• Title/Summary/Keyword: 폭발 해석

Search Result 431, Processing Time 0.025 seconds

The change of deflagration to detonation transition by wall cooling effect in ethylene-air mixture (에틸렌-공기 혼합물에서 벽면 온도 감소에 의한 연소폭발천이 현상 변화)

  • Gwak, Min-Cheol;Kim, ki-Hong;Yo, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.457-462
    • /
    • 2011
  • This paper presents a numerical investigation of deflagration to detonation transition (DDT) induced by shock wave and flame interaction in ethylene-air mixtures. Also shows the change of DDT triggering time by wall cooling effect. A model is consisted of the compressible reactive Navier-Stokes equations. And the effect of viscosity, thermal conduction, molecular diffusion, chemical reaction and wall effect are included. Using this model, the generation of hot spot by repeated shock and flame interaction, occurrence of detonation, and wall cooling effect of detonation confining boundaries are studied.

  • PDF

Sympathetic Detonation Modeling of PBXN-109 (PBXN-109가 장전된 155 mm 고폭탄의 순폭현상 해석)

  • Kim, Bohoon;Kim, Minsung;Yang, Seungho;Oh, Sean;Kim, Jinseok;Choi, Sangkyung;Yoh, Jai-Ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.1-11
    • /
    • 2014
  • Sympathetic detonation (SD) of high explosives occurs when a detonating donor initiates neighboring acceptors. The present study focuses on the hydrodynamic simulation of one-on-one sympathetic detonation of 155 mm charge filled with PBXN-109. Both unbuffered and buffered SD configurations are performed while changing the distance between each charge, in order to investigate the detonation sensitivity to a donor initiation. The cause of a SD is by a shock impact for the unbuffered case at a close range, while at a distant range, blast fragment penetration is the primary cause. The buffers can reduce the incident sensitivity to a SD by reducing the strengths of shock wave and impinging fragments.

A Basic Study on Effect Analysis of Adjacent Structures due to Explosion of Underground Hydrogen Infrastructure (지하 수소인프라 폭발에 따른 인접 구조물 영향 분석에 대한 기초 연구)

  • Choi, Hyun-Jun;Kim, Sewon;Kim, YoungSeok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.3
    • /
    • pp.21-27
    • /
    • 2022
  • For carbon neutrality, interest in R&D and infrastructure construction for hydrogen energy, an eco-friendly energy source, is growing worldwide. In particular, for hydrogen stations installed in downtown areas, underground hydrogen infrastructure are being considered to increase a safety distance from hydrogen tank explosions to adjacent structures. In order to design an appropriate location and depth of the underground hydrogen infrastructure, it is necessary to evaluate the impact of the explosion of the underground hydrogen infrastructure on adjacent structures. In this paper, a numerical model was developed to analyze the effect of the underground hydrogen infrastructure explosion on adjacent structures, and the over pressure of the hydrogen tank was evaluated using the equivalent TNT (Trinitrotoluene) model. In addition, parametric analysis was performed to estimate the stability of adjacent structures according to the construction conditions of the underground hydrogen infrastructure.

A Study of Establishment of the Infrastructure for Consequence Analysis of Metallic Dust Explosion (금속성 분진폭발의 영향 분석을 위한 기반구축에 관한 연구)

  • Jang, Chang Bong;Lee, Kyung Jin;Moon, Myong Hwan;Baek, Ju Hong;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.84-91
    • /
    • 2017
  • Recent years have witnessed the increased usage of flammable metals, such as aluminum or magnesium, in wide range of high-tech industries. These metals are indispensable for the improvement of physical properties of materials as well as the design capability of the final product. During the process, unwanted metal dusts could be released to the environment. This can lead to an occupational health and safety issues. Due to their flammable nature, more serious problem of an explosion can happen in extreme cases. The explosion is the combustion of tiny solid particles and vapor mixture, caused by pyrolysis. This complex composition makes engineering analysis more difficult, compared to simple gas explosions or vapor cloud combustions. The study was conducted to assess this light metal dust explosion in an effort to provide the bases for a risk assessment. Dust explosion characteristics of each material was carefully evaluated and an appropriate analysis tool was developed. A comprehensive database was also constructed and utilized for the calibration of the developed response model and the verification for its accuracy. Subsequently, guidelines were provided to prevent dust explosions that could occur in top-notch industrial processes.

