• Title/Summary/Keyword: 표적융합

Search Result 141, Processing Time 0.024 seconds

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

Dimensionality Reduction Methods Analysis of Hyperspectral Imagery for Unsupervised Change Detection of Multi-sensor Images (이종 영상 간의 무감독 변화탐지를 위한 초분광 영상의 차원 축소 방법 분석)

  • PARK, Hong-Lyun;PARK, Wan-Yong;PARK, Hyun-Chun;CHOI, Seok-Keun;CHOI, Jae-Wan;IM, Hon-Ryang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.1-11
    • /
    • 2019
  • With the development of remote sensing sensor technology, it has become possible to acquire satellite images with various spectral information. In particular, since the hyperspectral image is composed of continuous and narrow spectral wavelength, it can be effectively used in various fields such as land cover classification, target detection, and environment monitoring. Change detection techniques using remote sensing data are generally performed through differences of data with same dimensions. Therefore, it has a disadvantage that it is difficult to apply to heterogeneous sensors having different dimensions. In this study, we have developed a change detection method applicable to hyperspectral image and high spat ial resolution satellite image with different dimensions, and confirmed the applicability of the change detection method between heterogeneous images. For the application of the change detection method, the dimension of hyperspectral image was reduced by using correlation analysis and principal component analysis, and the change detection algorithm used CVA. The ROC curve and the AUC were calculated using the reference data for the evaluation of change detection performance. Experimental results show that the change detection performance is higher when using the image generated by adequate dimensionality reduction than the case using the original hyperspectral image.

Study precision attitude control of marine biological robot which utilizes a plurality of sensors (다중 센서를 이용한 해양 생체 로봇의 정밀 자세 제어 연구)

  • Kim, Min;Son, Kyung-Min;Park, Won-hyun;Kim, Gwan-Hyung;Byun, Ki-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.548-549
    • /
    • 2015
  • 무인 잠수정은 자율 무인잠수정(이하 'AUV' 또는 '자율무인잠수정'을 혼용)과 원격조정잠수정(이하 'ROV'로 지칭)으로 분류를 할 수 있다. ROV는 테더 게이블로 인한 작업 범위의 한계와 운동성능 효율이 떨어지는 단점을 지니고 있어, 테더 케이블이 필요 없는 AUV에 대한 필요성이 증대되고 있다. 추측 항법 시스템인 관성 항법 시스템(inertial navigation system, 이하 'INS'로 지칭)은 외부 도움없이 관성측정 장치(inertial measurement unit, 이하 'IMU'로 지칭)를 활용하여 구성된 시스템을 말한다. IMU는 자이로 스코프(gyroscope), 가속도계(accelerometer), 지자기(magnetic)센서로 구성된 측정 장치로 3개의 센서를 사용하여 상호 보정을 통한 기동 체의 위치, 속도 및 자세 정보를 제공한다. 복합항법시스템은 추측항법시스템이 가지는 누적오차와 측위 항법시스템이 가지는 외부환경에 대한 단점을 상호 보완하는 방법으로 연구가 진행 중이다. 하지만 심해서 또는 해양의 특성에 따라 측위 시스템이 사용되지 못하기 때문에 추측 항법시스템의 다양한 관성 센서를 활용한 상로 보완과 신호처리 방법을 통한 연구 개발이 진행 중이다. 다양한 센서 정보를 통합하는 목적으로 칼만 필터와 같은 최적 필터기법이 보편적으로 사용되고 있다. 칼만 필터는 확률 선형 시스템에 대하여 공정잡음 및 측정 잡음이 가우시안 확률 분포를 따를 때 최적의 추정자가 된다. 또한 가우시안 조건을 만족하지 않는 경우에도 선형 추정자 중에 추정 오차의 분산이 가장 작은 추정자이다. 칼만 필터가 최상의 성능을 발휘 하려면 공정잡음과 측정 잡음의 실제 값을 정확히 알아내는 것이 중요하다. 잡음 수준에 대한 정보가 부정확 할 경우 칼만 필터는 발산 할 수 있기 때문에 시스템에서 잡음 수준의 공산은 칼만 필터의 최적 이득을 결정하는 중요한 요소로 추정치에 큰 영향을 준다. 따라서 칼만 필터를 추측항법시스템에 적용 시킬 경우 실제 모텔의 잡음 공분산을 정확히 추정할 수 있는 기법이 요구된다. 추측항법시스템은 다양한 센서를 활용하기 때문에 움직이는 기동 표적에 적용시 잡음공분상이 변하기 때문에 항법시스템이 저하 될 수 있다. 본 연구에서는 다양한 센서를 융합하여 해양 생체 로봇의 정밀 자세 제어가 가능한 시스템을 제안하고자 한다.

