• Title/Summary/Keyword: 플라스마(plasma)

Search Result 169, Processing Time 0.024 seconds

The simultaneous determination of germanium and selenium in plant by hydride vapour generator inductively coupled plasma mass spectrometry (HVG-ICPMS을 이용한 식물체 중 게르마늄과 셀레늄의 동시분석 연구)

  • Ham, Yong-Gyu;Kim, Bo-Kyong;Kwon, Young-Uk;Baek, Hyo-Hyu;Lee, Seok-Ki
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.159-167
    • /
    • 2011
  • In this study, the hydride vapour generator inductively coupled plasma mass spectrometry (HVGICPMS) was applied as the new analytical method to show the high accurate and reproductive data analysing the amounts of selenium and germanium being existed inside a system of plant. In order to decrease the interference effects, such as ion and molecular interference. Mini torch was used into the ICPMS instead of the conventional torch. At conditions of the different kinds and concentrations of acid solution, the different reductive conditions for composing hydride, and the different methods for making ash, the contents of selenium and germanium in lettuce were analysed. The inspection of yields and data comparison from SRM-1574 and -1570a were used for increasing the accuracy of this analysis.

Repair of Plasma Damaged Low-k Film in Supercritical Carbon Dioxide (초임계이산화탄소를 이용한 플라즈마 손상된 다공성 저유전 막질의 복원)

  • Jung, Jae-Mok;Lim, Kwon-Taek
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.191-197
    • /
    • 2010
  • Repair reaction of plasma damaged porous methyl doped SiOCH films was carried out with silylation agents dissolved in supercritical carbon dioxide ($scCO_2$) at various reaction time, pressure, and temperature. While a decrease in the characteristic bands at $3150{\sim}3560cm^{-1}$ was detectable, the difference of methyl peaks was not identified apparently in the FT-IR spectra. The surface hydrophobicity was rapidly recovered by the silylation. In order to induce effective repair in bulk phase, the wafer was heat treated before reaction under vacuum or ambient condition. The contact angle was slightly increased after the treatment and completely recovered after the subsequent silylation. Methyl groups were decreased after the plasma damage, but their recovery was not identified apparently from the FT-IR, spectroscopic ellipsometry, and secondary ion mass spectroscopy analyses. Furthermore, Ti evaporator was performed in a vacuum chamber to evaluate the pore sealing effect. The GDS analysis revealed that the open pores in the plasma damaged films were efficiently sealed with the silylation in $scCO_2$.

Phosphors for Plasma Display Panels (플라즈마 표시판용 형광체)

  • Kim, Chang Hong;Bae, Hyun Sook;Pyun, Chong Hong;Hong, Guang Yan
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.5
    • /
    • pp.588-595
    • /
    • 1998
  • Excitation and emission characteristics were reviewed for phosphors which were reported, applied, or suggested for the plasma display panel (PDP). Correlation of luminescence characteristics to the host crystal structure and the activator of the phosphor was explained. Improvements of the PDP phosphor for the practicality were considered.

  • PDF

Employing of Metal Negative Ion in Halogen Plasmas (염소저온플라스마에서 금속음이온의 이용)

  • Choi, Young-Il;Lee, Bong-Ju;Lee, Kyung-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.35-37
    • /
    • 2001
  • The Al etching was studied employing negative ions generated in the downstream $Cl_2$ plasma. In order to etch the Al film practically on an insulator covered electrode coupled with RF power, reduction of the negative self bias voltage (Vdc) was examined using a magnetic filter which trapped electrons. Addition of $SF_6$ and $H_2$ to a $Cl_2/BCl_3$ mixture reduced significantly Vdc.

  • PDF

A Study on the Analytical Method of Trace Metal Ions in Sea Water by Inductively Coupled Plasma - Mass Spectrometry using Solid-Liquid Extraction Technique (유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 해수중 미량금속의 분석에 관한 연구)

  • Lee, Won;Park, Kyung-Su;Kim, Eun Kyung;Hur, Young-Hoe
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.499-504
    • /
    • 1998
  • An analytical method for the simultaneous measurement of trace Cu, Sn, and Bi in sea water has been investigated by Inductively Coupled Plasma-Mass Spectrometry. Amberlite IRC-718 resin was used as a solid phase in solid-liquid extraction technique for the removal of matrix interferences such as Na, S, P, and other polyatomic ion species. Recoveries of 99.8% for Cu, 99.6% for Sn, and 97.9% for Bi were obtained for the standard spiked sample. The developed method was applied to analysis of trace metals in sea water.

