• Title/Summary/Keyword: 포항 방사광 가속기

Search Result 38, Processing Time 0.022 seconds

Compressibility of $FeS_{2}$ ($FeS_{2}$의 압축성 연구)

  • Kim, Young-Ho;Hwang, Gil-Chan;Cho, Hyen-Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.3 s.49
    • /
    • pp.189-195
    • /
    • 2006
  • Compression work on a pyrite powder has been carried out using energy dispersive X-ray diffraction (EDXRD) with Mao-Bell type diamond anvil cell (DAC) and synchrotron radiation(SR) at room temperature. It has been reported the bulk moduli of pyrite show the large variations depending on the experimental conditions as well as the apparatus used. Thus, two kinds of sample in different pressure transmitting media of both NaCl and MgO powder emerged in alcoholic fluids were subjected to measure their compressibilities. Bulk moduli thus obtained are 138.9 GPa and 198.2 GPa, respectively, and this result contradicts to the anticipated values according to the hydrostaticity conditions of the sample chamber. This might be due to the alcoholic fluids phase transition mainly with the side effects from the difference of both solid state detector (SSD) used and E*d value applied. All experiments were performed at the Beam Line 1B2 of Pohang Light Source (PLS).

X-ray Radiography에 적합한 Double Multilayer Monochromaotr (DMM) 설계와 제작

  • Jeong, Sun-Yong;Yang, Seong-Seon;Im, Jae-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.118-118
    • /
    • 2013
  • DMM은 방사광가속기의 백색광으로부터 단색광을 추출하기 위해 두 개의 다층 박막 (multilayer) 거울을 사용하는데, 첫 번째 거울은 Bragg 반사를 통해 분광을 하여 단색광을 생산하는 용도이고, 두 번째 거울은 이 단색광을 반사시켜 지면과 평행하게 출사되게 하기 위함이다. 일반적으로 사용되는 DCM (Double Crystal Monochromator)과의 차이점은, Bragg 반사를 위해 DCM에서는 결정을 사용하는 반면 DMM은 밀도차이가 많이나는 두 종류의 물질을 교대로 쌓아 올린 다층 박막을 사용한다는 것이다. 다층 박막의 주기가 곧 Bragg 반사에서의 d-spacing이 되며, X-선 분광의 목적으로 사용되는 d-spacing은 10-50 $\AA$ 사이이다. DCM이 0.01% 대의 우수한 에너지 분해능을 보이는데 비해, DMM은 1% 정도이다. 이 때문에 출사광의 밝기가 DCM에 비해 100배 밝은 특징이 있어서 에너지 분해능보다 광량이 더 중요한 응용에서 DMM이 사용된다. X-선 영상이나 방사선치료가 바로 이러한 응용에 해당한다. DMM은 포항가속기연구소와 (주) 벡트론에서 공동 설계하였으며, (주)벡트론에서 제작하였다. 그림 1에 DMM의 외형과 내부 구조를 나타내었다. Bragg 각의 조절 범위는 0.24-0.9도 이다. 입사광과 출사광의 수직 방향 offset을 10 mm로 유지하기 위해 두 번째 다층 박막이 수평방향으로 1,000 mm 가량 이동할 수 있어야 한다. 이를 위해 두 대의 고니오미터 stage를 사용하여 각각 첫 번째 및 두 번째 다층 박막의 위치와 방향을 제어한다. 첫 번째 다층 박막을 제어하는 고니오미터 stage는 하부가 전체 프레임에 고정되어 있고, 이 고니오미터의 회전축에서 Bragg 각을 조절한다. 두 번째 다층 박막을 제어하는 고니오미터 stage는 높이방향과 수평방향으로 이동이 가능하다. 다층 박막의 pitch는 고니오미터의 회전축에서 조절한다. 그리고 tilt stage를 사용하여 다층 박막의 roll을 조절한다.

  • PDF

ADC In-vacuum Undulator Upgrade

  • Hong, Man-Su;Kim, Se-Hyeon;Gwon, Hyeok-Chae;Han, Hong-Sik;Ha, Tae-Gyun;Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.116.1-116.1
    • /
    • 2013
  • 포항가속기연구소 저장링에는 Dipole Magnet, Wiggler, Undulator 등 다양한 방사광발생장치를 설치하여 각종 실험에 사용하고 있다. 그중 ADC사에서 제작한 In- vacuum Undulator (이하, ADC-IVU)는 고휘도의 X-선 빔을 생성하여 생체고분자(단백질, DNA 등) 단결정의 X-선 회절 데이터를 획득하는 실험을 수행한다. 현재, ADC-IVU의 Rf finger 등 일부장치의 성능개선을 위한 장치 해체, 교체 작업과 재조립 및 정렬작업, 구동시험을 거치고 최종 초고진공 진공 달성을 위한 탈가스처리, NEG 활성화작업등을 마무리 하였다. 본 발표에서는 ADC-IVU의 성능개선 작업에 대한 전반적인 사항과 진공작업 및 그 결과를 내용으로 한다.

