• Title/Summary/Keyword: 표준마감재

Search Result 15, Processing Time 0.028 seconds

Evaluation of Floor Impact Sound by Floor Coverings in Standard Test Building (표준시험동에서 바닥마감재에 따른 바닥충격음 특성평가)

  • Kim, Hak-Cheon;Kim, Yong-Gil;Kim, Sang-Chul;Lee, Hyun-Lyul;Cho, Hyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.439-440
    • /
    • 2008
  • Five floor coverings were tested with three different types of floor structures in the standard test building in order to evaluate the effectiveness of the floor impact sound reduction. The level of floor impact sound reduction is influenced by not only the types of floor coverings but interrelationship between the floor coverings and floor structures. From the tests, it was found that floor coverings were effective in reducing the floor impact sound using the light impact source. In addition, proper mixtures of the floor structure and the floor covering have shown effectiveness to a certain extent in reducing the floor impact sound using the heavy impact source.

  • PDF

Study on the Linking Method of Information Factors in order to use in wide of Standard Material into Apartment Housing Construction (공동주택의 표준자재 범용화를 위한 정보요소의 연계 및 개발방안 연구)

  • Park, Geun-Soo;Lim, Seok-Ho
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.448-451
    • /
    • 2008
  • This study is under doing to suggest application manual using assembling reference plane design & standard finish material basis upon material classification code as a tool of a linkage between building design and construction standarization in order to enlarge the applicability of house building material that is produced by the module plant. We can say the goal of building standardization intend not only the improvement of construction productibility but also guarantee of subsequent performance through automatization basis upon informationalization of building design. For a etabilishing of this condition, it is neccessary to link the standardization's result of material--design--construction field. According to this neccessity, we are going to suggest information factor that can make relative business manager easily approach to the standardization practical task.

  • PDF

A Study for pathological observations on the exposured mouse to the HCl (HCl에 노출된 mouse의 병리학적 관찰에 관한 연구)

  • Cho, Nam-Wook;Chun, Ji-Hong;Lee, Jong-Cheon;Lee, In-Koo;Shin, Hyun-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.361-364
    • /
    • 2012
  • 최근의 건축물은 다양한 소재의 마감재를 사용함으로서 화재 발생시 다양한 연소가스를 배출한다. 이때 건축물 내부의 화재에 노출된 재실자는 열 및 화상의 위험성과 함께 연기 및 독성가스의 피해를 받기 쉽다. 본 연구에서는 건축물 화재시 발생될 수 있는 HCl에 대한 표준가스를 제작하여 가스유해성시험을 수행하고, HCl 표준가스에 노출된 실험용 쥐의 표적장기적출실험을 수행하였다. 이를 통해서 유독가스에 노출된 실험용 쥐의 해부를 통한 표적장기-심장(Heart), 간(Liver), 폐(Lung), 비장(Spleen), 신장(Kidney), 흉선(Thymus)-의 손상여부와 KS F 2271에 의한 평균행동정지시간과의 관계를 분석하였다.

  • PDF

Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus (EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가)

  • Seo, Jungki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.655-663
    • /
    • 2016
  • Increasing green house gas and it consequent climate change problems are discussed as a global issue. Accordingly, future local green house gas emission will increase up to 40% of the entire local green house gas emission and therefore, efforts to reduce the emission in construction industry is urgently required. Therefore, in this study, heating energy demand was analyzed by using the EnergyPlus simulation according to wood material finishes configuration. EnergyPlus has the entry for a variety of buildings and heating, ventilation, air conditioning (HAVC) system components, in particular buildings, air conditioning systems, and performs simultaneous integrated calculated through the feedback between the heat source unit, a verification program according to the ASHRAE Standard 140-2007 to be. The climate data for the simulation we used the data IWEC in Incheon and Gwangju provided by EnergyPlus. The analysis of simulation model was farm and fishing house standard design drawings: 2012, presented at the Korea Rural Community Corporation. The results of simulation of central region and southern region were effected by wood products of simulation model into the interior finish, exterior finish, windows, wooden structure. Also, it was confirmed that the reduced heating energy demand.

