• Title/Summary/Keyword: 플라스마(plasma)

Search Result 169, Processing Time 0.03 seconds

Determination of Total Arsenic in Drinking Water by Inductively Coupled Plasma-Mass Spectrometry (유도결합 플라스마 질량 분석법(ICP-MS)을 이용한 음용수 중의 전체 비소의 정량)

  • Lim, Yoo-Ree;Park, Kyung-Su;Yoon, Yang-Hee;Kim, Sun-Tae;Chung, Jin-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.423-427
    • /
    • 2000
  • Total arsenic in drinking water such as spring, small water-supply system and mineral water was determined by inductively coupled plasma mass spectrometry. The contents of total arsenic were analyzed after acidification by nitric acid to become 1% in water samples. According to the results, total concentration of arsenic in drinking water was below 30ppb.

  • PDF

Friction and wear properties of plasma-sprayed $Cr_2$$O_3$/$MoO_3$ composite coatings ($MoO_3$가 첨가된 $Cr_2$$O_3$ 플라스마 용사코팅의 마찰 마멸 특성)

  • 여인웅;안효석;임대순
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.22-29
    • /
    • 2001
  • Plasma-sprayed coatings were prepared using by spray-dried Cr$_2$O$_3$ powder with and without MoO$_3$ addition. A reciprocal type tribe-tester was employed to examine friction and wear behavior of the specimens at room temperature. The worn surfaces of plasma spray coated specimens were observed by SEM. The results showed that friction coefficient of the MoO$_3$-added coatings were lower than those without MoO3 addition. However pure Cr$_2$O$_3$ coating showed the lowest wear loss at the self-mated test. The larger protecting layers were observed at the worn surface of plasma spray coated specimens with MoO$_3$ addition.

  • PDF

Development of an Axially Viewed Inductively Coupled Plasma for Atomic Emission Spectrometry and Comparison between the Detection Limits of Lead (원자방출 분광분석을 위한 수평형 유도결합 플라스마의 개발과 납 검출한계 비교)

  • Cho, Sung Il;Han, Myung Sub;Lee, Sang Hwa;Lee, Joung Hae;Woo, Jin Chun
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.6
    • /
    • pp.292-298
    • /
    • 1997
  • An ICP(Inductively Coupled Plasma) emission spectrometer was developed with an axially viewed ICP source incorporated by a 5-turned induction coil and a torch, outer quartz tube of which was 50 mm longer than that used in conventional ICP/AES(Inductively Coupled Plasma Atomic Emission Spectrometry). The Optimization of the system has been performed in terms of the determination of signal-to-noise ratio and background intensity at various rf powers, sample flow rates, argon gas flow rates and cut-off gas flow rates. The spectro-analytical characteristics of the spectrum obtained between 200 and 500 nm was revealed to be similar compared with a vertically viewed ICP source. The detection limit of Pb(Ⅱ) at 220.35 nm was 11 ppb which was 5 times lower than that obtained with a vertically viewed ICP source.

  • PDF

Enhancement of Corrosion Resistance of Mg Sheets with Plasma Surface Treatment (플라스마 표면처리에 의한 마그네슘 판재의 내식성 향상)

  • Yang, Ji-Hun;Jeong, Jae-In;Park, Yeong-Hui;Gwak, Yeong-Jin
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.33-33
    • /
    • 2008
  • 산소 플라스마를 이용하여 마그네슘 판재를 표면처리한 후 내식성 변화를 관찰하였다. 마그네슘 판재표면처리 시 표면처리 온도, 표면처리 전압, 공정 가스 유량비 등의 변수에 대한 효과를 분석하여 최적 조건을 도출하였다. 표면처리 온도가 높을 경우, 마그네슘 판재의 내식성이 향상되었으며, 표면처리 전압이 일정한 값보다 높으면 이온의 운동 에너지가 증가하여 마그네슘 판재 표면에 손상을 입혀 오히려 내식성이 나빠지는 현상을 보였다. 공정 가스는 산소만을 사용하여 표면 처리할 경우, 마그네슘 판재의 내식성이 향상되는 현상을 관찰하였다.

  • PDF

Optimal Hydrophilization and Chondrocyte Adhesion of PLLA Films and Scaffolds by Plasma Treatment and Acrylic Acid Grafting (플라스마 처리와 아크릴산 결합에 의한 PLLA 필름 및 지지체의 최적 친수화와 연골세포 점착)

  • Yang Hee-Seok;Park Kwi-Deok;Ahn Kwang-Duk;Kim Byung-Soo;Han Dong-Keun
    • Polymer(Korea)
    • /
    • v.30 no.2
    • /
    • pp.168-174
    • /
    • 2006
  • To utilize as highly functional scaffolds for tissue engineering by improving hydrophobicity and cell compatibility of the exist polymer scaffolds, the biodegradable poly(L-lactic acid) (PLLA) films and scaffolds having the optimal hydrophilicity were prepared by in situ plasma treatment and grafting of a carboxyl acid-containing monomer, acrylic acid (AA) in the chamber. From the results of surface analyses, surface-modified nonporous PLLA film and dual pore scaffold surfaces showed high hydrophilicity due to the decrease in contact angle and the increase in carboxylic groups as compared with untreated PLLA control. In particular, among various surface modification methods, Ar(argon)+AA+AA sample prepared by Ar plasma and then acrylic acid treatments displayed lower contact angle and more carboxylic groups thar Ar/AA and Ar+TP(thermal polymerization) samples, indicating that Ar+AA+AA sample was optimally treated for improving its hydrophilicity. In the cases of surface modified nonporous PLLA films and dual pore scaffolds, the adhesion and proliferation of chondrocytes increased with increasing their hydrophilicity.

