• Title/Summary/Keyword: 피크검출기

Search Result 107, Processing Time 0.027 seconds

Integrated Circuit of a Peak Detector for Flyback Converter using a 0.35 um CMOS Process (0.35 um CMOS 공정을 이용한 플라이백 컨버터용 피크검출기의 집적회로 설계)

  • Han, Ye-Ji;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.42-48
    • /
    • 2016
  • In this paper, a high-precision peak detector circuit that detects the output voltage information of a fly-back converter is proposed. The proposed design consists of basic analog elements with only one operational amplifier and three transistors. Because of its simple structure, the proposed circuit can minimize the delay time of the detection process, which has a strong impact on the precision of the regulation aspect of the fly-back converter. Furthermore, by using an amplifier and several transistors, the proposed detector can be fully integrated on-chip, instead of using discrete circuit elements, such as capacitors and diodes, as in conventional designs, which reduces the production cost of the fly-back converter module. In order to verify the performance of the proposed scheme, the peak detector was simulated and implemented by using a 0.35 m MagnaChip process. The gained results from the simulation with a sinusoidal stimulus signal show a very small detection error in the range of 0.3~3.1%, which is much lower than other reported detecting circuits. The measured results from the fabricated chip confirm the simulation results. As a result, the proposed peak detector is recommended for designs of high-performance fly-back converters in order to improve the poor regulation aspect seen in conventional designs.

A photoplythsmography starting point detection algorithm for pulse wave velocity (맥파속도 측정을 위한 PPG 기시점 검출알고리즘)

  • Jeong, Seokhoon;Ko, Kuk Won;Lee, Sangjoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.949-951
    • /
    • 2015
  • 본 연구는 맥파속도를 측정 하는데 간단한 방법으로 1채널 심전도 데이터와 4채널 광전식 용적맥파를 이용하여 취득한 데이터를 분석하는 알고리즘을 제안한다. 심전도의 R 피크점과 좌우 지첨, 족첨에서 발생하는 4 채널 맥파신호간 시간차를 이용하여 맥파 전달시간을 구하고 팔, 다리 길이로 나눠서 맥파전달속도를 구한다. 알고리즘은 심전도 R 피크점 검출, 4 채널 맥파에서의 피크점 검출 이후 검출된 피크정보를 이용하여 맥파의 시작지점인 기시점을 검출하는 간단한 방법을 개발하였고, 4 가지 맥파형태에 검출알고리즘을 적용하여 검증 하였다. 본 연구에서 개발한 방법으로 간단히 맥파속도를 측정하여 동맥경화나 고혈압, 당뇨 등 심혈관 관련 연구의 기반이 될 수 있을 것으로 사료된다.

Study on the cascade summing correction for high efficiency HPGe detector (고효율 HPGe 검출기의 동시합성효과 보정 연구)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.107-112
    • /
    • 2005
  • Cascade summing occurs when two gamma-rays emitted in the decay of a single nucleus both deposit energy in a detector. The effect may cause systematic errors that can reach levels of more than ten percent for some radionuclides. A method for estimation of the effect of these coincidences was developed. It is based on direct computation of the effect by means of peak to total ratio measured for the place around the detector. It has been shown that the P/T ratio for the given energy in the working space around the detector may not be a constant value and must use its mean value. Some results from a peak to total calibration study in the presence of scattering materials are also given.

Improvement of Mass Spectral Detection Performance by Pre-correction of Peak Position Error (피크위치오차 사전 보정을 통한 질량 스펙트럼 검출 성능 개선)

  • Lee, Young Hawk;Heo, Gyeongyong;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.666-674
    • /
    • 2019
  • In the mass spectrum of the mass spectrometer, the spectrum of the low peak adjacent to the spectrum having the high peak value is connected to each other and thus the separation is difficult. This inter-spectral overlap causes degradation of the mass spectral detection performance and resolution. In this paper, we propose a method to improve the mass spectrum detection performance and peak accuracy of residual gas analyzer. The type discrimination according to the characteristics of the ion signal block and the pre-correction for the peak position error can separate and detect the spectrum of the low peak connected to the adjacent spectra. To verify the performance of the proposed method, we compared the proposed method with the conventional method in simulations using actual ion signals obtained from the mass spectrometer under development.

Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra (NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.143-151
    • /
    • 1997
  • As the pulse heights from a NaI(Tl) detector vary with the temperature of the measuring environment a significant change in temperature may affect the energy calibration of the spectrometer. The auto-adjustment of the channel corresponding to a pulse heights can be achieved by introducing an external reference source to compensate the temperature dependency of pulse heights, but unfavorable increases of the Compton continuum are caused due to the external source. In this study, the total absorption peaks dominant in the typical environmental gamma spectrum-239 keV from $^{212}Pb$, 351 keV from $^{214}Pb$, 1460 keV from $^{40}K$ and 2614 keV from $^{208}Tl$ for examples - were used as reference in the correction of energy calibration. With these peaks, the program to calibrate the energy of the s spectrum was developed using Microsoft Visual Basic language. The program developed here was applied to the environmental spectra measured at intervals of 30 minutes in the temperature range of from $-20^{\circ}C$ to $10^{\circ}C$ to demonstrate the validity and applicability. As a result of the test, the correction scheme appeared to be effective in the temperature changes encountered in the usual environment.

