• Title/Summary/Keyword: 피난 안전성

Search Result 253, Processing Time 0.021 seconds

Analysis of Performance-based Design Guides of Smoke Control System (성능위주 연기제어 설계지침 분석)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.6-13
    • /
    • 2016
  • With regard to smoke control system, the design guidelines of smoke exhaust for accommodation and smoke control for evacuation stairs and vestibule has been proposed domestically, but after reviewing the applicability to modern buildings that tend to be larger, higher and complex, a smoke control system according to domestic design guidelines might have difficulty in securing the safety from smoke in a fire. Therefore, it is necessary to adopt the performance-based design of a smoke control system that can enhance the safety and integrate the smoke control functions and design depending on the characteristics of fire and building structure in the case of fire in a large, high-rise, and complex building. This study analyzed the domestic design guidelines of a smoke control system and this paper proposes the part requiring improvement, and examines the legal system and guidelines on performance-based design of smoke control system in foreign countries.

Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident (후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가)

  • Kim, Min Jun;Go, A Ra;Kim, Kwang Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except $5{\times}5{\times}2m\;size$) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a $50{\times}50{\times}2m\;size$ facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings (중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구)

  • Min, Se Hong;Lee, Jae Moon;Bae, Yeon Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

Evaluation of Lateral Load Resistance and Heating/Cooling/Lighting Energy Performance of a Post-disaster Refugees Housing Using Lightweight composite Panels (경량 복합패널을 활용한 구호주거의 횡하중 저항성능 및 냉난방조명 에너지성능 평가)

  • Hwang, Moon-Young;Lee, Byung-Yun;Kang, Su-Min;Kim, Sung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.252-262
    • /
    • 2019
  • Following the earthquake in Gyeongju (2016) and Pohang (2017), South Korea is no longer a safe place for earthquakes. Accordingly, the need for shelters suitable for disaster environments is increasing. In this study, a lightweight composite panel was used to produce post-disaster housing for refugees to compensate for the disadvantages of existing evacuation facilities. For this purpose, an evaluation of structural performance and thermal environment for post-disaster housing for refugees composed of lightweight composite panels was performed. To assess the structural performance, a lateral loading test was conducted on a system made of lightweight composite panels. The specimens consisted of two types, which differed according to the bonding method, as a variable. In addition, the seismic and wind loads were calculated in accordance with KBC 2016 and compared with the experimental results. Regarding the energy performance, optimization of south-facing window planning and window-wall ratio and solar heat gain coefficient were analyzed to minimize heating, cooling, and lighting energy. As a result, the specimens composed of lightweight composite panels will perform sufficiently safely for lateral loads and the optimized window planning will lead to a low-energy operation.

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.

A Study on the Barrier-Free Space through IPA Method for the Elderly in Multi-family Housing (IPA 분석기법을 통한 공동주택의 무장애공간 인증기준 적합성 분석연구)

  • Kim, Ju-Whan;Kim, Won-Pil
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.187-194
    • /
    • 2020
  • When a human being grew older, followed by visually and perceptually impaired, and dementia, it jeopardizes safety and life unless supportive design is secured for a living environment. This supportive space is based on universal design concept which offers safe-oriented, and simple use by incorporating gender and physical/mental limitation. The study of purppose was to examine the appropriateness of barrier-free standard for seniors' living in apartment through IPA. Chi-square analysis found that satisfaction with BF space is lowered as aging is continued and for female group. Regression analysis indicated that sink was the prime predictor in satisfaction, and stair/elevator was the most important variable. IPA concluded that sink, bath, shower/locker and alert/egress were prime BF indexes to be improved among 14 elements, implying careful design in sanitation area for seniors.

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.

The Effects of Apartment Facility Maintenance on the Residential Satisfaction of Residents (아파트 시설물 유지관리가 입주자의 주거만족도에 미치는 영향)

  • Kim, Myung-Hee;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.175-183
    • /
    • 2020
  • This study suggests a solution regarding the effects of apartment facility maintenance and fire safety facility maintenance on the residential satisfaction of residents. The results are as follows. Firstly, facility maintenance had a negative effect on residential satisfaction. Analysis revealed that residential satisfaction decreased the more breakdowns there were in the facilities. This revealed that when maintenance staff neglect the residents' complaints due to the repetitive aspect of their jobs, there was a negative effect on residential satisfaction; therefore, residential satisfaction must be increased by maintaining the facilities well and training support for maintenance staff. Secondly, fire safety facilities had a negative effect on residential satisfaction. Analysis revealed that residential satisfaction decreased the more malfunctions there were in the fire safety facilities and the more replacements there were in fire fighting equipment. This revealed the importance of safety and the fact that the apartment heavily relies on fire safety facilities because there may be a low awareness regarding safety; therefore, maintenance staff must lower the damage from fire safety facilities and to increase the residential satisafaction of residents. Lastly, there needs to be repetitive training and education for residents regarding fire fighting and evacuating in accordance with the fire fighting plan as a means to strengthen residents' safety awareness.

Investigation on Users' Perception and Certification Status and Donning of Smoke Masks (방연마스크에 대한 사용자 인식, 인증 현황 및 착용성 조사)

  • Hyunwoo Son;Yeongeun Park;Eungwoo Lee;Eunji Kim;Youngbo Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.68-73
    • /
    • 2023
  • Smoke masks have attracted great interests and have been supplied widely for the improvement of the safety during fire evacuation. However, there is not sufficient research on the practical utility, certification status and easy-donning about commercial smoke masks, therefore it is difficult to determine the actual usefulness of the smoke masks. In this study, we conducted a survey on users' perceptions and experiences about the smoke masks, and investigated the status of certification of 54 commercial smoke masks. We also performed donning tests and examined degrees of discomfort for 4 types of the smoke masks. Although 22% of 235 respondents had experienced the smoke masks before the test, and 23% of the respondents did not know the smoke masks, 93% of the respondents expected that the smoke masks could protect users from fire smokes and toxic gases. It was found that 41% of the commercial smoke masks did not certify according to domestic or overseas performance standards. Most certification standards have not effectively regulated maximum wearing time for the smoke masks. Only ASTM E 2952 and KFIS 024 had specific standards for the maximum wearing time of 30 s. As a result of donning tests for 4 types of smoke masks, the wearing time of the hood-type mask and self-contained smoke mask exceeded 30 s, therefore these types of smoke masks might increase the required safe evacuation time. On the other hand, it was also found that short education about the donning could reduce the wearing time by 19% and numbers of improper wearing by 89%.

Evaluation on th e Wear Fit and Activity of Emergency Escape Breathing Devices for Ship Accidents (선박사고용 호흡구난장비의 착용성 및 활동성 평가 연구)

  • Noh, Jae-Hyeon;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.79-84
    • /
    • 2019
  • The use of emergency escape breathing devices (EEBD) is strongly required to protect against toxic gas or flooding caused by ship fires or accidents. Recently developed domestic EEBD products only satisfy the basic performance requirements, but no wear fit and activity performance evaluation has been done for real usage. In this study, the global level test requirements for wear comfort and activity of EEBDs were developed and the open and closed type of domestic EEBD products were evaluated. Poor visibility, longer wear time, breathing resistance, and hose obstruction in an open type and canister obstruction, weight unbalance, and an invisible black breathing bag in the closed type EEBD were estimated to be the main problems that need to be improved.