• Title/Summary/Keyword: 프로그램의 유용성

Search Result 643, Processing Time 0.03 seconds

Detection of Cancer with PET and PET/CT in Asymptomatic Volunteers (무증상 성인에서 PET과 PET/CT를 이용한 암 진단)

  • Chung, Ji-In;Cho, Han-Byoul;Shim, Jae-Yong;Choi, Joon-Young;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Yoon-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.526-534
    • /
    • 2009
  • Purpose: We retrospectively investigated the diagnostic performance of $^{18}F$-fluorodeoxyglucose positron emission tomography (PET) and PET/CT for cancer detection in asymptomatic health-check examinees. Materials and Methods: This study consisted of 5091 PET or PET/CT conducted as part of annual health examination at one hospital from March 1998 to February 2008. To find the incidence of cancers, medical records of the subjects were thoroughly reviewed for a follow-up period of one year. The patterns of formal readings of PET and PET/CT were analyzed to assess the sensitivity and specificity for cancer detection. The histopathology and stage of the cancers were evaluated in relation to the results of PET. Results: Eighty-six cancers (1.7%) were diagnosed within one year after PET or PET/CT. When PET and PET/CT results were combined, the sensitivity was 48.8% and specificity was 81.1% for cancer detection. PET only had a sensitivity of 46.2% and a specificity of 81.4%, and PET/CT only had a sensitivity of 75.0% and a specificity of 78.5% respectively. There were no significant differences in cancer site, stage and histopathology between PET positive and PET negative cancers. In 19.3% of formal readings of PET and PET/CT, further evaluation to exclude malignancy or significant disease was recommended. Head and neck area and upper gastrointestinal tract were commonly recommended sites for further evaluation. Conclusions: PET and PET/CT showed moderate performance for detecting cancers in asymptomatic adults in this study. More experience and further investigation are needed to overcome limitations of PET and PET/CT for cancer screening.

Music Activities for Facilitation of Developmental Domains for Children from Age Three to Six (3-6세 유아의 영역별 발달 촉진을 위한 단계별 음악치료교육 활동 연구)

  • Lee, Su yeon
    • Journal of Music and Human Behavior
    • /
    • v.3 no.1
    • /
    • pp.29-62
    • /
    • 2006
  • The early development of an infant is crucial due to the enormous impact it has throughout an infant's life. Therefore, it is important to understand the development process of an infant and provide a high-quality educational environment so that an infant can progress at an innate pace to learn how to exercise, understand, speak, socialize, and empathize as well as having a balanced growth. When educating an infant, joy is a substantial factor in the formation of trust and development of relationship that makes education efficient. Music can be an effective means to offer a fun atmosphere vto the infant in which it stimulates active participation of the infant and development of a variety of dimensions to the infant's development. Also, the purpose of music therapy education is utilizes to plan for the different age groups' level of understanding of music and allow the infant to have a positive experience and develop properly. The purposes of this study are as following: to examine characteristics according to an infant' developmental steps thoroughly, to suggest interventions using music therapy education to stimulate development of an infant, to prove that infants age 3 to 6 obtain the necessary ability and skill through the effective educational therapy through music, and finally to create a music program for educating infants or music therapy. This study has examined theories of the music approach targeting infants age 3 to 6 and made character observations of infant' Motor, Cognition, Communication, Socialization, and Emotions. With the basis of the above theory, the different levels of development has been divided, specific goals has been set up according to the levels, and various music therapy education for infants have been created. The music therapy education activity has been approved by five professionals who are renown in their specific field. They made comments that the development levels were properly divided in the paper. They also commented that the music program is adequate for achieving the goal of each developmental level and it stimulates the different levels of an infant's development. In conclusion, the study reflects that the approach of music therapy education stimulates the different levels of infant development. Music therapists can utilize this music program to help handicapped children identify characteristics of progress and develop at their own ability.

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

The Evaluation of Resolution Recovery Based Reconstruction Method, Astonish (Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가)

  • Seung, Jong-Min;Lee, Hyeong-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2011
  • Objective: The 3-dimensional reconstruction method with resolution recovery modeling has advantages of high spatial resolution and contrast because of its precise modeling of spatial blurring according to the distance from detector plane. The aim of this study was to evaluate one of the resolution recovery reconstruction methods (Astonish, Philips Medical), compare it to other iterative reconstructions, and verify its clinical usefulness. Materials and Methods: NEMA IEC PET body phantom and Flanges Jaszczak ECT phantom (Data Spectrum Corp., USA) studies were performed using Skylight SPECT (Philips) system under four different conditions; short or long (2 times of short) radius, and half or full (40 kcts/frame) acquisition counts. Astonish reconstruction method was compared with two other iterative reconstructions; MLEM and 3D-OSEM which vendor supplied. For quantitative analysis, the contrast ratios obtained from IEC phantom test were compared. Reconstruction parameters were determined by optimization study using graph of contrast ratio versus background variability. The qualitative comparison was performed with Jaszczak ECT phantom and human myocardial data. Results: The overall contrast ratio was higher with Astonish than the others. For the largest hot sphere of 37 mm diameter, Astonish showed about 27.1% and 17.4% higher contrast ratio than MLEM and 3D-OSEM, in short radius study. For long radius, Astonish showed about 40.5% and 32.6% higher contrast ratio than MLEM and 3D-OSEM. The effect of acquired counts was insignificant. In the qualitative studies with Jaszczak phantom and human myocardial data, Astonish showed the best image quality. Conclusion: In this study, we have found out that Astonish can provide more reliable clinical results by better image quality compared to other iterative reconstruction methods. Although further clinical studies are required, Astonish would be used in clinics with confidence for enhancement of images.