  • PDF

Development of a Spectrum Analysis Software for Multipurpose Gamma-ray Detectors (감마선 검출기를 위한 스펙트럼 분석 소프트웨어 개발)

  • Lee, Jong-Myung;Kim, Young-Kwon;Park, Kil-Soon;Kim, Jung-Min;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2010
  • We developed an analysis software that automatically detects incoming isotopes for multi-purpose gamma-ray detectors. The software is divided into three major parts; Network Interface Module (NIM), Spectrum Analysis Module (SAM), and Graphic User Interface Module (GUIM). The main part is SAM that extracts peak information of energy spectrum from the collected data through network and identifies the isotopes by comparing the peaks with pre-calibrated libraries. The proposed peak detection algorithm was utilized to construct libraries of standard isotopes with two peaks and to identify the unknown isotope with the constructed libraries. We tested the software by using GammaPro1410 detector developed by NuCare Medical Systems. The results showed that NIM performed 200K counts per seconds and the most isotopes tested were correctly recognized within 1% error range when only a single unknown isotope was used for detection test. The software is expected to be used for radiation monitoring in various applications such as hospitals, power plants, and research facilities etc.

Development of a simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector (HPGe 검출기를 사용한 감마분광분석계의 점검선원 개발)

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.119-123
    • /
    • 2013
  • A simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector was developed. The check source consists of radium-riched soil which was ground in size of less than 0.154mm and contained in air tight cylinderical vial, and provides photons with 12 distinct energies. The spectra of the check source were measured once a month during one year, analyzed the charactreictics of their peaks. When the gamma spectrometry system was in normal state, the areas and FWHMs of the gamma rays with more than 3% gamma emission rate in radium and its decay products was constant within standard deviation 2% and 3%, respectively, except 77 keV peak. And it was found that this check source can play a sufficient role to check the integrity of a gamma spectrometry system using 10 peaks in the range of 77 to 2202 keV.

Development of A FBG Sensor Interrogator for Detecting Strain and Performance Comparison of Peak Detection Algorithms (변형 검출을 위한 FBG 센서 인테로게이터 개발과 피크검출 알고리즘 성능 비교)

  • Park, Keun-Soo;Park, Jang-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.8
    • /
    • pp.1137-1142
    • /
    • 2013
  • FBG sensors are mainly used to measure strain and temperature of structures. In this paper, an interrogator of FBG sensors is developed and implemented to measure the crack of structures using FPGA and DSP. Developed interrogator consists of an optical source, an optical circulator, an optical grating and a CCD sensor and controller. The spectrum of the reflected light from the FBG sensor is analyzed and peak wavelength is detected. Next, strain of structure can be measured using shift of peak wavelength. Centroid algorithm and Gaussian fitting which are mainly applied to detect peak wavelength of the interrogator are compared in this paper. As a result of experiment, Gaussian fitting is suitable for a developed interrogator.

Development of Simulated HPGe Detector Spectrum for Education (교육용 모사 HPGe 검출기 스펙트럼 개발)

  • Seo, Kyung-Won;Lee, Mo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.9-13
    • /
    • 2007
  • From HPGe calibration spectrum of liquid mixed source in cylindrical vial, we developed simulated spectrum for spectrum analysis education. It is the spectrum that combine peaks separated from measured spectrum. After that, spectrum removed statistical variation of channel counts. Statistical fluctuation of the spectrum is made by Box-Muller function. The spectrum contains 18 peaks. The peak's centroid and area were defined exactly. Developed spectra are calibration spectrum, sample spectrum, background spectrum and spectra for efficiency correction for geometry and cascade coincidence.

DC Current Transducer Using Saturable Magnetic Cores (포화자성코어를 이용한 직류전류측정 트랜스듀서)

  • Park, Young-Tae;Jung, Jae-Kap;Gang, Jeon-Hong;Ryu, Kwon-Sang;Yu, Kwang-Min
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.138-142
    • /
    • 2004
  • Uncertainty and characteristics of the developed current sensor by means of two identically wound magnetic cores forming a ring like for measurement of a low DC current such as leakage current was described in this paper. This transducer consists of a sensor type of a current transformer, peak value detectors, a reference alternating low frequency voltage oscillator, precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC current. The resolution and sensitivity of the sensor were 0.1㎃ and 10㎷/㎃, respectively.