• Title/Summary/Keyword: 피에조콘시험

Search Result 62, Processing Time 0.018 seconds

Evaluation of Piezocone Factors for Soft Ground in the Region of Nakdong River Estuary Using Statistical Analysis (통계적 기법에 의한 낙동강하구 점성토 지반의 피에조콘 계수 산정)

  • Kim, Younghun;Jang, Jungho;Choi, Dongchan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.53-66
    • /
    • 2009
  • Recently, the importance of investigation for soft ground has been raised, so that various techniques of the investigation for soft ground are being introduced and applied. In particular, Piezocone penetration test has been utilized frequently home and abroad to identify many features of grounds precisely and gain various results in accordance with dividing strata and depth constantly by measuring continuously. In this study, to identify some features of soft clays distributed in the estuary of Nakdong river, researchers conducted field tests and laboratory tests with boring tests, and analyzed and compared with Piezocone penetration test. In addition, credible Piezocone factor of communities of subjects for this study was estimated to analyze some features of undrained shear strength of clay and calculate Piezocone factor compared with corrected cone resistance and apply some statistical techniques to estimated Piezocone factor.

  • PDF

Estimation of Hydraulic Conductivity Using Piezocone Penetration Test (피에조콘 관입 시험을 이용한 투수계수 산정기법 연구)

  • 송정락
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.2
    • /
    • pp.31-39
    • /
    • 2001
  • 본 연구에서는 수정 Cam Clay 모델과 혼합체 커플링 이론(coupled theory of mixtures)을 이용하여 피에조콘 관입시험을 해석하여 지반의 투수계수와 과잉간극수압의 정량적 관계를 고찰하였다. 본 연구의 이론적 해석 결과는 시험결과들과 비교하였으며 그 결과 피에조콘 관립 시험시 관측된 과잉간극수압은 지반의 투수계수가 $10^{-9}$m/sec에서 $10^{-6}$m/sec의 범위에서는 투수계수에 따라 피에조콘 관립 시험시 관측된 과잉간극수압이 현저하게 변하는 것으로 나타나 피에조콘 관입시험시 관측한 과잉간극수압을 이용하여 지반의 투수계수를 결정할 수 있음을 알 수 있었다. 또한 지반의 투수계수가 $10^{-9}$m/sec 이하에서는 지반이 거의 완전 비배수 상태에 가까운 거동을 나타내면, 투수계수가 $10^{-6}$m/sec 이상에서는 거의 완전 배수상태에 가까운 거동을 하는 것으로 나타났다.으로 나타났다.

  • PDF

Piezocone Factors of Korean Clayey Soils (국내 점성토 지반의 피에조콘 계수)

  • 장인성;이선재;정충기;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.15-24
    • /
    • 2001
  • In order to evaluate undrained shear strength of clayey soils using Piezocone Penetration Test (CPTu), piezoncone factor is utilized. Commonly, piezoncone factors determined by empirical basis were preferred, which were established by correlation between measurements of piezocone test and undrained strengths obtained from other shearing tests. However, previous studies on the empirical piezocone factors were site-specific and there have been no systematic investigations on the effect of both engineering characteristics of clayey soils and soil non-homogeneity on the piezocone factor. Accordingly, the direct application of the previous results to Korean clayey soils without verification may be inappropriate. In this study, empirical piezocone factors are evaluated by comparing 46 CPTu results of 10 test sites with undrained shear strength obtained from Field Vane Test (FVT) and laboratory triaxial tests. Their reliabilities are investigated by the comparison with the previous piezocone factors and the deviation of data distribution from the mean values. And the effects of referencing test methods and typical engineering characteristics of clayey soils such as overconsolidation ratio (OCR) and plastic Index (I$_{p}$) are examined. Because piezocone factors obtained for various soil conditions are widely distributed, it is not appropriate to use the mean value as a representative. Instead, it is recommended to apply the piezocone factors with OCR, which is found to be a major factor in deriving piezocone factor. The necessitated piezocone factors are presented.d.

  • PDF

A Study on Determination of Piezocone Coefficients of Soft Clay Ground (연약지반의 피에조콘계수 결정에 관한 연구)

  • Ahn, Taebong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.9
    • /
    • pp.5-16
    • /
    • 2021
  • In this study, piezocone coefficients of clays (Hwasung, Gunsan, Changwon, Busan) were analyzed from piezocone penetration tests those accompanied with vane shear and UU tests. Piezocone coefficients of west sea clays (Hwasung, Gunsan), i.e, Nkt is 12.6 and Nqu is 8.8, while those of south sea clays are 16.5 and 9.2 respectively. The difference of liquid limit between south and west clays causes main roles those which west sea clay is generally lower than 50%, i.e, CL, and liquid limit of south sea clay is mostly higher than 50%, i.e CH. Piezocone coefficients obtained from several tests show similar trends even though they still have some differences depending on each test. However, they show clear differences depending on liquid limit. Therefore, piezocone coefficients need to be used with caution depending on LL.

Estimation of Soft Ground Piezocone Factors at Gwangyang, Jeonnam (전남 광양지역 연약지반의 피에조콘계수 산정)

  • Oh, Dongchoon;Kim, Kibeom;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.2
    • /
    • pp.59-67
    • /
    • 2019
  • Using the results from laboratory soil test, field vane test and piezocone penetration test, the engineering characteristics of the soft ground at east side of Gwangyang Port, which is located at south coast of Jeollanam-do, were investigated and optimal piezocone penetration test depth was derived to calculate piezocone factor. In this paper, the results of 61 laboratory soil tests, 226 times of field vane tests and 26 piezocone penetration tests were used. The result of laboratory soil test suggested that some physical properties such as specific gravity, moisture content, liquid limit and plastic index and others are higher than other south coast regions, meanwhile uniaxial compression strength, undrained shear strength, defined as mechanical property, appeared to be relatively small, distributed widely. According to the plastic chart, the ground was classified as high compressibility clay and low compressibility clay, mostly represent to Type 3 clay by Robertson (1990)'s classification chart. Piezocone factor was calculated by empirical method, based on the undrained shear strength which was obtained by the field vane test. According to the analysis with 3 different depth range, to set the appropriate measured depth range of piezocone penetration for comparation, using average value of the range of 5 times the vane length showed the highest correlation.