  • PDF

Texture Feature analysis using Computed Tomography Imaging in Fatty Liver Disease Patients (Fatty Liver 환자의 컴퓨터단층촬영 영상을 이용한 질감특징분석)

  • Park, Hyong-Hu;Park, Ji-Koon;Choi, Il-Hong;Kang, Sang-Sik;Noh, Si-Cheol;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • In this study we proposed a texture feature analysis algorithm that distinguishes between a normal image and a diseased image using CT images of some fatty liver patients, and generates both Eigen images and test images which can be applied to the proposed computer aided diagnosis system in order to perform a quantitative analysis for 6 parameters. And through the analysis, we derived and evaluated the recognition rate of CT images of fatty liver. As the results of examining over 30 example CT images of fatty liver, the recognition rates representing a specific texture feature-value are as follows: some appeared to be as high as 100% including Average Gray Level, Entropy 96.67%, Skewness 93.33%, and Smoothness while others showed a little low disease recognition rate: 83.33% for Uniformity 86.67% and for Average Contrast 80%. Consequently, based on this research result, if a software that enables a computer aided diagnosis system for medical images is developed, it will lead to the availability for the automatic detection of a diseased spot in CT images of fatty liver and quantitative analysis. And they can be used as computer aided diagnosis data, resulting in the increased accuracy and the shortened time in the stage of final reading.

Verification Effect of Family Resilience Model of married immigrant women (결혼이주여성의 가족 회복력 모형검증)

  • Oh, Jaewoo;Park, Insook
    • Journal of Digital Convergence
    • /
    • v.11 no.5
    • /
    • pp.355-370
    • /
    • 2013
  • This study was aimed at the married immigrant women and was attempted to provide the basic data of the nursing practice useful in identifying the relationship aspects and the influence of resilience factor and promoting the family adaptation. This study was conducted for the married immigrant women who were located in urban-rural complex area around Daejeon city and in Chungnam region, and the multi-cultural families supporting program of community welfare halls among those who had resided over 1 year in Korea. The data was collected from Feb, 2012 to July, 2012 and in the end, 216 questionnaires were made the subjects of data analysis. For the collected data, frequency analysis, percentage, ANOVA, t-test and correlation analysis were conducted using SPSS, LISREL. The overall index of hypothesis model showed a good congruence like ${\chi}^2$ = .06 (p= .812), df=1, ${\chi}^2$(df)=.06, GFI=1.0, AGFI= 1.0, SRMR=.002, NFI= 1.0, NNFI=1.0, RMSEA=0.000, CN=266. Looking at the results of hypothesis testing suggested by the model, the variables which affected the family adaptation were family stress and parenting stress, while social support, family hardness, problem solving communication, and problem solving coping didn't affect the family adaptation. It is considered that based on the results of this study, nursing intervention which helps the family adaptation of the married immigrant women who are in a crisis situation must be done with a program which can help them have a positive view on the stress situation and reduce the stress happening in the family relationship and parenting.

MR Imaging Measurement of the Femoral Anteversional Angle as a PACS Image Viewer (MR 영상에서의 PACS Image Viewer를 이용한 대퇴골 전염각 측정)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2003
  • The accurate measurement of the femoral anteversion is very important to the practice of orthopedic and osteotomy. It is measured by means of the axis of head and neck of the femur and the knee axis. At the present time, widely used computed tomography method of measuring anteversion on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In September and October 2002, 5 patients 28 to 36 years of age were randomly selected from Seoul National University Hospital. The purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing PACS image viewer program in the MR imaging. Significant difference was observed between the right and left side the image viewer measurement of femoral anteversion. In conclusion, MR imaging very usefulness in the measured the angle of the femoral anteversion.

