• Title/Summary/Keyword: 피사체 검출

Search Result 41, Processing Time 0.025 seconds

Development of Digital Radiography System Using by an One Dimensional MWPC (1차원 MWPC를 이용한 디지탈 X-선 사진촬영장치의 개발)

  • Park, Jung-Byung;Moon, Myung-Kook;Goo, Sung-Mo;Cho, Jin-Ho;Kim, Do-Sung;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.62-69
    • /
    • 1995
  • We have developed the digital radiography system applied by the one dimensional multiwire proportional chamber. X-ray position signals were obtained from anode wires which were connected to counters through amplifiers and discriminators. The chamber was made of gas flow type and detector gas was P10. The threshold voltage which gives to the discriminator is independent on the neighboring channels. This improved the uniformity of the detector. Then the differential nonlineality is ${\pm}4%$. Increasing the gas pressure, the spatial resolution is about 1.4-mm at which the pitch of the anode wire is 2-mm. The object is scanned in vertical direction to take an image. The number of pixels in the image is $32{\times}32$.

  • PDF

A Dynamically Segmented DCT Technique for Grid Artifact Suppression in X-ray Images (X-ray 영상에서 그리드 아티팩트 개선을 위한 동적 분할 기반 DCT 기법)

  • Lee, Jihyun;Park, Joonhyuk;Seo, Jisu;Kim, Hojoon
    • Annual Conference of KIPS
    • /
    • 2018.10a
    • /
    • pp.813-816
    • /
    • 2018
  • X-ray 진단에서 그리드 하드웨어의 사용은 산란선에 의한 영상의 왜곡을 보정할 수 있는 장점이 있는 반면, 반복되는 라인 형태의 그리드 아티팩트를 발생시키는 부작용을 수반한다. 본 논문에서는 이러한 그리드 라인을 제거하는 방법론으로서 이산코사인변환(DCT: discrete cosine transform)을 사용 하는 기법을 제안한다. X-ray 영상에서 그리드 라인의 특성은 피사체의 형태와 영상의 영역에 따라 서로 다른 특성을 갖는다. 이에 본 연구에서는 동적으로 재구성되는 분할 구조를 기반으로 DCT 변환을 적용하고 개별 영역별로 필터전달함수를 최적화하는 방법을 채택하였다. 추출된 주파수 영역 데이터에 대하여 그리드 라인의 대역을 검출하는 알고리즘을 제안하였으며, 필터전달함수로 Kaiser윈도우와 Butterworth 필터를 조합한 형태의 밴드스톱필러(BSF: band stop filter)를 구현하였다. 또한 블로킹 현상을 개선하기 위하여 다중 영상으로부터 경계선 부분의 픽셀값을 결정하는 방법론을 제안하였다. 제안된 이론에 대하여 실제 영상을 사용한 실험결과로부터 그 타당성을 평가하였다.

Ultrasound Thermography Technique for Detecting Micro Defects in Vehicle Engine Block (자동차 엔진블럭의 미세크랙 검출을 위한 초음파 서모그래피 기법에 관한 연구)

  • Kim, Sung Hyun;Kim, Jae Yeol;Choi, Seung Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.443-446
    • /
    • 2013
  • An infrared thermography technique can be used to inspect a large area simultaneously and to detect defects such as cracks or delaminations in real time. Infrared thermography is a technique in which visual images are formed from the infrared range from subjects according to their thermal radiation. The molecules of all objects are disturbed by heat, and the molecular motion becomes more active when the temperature rises and less active when the temperature falls. In this study, the applicability and feasibility of ultrasound thermography for detecting defects in an engine block, which is a key component in the automobile industry, were verified. A nondestructive reliability test was conducted to study the defects, after which the results were analyzed.

Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations (전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, Jong-Hak;Lee, Ki-Yeol;Kim, Hyung-Cheol;Kim, Jang-Seob;Shin, Dong-Chul;Lee, Sung-Hyun;Lee, Jun-Hyub;Shin, Gwi-Soon
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.453-460
    • /
    • 2009
  • The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of $2{\times}0.5\;mm$, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

  • PDF

Heart Rate Signal Extraction by Using Finger vein Recognition System (지정맥 인식 시스템을 이용한 심박신호 검출)

