• Title/Summary/Keyword: 표준 머리모형

Search Result 3, Processing Time 0.016 seconds

A Study of Standard Head Model for Korean Adults by 3D Measurement (한국 성인의 3차원 표준 머리모형)

  • Kim Hye-Soo;Yi Kyong-Hwa;Park Se-Jin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.4 s.152
    • /
    • pp.542-553
    • /
    • 2006
  • The purpose of this study were to analyse of craniofacial shape by 3D and to develope of head models for Korean adults with gender and age groups. The 3D measurement technique adapted in this study was a novel approach compared that the same technique has been commonly used in measuring human bodies. The data and the model of head analysis can be used as a basic reference in developing various head related items such as hat, helmet, gas mask, ear phone, and etc. In this study, heads of 836 Korean adults were measured in 3D, analyzed by statistical methods, and modelized in 3D by gender and age groups. From the basic statistical data analysis, vertex-tragion and the length between the pupils were the longest in their twenties for both men and women, and grew shorter in elderly groups. In all categories, a significant difference appeared between men and women in their 20's, but the differences were less noticeable in elderly groups. Compared to the one size standard head model of the Korea Occupational Safety and Health Agency, the above three-dimensional standard head model would provide a more through fit because gender and age groups were sub-divided and analyzed in 3D.

Rapid Prototyping을 이용한 임플란트 생성

  • 방철배;김영호;강석호
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1997.10a
    • /
    • pp.37-40
    • /
    • 1997
  • RP(Rapid Prototyping) 기술은 점점 그 활용범위를 넓혀가는 추세이며, 의료분야에서도 임플란트의 제작등에 RP 기술의 도입이 시도되고 있다. 뼈나 치아 등의 인체부속물들은 속성상 직접 그 형태를 파악하기가 힘들고, 따라서 그 대체물인 임플란트의 제작을 위해 MRI나 CT등의 장비가 사용되고 있다. 의료분야에까지 이르는 RP의 활발한 활용에도 불구하고, 아직 국내에서는 RP에 대한 인식이 부족하고 그 활용에 대한 연구가 거의 없는 상황이다. 본 논문은 MRI, CT등의 2차원 평면데이터로부터 직접 RP 기계의 표준입력화일인 STL 파일을 생성시키기 위한 방법을 제시한다. 그리고 MRI로 스캐닝된 사람의 머리뼈 형상을 삼각메쉬 형태의 STL 파일로 변화하여 RP 기계를 통한 실물 모형 제작이 가능하도록 한 예를 설명하였다.

  • PDF

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF