• Title/Summary/Keyword: 표면오염도

Search Result 104, Processing Time 0.031 seconds

Analysis of Hydrophobic Membrane Fouling on the COD Loading Rates at the State of Passive Adsorption in Membrane Bioreactor (생물학적 막분리 공정에서 수동흡착 상태에서의 유기물 유입 부하에 따른 소수성 막의 오염도 분석)

  • Park, Tae-Young;Choi, Changkyoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.152-158
    • /
    • 2015
  • This paper investigated the membrane fouling potential at the state of passive adsorption which is no permeation with the test modules on COD (Chemical oxygen demand) loading rates, examined the recovery rate and resistance on membrane fouling by three cleaning manners of hydrophobic membrane in a bioreactor. The results showed that high COD loading led to the increase of extra-cellular polymeric substances and filtration resistance. The permeability resistance from 1st day to 63rd day was getting increased, however, the value of permeability resistance after 63th day during the operation period was almost same level at three COD loading rates, it was due that the biomass adhesion on membrane surface at the state of passive adsorption reached to the critical state. Also, the final recovery rates after three cleaning manners were 78%, 72% and 69% at the COD loading concentrations of 250 mg/L, 500 mg/L and 750 mg/L respectively, and then recovery rate by physical cleaning at Run 2 and Run 3 was decreased after 40th day, it proved that biomass cake, which is not easily removed, was formed on the membrane surface because of high COD loading rate and EPS concentration.

A study on the Manufacture and Application of UV-Cured Anti-stain Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 내오염 코팅액의 제조 및 응용에 관한 연구)

  • Yoon, Hyun-Jung;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1741-1746
    • /
    • 2010
  • This study is on development of UV-cured anti-stain coating compounds which have more improved anti-stain function to prevent a surface of PVC tile from stain. To make an anti-stain coating composition, water soluble antistatic agent made from ammonium(IV) salt, antistatic agents for acrylic and polyurethane were used. Their contents varied from 5 to 20wt% against quantities of resin in coating composition. After coating PVC tiles using bar-coating method that can adjust a thickness, we estimated surface properties of coated layer such as anti-stain, electric resistance, adhesive power, thickness of coating, and so on. Results showed that a coating composition added 15wt% of water soluble antistatic agent and coated with No.12 bar-coater had the optimum surface property in electric resistance($3.24{\times}10^9{\Omega}/cm^2$), anti-stain(ink Test, Dust Test) and adhesive power. We could also find electric resistance and anti-stain effect were improved as antistatic agent content increased. However, excessive addition of antistatic agents(over 20wt%) caused the migration.

Deterioration Diagnosis and Petrogenesis for Rock Properties of the Stone Lantern in the Gwanchoksa Temple, Nonsan, Korea (논산 관촉사 석등의 훼손도 진단 및 기원암의 성인적 해석)

  • Lee, Myeong Seong;Yi, Jeong Eun;Pyo, Su Hee;Song, Chi Young;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.17 s.17
    • /
    • pp.5-18
    • /
    • 2005
  • Rock materials of the Stone Lantern in the Gwanchoksa temple was composed of dark grey granodiorite. This Stone Lantern is partly structural distortion as S-shape, especially, rocks of the upper supports and under the roof materials were highly deterioration due to the surface exfoliation, and strong secondary contaminations owing to the discoloration by oxidation of inserted iron plates between the rock properties, and white grey to dark black contaminants along the rain path way. Rock surface of the Stone Lantern occurred as partly green patches because of coated by algae, lichen and moss. This biological problems are need for cleaning and treatments. The Stone Lantern have to be considered to conservation method that can reduce weathering factors with long-term monitoring about environmental change for structural stability, surface degradation and mechanical weathering. Materials of the Stone Lantern and basement rocks of the area are consisted of same petrogenetic granodiotite based on occurrences, petrological and geochemical characteristics.