  • Bok, Jin Yeong;Suh, Kun Ha;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.701-709
    • /
    • 2019
  • Recently, heart rate signal, which is one of biological signals, have been used in various fields related to healthcare. Conventionally, most of the proposed heart rate signal detection methods are contact type methods, but there is a problem of discomfort that the subject have to contact with the device. In order to solve the problem, detection study by non-contact method has been progressed recently. The detected heart rate signal can be used for finger vein liveness detection and various application using heart rate. In this paper, we propose a method to obtain heart rate signal by using finger vein imaging system. The proposed method detected the signal from the changes of the brightness value in the time domain of the infrared finger vein images and converted it into the frequency domain using the image processing algorithm. After the conversion, we removed the noise not related to the heart rate signal through band-pass filtering. In order to evaluate the accuracy of the signal, we analyzed the correlation with the signal obtained simultaneously with the finger vein acquisition device and contact type PPG sensor approved by KFDA. As a result, it was possible to confirm that the heart rate signal detected in non-contact method through the finger vein image coincides with the waveform of actual heart rate signal.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Estimation of Motion-Blur Parameters Based on Stochastic Peak-Trace Algorithm (확률적 극점자취방법을 통한 움직임열화가 발생한 영상에서의 파라메터 추출)

  • 최병철;강문기
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.11b
    • /
    • pp.99-104
    • /
    • 1999
  • 영상을 획득하는 과정에 있어, 영상획득 장치 또는 피사체의 흔들림으로 인해 발생되는 움직임 열화(motion-blur)현상은 영상의 선명도를 크게 떨어뜨리는 주된 원인이 된다. 손상된 영상은 그 영상자체로부터 움직임의 각도와 길이를 추출 함으로서 복원될 수 있다. 본 논문에서는 움직임 열화의 각도와 길이를 추정하기 위한 방법 중, 본 저자가 제안 했던 극점자취방법에, 확률적인 개념을 적용한 새로운 확률적 극점자취 방법을 소개한다. 기존의 방법은 신호지배영역이 올바로 지정되지 않았을 경우, 오차를 수반하기도 한다. 이러한 문제를 해결 하기 위해, 본 연구에서는 maximum likelihood(ML) 분류방법을 이용해 적절하지 않은 극점자취점의 영향을 선택적으로 작게 하여, 신호지배 영역의 설정 없이, 저주파 영역에서의 올른 극점자취의 검출이 가능하도록 하였다. 또한, Auto-regressive(Ah) 모델을 이용한 선형예측방법을 통해 극점 검출과정에서 불규칙하게 발생하는 특이점들이 극점으로 검출되지 못하도록 하여, 정밀한 움직임 방향의 추정이 가능하게 하였다. 또한, 움직임 길이의 검출에 있어서는, 노이즈에 의해 영향을 무시할 수 없는 기존의 영점교차점 방법을 보완한, 새로운 이동평균최소(MALM)법을 정의하였다 이 방법은 움직임 열화가 발생한 영상의 주파수 영역단면 패턴을 이용한 것으로서, 2차원적인 sinc함수를 1차원적인 표현으로 바꾸어주는 이동평균함수를 사용하여, 쉽게 부극점(sub-peak point)을 찾을 수 있도록 한다 부극점 또한 노이즈에 의한 영향을 받지 않고, 이동평균최소법 자체에 노이즈를 제거하는 과정에 포함되어있으므로. 이 방법을 사용하게 되면, 심한 노이즈 환경에서도 적절한 움직임의 길이 값을검출할 수 있다. 이렇게 얻어진 길이와 방향의 파라메터를 이용하여, 실제 실험에 사용된 손상되어진 영상을 효과적으로 복원할 수 있었다.>$\bigcirc$ 펄라이트 : 합섬A(비스코스+레이온)급액천의 유입은 소(1$\times$60cm)에서 21.8ml, 중(2$\times$60cm) 33.5ml, 대(3$\times$60cm) 43.4ml가 통과되었고 합섬(폴리에스텔)에서는 19.0~30.7ml로서 급액천의 규격에 따라 통과되는 차이가 있었다. 배지가 규격화되어 있어 급액천의 규격별로 일정하게 유입되었으며 급액천의 재질이 유입에 영향을 미친 것으로 사료되었다. (2) 급액관과 베드상과의 높이에 따른 유출양 : 급액과 베드상과의 낙차가 클수록 유출이 증가함을 알수 있었으나 합섬C(인견)실험구에서는 낙차가 유출에 영향을 미치지 않았다. (4) 급액된 양액의 EC 및 pH조사 : 급액된 양액의 EC 및 pH에 전혀 변화가 없어 재배 적응에 문제가 없을것으로 사료되었다.이가 가장 이상적인 것으로 생각된다.세포수에 대한 내부세포괴세포(ICM/total cells)가 20~40% 범주에 드는 비율은 처리구가 대조구보다 낮은 결과를 나타냈다. 결론적으로 돼지난포란을 이용하여 체외성숙을 유기할 때 효과적인 cysteamine의 농도는 50$\mu$M이 적당하며, 초기배발달을 유기할 때의 효과적인 cysteamine의 농도는 25~50$\mu$M인 것으로 판단된다.N)A(N)/N을 제시하였다(A(N)=N에 대한 A값). 위의 실험식을 사용하여 헝가리산 Zempleni 시료(15%$S_{XRD}$)의 기본입자분포로부터 %$S_{XRD}$를 계산한 결과, 16%$S_{XRD}$의 결과값을 얻을 수 있었다. 따라서, 본 연구에서 도출한 관계식들이 유효함을 확인할 수 있었다.계식들이 유효함을 확인할 수 있었다.할 때 약간의 증가를 나타냈다.". And

