• Title/Summary/Keyword: 풍력 발전기 블레이드 구조

Search Result 50, Processing Time 0.022 seconds

Structural Design and Proof Test of a 2MW Wind Trubine Blade (2MW 로터 블레이드 구조설계 및 인증시험)

  • Bang, Jo-Hyug;Kim, Yang-Soo;Ryu, Ji-Yune;Kim, Doo-Hoon;Park, Sun-Ho;Park, Byoung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.349-352
    • /
    • 2007
  • A GFRP based composite blade was developed for a 2MW wind energy conversion system of type class IIA. The blade sectional geometry was designed to have a general shell-spar and shear web structure. The load cases specified in the IEC61400-1 international specification were considered. For withstanding all relevant extreme loads, the structural analysis for the complete blade was performed using a commercial FEM code. The static load carrying capacity, blade tip deflection and natural frequencies were evaluated to satisfy the strength and stability requirements in accordance with the IEC61400-1 and GL Regulations. The prototype blade was passed the structural proof test for GL certification.

  • PDF

Structural Optimization for Small Scale Vertical-Axis Wind Turbine Blade using Response Surface Method (반응표면법을 이용한 소형 수직축 풍력터빈 블레이드의 구조 최적화)

  • Choi, Chan-Woong;Jin, Ji-Won;Kang, Ki-Weon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.22-27
    • /
    • 2013
  • The purpose of this paper is to perform the structural design of the small scale vertical-axis wind turbine (VAWT) blade using a response surface method(RSM). First, the four design factors that have a strong influence on the structural response of blade were selected. Analysis conditions were calculated by using the central composite design(CCD), which is a typical design of experiment for the response surface method(RSM). Also, the significance of the central composite design(CCD) was verified using analysis of variance(ANOVA). The finite element analysis was performed for the selected analytical conditions for the application of response surface method(RSM). Finally, a optimization problem was solved with a objective function of blade weight and a constraint of allowable stress to achieve a optimal structural design of blade.

A Study on the Structure of Hybrid Magnetic Gear with Armature Type Rotor (전기자 형태의 회전자를 갖는 하이브리드 마그네틱 기어의 구조에 관한 연구)

  • Gim, Chan-Seung;Park, Eui-Jong;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1235-1242
    • /
    • 2018
  • When the wind speed changes rapidly, the wind turbine is stopped for the safety of the power system and the mechanical system. At that moment, the wind turbine gearbox is damaged and broken due to the contact load of the gearbox. In addition, the problems such as increasing frictional heat and deteriorate of the brake occur, because the power of the blades is transmitted directly to the brakes. This paper proposes a hybrid magnetic gear shape that solves the problem caused by the contact of the mechanical gear, which is the power transmission device of the wind power generation system, and the power cutoff system. The shape of the hybrid magnetic gearsuitable for the wind power generation system is derived through the torque and loss analysis according to the shape of the hybrid magnetic gear by using the two dimensional finite analysis method.

Design of Individual Pitch Control and Fatigue Analysis of Wind Turbine (풍력발전시스템 개별피치제어설계 및 피로해석에 관한 연구)

  • Jeon, Gyeong Eon;No, Tae Soo;Kim, Guk Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Structural loading on a wind turbine is due to cyclic loads acting on the blades under turbulence and periodic wind field. The structural loading generates fatigue damage and fatigue failure of the wind turbine. The individual pitch control(IPC) is an efficient control method for reducing structural loading. In this paper, we present an IPC design method using Decentralized LQR(DLQR) and Disturbance accommodating control(DAC). DLQR is used for regulating rotor speed and DAC is used for canceling out disturbances. The performance of the proposed IPC is compared with CPC, which was designed with a gain-scheduled PI controller. We confirm the effect of fatigue load reduction with the use of damage equivalent load(DEL).

A Study on Dynamic Characteristics Analysis of Hybrid Wind Power Blades according to Material Properties Method (물성치 적용 기법에 따른 하이브리드 풍력 블레이드 동적특성 해석에 관한 연구)

  • Kang, Byong-Yun;Han, Jeong-Young;Hong, Cheol-Hyun;Moon, Byong-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.5-11
    • /
    • 2012
  • In this paper, the heat transfer coefficient measurement techniques using TSP(temperature sensitive paint) were introduced and the results of a comparative study on the heat transfer coefficient measurement by steady state and transient TSP techniques were discussed. The distributions of heat transfer coefficient by a single $60^{\circ}$ inclined impingement jet on a flat surface were measured by both techniques. Tested Reynolds number based on the jet diameter (d) was 30,000 and the distance between jet exit and target plate (L) was fixed at 10d. Results showed that the measured Nusselt number by both techniques indicated significant difference except near the center of impingement jet. Also, the heat transfer coefficients measured by the transient TSP technique were affected by the reference temperature of the jet. Based on the measured data, characteristics of both TSP techniques were analyzed and suggestions for applying them were also given.

A Study of the FE Analysis Technique of Hybrid Blades for Large Scale Wind-Turbine (대형 풍력발전기용 하이브리드형 블레이드 구조해석)

  • Kang, Byong-Yun;Kim, Yun-Hae;Kim, Do-Wan;Kim, Myung-Hun;Han, Jeong-Young;Hong, Cheol-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.61-66
    • /
    • 2011
  • According to recent figures, 35% of the world's blades are made using prepreg blades, by Vestas and Gamesa. They are the most advanced in the market today. In this study, we investigated the validity of the finite element method (FEM) applied to an FE analysis of a hybrid composite wind-turbine blade. Two methods were suggested for a composite FE analysis: using the equivalent properties of the composite or using stacking properties. FE analysis results using the stacking properties of the composite were in good agreement with results of using the equivalent properties. The difference between FE results was approximately 0.6~13.3%.

