• Title/Summary/Keyword: 표면초음파

Search Result 534, Processing Time 0.031 seconds

Fabrication of PVDF Line Focus Ultrasonic Transducer and its Application II. Applicatin to LSAW Measurement (직선집속 PVDF 초음파트랜스듀서의 제작과 응용 II. 누설탄성표면파 측정에의 응용)

  • Yoon Hyuck-joon;Ha Kang-lyeol;Kim Moo-joon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.391-394
    • /
    • 1999
  • 제작되어진 LFB PVDF 초음파트랜스듀서를 이용하여 누설탄성표면파(Leaky Surface Acoustic Wave : LSAW)측정을 하였다. 시료로서는 $SiO_2$, Al, Cu등을 사용하였고, 측정방법으로써는 초점면에 위치한 시료를 트랜스듀서 쪽으로 접근시켰을 때 LSAW가 트랜스듀서의 중심축을 통과한 후 시료표면에서 반사되어오는 종파와 분리되어지는 현상을 이용하였다. 실험결과는 Campbell and Jones의 이론에 의한 해석결과와 비교 분석하였는데 매우 잘 일치됨을 알 수 있었다.

  • PDF

Position Control Technique of Ultrasonic Scanner for an Automated Ultrasonic Testing Using Surface Wave (표면파를 이용한 자동 초음파탐상검사 주사장치의 위치제어 기술)

  • Lee, Jong-Po;Park, Chul-Hoon;Um, Byong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.30-37
    • /
    • 2003
  • In order to replace the manual ultrasonic testing(UT) with an automated UT(AUT), a scanner which enables us to control the positions of a transducer is essential. Encoders have been commonly used to obtain the position information from the conventional scanners controlled by motor. Encoders have various advantages in many aspects. However, if the slip of motor wheel occurs during scanning, various errors are involved in the position accuracy. Thus, the position information of encoders becomes meaningless in case of slip. The reliability of AUT results nay become serious problem. Hence, slip must be avoided, but it can not be completely avoided at present time. In this paper, a new idea that surface wave is used to solve this problem and replace encoders has been proposed. It is shown that this idea can be employed in AUT scanner without encoders. That is, one transducer transmitting surface wave is fixed and the other transducer attached to the scanner receives UT signal. Then, computer calculates the present position of scanner based on the information given by surface wave. Thus, the movement of a scanner can be controlled by the amount of input based on the information obtained.

Development of Automatic System to Measure Transmitted Ultrasonic Speed of Raw Ginseng (수삼의 초음파 전달속도 계측 자동화 시스템 개발)

  • 서동현;김기대;강호양;김찬수;이현동
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.592-599
    • /
    • 2002
  • 본 연구에서는 수삼의 가공전 선별을 위해 현장에서 편리하게 사용할 수 있는 초음파 전달 속도 계측 자동화 시스템을 개발하여 그 성능을 평가하고자 하였으며 결과를 요약하면 다음과 같다. 1. 개발된 시스템은 제어용 컴퓨터, 시스템 구동 및 탐촉자 이동 장치, 하중 변환장치, 초음파 발생 및 송수신 장치 등으로 구성되었다. 2. 제어 및 계측용 프로그램은 압축력, 측정 대상물의 크기, 초음파 전달 시간을 순차적으로 계측하여 초음파 전달 속도를 계산하는 알고리즘을 개발하였으며, Visual Basic 6.0으로 작성되었다. 모터의 작동, A/D 변환, RS232C 통신 등과 관련된 부분은 각각의 모듈화된 함수로서 구동하고자 하였다. 3. 개발된 시스템의 속도와 거리별 이동 거리별 오차를 측정한 결과 0∼0.04mm 범위를 나타내었다. 이 값은 시스템의 허용오차인 0.17mm 오차보다는 현저히 작은 값이었고 15mm/s와 30mm/s의 이동 속도에서 모두 비슷한 크기의 오차값을 나타내었다. 4. 개발된 시스템의 속도별 반복정밀도 실험 결과 측정위치에서의 반복에 의한 정지 위치 오차는 전 구간에서 0.02mm 이내로 나타났고, 이동 평판의 이동속도가 15mm/s였을 경우에는 이동 회수 30회, 이동 거리 60mm일 때 최대 편차 0.019mm를 나타냈으며 이동속도가 30mm/s일 경우에는 이동 회수 40회, 이동거리 20mm에서 0.02mm의 최대 편차를 나타내었다. 5. 5개의 알루미늄 조각의 크기를 시스템으로 측정한 결과 측정값의 최대 편차는 0.08mm였다. 이 값은 시스템의 허용오차인 0.17mm의 50% 수준으로 시스템은 대상물의 크기 측정에 적당하다고 사료되었다. 6. 절단된 수삼의 초음파 전달속도는 평균 396.4m/s였다.를 축열재로 사용할 경우 재생기를 반으로 나누어서 가열부 쪽에 철선을, 냉각부 쪽에 철망을 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차는 높게 나타났고, 재생기 양단의 압력 차는 낮게 나타났다. 재생기 축열재로서 철망-철선을 사용할 경우 철선-철망 ø1.2-150이 전열 표면적은 작으나 재생기 양단의 온도차가 가장 큰 것으로 나타났으며 재생기 양단의 압력 차는 가장 낮게 나타나 공시 철망- 철선 혼합 축열재중 가장 우수함을 알 수 있다. 4. 철망사이에 철선을 삽입한 축열재의 경우, 철망사이에 삽입한 철선의 직경이 큰 것이 철선의 직경이 작은 것보다 재생기의 양단의 온도차가 높게 나타났고 재생기 양단의 압력차는 작게 나타났다. 그러므로 철망사이에 철선을 삽입한 것 중 성능이 우수한 것은 150-ø2. 0-150으로 나타났다. 5. 실험한 재생기 축열재들 중에서 성능이 우수한 것들을 비교한 결과, 복합 철선 ø1.2-1 50이 가장 성능이 좋은 것으로 나타났다.적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수