  • PDF

Effect of Upper Extremity Function and Activities of Daily Living of Mirror Therapy on Patients Who Have a Stroke, with or without Unilateral Neglect (편측무시 유무에 따른 거울치료가 뇌졸중 환자의 상지기능과 일상생활활동에 미치는 효과 비교)

  • Lee, Seul-A;Kim, Hee-Jung;Hong, Ki-Hoon;Lee, Chun-Yeop
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.1
    • /
    • pp.33-45
    • /
    • 2014
  • Objective : We tested the effect of mirror treatment on patients with and without unilateral neglect over a period of 4 weeks. We also wanted to know the effect of mirror treatment with regards to improving upper extremity function and dealing with activities of daily living. Methods : Subjects were 10 hemiplegia patients with unilateral neglect and 10 hemiplegia patients without unilateral neglect. They visited the department of occupational therapy. We performed mirror treatment for 30 minutes, 5 times a week for 4 weeks. We used Albert Test to compare our results from before and after the treatment, Fugl-Meyer motor function Assessment(FMA) and Box & Block Test(BBT) for upper extremity function, and Functional Independence Measure(FIM) for activities of daily living. Results : The results showed that mirror treatment had an effect on stroke patients with unilateral neglect. The treatment also had an effect on upper extremity function and activities of daily living regardless of unilateral neglect. Conclusion : The mirror treatment showed improvements on upper extremity function and activities of daily life as well as a reduction in the unilateral neglect after a stroke. In conclusion, the mirror treatment is useful for recovering function and improvement and for helping the patients complete activities of daily living.

  • PDF

Estimation of Number of Synapses on a Neuron in the Brain Using Physical Bisector Method (Physical disector를 이용한 신경세포 및 신경연접 수의 측정)

  • Lee, Kea-Joo;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.36 no.2
    • /
    • pp.83-91
    • /
    • 2006
  • The number and structure of synapses are dynamically changed in response to diverse physiological and pathological conditions. Since strength of synaptic transmission is closely related to the synaptic density on a neuron, both synaptogenesis and synapse loss may play important roles in controlling neuronal activity. Thus it is essential to estimate the number of synapses using an accurate quantitative method for better understanding of the numerical alteration of synapses under terrain experimental conditions. We applied physical disector principle to estimating the number of synapses per neuron in the dentate gyrus of adult mice. First, we measured the numerical density of granule cells using the physical disector principle. Second, the density of medial perforant path to granule cell synapses was estimated using the bidirectional physical disector. Then, the volume ratio of molecular layer to granule cell layer was measured. With these numerial values, we successfully calculated the number of synapses per neuron. Individual granule cells have approximately 6500 synapses in the dentate gyrus of adult mice $(6,545{\pm}330)$, which are comparable to those of other researchers. Our results showed that the estimation of synapse numbers per neuron using the physical disector principle would provide accurate and precise information on the numerical alteration of synapses in diverse physiological and pathological conditions. Following analyses of synapse numbers using this method will contribute to the better understanding of structural synaptic plasticity in a variety of experimental animal models.

The Design of Reconstruction Filter for the Order Tracking of the Rotating Machinery (회전기기 진동의 Order Tracking을 위한 재합성 필터의 설계)

  • 정승호;박영필;이상조
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.95-98
    • /
    • 1991
  • 회전 기기의 이상으로 인하여 발생하는 진동은 축 회전속도의 고주파 성분 (super-harmonic)이나 또는 분수조파 성분(sub-harmonic)으로 나타나는 경 우가 대부분이기 때문에 회전기기의 진동을 주파수 영역에서 해석함에 있어 파워 스펙트럼의 주파수 축을 Hz로 나타내기보다는 축 회전속도의 order로 써 나타내는 것이 매우 유용하다. 스펙트럼을 order로써 나타내기 위해서는 샘플링 시간을 축 회전속도와 동기(synchronization)시켜야 하는데 이 방법으 로는 회전축에 엔코더(encorder)를 부착하여 엔코더에서 발생하는 펄스 신호 를 이용하여 샘플링하는 방법과 order tracking 필터를 이용하는 방법이 있 다. 그러나 전자의 방법은 원하는 회전축마다 엔코더를 부착하여야 하며 경 우에 따라서는 엔코더를 부착하기가 어려운 경우도 있으며, 회전기기의 운전 개시나 종료시처럼 회전속도가 급격히 변화하는 경우에는 낮은 주파수에서 중첩(aliasig)에 의한 오차가 수반될 수도 있다. 후자의 방법은 order tracking 필터 이외에도 여러 부수장비가 필요하며 기준 주파수(즉 회전속 도)가 급격히 변화하는 경우 PLL(phase locked loop)에서 tracking 오차가 발생된다. 최근에 발표된 논문에서 일정한 시간간격으로 샘플링한 데이터들 로부터 신호를 재합성하여 회전축의 속도와 동기가 되도록 재 샘플링함으로 서 스펙트럼의 주파수를 회전속도의 order로써 나타내는 방법을 제시하였다. 그러나 위 논문에서는 신호의 재합성에 필요한 재합성 필터(reconstruction filter)의 설계 방법에 대하여 구체적인 언급이 없이 다만 결과만을 논하였다. 따라서 본 논문에서는 재합성 필터의 설계 방법에 대하여 구체적인 방법을 제시하고 또한 동기화 샘플링의 장점 및 고려 사항에 대하여 고찰하였다. 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The re

  • PDF