Structural Characteristics Evaluation of the Injection Spiral Blade Used in Small Wind Turbines under Operating Conditions (운전하중 조건에서 소형 풍력 발전기용 사출 나선형 블레이드 구조특성 평가)

  • Gil, Young-Uk;Jo, Young-Kwan;Ji, Ho-Seong;Yang, Hyoung-Keun;Baek, Joon-Ho;Je, Duk-Geun;Jeong, Ho-Seung;Park, Sang-Hu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.38-46
    • /
    • 2020
  • The purpose is to evaluate the structural characteristics of 750 mm diameter injection spiral blades under various operating conditions. A fiber-glass reinforced polypropylene material was employed to the injection blades, and mechanical tests on two kinds of glass-reinforced polypropylene were performed to evaluate the mechanical properties and to select a suitable candidate material. Also, three kinds of spiral blade geometries were studied to observe the influence of fixing rods between blades. For this, structural analyses were conducted to understand the role of fixing rods under a range of rotating speed. In addition, modal analysis was performed to confirm the resonance in the operating speed range. One-way fluid-structure interaction (FSI) analysis was carried out to know its mechanical integrity under dangerous wind speed conditions. Through this work, the structural characteristics of the proposed spiral blade geometries were studied under various operating conditions, and the requirements of mechanical properties of blades were determined.

Equivalent Structural Modeling of Wind Turbine Rotor Blade (풍력발전기 로터 블레이드의 등가 구조모델 수립)

  • Park, Young-Geun;Hwang, Jai-Hyuk;Kim, Seok-Woo;Jang, Moon-Seok;Bae, Jae-Sung
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.14 no.4
    • /
    • pp.11-16
    • /
    • 2006
  • The wind turbine rotor blade is faced with various aeroelastic problem as rotor blades become bigger and lighter by the use the composite material. The aeroelastic analysis of a wind turbine rotor blade requires its aerodynamic model and structural model. For effective aeroelastic analysis, it is required the simple and effective structural model of the blade. In the present study, we introduce the effective equivalent structural modeling of the blade for aeroelastic analysis. The equivalent beam model of the composite blade based on its 3D finite element model is established. The free vibration analysis shows that the equivalent beam model of the blade is equivalent to its 3D finite element model.

  • PDF

Investigation on Structural Design and Impact Damage for a Small Wind Turbine Blade (소형 풍력발전기 블레이드의 구조설계 및 충격손상 안전성 연구)

  • Kong, Changduk;Choi, Suhyun;Park, Hyunbum
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Recently the wind energy has been alternatively used as a renewable energy resource instead of the mostly used fossil fuel due to its lack and environmental issues. This work is to propose a structural design and analysis procedure for development of the low noise 100W class small wind turbine system which will be applicable to relatively low speed region like Korea and for the domestic use. Structural analysis including load cases, stress, deformation, buckling, vibration and fatigue life was performed using the Finite Element Method, the load spectrum analysis and the Miner rule. In order to evaluate the designed structure, the structural test was carried out and its test results were compared with the estimated results. In addition, the blade should be safe from the impact damage due to FOD(Foreign Object Damage) including the bird strike. In order to analize the bird strike penomena on the blade, MSC. Dytran was used, and the applied method Arbitrary Lagrangian-Eulerian was evalud by comparison with the previous study results.

  • PDF

An Analysis on the Value Chain and the Value System of the Korean Wind Power Industry (한국 풍력산업의 가치사슬 및 가치시스템 분석)

  • Ryu, Jae-Ho;Choi, Ta-Gwan;Park, Jung-Gu
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.46-57
    • /
    • 2014
  • This study analyzes whether the value-added structure of Korean wind power industry exhibits a virtuous cycle through the value chain(VC) within wind power firms and the value system(VS) among the wind power industries, using a regression analysis based on a survey about Korean wind power companies. According to the VC, the government's R&D support is analyzed to have contributed to an increase in the R&D investments of the wind power companies. An increase in corporates' R&D investments has led to an increase in corporates' R&D outputs, and in turn, induced a remarkable increase in the amounts of production. But an increase in production has not led to a decrease in the costs of production, not resulting in an increase in profit rates per sales amount. In addition, while an increase in profit rates is analyzed to have contributed to an increase in production, this did not induce further investments in corporate's R&D. The virtuous cycle of the value chain in Korean wind power firms is, therefore, analyzed to be weak. Next, the VS is analyzed by dividing the whole chain into the system group including rotor blades, gear boxes, and power generators, and the structure group, such as towers. Two groups are analyzed to have mutually positive effects in the processes of the government's support for corporates' R&D, corporates' investment in R&D, R&D outputs, and profit rates per sales amount. Such mutual positive effects are, however, not found in the processes of the amounts of production and the costs of production. These results demonstrates that the value system of Korean wind power industry is not completed. This study has a policy implication to need further efforts to create the virtuous cycle in the VC and VS of Korean wind power industry.