  • PDF

Thickness dependent dielectric properties of $BaTiO_3$/Sr$TiO_3$ Nano-structured artificial lattices (나노 구조로 된 $BaTiO_3$/Sr$TiO_3$ 산화물 인공격자의 두께 의존적인 유전특성)

  • 김주호;김이준;정동근;김인우;제정호;이재찬
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.56-56
    • /
    • 2003
  • BaTiO$_3$, SrTiO$_3$단일막과 BaTiO$_3$ (BTO)/SrTiO$_3$ (STO) 산화물 인공격자를 pulsed laser deposition (PLD) 법에 의해서 100 nm 두께의 (La,Sr)CoO3 (LSCO) 산화물 전극이 코핑된 MgO 단결정 기판 위에 증착시켰다. 이러한 기판위에서 2 unit cell의 적층 두께를 갖는 BTO/STO 초격자 (=BTO2/STO2)를 100~5 nm까지 변화시켰다. 또한 BTO와 STO 단일막도 같은 두께로 변화시켰다. 이러한 두께 범위에서 BTO, STO 단일막과 초격자의 격자변형에 따른 유전특성을 살펴 보았다. 두께 변화에 따른 단일막과 초격자의 구조 분석은 포항 방사광 가속기의 x-ray 회절에 의해서 이루어졌다. 다양한 두께를 갖는 BTO2/STO2 초격자에서 BTO와 STO 충은 in-plane 방향으로 격자정합을 유지하면서 변형되었다. 두께가 얇아지면서 하부 LSCO영향으로 BTO, STO의 n-plane 격자상수는 LSCO 격자상수 쪽으로 접근하였다. Out-of-plane 방향의 BTO 격자상수는 두께가 얇아지면서 증가하였고 반면에 STO 격자상수는 감소하였다. STO와 BTO 단일막의 격자변형은 두께가 얇아지면서 in-plane 방향으로 압축응력으로 인해 증가하였다. 그러나, 격자부정합도가 큰 BTO격자에서 더 많이 변형되었다. 또한 초격자에서 BTO격자가 BTO 단일막보다 더 많이 변형되었는데 초격자에서는 BTO, STO 두 층의 발달된 변형뿐만 아니라 하부 LSCO/MgO 기판의 영향을 함께 받고 있기 때문이다. 초격자와 단일막의 유전상수를 살펴보면은 두께가 감소하면서 유전상수가 감소하는 size effect을 보이고 있다. 하지만 초격자에서의 유전상수가 단일막보다 우수한 유전특성을 보이고 있다. 이러한 결과로 볼 때 격자변형이 size effect 영향을 끼치는 중요한 요소임을 확인하였다.

  • PDF

Experimental Study of Freeze and Thaw Effect on Gas Diffusion Layer Using XRay Tomography (X-선 단층 촬영을 이용한 동결과 융해가 기체확산층에 미치는 영향에 대한 실험적 연구)

  • Je, Jun-Ho;Kim, Jong-Rok;Doh, Sung-Woo;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.487-490
    • /
    • 2011
  • We used X-ray tomography to carry out an experimental study to visualize the effect of freeze and thaw cycles on the gas diffusion layer (GDL) in a polymer electrolyte membrane fuel cell (PEMFC). A PEMFC has freeze and thaw cycles if the fuel cell is operating at a below-freezing ambient temperature. The cycle permanently deforms the fuel-cell capillary structures and reduces the ability of the cell to generate electric power and also reduces its service life. The GDL is the thickest capillary layer in the fuel cell, so it experiences the most deformation. The X-ray tomography facility at the Pohang Accelerator Laboratory was used to observe the structural changes in GDLs induced by a freeze and thaw cycle. We discuss the effects of these structural changes on the power production and service life of PEMFCs.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

A Compression Study on a Synthetic Talc (합성 활석에 대한 압축 연구)

  • Kim, Young-Ho;Kim, Soon-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.283-291
    • /
    • 2014
  • Talc ($Mg_3Si_4O_{10}(OH)_2$), one of sheet silicates, is soft and has been widely used in industry. Powdered talc specimen was synthesized at the pressure of 200 MPa and temperature of $600^{\circ}C$ using external heated hydrothermal high pressure apparatus. High pressure angular dispersive X-ray diffraction (ADXRD) mode experiments were performed at the Pohang Light Source (PLS) using the symmetrical diamond anvil cell (SDAC). Compression pressure was loaded up to 11.06 GPa at room temperature. This synthetic talc shows no phase transition(s) within the present pressure limit. Based on ADXRD data, bulk modulus of talc was calculated to be 72.4 GPa using Birch-Muranghan equation of state (EOS). This value is lower than that of natural talc determined previously.

High Heat-load Slits for the PLS Multi-pole Wiggler (포항방사광가속기의 다극 위글러용 고 열량부하 슬릿)

  • Gil, K.H.;Kim, C.K.;Chung, C.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.1
    • /
    • pp.46-51
    • /
    • 2007
  • The HFMX((High Flux Macromolecular X-ray crystallography) beamline at Pohang Accelerator Laboratory uses beams from a multi-pole wiggler. Two horizontal and vertical slits relevant to high heat-load are installed at its front-end. In order to treat high heat-load with reducing beam scattering, the horizontal slit has two Glidcop blocks with a grazing incidence angle of $10^{\circ}$ of a grazing-incidence knife-edge configuration. The blocks adjust the slit gap by being translated along guides by two actuating bars, respectively. Water flowing through holes, drilled along the actuating bars, cools the heat-load of both blocks. The vortical slit has the same structure as the horizontal slit except its installation direction with respect to the vacuum chamber and its grazing incidence angle. By virtue of a pair of blocks translating on guides, no alignment between both blocks is required and the installed slits show stable operating performance. The cooling performance of the two slits has been also shown to be acceptable. In this paper, the detailed explanation for the design of the two slits is presented and their operating performance is discussed.