  • PDF

A Study on the Reestablishment of the Drone's Concept (드론 개념의 재정립에 관한 연구)

  • Lee, Seungyoung;Kang, Wook
    • Korean Security Journal
    • /
    • no.58
    • /
    • pp.35-58
    • /
    • 2019
  • Drone was originally developed for air force aircraft or missile exercise shooting targets, and is being considered as the entire unmanned aircraft to the public. The core concept of a drone can be divided into 'unmanned' and 'aircraft'. However, there are many questions about whether the Fourth Industrial Revolution, expressed as a convergence scientific innovation, is appropriate at a time when smart cities are proposed as a concept of new urban spatial formation, and the role of self-driving vehicles, including drones, is being emphasized within the new urban integrated transport system. In this study, the concept of the existing drones was analyzed for the development process, definitions in each country's laws, and the results of the preceding research to present a concept suitable for future society and a unified term. It is not desirable to define a drone for the purpose of a country, an institution, or an operating entity, depending on the circumstances of the era. It is more reasonable to find the concept of a drone based on human life than in the traditional way, and more reasonable considering the development of the drones in the future. Subsequent studies should be more detailed, more data and research results analyzed, and discussed areas that were not covered in this study. Based on this, research should also be conducted on a variety of topics, including legislation, preparation of operational regulations, and related industrial processes and regulations.

A Comparative Study on the Head and Neck Radiation Therapy for Dynamic Conformal Arc Therapy and Volumetric Modulated Arc Therapy (두경부 방사선 치료 시 입체조형동적회전조사치료와 용적변조회전조사치료에 관한 연구)

  • Kim, Deok-Ki;Choi, CheonWoong;Choi, Jae-hyock;Won, Hui-su;Park, Cheol-soo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.208-218
    • /
    • 2015
  • Recently, radiation therapy is used in the CT existing conventional two-dimensional radiation image, and set the size and location of the tumor in a manner that the image is going to change the treatment plan. After using the simulation using CT, radiation therapy it is four-dimensional or three-dimensional treatment made possible. and radiation therapy became the more effective ever before. High technology radiation therapy such as the treatment of SRS,IMRT, IGRT, SBRT, is a need to try contemplating the possibility to apply appropriate analysis and situation, so it has its own characteristics. and then it is believed that it is necessary to analyze and try it worries the proper applicability of the situation. The configuration of the various treatment that is applicable in many hospitals is necessary to try to determine how to practically apply the patients. Critical organs surrounding tumor give a small dose to avoid side effects and then the tumor has the therapeutic effect by providing a larger dose than before the radiation treatment.

A Study on the Honesty Ethical Consciousness of Koreans and the Mission of Korean Churches (한국인의 정직윤리의식과 한국교회의 역할에 대한 연구)

  • Ahn, Jong Bae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.67-78
    • /
    • 2020
  • Honesty is an attribute of God, and the Bible says that God is pleased, praises, and blesses honest people. However, false and hypocrisy is overflowing and honesty is being weakened in Korean society and the church. In this regard, we need to understand the level of honesty and ethical consciousness of youth and adults (workers) in Korea, and how to spread honesty in Korean society in order for the Korean church to restore its essence and play the role of light and salt in the world. To this end, We analyzed the honest ethical consciousness of Korean youth and adults (workers) by using the results of the Korean Honest Index survey conducted by the researchers at the Ethics Center of the Transparent Society Movement Headquarters of the Heungsadan in 2019. In addition, through Focus Group Interview (FGI) of 12 pastors who are practicing the honesty movement in the Korean church, we analyzed pastors' opinions on what the Korean church should do and what role it should play in order to raise the honesty ethical consciousness of Korean society. We hope that it will be an opportunity to recognize the seriousness of the honest and ethical consciousness of Korean society, and to take an active role in helping the Korean church return to the spirit of Koramdeo and spread the honest kingdom and righteousness of God in Korean society through this study.