  • PDF

Consideration of Radioactive Contamination Materials Disposal (방사성오염물질 처분에 대한 고찰)

  • Im, Hyun-Jin;Kim, Tae-Yeob;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.128-132
    • /
    • 2010
  • Purpose: Nuclear medicine general operation room is radioactive control room which is used for the handling of radioisotope(R.I). Radioactive contamination materials must be under control and separated from general trash. With this experiments, we want to actively suggest the guideline of controling and operating radioactive contamination materials by measuring contamination degree and analyzing the causes which is not realized so far. Materials and Methods: Materials are selected from Oct. 2009 to March. 2010. salines which are used for labelling radiophamaceuticals and generator cap, saline needle cap, $^{99m}Tc$-needle cap saline vial which is generated from $^{99}Mo$/$^{99m}Tc$ generator. After measuring each surface contamination degree by survey meter, mean value and standard deviation one were solved out. Results: In result, After measuring surface contamination degree, radioactivity of saline for labelling radiophamaceuticals showed $14429{\pm}26378$ cpm (p<0.05) and in measured generators, foreign imported things showed that generator cap : $9{\pm}21$ cpm, saline vial : $17{\pm}28$ cpm. saline needle cap : $35{\pm}66$ cpm, $^{99m}Tc$-needle cap : $9{\pm}21$ cpm, saline vial $13{\pm}28$ cpm. domestic things showed that generator cap : $22852{\pm}52545$ cpm, saline needle cap : $87367{\pm}109711$ cpm, $^{99m}Tc$-needle cap : $9008{\pm}10459$ cpm, saline vial : $186416{\pm}158196$ cpm (p<0.05). Conclusion: The saline which is used for labelling, exceeded 1/10 of maximum permissible range. this is generated from radiophamaceuticals dilution procedure. and In generators, radioactive value of foreign import things showed closely background value. but which of domestic thing showed that exceeded more than 1000 values 1/10 of maximum permissible range. the causes of that is domestic generator is contaminated in manufacturing procedure. So, to dispose radioactive contamination materials which is could betaken out of, the control and operation must be radical under controlled by radioactive measuring, recording and equipping of its own. if this is kept well, we can prevent surely that radioactive waste could be disposed like as general trash.

  • PDF

A Study on the Effect of Water Quality Improvement of a Storm Sewage by Detention Pond (저류지에 의한 우수의 수질개선 효과 연구)

  • Lee, Jong-Tae;Song, Chi-Heung;Gang, Tae-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.3
    • /
    • pp.351-364
    • /
    • 2000
  • The effect of water quality improvement of combined sewage by detention pond has been studied. It is convinced that the pollutant load and peak flow through the combined sewer by first rainfall and runoff can be decreased by detention pond sited at the outlet of small basin. Hydraulic modeling of detention panel was performed for two cases of sedimentation pond and gravel contact pond. It has been recognized that it is more efficient to reduce the pollutant of combined sewage when the combined sewage is released alter a fixed detention time in the detention pond than it is released continuously without detention time. The gravel contact detention pond shows higher pollutant removal rate than the sedimentation detention pond in all pollutants. When it comes to gravel contact detention pond, the gravel pond filled with crushed gravel has a higher pollutant removal rate than that filled with river gravel.

  • PDF

Microbiological quality on surfaces of beef and pork carcasses in Seoul (소와 돼지 도체 표면에 대한 미생물 오염도)

  • 김은;나인택;기노준;이정학
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • It was conducted to evaluate the microbiological quality on the surface of slaughtered beef and pork products in Seoul from January 2003 to December 2003. Two hundreds four beefs and 284 pork carcasses were surveyed on generic E coli, total bacterial count for microbiological quality, and Salmonella spp as food-borne pathogen. The prevalence of the excellent or good grade(10$^4$ CFU/$\textrm{cm}^2$ in SPC) of beef and pork carcasses were 99.7% and 97.9%, respectively. The frequency of beef carcasses with less than 10$^2$ CFU/$\textrm{cm}^2$ of E coli was 100%, while that of pork carcasses was 98.2%. Salmonella spp was not recovered from all of beef and pork carcasses.