Construction of CVD by using RF Helicon Plasma (RF 헬리콘 플라즈마를 이용한 회학기상 증착기의 제작)

  • 신재균;현준원;박상규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.8
    • /
    • pp.607-612
    • /
    • 1998
  • RF HPCVD(Helicon Plasma Chemical Vapor Deposition) has been successfully constructed for diamond thin films. The system consists of plasma generation tube, deposition chamber, pumping lines for gas system. A mixture of $CH_4 and H_2$is used for reaction. Two thermocouples, a quartz tube surrounded by a RF antenna and a magnet, and a high temperature heater were set up in the deposition chamber. The process for the thin film diamond deposition has been carried put in a high vacuum system at a substrate temperature of $800^{\circ}C$, and pressure of 5 mtorr. It is also demonstrated. that the RF HPCVD system has advantages for controlling deposition parameters easily.

  • PDF

Spark Plasma Sintering Technique and Application for All-Solid-State Batteries (전고상 전지를 위한 스파크 플라스마 소결 기술과 응용)

  • Lee, Seokhee
    • Ceramist
    • /
    • v.22 no.2
    • /
    • pp.170-181
    • /
    • 2019
  • All-solid-state batteries have received increasing attention because of their high safety aspect and high energy and power densities. However, the inferior solid-solid interfaces between solid electrolyte and active materials in electrode, which cause high interfacial resistance, reduce ion and electron transfer rate and limit battery performance. Recently, spark plasma sintering is emerging as a promising technique for fabricating solid electrolytes and composite-electrodes. Herein, this paper focuses on the overview of spark plasma sintering to fabricate solid electrolytes and composite-electrodes for all-solid-state batteries. In the end, future opportunities and challenges associated with SPS technique for all-solid-state batteries are described.

A Study on the Gas Permeation Characteristics of Plasma Polymers (플라즈마 고분자에 대한 기체의 투과특성에 관한 연구)

  • Oh, Sae-Joong
    • Membrane Journal
    • /
    • v.4 no.4
    • /
    • pp.205-212
    • /
    • 1994
  • Gas permeation properties of simple gases(He, $H_2,\;CO_2,\;O_2,\;N_2,\;CH_4$) through plasma-polymerized films were investigated, and the chemical structure of the plasma polymers was analyzed by infrared spectra. The plasma-polymerized films were prepared by plasma polymerization of fluorine-containing aromatic compounds, and permeation measurements were made at $35^{\circ}C$, latm. The permeability coefficient of the plasma films decreased as the size of penetrant molecules increased. The plasma polymers showed higher $CO_2/CH_4$ selectivities than those of commonly used polymers, while $O_2/N_2$ selectivities were similar of slightly lower than those of common polymers. FT-IR spectra shows that the plasma polymers contain both aromatic and aliphatic structures.

  • PDF

Study for Conductive and Non-conductive Multi-layers Depth Profiling Analysis of Radio Frequency Gas-jet Boosted Glow Discharge Spectrometry (Modified Gas-jet Boosted Radio-frequency Glow Discharge 셀의 개발 및 최적화에 관한 연구)

  • Cho, Won Bo;Borden, Stuart;Jeong, Jong Pil;Kang, Won Kyu;Kim, Kyu Whan;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.108-114
    • /
    • 2002
  • The new system using a glow discharge atomic emission spectrometer for the direct analysis of solid samples has been developed and characterized. The system was consisted of new glow discharge cell improved previous gas-jet boosted nozzle and radio-frequency power supply. In the case of previous type glow discharge chamber, it had been fitted trace analysis of low alloy steel with low discharge power, because it was to decrease redeposition and increase sample weight loss. But it had a problem that plasma becomes unstale due to increased sample weight loss and redeposition resulting from the high discharge power. Because of being problem of previous glow discharge, it is impossible to analyze using high power. The modified gas-jet boosted glow discharge to solve this problem would improve to be less sample loss rate of modified nozzle than sample loss rate of previous nozzle on the equal discharge condition, and improve to increase stability of plasma. The effect of discharge parameters such as discharge pressure, gas flow rate and power on the sample loss rate, emission intensity has been studied to find optimum discharge conditions. The calibration curves of Fe were obtained with 3 low-alloy samples.

Enhancement of the Bright Room Contrast Ratio in a Plasma Display Panel (플라스마 디스플레이 패널에서 명실 콘트라스트 개선)

  • Moon, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • A new electrode structure in a plasma display panel was designed in a way to increase the bright room contrast ratio (BRCR). The area of the black matrix pattern to get a low reflection from the panel surface was enlarged using the new electrode design concept. The electrical characteristics such as firing voltage, voltage margin and power consumption were measured. The luminance of the panel was measured and the luminous efficiency was calculated. It was found that the new electrode structure was very effective to enhance the BRCR.