  • PDF

Ultrasonic Backscattering on Painted Rough Surface at near Rayleigh Angle (레일리각 근처에서 도색된 거친 표면으로부터 후방 산란된 초음파)

  • Kwon, Sung-D.;Kwon, Yong-G.;Yoon, Seok-S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • The angular dependence (or profile) of backscattered ultrasound was measured for steel specimens with a range of surface roughness, $1{\sim}71{\mu}m$. Backscattering profiles at or near the Rayleigh angle still showed roughness dependence while the assessment of surface roughness via normal profile became impossible due to the paint layer masking the roughness. The peak amplitude directly radiated at the Rayleigh angle was proportional to the surface roughness, while the averaged peak amplitude radiated from the backward propagating Rayleigh wave, produced by reflection at a corner, was inversely proportional. In the painted specimens, the linearity of direct backward radiation with the roughness was observed even at the roughness of less than three hundredths of a wavelength, and the abnormal multiple bark reflection caused by periodic roughness disappeared.

Optimization of Electro-UV-Ultrasonic Complex Process for E. coli Disinfection using Box-Behnken Experiment (Box-Behnken법을 이용한 E. coli 소독에서 전기-UV-초음파 복합 공정의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.149-156
    • /
    • 2011
  • This experimental design and response surface methodology (RSM) have been applied to the investigation of the electro-UV-ultrasonic complex process for the disinfection of E. coli in the water. The disinfection reactions of electro-UV-ultrasonic process were mathematically described as a function of parameters power of electrolysis ($X_1$), UV ($X_2$), and ultrasonic process ($X_3$) being modeled by use of the Box-Behnken technique, which was used for fitting 2nd order response surface model. The application of RSM yielded the following regression equation, which is empirical relationship between the residual E. coli number (Ln CFU) in water and test variables in coded unit: residual E. coli number (Ln CFU) = 23.69 - 3.75 Electrolysis - 0.67 UV - 0.26 Ultrasonic - 0.16 Electrolysis UV + 0.05 Electrolysis Ultrasonic + 0.27 $Electrolysis^2$ + 0.14 $UV^2$ - 0.01 $Ultrasonic^2$). The model predictions agreed well with the experimentally observed result ($R^2$ = 0.983). Graphical 2D contour and 3D response surface plots were used to locate the optimum range. The estimated ridge of maximum response and optimal conditions for residual E. coli number (Ln CFU) using 'numerical optimization' of Design-Expert software were 1.47 Ln CFU/L and 6.94 W of electrolysis, 6.72 W of UV and 14.23 W of ultrasonic process. This study clearly showed that response surface methodology was one of the suitable methods to optimize the operating conditions and minimize the residual E. coli number of the complex disinfection.

Evaluation of Adhesive Strength for Nano-Structured Thin Film by Scanning Acoustic Microscope (초음파 현미경을 이용한 나노 박막의 접합 강도 평가)

  • Park, Tae-Sung;Kwak, Dong-Ryul;Park, Ik-Keun;Miyasaka, Chiaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.393-400
    • /
    • 2012
  • In recent years, nano-structured thin film systems are often applied in industries such as MEMS/NEMS device, optical coating, semiconductor or like this. Thin films are used for many and varied purpose to provide resistance to abrasion, erosion, corrosion, or high temperature oxidation and also to provide special magnetic or dielectric properties. Quite a number of articles to evaluate the characterization of thin film structure such as film density, film grain size, film elastic properties, and film/substrate interface condition were reported. Among them, the evaluation of film adhesive to substrate has been of great interest. In this study, we fabricated the polymeric thin film system with different adhesive conditions to evaluate the adhesive condition of the thin film. The nano-structured thin film system was fabricated by spin coating method. And then V(z) curve technique was applied to evaluate adhesive condition of the interface by measuring the surface acoustic wave(SAW) velocity by scanning acoustic microscope(SAM). Furthermore, a nano-scratch technique was applied to the systems to obtain correlations between the velocity of the SAW propagating within the system including the interface and the shear adhesive force. The results show a good correlation between the SAW velocities measured by acoustic spectroscope and the critical load measured by the nano-scratch test. Consequently, V(z) curve method showed potentials for characterizing the adhesive conditions at the interface by acoustic microscope.