Comparison of Acoustic Performance Depending on the Location of Sound Absorptive and Diffuser in Small Auditoriums Using 1/10 Scale Models (1/10 축소모형을 이용한 소공연장의 흡음재와 확산체의 적용위치에 따른 음향성능 비교)

  • Kim, Tae-Hee;Park, Chan-Jae;Park, Ji-Hoon;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.146-156
    • /
    • 2015
  • This study investigated how the location of sound absorptive materials and sound diffusers affects the acoustic performance of small auditoriums. It was conducted for a standard model established with the averaged dimension of 36 auditoriums which had opened since 2000 in Daehak-ro, Seoul. In this study, the installation area of finishing materials was calculated upon a back wall which had the smallest installation effective area of finishing materials. To analyze the changes of acoustic performance according to installation location of finishing materials, experiments were carried out using the 1/10 down scale models for 8 cases which were made by classifying the installation location of ceiling and side wall into the front, middle and rear part.The used acoustic parameters were reverberation time (RT), early decay time (EDT), clarity (C80), definition (D50) and speech transmission index (STI). In result, the index related to the amount of reverberant sound (RT, EDT) showed the great changes when evaluating it through just noticeable difference (JND), but the one related to clarity (C80, D50, STI) hardly indicated the changes. In case to obtain short reverberation time, it was most effective to control reverberation time through the side walls when installing sound absorptive and diffusive materials, and side wall front was the location which could get the shortest reverberation time.

Development of Vermiculite Board to Secure the Fire Resistance Performance of Light-Frame Wood Structural Wall (경골목구조 벽체의 내화성능확보를 위한 질석보드 개발)

  • Yoo, Seok Hyung;Cheong, Chang Heon
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.40-45
    • /
    • 2018
  • It is considered that vermiculite as an inorganic material is highly effective when it is used as a building finishing material because it is eco-friendly. Vermiculite has excellent properties such as fire resistance, heat insulation, sound absorption as well as prevention of condensation, deodorization and aesthetics. In this study, we developed a finishing board with vermiculite as its main material and mixed with mineral loose wool (VB-L) or mineral powder (VB-P), and conducted fireproof test and insulation test. In addition, fire resistance tests were carried out by applying the two developed vermiculite boards as finishing materials for the standard wall details of light frame wood structures (KS F 1611-1). As a result of the fire resistance test, the VB-L specimen showed better fire resistance than the VB-P specimen. Both vermiculite boards showed sufficient fire resistance performance of 2 hours for a thickness of 30 mm.

A Case Study on the Fire Spread Prevention of Building Exterior (외장재의 화재확산 방지대책을 위한 사례연구)

  • Yoo, Yong-Ho;Kim, Heung-Youl;Kweon, Oh-Sang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.119-122
    • /
    • 2011
  • 도심 건축물의 고층화가 빠르게 진행됨으로 인하여 국내외의 외장재 화재사고가 빈번히 발생하고 있다. 현재 국내 건축법에서는 외벽 마감재에 관한 관련법이 제정되어 있으나, 외장재의 수직 화재 확산에 대한 구체적인 화재안전성능 확보 기준 및 표준 시험 방법 등이 마련되어 있지 않다. 본 연구에서는 해운대 화재사고에 대한 사례 분석을 통하여 국내 제도 개선방향을 검토하고자 하였으며, 새로운 외장재 수직화재확산 성능 평가 기준 및 시헙법 도입을 제안하고자 하였다.

  • PDF

An experimental study on the evaluation of abrasion resistance for concrete surface coating materials by cruising vehicle (차량 주행에 따른 콘크리트용 바닥 마감재의 마모저항성 평가방법)

  • Choi, Eun-Su;Kim, Young-Kun;Seo, Sang-Kyo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.849-852
    • /
    • 2008
  • In the wheel tracking test to evaluate abrasion resistance for concrete surface coating materials applied parking lot, weight of the wheel, test temperature, scattered sand amount, wheel speed, etc. various test condition is used for reliable evaluating the abrasion resistance performance of surface coating materials and the results depends on the test condition. In this paper, we carried experimental study as following on abrasion resistance with 2kinds of different environmental conditions. - Commons : real car tire with 300kg of load, 5km/h of speed, 80,000 cycle. - Control A : no other deterioration condition - Control B : scattering 1.0g of sand per every 30rounds from 1m height.