  • PDF

무거운 이온을 포함하고 있는 플라스마에서 Pseudo-Potential Method와 1d PIC Simulation

  • Choe, Jeong-Rim;Min, Gyeong-Uk;Lee, Dae-Yeong;Ra, Gi-Cheol;Lee, Dong-Ryeol;Yu, Chang-Mo
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.43.4-44
    • /
    • 2009
  • electron, ion, heavy ion으로 구성 된 plasma에서 hump type과 kink type(double layer)의 electrostatic solitary waves이 존재할 수 있다는 것을 pseudopotential method를 이용한 결과와 1d PIC(Particle-In-Cell) simulation method의 결과에서 각각 확인하였다. 1d PIC simulation에서 초기에 각각의 입자 종(species; electron, ion, heavy ion)의 밀도섭동(density perturbation)은 Gaussian 형태로 주었으며, 각각의 입자들의 drift velocity는 각각의 plasma 입자 종들의 thermal velocity로 나란한 방향으로 주었다.

  • PDF

A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor - (이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 -)

  • ;Mizuki Yamaguma
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

Synchronous Roentgenographically Occult Lung Carcinoma Treated with Argon Plasma Coagulation in a Patient with Resectable Primary Lung Cancer (수술적 절제가 가능한 원발성 폐암 환자에서 병발된 방사선학적으로 발견되지 않은 동시성 원발성 폐암을 아르곤 플라스마 응고소작술로 치료한 1예)

  • Kwon, Mi-Hye;Kang, Mi-Il;Jeong, Ji-Hyun;Won, Hee-Kwan;Park, Hyun-Woong;Park, Jung-Ho;Kim, Sung-Tae;Kwon, Sun-Jung;Choi, Eugene;Na, Moon-Jun;Cho, Hyun-Min;Kim, Young-Jin;Kim, Yoon-Mee;Cho, Young-Jun;Son, Ji-Woong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.2
    • /
    • pp.137-141
    • /
    • 2008
  • We treated synchronous double primary lung cancers, where one site resulted from CIS disease, with lobectomy and argon plasma coagulation (APC) in a patient who couldn't tolerate pneumonectomy, which resulted in a reduction of the extent of surgery. APC could be a reasonable alternative for CIS disease of lung in inoperable patients.

Determination of Rare Earth Elements by Inductively Coupled Plasma Mass Spectrometry with Introduction of Organic Phase Using Ultrasonic Nebulizer (초음파 분무기를 이용한 유기상의 주입에 의한 희토류 원소의 유도결합 플라스마 질량분석법적 정량)

  • Lee, Sang Hak;Son, Bum Mok
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • Analytical method to determine rare earth elements which were extracted to organic phase by inductively coupled plasma mass spectrometry(ICP-MS) was investigated. Organic phase which had extracted rare earth elements was directly aspirated into ICP-MS by ultrasonic nebulizer(USN) in order to reduce solvent load to the plasma. Then, the count rate increased when MIBK(methyl isobutyl ketone) was added to EtOH(ethanol) but decreased when 0.03 M HEH(2-ethylhexyl-2-ethylhexyl phosphonic acid, $P_{507}$, PC88A) was added to solvent which mixed MIBK with EtOH. The optimal temperatures of desolvation system were -10 $^{\circ}C$ for the condenser and 150 $^{\circ}C$ for the heating tube. The optimal nebulizer flow rate which gave maximum count rate and minimum reflect power was 0.7 L/min. The optimal pH and extraction time were 4.3 and 10 min for MIBK-0.03 M HEH system. Detection limits which were obtained through calibration curves at the range of 0.2 ${\sim}$ 20 ng/mL were 0.02 ${\sim}$ 0.05 ng/mL under the optimal experimental conditions.

Elemental Analysis of Coal by Inductively Coupled Plasma Mass Spectrometry (誘導結合플라스마 質量分析法에 의한 石炭의 元素 分析)

  • 이용근;고인형;이동수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.155-161
    • /
    • 1992
  • A simple, fast yet sensitive method is described for the determination of fifty elements in coal by inductively coupled plasma mass spectrometry. The method involves complete dissolution of coal with mixed acid $(HNO_3, HF, HClO_4)$ in hish pressure Teflon bomb and subsequent inductively coupled plasma mass spectrometric(ICP-MS) measurement. The accuracy of the method, being evaluated by the analysis of NIST SRMs (1632a, 1632b) is better than 20% RSD for most elements. The limits of detection defined by two times $\sigma$ (standard deviation of operational blank) are in order of sub-ppm to ppm, which are low enough to quantitate most elements. However, the determiantions for few elements such as V, As, Se are severely interfered by molecular ions such that their accurate determiantions are not possible. Analytical results for twentyon coals from eight countries including six ones world major coal producing, Korea, Japan, China, I.C.S., U.S.A., Canada, Australia, and South Africa are presented. While the results for major elements agree well with the existing ones, those for a few trace elements disagree considerably. The existing values are considerably higher. It is not possible to judge which are more accurate. However, the exisisting values are more likely to be errorous inasmuch as they are obtained without using high purity reagents and clean laboratory techniques.

  • PDF