Study on the non-point source control and treatment with soil surface form (토지의 표면층변화에 따른 비점오염원 관리 및 처리 연구)

  • Kim, Sung-Won;Kim, Seog-Ku;Lee, Young-Ah;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.972-976
    • /
    • 2006
  • 비점오염은 일정한 오염원 없이 광범위한 지역에 쌓여 있는 오염물질이 강우 등에 의해 산발적으로 유출되는 비정형적인 오염을 말한다. 비점오염물질의 유출은 강우나 해빙에 의해 일시에 다량 발생되어 수계로 빠른 시간 내에 도달되게 되므로 인근 수계환경의 수질에 악영향을 미치게 되며, 이러한 오염물질을 효율적으로 처리하기 위해서는 발생원 가까이에서 수계에 도달하기 전에 저감하거나 유출과정에서 집수 처리하는 것이 가장 바람직하다. 본 연구에서는 이러한 비점오염물질의 저감을 위해 반응조를 이용한 실내실험을 실시하였다. 실내 실험장치는 아크릴로 제작 되었으며, 제원은 $1,000mm(L){\times}150mm(W){\times}300mm(H)$였다. 유입수는 시약을 이용하여 질소와 인의 농도를 고농도와 저농도로 조제하여 사용하였고, 유입은 미량 유량펌프를 이용하여 유입하였다. 토양의 오염물질의 처리 효율이 표면유출보다 하부유출에서 더 좋은 것으로 나타났기 때문에 하부유출의 양을 늘이기 위해 인위적으로 물의 흐름을 막는 정류벽을 설치한 계단형으로 구성하여 직선형과 비교하였다. 연구 결과, 단기간 저농도의 경우T-N, T-P부분에서 보면 직선형과 계단형의 표면유출 에서의 저감 효율이 T-N은 각각 -2.6 %, 2.4 %, T-P는 각각 -11.0 %, 52.9 %로 표면유출수의 오염저감효과가 개선되는 것으로 나타났다. 이는 방류벽 앞에 하부로 침투되었던 물이 표면으로 유출되면서 오염물질의 저감이 일어났기 때문으로 판단된다. 반면, 단면 및 하부유출수의 오염물질 농도는 증가한 것으로 나타났는데, 이는 토양내의 입경이 작은 silt나 clay보다 입경이 큰 모래나 자갈을 경유 하면서 오염물의 저감효과가 감소한 것으로 판단된다. 그러나 유입유량의 대부분이 표면으로 유출된다는 점을 고려할 때 표면유출수의 오염도를 낮추는 것이 유입오염물 저감효과에 보다 큰 효과가 있을 것으로 판단된다.문에 자료의 이상적 유지 관리가 이루어지며 복잡한 2차원 수질해석 모형을 수월하게 운영할 수 있는 시스템으로 개발하였다.제외하면, 부자측정 방법에 의한 유량산정시 가장 큰 오차원인은 홍수시 측정된 유속측선의 위치와 홍수 전후로 측정된 횡단면상의 위치가 일치하지 않는 점과, 대부분 두 측정 구간의 평균값을 대푯값으로 사용한다는 점이다. 본 연구는 다년간의 유량 측정 및 검증 경험과 자료를 토대로 현장에서 부자를 이용하여 측정된 측정성과를 정확도 높은 유량자료로 산정하는데 있어서의 문제점을 도출하고, 이로 인해 발생하는 오차를 추정하여 그 개선방안을 제시해 보고자한다. 더불어 보다 정확한 유량 산정을 위한 기준과 범주를 제시하고자 한다.리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전략이고, 이 전략의 유용성은 투자자가 설정한 투자기간보다 더욱 긴 분석기간의 주식가격정보에 의하여 최대한 발휘될 수 있음을 확인하

  • PDF

Analysis of Pathogenic Microorganism's Contamination on Organic Leafy Vegetables at Greenhouse in Korea (유기농 시설엽채류의 유해미생물 오염평가)