Evaluation of Piezocone Coefficient of Soft Grounds in the Areas of Gyeonggi and Incheon (경인지역 연약지반의 피에조콘계수 평가)

  • Park, Soo-Yong;Kim, Ki-Beom;Lee, Yun-Kyu;Baek, Seung-Cheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.41-49
    • /
    • 2012
  • In this study, laboratory test, in-situ vane shear test and piezocone penetration test in the study area were conducted to investigate the engineering characteristics of soft soils at Cheongra District, Songdo District in Incheon City, the west coast of Gyeonggi province, and Sihwa District in Ansan city. The correlations among compression index, and in-situ vane shear test, and cone resistance were obtained. The variations of liquid limit, plasticity index, water content and compression index with respect to depth exhibit strong similarity. This means that they have strong correlations, which can be used to evaluate the local characteristics of the study area. Thus, the correlations between compression index and physical properties were analysed to investigate the engineering characteristics of soft soil in the study area. The relationships between the measured piezocone factor by empirical methods, and undrained shear strength obtained by triaxial compression test or in-situ vane shear test were compared. It shows the significant correlation and piezocone factors, $N_{kT}$are suggested for the study area.

Determination of the Overconsolidation Ratio using the Piezocone Penetration Test (피에조콘 관입시험에 의한 과압밀비 산정에 관한 연구)

  • Lee, Ki-Se;Shin, Won-Tae;Goo, Nam-Shil;Kim, Hak-Joon
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.351-358
    • /
    • 2007
  • Using the results of the Piezocone Penetration Test(PCPT) which were executed at the Yangsan-Mulgum site, the applicability of the interpretation methods far estimating the OCR(Overconsolidation Ratio) of soft clay was evaluated. At the same time, the results from the laboratory tests using the total of 172 undisturbed soft clay samples taken from the 44 bore holes of the Yangsan-Mulgum site were used to compare the OCR values obtained from the consolidation test with those from the PCPT. The relationship between the predicted overconsolidation ratio($OCR_p$) using the PCPT and the measured overconsolidation ratio($OCR_c$) from the laboratory consolidation tests are investigated and presented in this study. The $OCR_p$ by using the Powell et al.'s method for non-fissured clay from the results of the PCPT shows the best relationship with the $OCR_c$ obtained from the laboratory consolidation test.

Evaluation of Piezocone Factors Applicable to Soft Ground Around Siwha Lake by Statistical Analysis (시화호 주변 연약지반 피에조콘계수 산정에 관한 통계적 분석)

  • Chung, Jin-Hyuck;Park, Soo-Beom;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.89-100
    • /
    • 2008
  • Applying graph and correlation developed in other countries to the domestic field has limits. Therefore, it is necessary that Piezocone factor should be determined by including ground characteristics obtained from various test results in the domestic site for better application. In this study, laboratory tests and field tests were performed to find the characteristics of soft ground which was widely distributed around Siwha lake. A comparative analysis of these tests with Piezocone penetration test was performed and the Piezocone factor was estimated by correlationship analysis of undrained shear strength and cone resistance. Also, an appropriate Piezocone factor in the study site was reestimated by utilizing statistical analysis method for deriving reliable result.

A Study on Piezocone Test using a Calibration Chamber (Calibration Chamber를 이용한 피에조콘 시험에 관한 실험연구)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.3
    • /
    • pp.99-106
    • /
    • 2000
  • 피에조콘 관입 및 소산 시험이 Calibration Chamber 및 미니 피에조콘을 이용하여 수행되었다. 시험은 정규압밀 및 과압밀 점토에 대하여 정지토압 상태에서 실시되었으며 UI (filter element at cone tip), U2 (filter element above cone base) 두 종류의 피에조콘이 사용되었고 0.3cm/sec, 0.6cm/sec의 관입속도가 적용되었다. 오실로스코프를 사용하여 소산시험 초기 간극수압의 급격한 변화를 측정하였다. 시험결과로부터 관입속도, filter element 위치, 과압밀비가 피에조콘 관입 및 소산시험의 결과에 미치는 영향을 고찰하였으며 입도분포시험을 실시하여 관입시험 전후의 입도분포 치이를 고찰하였다.

  • PDF

Numerical Analysis of Piezocone Test using Modified Cam-Clay Model (Modified Cam-Clay Model을 이용한 피에조콘 시험의 수치해석)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.3
    • /
    • pp.89-99
    • /
    • 2001
  • In this study, the numerical analysis of piezocone penetration and dissipation tests has been conducted using the Modified Cam-Clay model, which is generally used in soil mechanics. The Modified Cam-Clay model and related mathematical equations in finite element derivation have been formulated in the Updated Lagrangian reference frame to take the large displacement and finite strain nature of piezocone penetration into consideration. The cone tip resistance, the pore water pressure, and the dissipation curve obtained from the finite element analysis have been compared and investigated with the experimental results from piezocone penetration test performed in Yangsan site. The numerical results showed good agreement with the experimental results; however, the better numerical simulation of the continuous and deep penetration needs further research.

  • PDF