Finite Element Analysis of Contact Pressure Behavior in Compression Ring-Oil Film (압축링-유막간의 접촉압력 거동에 관한 유한요소해석)

  • 김한구;김청균;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1995.06b
    • /
    • pp.48-53
    • /
    • 1995
  • 본 연구에서는 윤활유막의 접촉압력 거동문제를 다른 각도에서 유한요소기법으로 해석하고자 한다. 즉, 혼합기가 폭발하게 되면 피스톤과 실린더 사이의 윤활유막이 순간적으로 초고압을 받아서 윤활유막은 밀폐된 공간에서 마치 폴리머처럼 거동할 것이라고 가정할 수 있다. 이와 같은 현상은 극히 짧은 시간에 국부적으로 일어날 것으로 예상되며, 이러한 작동조건에서 피스톤 링의 접촉면 형상에 따른 피스톤 압축링-윤활유막 사이의 접촉압력 거동문제를 미시적일 측면에서 유한요소기법으로 피스톤의 동적문제를 해석하고자 한다.

  • PDF

Universal Distinct Element Code (개별요소 프로그램 UDEC의 소개)

  • 이선구;변광욱
    • Computational Structural Engineering
    • /
    • v.4 no.1
    • /
    • pp.42-43
    • /
    • 1991
  • 균열성암반의 모형화 기술은 계속적으로 보완발전되어 UDEC이 개발되었으며, 현재 UDEC의 최신판은 블록 내부를 다시 유한차분요소로 분할하여 블록의 소성거동(Mohr-Coulomb Model) 및 쪼개짐을 고려할 수 있고, 절리면에서의 유체흐름 및 유압의 발생, 그리고 열응력 해석 등 평면변형 문제의 정적해석과 지진 및 폭발하중을 고려한 동적해석이 가능하다. UDEC은 전처리 기능이 뛰어나 최소한의 입력데이타로써 전체 모형의 데이타를 자동생성시키며 절리면의 통계학적 자동생성 및 터널형상의 자동생성도 가능하다. UDEC은 실용적인 보강요소를 구비하여 Rock Bolt 뿐만 아니라 그라우트를 고려한 Cable Bolt를 모형화할 수 있으며 국부적인(Key Block)보강으로써 불연속체 전체의 안정을 검토할 수 있다.

  • PDF

Estimation of the Terminal Velocity of the Worst-Case Fragment in an Underwater Torpedo Explosion Using an MM-ALE Finite Element Simulation (MM-ALE 유한요소 시뮬레이션을 이용한 수중 어뢰폭발에서의 최악파편의 종단속도 추정)

  • Choi, Byung-Hee;Ryu, Chang-Ha
    • Explosives and Blasting
    • /
    • v.37 no.3
    • /
    • pp.13-24
    • /
    • 2019
  • This paper was prepared to investigate the behavior of fragments in underwater torpedo explosion beneath a frigate or surface ship by using an explicit finite element analysis. In this study, a fluid-structure interaction (FSI) methodology, called the multi-material arbitrary Lagrangian-Eulerian (MM-ALE) approach in LS-DYNA, was employed to obtain the responses of the torpedo fragments and frigate hull to the explosion. The Euler models for the analysis were comprised of air, water, and explosive, while the Lagrange models consisted of the fragment and the hull. The focus of this modeling was to examine whether a worst-case fragment could penetrate the frigate hull located close (4.5 m) to the exploding torpedo. The simulation was performed in two separate steps. At first, with the assumption that the expanding skin of the torpedo had been torn apart by consuming 30% of the explosive energy, the initial velocity of the worst-case fragment was sought based on a well-known experimental result concerning the fragment velocity in underwater bomb explosion. Then, the terminal velocity of the worst-case fragment that is expected to occur before the fragment hit the frigate hull was sought in the second step. Under the given conditions, the possible initial velocities of the worst-case fragment were found to be very fast (400 and 1000 m/s). But, the velocity difference between the fragment and the hull was merely 4 m/s at the instant of collision. This result was likely to be due to both the tremendous drag force exerted by the water and the non-failure condition given to the frigate hull. Anyway, at least under the given conditions, it is thought that the worst-case fragment seldom penetrate the frigate hull because there is no significant velocity difference between them.