  • Oh, Soh-Young;Nam, Ki-Woong;Yoon, Deok-Hoon
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • This study was conducted to evaluate the microbiological safety of leafy vegetables (perilla leaf and lettuce) in relation to cultivation methods. A total of 2,304 samples were collected from plants, harvesting tools and soil mulching film during the production and harvest stages from organic- and conventional- farms. From the samples, sanitary indicator microorganisms (total aerobic bacteria, coliforms, E. coli., Environmental Listeria, and yeast and mold) and pathogenic microorganisms (S. aureus, B. cereus, Salmonella spp., Clostridium spp., and L. monocytogenes) were analyzed. In the production stage of leafy vegetables, the sanitary indicator microorganisms was not detected regardless of cultivation method or it was detected to be less than $3.4\;Log\;CFU/100cm^2$. B. cereus and S. aureus were found to be 0.22~1.55 Log CFU/g in perilla leaf and lettuce produced by organic farms, and S. aureus was not detected and B. cereus was found to be 0.42~2.19 Log CFU/g in conventional farms. There were no significant differences between two cultivation methods. In the harvesting tools and soil mulching film, the contamination levels of sanitary indicator microorganisms and pathogenic microorganisms was low regardless of the cultivation method. However, there was a positive correlation ($R^2=0.4526$) in that the higher the microbial contamination level in the harvesting tool, the higher the microbial contamination on the surface of the plant. In addition, sanitary indicator microorganisms and pathogenic microorganisms were not detected or low in soil mulching during the production of organic leafy vegetables. As a result of this study, microbial hygiene control by soil mulching and harvesting tools was more important than difference of cultivation method in production of leafy vegetables.

Antibacterial effects of Chitosanon-ascorbate Treated Kwamaegi Prepared on Microorganism Contamination (Chitosan-ascorbate 처리 과메기에 있어서 오염미생물에 대한 저해효과)

  • Kim, Young-Sook;oh, Seung-Hee;Kim, Soon-Dong
    • KSBB Journal
    • /
    • v.24 no.2
    • /
    • pp.156-162
    • /
    • 2009
  • We examined saury, herring, gizzard shad kwamaegi to measure of microbic contamination rate of kwamegi that are sold in the market now. In the total bacteria, staphylococcus, peroxide value, and microorganisms is inhibited that from sample that we treated a substance with chitosan-ascorbate (CA) and other orders deep water (DW), ginseng steamed red and wine (GRW), NT (not treated). When we compared between SGRW and SNT, SCA show us more inhibition effect 0.22-0.49 log cycle in the total aerobacter. When we compared between HDW and HNT, HCA restraint 0.05-0.45log cycle, and when we compared between GDW and GNT, GCA inhibited 0.45 log cycle. In the coliform and E. coli, growths of microorganisms were inhibited followed order by treatment of CA, NT, and DW. GDW, HCA and HNT checked enough amount of water from the moisture measurement; but SGW, GCA, HEW and SCA showed 7-15% lack of moisture, and SNT and GNT have 10% more moisture. Peroxide value is changed to 41-51meq/kg when we did treat CA in there and a side that didn't add antimicrobial expressed the result numerically that 56-58meq/kg. In the sensory evaluation, customer gave preference to followed by Saury kwamaegi, herring, and gizzard shad kwamaegi. We have a point of view when kwamaeki manufactured if we add natural antibiotic and it uses to vacuum drying, we would inhibited of multiplication of microorganism, and of peroxides.

Recovery of Silicon Wafers from the Waste Solar Cells by H3PO4-NH4HF2-Chelating Agent Mixed Solution (인산-산성불화암모늄-킬레이트제 혼합용액에 의한 폐태양전지로부터 실리콘웨이퍼의 회수)

  • Koo, Su-Jin;Ju, Chang-Sik
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.666-670
    • /
    • 2013
  • Recovery method of silicon wafer from defective products generated from manufacturing process of silicon solar cells was studied. The removal effect of the N layer and antireflection coating (ARC) of the waste solar cell were investigated at room temperature ($25^{\circ}C$) by variation of concentration of $H_3PO_4$, $NH_4HF_2$, and concentration and types of chelating agent. Removal efficiency was the best in the conditions; 10 wt% $H_3PO_4$ 2.0 wt% $NH_4HF_2$, 1.5 wt% Hydantoin. Increasing the concentration of $H_3PO_4$, the surface contamination degree was increased and the thickness of the silicon wafe became thicker than the thickness before surface treatment because of re-adsorption on the silicon wafer surface by electrostatic attraction of the fine particles changed to (+). The etching method by mixed solution of $H_3PO_4$-$NH_4HF_2$-chelating agents was expected to be great as an alternative to conventional RCA cleaning methods and as the recycle method of waste solar cells, because all processes are performed at room temperature, the process is simple, and less wastewater, the removal efficiency of the surface of the solar cell was excellent.