• Title/Summary/Keyword: 플라스마(plasma)

Search Result 169, Processing Time 0.03 seconds

Improvement of Barrier Property of LDPE Food Packaging Film by Plasma Polymerization (플라스마 중합을 이용한 LDPE 식품포장 필름의 차단성 향상)

  • Kim, Kyoung-Seok;Cho, Dong-Lyun
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.38-42
    • /
    • 2008
  • Ultrathin films were coated on low density Polyethylene (LDPE) food packaging films by plasma polymerization of methane, acetylene, hexamethyldisiloxane (HMDSO), and HMDSO+oxygen to improve the barrier property of the LDPE films. The film coated in HMDSO +oxygen (flow rate: 0.6+ 9.0 SCCM) plasma at 40 W for 10 min showed the highest improvement in the barrier property against oxygen, reducing the permeability of oxygen as much as 18.6 times. The film coated in acetylene (flow rate 0.75 SCCM) plasma at 10 W for 10 min showed the highest improvement in the barrier property against carbon dioxide and moisture, reducing the permeability of carbon dioxide and moisture as much as 12.0 and 3.0 times, respectively. In addition, cherry tomato, cucumber, and mushroom (Flammulina velutipes) wrapped with the coated films were kept fresh $1.5{\sim}3.0$ times longer than those wrapped with an LDPE film.

Blood Compatibility of Hollow Fiber Membranes Treated by Plasma Polymerization (플라즈마 중합 처리된 중공사 막의 혈액 적합성)

  • Lee, Sam-Cheol;Kwon, O-Sung
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.233-240
    • /
    • 2005
  • Surface modification of polypropylene hollow fiber membranes was performed in order to develop blood-compatibility biomaterials for use in the blood contacting surfaces and oxygenation membranes of a lung assist device (LAD), important medical device even more useful. Blood compatibility of materials was determined by using anticoagulation blood and evaluating formation of blood clots on their surfaces as well as activation of plasma coagulation cascade, platelet adhesion, and aggregation. It was verified that the number of platelets on the silicone coated fibers was significantly lower than that on untreated fiber membrane, indicating improved blood compatibility. It was also found that the polypropylene hollow fiber membranes using plasma treatment exhibited suppression of complement activation in blood compatibility test.

Development and characteristics investigation of new soft plasma ionization(SPI) source (새로운 소프트 플라스마 이온화(SPI) 장치의 개발 및 특성관찰)

  • Lee, Hiwwon;Park, Hyunkook;Lee, Sang Chun
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.152-158
    • /
    • 2009
  • In this study, we made a new discharge source improving previous SPI source to ionize softly organic compounds. The new SPI source consists of two electrodes as a hollow mesh cathode of half cylindrical shape and a hollow anode. We optimized the geometrical parameter of the SPI source by investigating the I-V curves at the various distance between the cathode and the anode. As the results, we found stable conditions of the soft plasma on broad range of the current and the voltage. The new SPI source attached to quadrupole mass spectrometer (QMS), and we obtained the mass spectra of dichloromethane (DCM). The fragment patterns of DCM appeared similarly with the pattern of electron ionization (EI).

Rare Earth Element Analysis with Chromatography-Inductively Coupled Plasma Atomic Emission Spectrometry and the Comparison of Cross Flow and Ultrasonic Nebulizers (크로마토그래피-유도 결합 플라스마 원자방출 분광법을 이용한 희토류 원소들의 연속적 분석 및 직교형과 초음파분무기의 비교)

Decomposition of NOx by SPCP+AC Superposing Discharge Plasma Reactor (SPCP+AC 중첩 방전 반응기에 의한 NOx의 분해 제거)

  • 선상권;우인성;황명환;박동화;김윤선;산외서수
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.217-222
    • /
    • 1999
  • 비열플라스마를 형성하는 방법은 전자 beam조사식과 전기방전법이 있다. 이 두방법의 공통점은 고에너지의 전자를 생성하여 플라스마를 발생시켜 가스분자의 전자충돌과 이온화에 의해 free radical반응에 의하여 가스분자를 분해시키는 것이다. (중략)

  • PDF

Fabrication of the Plasma Focus Device for Advanced Lithography Light Source and Its Electro Optical Characteristics in Argon Arc Plasma (차세대 리소그래피 빛샘 발생을 위한 플라스마 집속 장치의 제작과 아르곤 아크 플라스마의 발생에 따른 회로 분석 및 전기 광학적 특성 연구)

