanitation worker's radiation absorbed dose, and then make sure whether they are classified as temporarily access group or not. Materials and methods: In the first instance, the first sanitation worker who works in vitro laboratory and PET room and the second sanitation worker who works in gamma camera rooms (invivo room) wore radiation dosimeter-OSL(Optically Stimulated Luminescence)- to measure their own radiation absorbed dose during work time from May to June 2011. Secondly, this study was taken place 5 places in gamma camera rooms, 2 places in PET bed room, operating room, waiting room and cyclotron room in PET and 4 places in vitro laboratory. And then to measure the radiation space dose rate, it is measured 10 times each of places as sanitation worker's work flow by using radiation survey meter. Results: The radiation absorbed dose on OSL of the first c who works in vitro laboratory and PET room and the second one who works in gamma camera rooms are 0.04, 0.02 mSv per month respectively. That means the estimated annual radiation absorbed doses are less than 1mSv as 0.48, 0.24 mSv/yr respectively. The radiation space dose rates as sanitation worker's work flow using survey meter are 0.0037, 0.0019 mSv/day, so the estimated annual radiation absorbed dose are 0.93, 0.47 mSv/yr respectively. The weighted exposure dose of first sanitation worker of each places are 1.62% in cyclotron room, 3.88% in waiting room, 2.39% in operating room, 81.01% in bed room of PET and 11.01% in vitro laboratory. The weighted exposure dose of second sanitation worker of each places are 45.22% in radiopharmaceutical laboratory, gamma 30.64% in camera rooms, 15.65% in waiting room, 8.49% in reading room. Conclusion: The annual radiation absorbed doses on OSL of both sanitation workers are less than 1 mSv per year and the annual radiation absorbed doses by using survey meter are less than 1mSv either, but close up to 1 mSv. Thus, to clarify whether the sanitation workers are temporarily access group or not, and to be lessen their s radiation absorbed dose, they should be educated about management of radiation and modified their work flow or work time appropriately, their radiation absorbed dose would be lessen certainly.

  • PDF

Morphological Review of Red Blood Cells After X-ray Irradiation (방사선 조사 후 적혈구의 형태적 고찰)

  • Tae-Jeong Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.223-230
    • /
    • 2023
  • This study attempted to concider the morphological change of red blood cells after whole body irradiation. Blood samples used red blood cells of white mice and mouse after irradiation. Transmission electron microscope observation results, Anisocytosis was observed in red blood cells 20 days after 5 Gy irradiation. Triangle and tetrapod were observed for small red blood cell types. Poikilocytosis, sickle-shaped Drepanocyte, and Acantocyte were observed in general-sized red blood cells. Schizocyte was observed in red blood cells 20 days after 7 Gy irradiation. Scanning electron microscope observation results, Dacryocyte was observed with microcytes. It was also confirmed that red blood cells were get tangled with each other. In addition, polygonal shapes and half-moon shapes were also observed. In conclusion, it is judged that the modified form of pathological study is more important than the numerical change in the study of red blood cells by radiation exposure. In conclusion, it was confirmed that modified morphological studies are more important than numerical changes in the study of red blood cells by radiation exposure.

Measurement of Radon and its Daughters Concentration in Air (공기중 라돈 및 라돈 자핵종의 농도 측정)

  • Park, Y.W.;Ha, C.W.;Ro, S.G.
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.23-29
    • /
    • 1989
  • A Lucas cell was established and calibrated by using the double layer tube standard radon source. The calibration factors were 0.031$\pm$0.002 (pCi/l)/(cph/Cell) at room temperature, and 0.029$\pm$0.001 (pCi/l)/(cph/Cell) at $50^{\circ}C$. Radon and its daughters concentrations were measured in a room air for the demonstrating purpose. The concentrations of 222 Rn, $^{218}Po,\;224\;Pb,\;and\;^{214}Bi$ were 0.87, 0.53, 0.35 and 0.26 pCi/l. The total eqilibrium factor was around 0.40 and the WL is $3.33{\times}10^{-3}$, resulting in 30 mrem/yr at this place.

  • PDF

Dose Assessment in Accordance with the Measured Position of Size Specific Dose Estimates (Size Specific Dose Estimates(SSDE)측정 위치에 따른 피폭선량 평가)

  • Kim, Jung-Su;Hong, Sung-Wan;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.383-387
    • /
    • 2015
  • This study investigated the size specific dose estimates of difference localizer on pediatric CT image. Seventy one cases of pediatric abdomen-pelvic CT (M:F=36:35) were included in this study. Anterior-posterior and lateral diameters were measured in axial CT images. Conversion factors from American Association of Physicists in Medicine (AAPM) report 204 were obtained for effective diameter to determine size specific dose estimate (SSDE) from the CT dose index volume (CTDIvol) recorded from the dose reports. For the localizer of mid-slice SSDE was 107.63% higher than CTDIvol and that of xiphoid-process slices SSDE was higher than 92.91%. The maximum error of iliac crest slices, xiphoid process slices and femur head slices between mid-slices were 7.48%, 17.81% and 14.04%. In conclusion, despite the SSDE of difference localizer has large number of errors, SSDE should be regarded as the primary evaluation tool of the patient radiation in pediatric CT for evaluation.