Review of Micro/Nano Nondestructive Evaluation Technique (II): Measurement of Acoustic Properties (마이크로/나노 비파괴평가 기술(II): 음향특성계측)

  • Kim, Chung-Seok;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.418-430
    • /
    • 2012
  • The present paper reviews the micro and nano nondestructive evaluation(NDE) technique that is possible to investigate the surface and measure the acoustic properties. The technical theory, features and applications of the ultrasonic atomic force microscopy(UAFM) and scanning acoustic microscopy(SAM) are illustrated. Especially, these technologies are possible to evaluate the mechanical properties in micro/nano structure and surface through the measurement of acoustic properties in addition to the observation of surface and subsurface. Consequently, it is thought that technique developments and applications of these micro/nano NDE in advanced industrial parts together with present nondestructive industry are widely possible hereafter.

Propagation Characteristics of Ultrasonic Wave of Surface Hardened SCM440 and SCM415 Steels (SCM440, SCM415강의 표면강화에 따른 초음파의 전파특성)

  • Park, Eun-Su;Gang, Gye-Myeong;Kim, Seon-Jin;Jang, Sun-Sik
    • Korean Journal of Materials Research
    • /
    • v.3 no.5
    • /
    • pp.538-545
    • /
    • 1993
  • By using propagation characteristics of ultrasonic surface wave, the depth of the surface hardened layer of SCM440 steel with different high frequency induction heat treatments was measured and the same was done on the carburized SCM415 steel. The propagation velocity of surface wave was constant and independent of frequency in t.he specimens with identical microstructure, it was, however, decreased by 59m/s in the hardened layers compared to the unhardened part. From t.he relationship between the effective case depth and the wave length of surface wave, the depth of the hardened layer could be measured and evaluated nondestructively for both induction hardened and carburized steels.

  • PDF

Application of Laser-based Ultrasonic Technique for Evaluation of Corrosion and Defects in Pipeline (배관부 부식 및 결함 평가를 위한 레이저 유도 초음파 적용 기술)

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.95-102
    • /
    • 2005
  • There are many tube and pipeline in nuclear power plant under high temperature and high pressure. Erosion and corrosion defects were expected on these tube and pipe-line by environmental and mechanical factors. These erosion and corrosion defects ran be evaluated by ultrasonic technique. In these study, Scanning Laser Source(SLS) technique was applied to detect defect and construct image. This technique also makes detection possible on rough and curved surfaces such as tube and pipe-line by scanning. Conventional ultrasonic scanning technique requires immersion of specimen or water jet for transferring ultrasonic wave between transducer and specimen. However, this SLS technique does not need contacting and couplant to generate surface wave and to get flaw images. Therefore, this SLS technique has several advantages, for complicated production inspection, non-contact, remote from specimen, and high resolution. In this study, SLS images were obtained with various conditions of generation laser ultrasound and receiving in order to enhance detectability of flaws on the tube. Stress corrosion cracks were produced on tube and images of stress corrosion cracks were constructed by using SLS technique.

Usefulness of Twinkling Artifacts in Color Doppler Ultrasonography (컬러 도플러 초음파에서 Twinkling artifacts의 유용성)

  • Sim, Hyun-Sun;Kwon, Kyung-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.291-298
    • /
    • 2016
  • The aim of the study was to investigate the diagnostic value of the color Doppler twinkling artifact in disease of urinary system. The intensity of twinkling artifact(TA) with color Doppler was classified into 3 levels, 0(non-TA) to 3(distinct TA). In the in vitro study, acorn jelly with various materials on top was examined using color Doppler at B-mode sonography in a water bath for TA. 31 patients with diagnosis of urinary calculi(renal stones 16, urinary stones 15) based on B-mode sonography were studied in vivo for TA. The materials with rough surfaces such as salt, screw and cubics at B-mode sonography with color Doppler contributed to causing TA. At B-mode sonography without color Doppler 37% of renal stones and 60% of ureter stones were detected. but at B-mode sonography with color Doppler TA was demonstrated for all cases. Superficial roughness of materials affected occurrence of TA at B-mode sonography with color Doppler. Therefore, TA at B-mode sonography without color Doppler could play a role in confident diagnosis of the disease of urinary system.