• Title/Summary/Keyword: 피부 흡수

Search Result 242, Processing Time 0.023 seconds

Production Yield Enhancement of Mycosporine-like amino acid(MAA)s in Transformed Microalgae Culture by Radiofrequency (형질전환 미세조류의 고주파 처리 배양을 통한 MAA 생산량 증가)

  • Seo, Hyo Hyun;Song, Mi Young;Kulkarni, Atul;Suh, Sung-Suk;Lee, Taek-Kyun;Moh, Sang Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3799-3804
    • /
    • 2014
  • In sea water, microalgae are exposed to a range of critical environmental conditions. Microalgae are protected from UV-A radiation due to the presence of mycosporine like amino acids(MAAs). Owing to the UV-A absorption properties of MAAs, they are used widely as a UV protecting ingredient in cosmetics. Therefore, there is a need to increase the production yield of MAAs. This study investigated the production yield of MAAs in transformed microalgae by radiofrequency(RF) exposure. Initially, the Glut-1 gene was transformed to Chlamydomonas hedleyi microalgae as a glucose transporter. The biomass was enhanced after Glut-1 gene transformation. In addition, the MAAs production yield was increased during large scale production in bioreactors due to the RF treatment. Therefore, purified extracts of MAAs can be used as a sun block material in the cosmetic industrial field.

Preparation and Characterization of Small Intestinal Submucosa Coated with Poly(vinyl alcohol) for Wound Dressing (창상드레싱을 위한 Poly(vinyl alcohol)을 코팅한 소장점막하조직 시트의 제조와 특성 평가)

  • Lee Min-Suk;Yang Jea-Chan;Kim Soon-Hee;Song In-Bum;Kim Moon-Suk;Khang Gil-Son;Lee Hai-Bang
    • Polymer(Korea)
    • /
    • v.30 no.3
    • /
    • pp.259-265
    • /
    • 2006
  • Small intestinal submucosa (SIS) consists of some growth factors which can stimulate cell activity, and PVA has been widely utilized in the area of wound dressing as hydrogel which is easy to be removed from wounds. In this study, native SIS sheets were coated with PVA by immersing them into 2, 4, and 10 wt% of PVA solution and then lyophilized on two type of molds to endow the prepared wound dressing with easy removal property from wounds. The mechanical properties were examined through tensile test. Moreover, enzymatic degradation, water uptake, and in vitro test were carried out to characterize the prepared SIS sheets. The tensile strength of the SIS sheets coated with PVA (PVA-SIS) were decreased, whereas the elongation were increased. Degradation ratio of the PVA-SIS sheets was decreased compare to native SIS. Water uptake ability was improved at 2 and 4 wt% of PVA. The degree of fibroblast attachment was lower than the native SIS sheets. In conclusion, this study suggests that the PVA coated SIS sheets have a potential for the applications of wound dressing and biodegradable injectable materials.

Characterization as Cosmetic Substances of Chestnut Inner Skin Extracts with Antioxidant Activity (항산화 활성을 갖는 율피 추출물의 향장 소재 특성)

  • Jeong, Hee-Rok;Kim, Ji-Hye;Jo, Yu-Na;Jeong, Ji-Hee;Heo, Ho Jin
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.183-191
    • /
    • 2011
  • We investigated characterization as cosmetic substances of chestnut inner skin extracts with in vitro antioxidant activity. Total phenolics of various extracts from chestnut inner skin were the highest 60% methanol (164.82 mg/g), and ethyl acetate fractions (191.14 mg/g). We found that the both samples from chestnut inner skin dose-dependently increased in vitro antioxidant activities (DPPH radical scavenging activity and inhibition of lipid peroxidation). In addition, the both samples also showed a strong UV absorption in the range of UV-B (290-320 nm). Especially the 60% ethanol extracts presented higher inhibitory effect on elastase (46.40% at $100{\mu}g/mL$) than that of the ethyl acetate fractions, so that it showed in vitro anti-wrinkle activity. Finally, the 60% methanol extracts and ethyl acetate fractions showed anti-bacterial activity against skin pathogenic bacteria. Consequently, these results suggest that the chestnut inner skin can be used for cosmetic industry.

Input Power Determination of TEM Cell Due to SAR for Mobile Phone Wave Blood Exposure (휴대폰 전자파의 혈액 조사를 위한 SAR별 TEM 셀의 입력 전력 산출)

  • Youn Ji-Hun;Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.810-814
    • /
    • 2005
  • Input power for TEM cell apparatus due to SAR(Specific Absorption Rate) for culture blood cell is determined by the transmission and reflection measurement of blood into the TEM cell. Blood cell with skin cell are reference culture cells for the study of EM wave effect. Exposure RF power from exposure apparatus to culture cell should not only exact for SAR value, but also should be based on the theoretical theory. In this paper, insertion loss of 50 g blood was measured to know exposure power per gram for culture blood cell, and input power of TEM cell due to SAR 0.8, 1.6, 3, 4 mW/g using the measured data are delivered. This study is for applying to EM wave exposure apparatus to culture cell.

The Visual Analysis of Myofascial Syndrome on Balance Posture (근육 근막 장애가 자세균형에 미치는 시각적 분석)

  • Park Young-Han
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.177-184
    • /
    • 1997
  • 1. The human body is the unification related to the powerful fascial network, I think. 2. Myofascial not only prevent and support the human body structure curdling but also keep the physical balance by dispersing traumatization properly. 3. Myofascial restriction will be developed into muscle deficiency and cause pains without releasing the muscle tension and the spasm. 4. Myofascial restriction affect and change the physical posture by losing the muscle elasticity and flexibility and by losing muscle supporting ability from gravitation. 5. The partial myofascial restriction affect the muscle and the adjoining joint supporting gravitation and cause the unbalance of the entire body.

