• Title/Summary/Keyword: 프로브데이터

Search Result 57, Processing Time 0.02 seconds

Performance Analysis of Access Channel Decoder Implemeted for CDMA2000 1X Smart Antenna Base Station (CDMA2000 1X 스마트 안테나 기지국용으로 구현된 액세스 채널 복조기의 성능 분석)

  • 김성도;현승헌;최승원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2A
    • /
    • pp.147-156
    • /
    • 2004
  • This paper presents an implementation and performance analysis of an access channel decoder which exploits a diversity gain due to the independent magnitude of received signals energy at each of antenna elements of a smart antenna BTS (Base-station Transceiver Subsystem) operating in CDMA2000 1X signal environment. Proposed access channel decoder consists of a searcher supporting 4 fingers, Walsh demodulator, and demodulator controller. They have been implemented with 5 of 1 million-gate FPGA's (Field Programmable Gate Array) Altera's APEX EP20K1000EBC652 and TMS320C6203 DSP (digital signal processing). The objective of the proposed access channel decoders is to enhance the data retrieval at co]1-site during the access period, for which the optimal weight vector of the smart antenna BTS is not available. Through experimental tests, we confirmed that the proposed access channel decoder exploitng the diversity technique outperforms the conventional one, which is based on a single antenna channel, in terms of detection probability of access probe, access channel failure probability, and $E_{b/}$ $N_{o}$ in Walsh demodulator.r.r.

Characteristics of Sequentially-Rotated Array Antenna by Varying Sequential Array Parameter (배열 정수 변화에 의한 순차 회전 배열 안테나의 특성)

  • Han, Jeong-Se;Lee, Hyun-Sung;Seo, Dong-Kug;Park, Byoung-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.11
    • /
    • pp.76-83
    • /
    • 2007
  • In the sequentially rotated array antennas, the characteristics of antenna gain, axial ratio and cross polarization have been analyzed with a varying of sequential array constant(number of array element, figure of rotation) respectively. Where the antenna element of array is a probe feeding, LHCP truncated microstrip antenna whose resonant frequency is in 11.85GHz. The simulation results of 23 SRA antennas((M=2, 3, 4, 6, 8), $(1\leqP\leqM)$) has shown as follows. The widest 3dB bandwidth of axial ratio appears at P=2 which is in-dependant of M, the highest antenna gain appears when a sequential array constant has a pair of (2, 1), (3, 2), (4, 1), (6, 3), (8, 1) respectively. Specially, all of the SRA antenna appear very poor characteristics in case of M=P. Therefore the SRA antenna has to be designed as selecting a optimal sequential array constant among a lot of simulation data.

Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo (고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징)

  • Cho, Han Saem;Jang, Sun-Joo;Oh, Wang-Yuhl
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • Intravascular optical coherence tomography (OCT) enables imaging of the three-dimensional (3D) microstructure of a blood vessel wall. While 3D vascular visualization provides detailed information of the vessel wall and intraluminal structures, a longitudinal imaging pitch that is several times bigger than the imaging resolution of the system has limited true high-resolution 3D imaging. In this paper we demonstrate high-speed intravascular OCT in vivo, acquiring images at a rate of 350 frames per second. A 47-mm-long rabbit aorta was imaged in 3.7 seconds, after a short flush with contrast agent. The longitudinal imaging pitch was 34 micrometers, comparable to the transverse imaging resolution of the system. Three-dimensional volume rendering showed greatly enhanced visualization of tissue microstructure and stent struts, relative to what is provided by conventional intravascular imaging speeds.

Integrated Assessment for Commercialization of Road Hazardous Information Colleted by Commercial Vehicles (사업용 차량 기반 도로위험정보 제공의 상용화를 위한 통합 평가)

  • Yoo, Kyung-su;Chung, Kyungmin;Chae, Chandle
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.2
    • /
    • pp.30-42
    • /
    • 2021
  • The amount of compensation and the number of cases owing to car damage from pot holes on highways across the country increased by about 4.2 times and 3.5 times, respectively, in 2019 compared to 2015. Due to the increase in damage caused by these road hazards, the Ministry of Land, Infrastructure and Transport is developing technologies and services that can collect road hazard information by using devices on commercial vehicles (DTGs, black boxes, ADASs). In preparation for the development of these technologies, this study conducted an integrated assessment of algorithms developed for interrupted-flow and uninterrupted-flow traffic under three scenarios in order to provide road hazard information to drivers and road managers. As a result, the overall accuracy of the integrated assessment was derived at 81.88%. Errors generated in this integrated assessment reflect only missing data in less than 1 minute, GPS coordinate location and algorithm related errors, taking into account the purpose and assumptions of the assessment. Among them, we derive an accuracy of 90.15%overall by calibrating GPS error data. The results of this study can be used as basic data for improving the accuracy of location-based information collected by commercial vehicles and for policy development.

A Prostate Segmentation of TRUS Image using Average Shape Model and SIFT Features (평균 형상 모델과 SIFT 특징을 이용한 TRUS 영상의 전립선 분할)

  • Kim, Sang Bok;Seo, Yeong Geon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.3
    • /
    • pp.187-194
    • /
    • 2012
  • Prostate cancer is one of the most frequent cancers in men and is a major cause of mortality in the most of countries. In many diagnostic and treatment procedures for prostate disease, transrectal ultrasound(TRUS) images are being used because the cost is low. But, accurate detection of prostate boundaries is a challenging and difficult task due to weak prostate boundaries, speckle noises and the short range of gray levels. This paper proposes a method for automatic prostate segmentation in TRUS images using its average shape model and invariant features. This approach consists of 4 steps. First, it detects the probe position and the two straight lines connected to the probe using edge distribution. Next, it acquires 3 prostate patches which are in the middle of average model. The patches will be used to compare the features of prostate and nonprostate. Next, it compares and classifies which blocks are similar to 3 representative patches. Last, the boundaries from prior classification and the rough boundaries from first step are used to determine the segmentation. A number of experiments are conducted to validate this method and results showed that this new approach extracted the prostate boundary with less than 7.78% relative to boundary provided manually by experts.

Development of Portable Multi-function Sensor (Mini CPT Cone + VWC Sensor) to Improve the Efficiency of Slope Inspection (비탈면 점검 효율화를 위한 휴대형 복합센서 개발)

  • Kim, Jong-Woo;Jho, Youn-Beom
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • In order to efficiently analysis the stability of a slope, measuring the shear strength of soil is needed. The Standard Penetration Test (SPT) is not appropriate for a slope inspection due to cost and weights. One of the ways to effectively measure the N-value is the Dynamic Cone Penetration Test (DCPT). This study was performed to develop a minimized multi-function sensors that can easily estimate CPT values and Volumetric Water Content. N value with multi-fuction sensor DCPT showed -2.5 ~ +3.9% error compared with the SPT N value (reference value) in the field tests. Also, the developed multi-fuction sensor system was tested the correlation between the CPT test and the portable tester with indoor test. The test result showed 0.85 R2 value in soil, 0.83 in weathered soil, and 0.98 in mixed soil. As a result of the field test, the multi-function sensor shows the excellent field applicability of the proposed sensor system. After further research, it is expected that the portable multi-function sensor will be useful for general slope inspection.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.