  • Lee S.B.;Moon M.W.;Oh P.Y.;Song K.B.;Lim J.E.;Hong Y.J.;Yi W.J.;Choi E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.380-386
    • /
    • 2006
  • In this study, we had designed and fabricated the plasma focus device which can generate the light source for EUV(Extreme Ultra Violet) lithography. And we also have investigated the basic electrical characteristics of currents, voltages, resistance and inductance of this system. Voltage and current signals were measured by C-dot and B-dot probe, respectively. We applied various voltages of 1.5, 2, 2.5 and 3 kV to the anode electrode and observed voltages and current signals in accordance with various Ar pressures of 1 mTorr to 100 Torr in diode chamber. It is observed that the peak values of voltage and current signals were measured at 300 mTorr, where the inductance and impedance were also estimated to be 73 nH and $35 m{\Omega}$ respectively. The electron temperature has been shown to be 13000 K at the diode voltage of 2.5 kV and this gas pressure of 300 mTorr. It is also found that the ion density Ni and ionization rate 0 have been shown to be $N_i = 8.25{\times}10^{15}/cc$ and ${\delta}$= 77.8%, respectively by optical emission spectroscopy from assumption of local thermodynamic equilibrium(LTE) plasma.

DEVELOPMENT OF OPTICAL CARIES ACTIVITY TEST USING DENTAL CURING LIGHT (광중합기를 이용한 광학적 치아우식활성도 검사법)

  • Lee, Nan-Young;Kim, Mi-Ra;Oh, You-Hyang;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.671-679
    • /
    • 2004
  • The purpose of this study was to develop a practical caries activity test by fluorescence using laser, plasma light and halogen light. The subjects of study were 45 children of 7-8 years old Argon laser, plasma light and halogen light were irradiated to buccal or labial surface of all teeth. Fluorescence of initial carious lesion from teeth was observed through barrier filter and the number of teeth showing lesion was counted. Visual examination for the dDfFtT, mutans streptococci screening test and Lactobacilli colony counting were also done. Data analysis was accomplished by Axelsson's method. The result from the present study can be summarized as follows. 1. Laser, plasma light and halogen light could detect the initial carious lesions better than visual examination(p<0.05). 2. There was positive correlation between laser(r=0.42), plasma light(r=0.41), halogen light(r=0.39) and dBfFtT rate(p<0.01). 3. The specificity sensitivity and predictive value was showed highest value in laser, but was showed favorable value in plasma light and halogen light. In regard to above results, laser, plasma light and halogen light all considered to be reliable method for determining individual caries activity. And they were also considered to be practical method because it would be simple, inexpensive, and time saving method.

  • PDF

Spectroscopy of Visible Light Emitted from Plasma Occurred by Pulse Discharge (펄스형 방전플라스마에서 발생하는 가시광선의 분광특성 연구)

  • Choi, Woon Sang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.27-31
    • /
    • 1998
  • We investigated visible light radiated from Plasma focus device by time-resolved analyzed method and time-integrated analyzed method. Plasma focus consisted of two coaxial electrodes is a device that translated from electric energy of maximum 40 kV/20 kJ in capacitor banks into visible light by electric discharge. Spectral analysis is using Monochromator(f =0.5m). Time-resolved spectrum is analyzed with a oscilloscope the light pulse of constant wavelength and time-integrated spectrum does with densitometer the film which developed a constant range of wavelength. The optimum condition of visible emission was that the discharging voltage was 17kV and the gas pressure 0.5 torr Ar.

  • PDF

X-ray Radiation from Pulsed Discharge Plasma (펄스형 방전플라스마에서 발생하는 X선 측정)

  • Choi, Woon-Sang;Moon, Byeong-Yeon;Kwak, Ho-Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.311-315
    • /
    • 2006
  • We investigated X-ray radiated from the pulsed Plasma Focus device that translated from electric energy into electromagnetic wave by electric discharge. X-ray radiation is analysed by using pin photodiode and 0.5mm pinhole camera shielded by $25{\mu}m$ Be. The condition of X-ray radiation was that the discharging voltage was 15 kV and the working gas were 0.12 torr Argon. Reproducibility of X-ray radiation is investigated and X-ray temperature is calculated above 3keV.

  • PDF