  • PDF

Validity of Bioelectrical Impedance Analysis(BIA) in Measurement of Human Body Composition (소아 체지방 평가를 위한 생체 저항분석법의 타당성 연구 : 이중 에너지 방사선 흡수법과의 비교)

  • Kim, Hyung-Suck;Kim, Su-Yung
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.696-700
    • /
    • 2005
  • Propose : Body composition by bioelectrical impedance analysis(BIA) is a very useful method of analysing body composition. BIA is non-invasive, inexpensive, nonhazaedous and reproducible technique. The aim of this study was to determine the level of agreement between body composition measurement by BIA and dual-energy X-ray absorptiometry(DEXA). Methods : Data was examined in 100 children(male 58; female 42), who visited Pusan National Hospital. Weight(kg) and height(cm) were measured, and body compositions were analyzed with fat mass, lean body mass, body fat percent by BIA and DEXA methods. Results : Comparison of the DEXA and BIA methods showed highly statistically significant correlations in measurement of human body composition(fat mass, lean body mass, body fat percent). Conclusion : BIA should be considered as the method of choice in measurement of human body composition, since it's non-invasive, reliable, rapid, nonhazaedous and inexpensive, using portable equipment.

Transdermal Delivery of FITC-Ovalbumin with Microneedle System (마이크로 피부침을 이용한 FITC-OVA의 경피흡수)

  • Jang, Woo-Young;Lee, Chang-Rae;Seo, Seong-Mi;Lee, Bong;Kim, Moon-Suk;Khang, Gil-Son;Lee, Han-Gu;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.403-409
    • /
    • 2005
  • For transdermal delivery of large molecular drugs such as vaccine and protein drugs, novel microneedle treatment device with roll was designed. The roll dimension is 1.43 cm diameter and 2.8 cm perimeter. Total number of microneedle on the roll is 3,360 with $230\;{\mu}m$ height and $740\;{\mu}m$ distance. The pore with $150\;{\mu}m$ depth and $35\;{\mu}m$ diameter on the skin was made by the designed microneedle device. This system could be achieved without pain. The permeation rates of FITC labelled ovalbumin (FITC-OVA, molecular weight: 45,000 g/mol) as a model protein were determined by modified Franz diffusion cells using skins of hairless mice or SD rats which were treated by using microneedle device two or four times. The average penetration fluxes of model protein increased from 674 to $872\;{\mu}g/cm^{2}{\cdot}hr$ as the number of treatment to make pore increased from two to four times. In conclusion, we confirmed the possibility of using the designed microneedle treatment device for transdermal delivery of the large molecular drugs.

Characterizing and Analysis of the Peptide in Extract from Camellia sinensis (녹차에 함유된 펩타이드 분리 방법 및 추출물의 특성 분석)

  • Yoo, Se-Jin;Baek, Seok-Yun;Cho, Jun-Choel;Park, Ji-Won;Lee, Sung-Hyun;Choi, Ho-Min;Cho, Moon-Jin;Moh, Sang-Hyun;Lee, Jeong-Hun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.269-273
    • /
    • 2012
  • 본 연구는 알려진 녹차의 다양한 항산화, 항염 효능이 있는 Polyphenol 류 이외의 생물학적 활성을 가지는 펩타이드 및 당단백질 소재에 대한 특성과 분석을 위하여 연구되었다. 녹차에서 수용성 성분을 추출 후 알콜 침전방법을 사용하여 단백질과 펩타이드류를 분리하여 실험에 사용하였다. 전체 추출물 중에는 Glutamic acid가 14073.9ug/g, (39.11%)로 가장 높게 분석되었으며, GPC 분석결과 Mn 886, Mw 25218, Mp 890, Mw/Mn 28.46으로 분석이 되었으며, 전체적으로 3개의 피크로 분석되었다. 함유된 펩타이드를 분석하기 위하여 HPLC를 이용하여 RT 16.148min의 Fraction을 분리하여 펩타이드 분석결과 녹차에서 유래한 TNTLSN이라는 hexapeptide를 동정하였다. 이러한 펩타이드는 친수성이며, 안정도가 높은 특징을 가지고 있고, 분자량이 1000이하로 피부 흡수도가 높을 것으로 기대되며, Biodegradable하며, Renewable 한 자연 친화적인 화장품 소재로서 널리 활용될 수 있을 것으로 판단된다.

  • PDF

SKIN ABSORBED DOSES FROM FULL MOUTH STANDARD INTRAORAL RADIOGRAPHY IN BISECTING ANGLE AND PARALLELING TECHNIQUES (각이등분법 및 평행법에 의한 전악 구내 표준 촬영시 두경부 피부 흡수선량 비교)

  • Kim Ae-Ji;Nah Kyung-Soo;Doh Shi-Hong;Kim Hyun-Ja;Yoo Meong-Jin
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.315-333
    • /
    • 1990
  • This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography (l4 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator(60㎜ in diameter, 20㎝ in length) and rectangular collimator(35㎜ × 44㎜, 40㎝ in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rates of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling techniuqe, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  • PDF

Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System (6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석)

  • Yoon, Seok;Jung, Hyeonjong;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.954-963
    • /
    • 2017
  • In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.