A Review on Practical Use of Simple Analysis Method based on SDOF Model for the Stiffened Plate Structures subjected to Blast Loads (폭발하중을 받는 보강판 구조물의 간이 해석법에 대한 실용성 검토)

  • Kim, Ul-Nyeon;Ha, Simsik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • The offshore installation units may be subjected to various accidental loads such as collision from supply vessels, impact from dropped objects, blast load from gas explosion and thermal load from fire. This paper deals with the design and strength evaluation method of the stiffened plate structures in response to a blast load caused by a gas explosion accident. It is a comprehensive review of various items used in actual project such as the size and type of the explosive loads, general design procedure/concept and analysis method. The structural analyses using simple analysis methods based on SDOF model and nonlinear finite element analysis are applied to the particular FPSO project. Also validation studies on the design guidance given by simple analysis method based on SDOF model have also considered several items such as backpressure effects, material behavior and duration time of the overpressure. A good correlation between the prediction made by simple analysis method based on SDOF model and nonlinear finite element analysis can be generally obtained up to the elastic limit.

A Study of Interpretation of Separation Behavior in Gas Expansion Separation(GES) Bolt (가스팽창분리형 볼트 분리거동 해석 연구)

  • Lee Young Jo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.1
    • /
    • pp.27-34
    • /
    • 2005
  • The present work has been developed the study of interpretation of separation behavior in gas expansion separation(GES) bolt which has the separation characteristics without fragmentation and minimum pyre-shock during the operation of the explosive bolt. In order to obtain the performance of minimum pyre-shock, the present work used non-compressive material instead of separation explosives. The use of the interpretation processor could be extensively helped to design the shape and the amount of explosives in the explosive bolt having complex geometry, and to analyse the separation behavior during the operation. It is also proved that the GES bolt is the most suitable the separation system necessary to minimum pyre-shock and non fragmentation compare with others.

Damage Evaluation of Bi-directionally Prestressed Concrete Panels under Blast-fire Combined Loading (폭발 후 화재하중 시나리오에 따른 2방향 프리스트레스트 콘크리트 패널부재의 손상도 평가)

  • Choi, Ji-Hun;Choi, Seung-Jai;Kim, Tae-Kyun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.237-248
    • /
    • 2017
  • Frequent terror or military attack by explosion, impact, fire accidents have occurred recently. These attacks and incidents raised public concerns and anxiety of potential terrorist attacks on important infrastructures. However, structural behavioral researches on prestressed concrete (PSC) infrastructures such as Prestressed Concrete Containment Vessel (PCCV) and Liquefied Natural Gas (LNG) storage tanks under extreme loading are significantly lacking at this time. Also, researches on possible secondary fire scenarios after terror and bomb explosion has not been performed yet. Therefore, a study on PSC structural behavior from an blast-induced fire scenario was undertaken. To evaluate the blast-fire combined resistance capacity and its protective performance of bi-directional unbonded PSC member, blast-fire tests were carried out on $1,400mm{\times}1,000mm{\times}300mm$ PSC specimens. Blast loading tests were performed by the detonation of 25 kg ANFO explosive charge at 1.0 m standoff distance. Also, fire and blast-fire combined loading were tested using RABT fire loading curve. The test results are discussed in detail in the paper. The results can be used as basic research references for related research areas, which include protective design simulation under blast-fire combined loading.