  • PDF

Estimation of Motion-Blur Parameters Based on a Stochastic Peak Trace Algorithm (통계적 극점 자취 알고리즘에 기초한 움직임 열화 영상의 파라메터 추출)

  • 최병철;홍훈섭;강문기
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.281-289
    • /
    • 2000
  • While acquiring images, the relative motion between the imaging device and the object scene seriously damages the image quality. This phenomenon is called motion blur. The peak-trace approach, which is our recent previous work, identifies important parameters to characterize the point spread function (PSF) of the blur, given only the blurred image itself. With the peak-trace approach the direction of the motion blur can be extracted regardless of the noise corruption and does not need much Processing time. In this paper stochastic peak-trace approaches are introduced. The erroneous data can be selected through the ML classification, and can be made small through weighting. Therefore the distortion of the direction in the low frequency region can be prevented. Using the linear prediction method, the irregular data are prohibited from being selected as the peak point. The detection of the second peak using the proposed moving average least mean (MALM) method is used in the Identification of the motion extent. The MALM method itself includes a noise removal process, so it is possible to extract the parameters even an environment of heavy noise. In the experiment, we could efficiently restore the degraded image using the information obtained by the proposed algorithm.

  • PDF

A Development of Effective Object Detection System Using Multi-Device LiDAR Sensor in Vehicle Driving Environment (차량주행 환경에서 다중라이다센서를 이용한 효과적인 검출 시스템 개발)

  • Kwon, Jin-San;Kim, Dong-Sun;Hwang, Tae-Ho;Park, Hyun-Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.2
    • /
    • pp.313-320
    • /
    • 2018
  • The importance of sensors on a self-driving vehicle has rising since it act as eyes for the vehicle. Lidar sensors based on laser technology tend to yield better image quality with more laser channels, thus, it has higher detection accuracy for obstacles, pedistrians, terrain, and other vechicles. However, incorporating more laser channels results higher unit price more than ten times, and this is a major drawback for using high channel lidar sensors on a vehicle for actual consumer market. To come up with this drawback, we propose a method of integrating multiple low channel, low cost lidar sensors acting as one high channel sensor. The result uses four 16 channels lidar sensors with small form factor acting as one bulky 64 channels sensor, which in turn, improves vehicles cosmetic aspects and helps widespread of using the lidar technology for the market.

Thermal Infrared Image Enhancement Method Based on Retinex (Retinex 처리에 기반한 적외선 열상 이미지의 화질 개선)

  • Lee, Won-Seok;Kim, Kyoung-Hee;Lee, Sang-Won
    • 전자공학회논문지 IE
    • /
    • v.48 no.2
    • /
    • pp.32-39
    • /
    • 2011
  • The output image of the uncooled thermal infrared camera is difficult the identification of target because of the limited dynamic range and the various noises. Retinex algorithm based on the theory of the human visual perception is known to be effective contrast enhancement technique. However, the image quality is insufficient when it is adopted to the narrow dynamic range image as the infrared image. In this paper, we propose the revised retinex algorithm to enhance the contrast of the infrared image. To improve the contrast enhancement performance, we designed the new dynamic range compression function instead of log function. To reduce the noise and compensate the loss of edge, we added the contrast compensation procedure in the MSR image generation process. According to the output picture comparing and numerical analysis, the proposed algorithm shows the better contrast enhancement performance and the more suitable method for the infrared image enhancement.