Application of Primary Rat Corneal Epithelial Cells to Evaluate Toxicity of Particulate Matter 2.5 to the Eyes (눈에 대한 미세먼지의 독성 평가를 위한 쥐 각막 상피 세포의 적용)

  • Kim, Da Hye;Hwangbo, Hyun;Lee, Hyesook;Cheong, Jaehun;Choi, Yung Hyun
    • Journal of Life Science
    • /
    • v.32 no.9
    • /
    • pp.712-720
    • /
    • 2022
  • The purpose of this study was to investigate the efficacy of rat corneal-derived epithelial cells as an in vitro model to evaluate the harmfulness of the cornea caused by particulate matter 2.5 (PM2.5). To establish an experimental model for the effect of PM2.5 on corneal epithelial cells, it was confirmed that primary cultured cells isolated from rat eyes were corneal epithelial cells through pan-cytokeratin staining. Our results showed that PM2.5 treatment reduced cell viability of primary rat corneal epithelial (RCE) cells, which was associated with the induction of apoptosis. PM2.5 treatment also increased the generation of reactive oxygen species due to mitochondrial dysfunction. In addition, the production of nitric oxide and inflammatory cytokines was increased in PM2.5-treated RCE cells. Furthermore, through heatmap analysis showing various expression profiling between PM2.5-exposed and unexposed RCE cells, we proposed five genes, including BLNK, IL-1RA, Itga2b, ABCb1a and Ptgs2, as potential targets for clinical treatment of PM-related ocular diseases. These findings indicate that the primary RCE cell line is a useful in vitro model system for the study of PM2.5-mediated pathological mechanisms and that PM2.5-induced oxidative and inflammatory responses are key factors in PM2.5-induced ocular surface disorders.

A Study on the Work Adaptation of Re-Employed Industrial Accident Workers (재취업 산재근로자의 직장 적응 결정요인 분석)

  • Kye-Won Choi;Young-Min Lee
    • Journal of Industrial Convergence
    • /
    • v.22 no.3
    • /
    • pp.1-12
    • /
    • 2024
  • The purpose of this study is to categorize the adaptation of re-employed injured workers to the workplace and to explore the determinants that affect their adaptation to the workplace. In order to categorize the group of re-employed injured workers to adapt to the workplace, a latent profile analysis was conducted on 522 injured workers. As a result of the analysis, the workplace adaptation group was classified into three types: environmental dominant adaptation type (group 1), work-oriented adaptation type (group 2), and 'environmental adaptation type (group 3). In addition, as a result of conducting a mixed regression analysis to analyze the factors influencing their adaptation to the workplace after industrial accident, it was found that the work-oriented adaptation and environmental adaptation adaptation type were lower than the environmental dominant adaptation type. In addition, it was confirmed that educational background and self-esteem are factors that have an important influence on the adaptation of injured workers to the workplace. Based on the results of this study, it was suggested that the system needs to be supplemented in two aspects: customized support for individuals in the pre-reemployment stage and the employment environment after re-employment in order to increase the adaptation of injured workers to work. Specifically, there are consideration of the development and spread of rehabilitation programs and the expansion of the scope of subsidies that were paid only to the original business owners. Through this study, it is expected that more targeted policy measures can be prepared for re-employed injured workers.

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

THE EXPRESSION OF MSX GENES DURING EARLY CRANIAL SUTURE EMBRYOGENESIS (두개골 봉합부의 초기 형태발생과정에서 Msx 유전자들의 발현양상)

  • Lee, Sang-Youp;Park, Mi-Hyun;Ryoo, Hyun-Mo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.171-180
    • /
    • 2003
  • The development of calvarial bones is tighly co-ordinated with the growth of the brain and needs of harmonious interactions between different tissues within the calvarial sutures. Premature fusion of cranial sutures, known as craniosynostosis, presumably involves disturbance of these interactions. Mutations in the homeobox-containg gene Msx2 cause human craniosynostosis syndrome. Msx genes, which are consist of Msx1, Msx2 and Msx3, are homeobox-containg transcripton factors, and were originally identified as homologue of Drosophila msh(muscle segment homeobox) gene. Msx1 and Msx2 genes, expressed mostly in overlapping patterns at multiple site of tissue interactions during vertebrate development, are associated with epithelial-mesenchymal interactions during organogenesis, targets of BMP and FGF signaling. To elucidate the function of Msx genes in the early morphogenesis of mouse cranial suture, we analyzed the expression of them by in situ hybridization during embryonic(E15-E18) stage, and did vivo experiments in E15.5 mouse using rhBMP-2, rhFGF-2 protein soaked bead. In the sagittal suture, Msx1 was expressed in the mesenchyme of suture and the dura mater, Msx2 was intensely expressed in the sutural mesenchyme and the dura mater. In the coronal suture both of Msx genes were expressed intensely in the sutural mesenchyme and expressed in the periosteum also. Msx1 had a broader expression pattern than Msx2. BMP2 beads induced expression of both Msx1 and Msx2, FGF2 beads induced expression of Msx1, but not Msx2. Taken together, these data suggest that Msx1 and Msx2 genes have important role in regulating the morphogenesis and maintenance of embryonic cranial suture. Both of Msx genes are expressed similarly but because of their upstream signaling, they function dependently or cooperatively according to change of signaling molecule.

  • PDF